A clinically applicable deep-learning model for detecting intracranial aneurysm in computed tomography angiography images
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Intracranial aneurysm is a common life-threatening disease. Computed tomography angiography is recommended as the standard diagnosis tool; yet, interpretation can be time-consuming and challenging. We present a specific deep-learning-based model trained on 1,177 digital subtraction angiography verified bone-removal computed tomography angiography cases. The model has good tolerance to image quality and is tested with different manufacturers. Simulated real-world studies are conducted in consecutive internal and external cohorts, in which it achieves an improved patient-level sensitivity and lesion-level sensitivity compared to that of radiologists and expert neurosurgeons. A specific cohort of suspected acute ischemic stroke is employed and it is found that 99.0% predicted-negative cases can be trusted with high confidence, leading to a potential reduction in human workload. A prospective study is warranted to determine whether the algorithm could improve patients’ care in comparison to clinicians’ assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 3×
“Second, we used the Basic Block instead of the stacked convolution layer, thus the performance of the deep conventional network was boosted by the residual connection 28 .”
BackgroundMethodInfluentialSelf-citationLeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
Çiçek, Ö., Abdulkadir, A., Lienkamp, S. S., Brox, T., & Ronneberger, O. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_49 · Cited by 7,945
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2019) · Stroke · doi:10.1161/str.0000000000000211 · Cited by 7,468
Dual Attention Network for Scene Segmentation
Fu, J., Liu, J., Tian, H., Li, Y., Bao, Y., Fang, Z., & Lu, H. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00326 · Cited by 7,351 · cited 1×
“Last, the dual attention block 29 was employed to enforce the network to focus on the informative region and features.”
MethodThrombectomy 6 to 24 Hours after Stroke with a Mismatch between Deficit and Infarct
Nogueira, R. G., Jadhav, A. P., Haussen, D. C., Bonafe, A., Budzik, R. F., Bhuva, P., Yavagal, D. R., Ribo, M., Cognard, C., Hanel, R. A., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1706442 · Cited by 5,629
Thrombectomy for Stroke at 6 to 16 Hours with Selection by Perfusion Imaging
Albers, G. W., Marks, M. P., Kemp, S., Christensen, S., Tsai, J. P., Ortega-Gutierrez, S., McTaggart, R. A., Torbey, M. T., Kim-Tenser, M., Leslie-Mazwi, T., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1713973 · Cited by 4,930
Hemphill, J. C., Greenberg, S. M., Anderson, C. S., Becker, K., Bendok, B. R., Cushman, M., Fung, G. L., Goldstein, J. N., Macdonald, R. L., Mitchell, P. H., et al. (2015) · Stroke · doi:10.1161/str.0000000000000069 · Cited by 3,994
Connolly, E. S., Rabinstein, A. A., Carhuapoma, J. R., Derdeyn, C. P., Dion, J., Higashida, R. T., Hoh, B. L., Kirkness, C. J., Naidech, A. M., Ogilvy, C. S., et al. (2012) · Stroke · doi:10.1161/str.0b013e3182587839 · Cited by 3,512
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Ardila, D., Kiraly, A. P., Bharadwaj, S., Choi, B., Reicher, J. J., Peng, L., Tse, D., Etemadi, M., Ye, W., Corrado, G., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0447-x · Cited by 2,167
Vlak, M. H., Algra, A., Brandenburg, R., & Rinkel, G. J. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70109-0 · Cited by 2,075
Eliminating Waste in US Health Care
Hackbarth, A. D. (2012) · JAMA · doi:10.1001/jama.2012.362 · Cited by 1,746
van Gijn, J., Kerr, R. S., & Rinkel, G. J. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60153-6 · Cited by 1,677
Morgenstern, L. B., Hemphill, J. C., Anderson, C., Becker, K., Broderick, J. P., Connolly, E. S., Greenberg, S. M., Huang, J. N., Macdonald, R. L., Messé, S. R., et al. (2010) · Stroke · doi:10.1161/str.0b013e3181ec611b · Cited by 1,496 · cited 1×
“Early diagnosis of underlying IAs can both in fl uence clinical management and guide prognosis in intracerebral hemorrhage patients 6,7 .”
BackgroundGreving, J. P., Wermer, M. J. H., Brown, R. D., Morita, A., Juvela, S., Yonekura, M., Ishibashi, T., Torner, J. C., Nakayama, T., Rinkel, G. J. E., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70263-1 · Cited by 1,454
Bederson, J. B., Connolly, E. S., Batjer, H. H., Dacey, R. G., Dion, J. E., Diringer, M. N., Duldner, J. E., Harbaugh, R. E., Patel, A. B., & Rosenwasser, R. H. (2009) · Stroke · doi:10.1161/strokeaha.108.191395 · Cited by 1,189
Do Clinicians Overestimate the Severity of Intracerebral Hemorrhage?
Tilling, E. J., El Tawil, S., & Muir, K. W. (2019) · Stroke · doi:10.1161/strokeaha.118.022606 · Cited by 1,120
Thompson, B. G., Brown, R. D., Amin-Hanjani, S., Broderick, J. P., Cockroft, K. M., Connolly, E. S., Duckwiler, G. R., Harris, C. C., Howard, V. J., Johnston, S. C. (., et al. (2015) · Stroke · doi:10.1161/str.0000000000000070 · Cited by 1,046
Learning from massive noisy labeled data for image classification
Xiao, T., Xia, T., Yang, Y., Huang, C., & Wang, X. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298885 · Cited by 907 · cited 1×
“Unambiguous interpretations, which are called noisy labels can lead to an obviously biased performance of the model 39,40 .”
BackgroundDiagnostic Concordance Among Pathologists Interpreting Breast Biopsy Specimens
Elmore, J. G., Longton, G. M., Carney, P. A., Geller, B. M., Onega, T., Tosteson, A. N. A., Nelson, H. D., Pepe, M. S., Allison, K. H., Schnitt, S. J., et al. (2015) · JAMA · doi:10.1001/jama.2015.1405 · Cited by 751
Brown, R. D., & Broderick, J. P. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70015-8 · Cited by 708
Singh, H., Meyer, A. N. D., & Thomas, E. J. (2014) · BMJ Quality & Safety · doi:10.1136/bmjqs-2013-002627 · Cited by 677
Variability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Salman, R. A., M, W. P. A. N. E. T. H. H. H. A., Davenport, R. J., Lindsay Kenneth, W., & 周立新 (2007) · doi:10.3760/cma.j.issn.1007-9742.2007.02.122 · Cited by 475
McDonald, R. J., Schwartz, K. M., Eckel, L. J., Diehn, F. E., Hunt, C. H., Bartholmai, B. J., Erickson, B. J., & Kallmes, D. F. (2015) · Academic Radiology · doi:10.1016/j.acra.2015.05.007 · Cited by 460
Li, X., Zhang, S., Zhang, Q., Wei, X., Pan, Y., Zhao, J., Xin, X., Qin, C., Wang, X., Li, J., et al. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(18)30762-9 · Cited by 433
Self-citationDeep Self-Learning From Noisy Labels
Han, J., Luo, P., & Wang, X. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00524 · Cited by 313 · cited 1×
“Unambiguous interpretations, which are called noisy labels can lead to an obviously biased performance of the model 39,40 .”
BackgroundWith an eye to AI and autonomous diagnosis
Keane, P. A., & Topol, E. J. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0048-y · Cited by 304
Deep Learning–Assisted Diagnosis of Cerebral Aneurysms Using the HeadXNet Model
Park, A., Chute, C., Rajpurkar, P., Lou, J., Ball, R. L., Shpanskaya, K., Jabarkheel, R., Kim, L. H., McKenna, E., Tseng, J., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.5600 · Cited by 258
Deep Learning for MR Angiography: Automated Detection of Cerebral Aneurysms
Ueda, D., Yamamoto, A., Nishimori, M., Shimono, T., Doishita, S., Shimazaki, A., Katayama, Y., Fukumoto, S., Choppin, A., Shimahara, Y., et al. (2019) · Radiology · doi:10.1148/radiol.2018180901 · Cited by 233
The Epidemiology of Admissions of Nontraumatic Subarachnoid Hemorrhage in the United States
Rincon, F., Rossenwasser, R. H., & Dumont, A. (2013) · Neurosurgery · doi:10.1227/01.neu.0000430290.93304.33 · Cited by 213
Deep neural network‐based computer‐assisted detection of cerebral aneurysms in MR angiography
Nakao, T., Hanaoka, S., Nomura, Y., Sato, I., Nemoto, M., Miki, S., Maeda, E., Yoshikawa, T., Hayashi, N., & Abe, O. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25842 · Cited by 188
Y-Net: Joint Segmentation and Classification for Diagnosis of Breast Biopsy Images
Mehta, S., Mercan, E., Bartlett, J., Weaver, D., Elmore, J. G., & Shapiro, L. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00934-2_99 · Cited by 182
Predictors of Poor Quality of Life 1 Year After Subarachnoid Hemorrhage
Taufique, Z., May, T., Meyers, E., Falo, C., Mayer, S. A., Agarwal, S., Park, S., Connolly, E. S., Claassen, J., & Schmidt, J. M. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001042 · Cited by 171
Lubicz, B., Levivier, M., Francois, O., Thoma, P., Sadeghi, N., Collignon, L., & Balériaux, D. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0699 · Cited by 139
Shi, Z., Hu, B., Schoepf, U. J., Savage, R. H., Dargis, D. M., Pan, C., Li, X., Ni, Q. Q., Lu, G., & Zhang, L. J. (2020) · American Journal of Neuroradiology · doi:10.3174/ajnr.a6468 · Cited by 117
Self-citationBone-subtraction CT angiography for the evaluation of intracranial aneurysms.
Tomandl, B. F., Hammen, T., Klotz, E., Ditt, H., Stemper, B., & Lell, M. (2006) · PubMed · Cited by 105
Deep learning for automated cerebral aneurysm detection on computed tomography images
Dai, X., Huang, L., Qian, Y., Xia, S., Chong, W., Liu, J., Ieva, A. D., Hou, X., & Ou, C. (2020) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-020-02121-2 · Cited by 92
Self-citationComputer-Aided Detection of Intracranial Aneurysms in MR Angiography
Yang, X., Blezek, D. J., Cheng, L. T., Ryan, W. J., Kallmes, D. F., & Erickson, B. J. (2009) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-009-9254-0 · Cited by 86
Chen, G. Z., Zhang, L. J., Schoepf, U. J., Wichmann, J. L., Milliken, C. M., Zhou, C. S., Li, Q., Luo, S., & Lu, G. (2015) · European Radiology · doi:10.1007/s00330-014-3533-y · Cited by 39
Self-citationMaldaner, N., Stienen, M. N., Bijlenga, P., Croci, D. M., Zumofen, D., D’Alonzo, D., Marbacher, S., Maduri, R., Daniel, R. T., Serra, C., et al. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.04.131 · Cited by 25
Cited by
External Validation of Deep Learning Algorithms for Radiologic Diagnosis: A Systematic Review
Yu, A. C., Mohajer, B., & Eng, J. (2022) · Radiology: Artificial Intelligence · doi:10.1148/ryai.210064 · Cited by 408
Sun, G., Pan, Y., Kong, W., Xu, Z., Ma, J., Racharak, T., Nguyen, L.-M., & Xin, J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1398237 · Cited by 339
Advances in Deep Learning-Based Medical Image Analysis
Liu, X., Gao, K., Liu, B., Pan, C., Liang, K., Yan, L., Ma, J., He, F., Zhang, S., Pan, S., et al. (2021) · Health Data Science · doi:10.34133/2021/8786793 · Cited by 165
Self-citationA systematic collection of medical image datasets for deep learning
Li, J., Zhu, G., Hua, C., Feng, M., BasheerBennamoun, Li, P., Lu, X., Song, J., Shen, P., Xu, X., et al. (2021) · arXiv · doi:10.48550/arxiv.2106.12864 · Cited by 61
Self-citationDing, J., Luo, Y., Shi, H., Chen, R., Luo, S., Yang, X., Xiao, Z., Liang, B., Yan, Q., Xu, J., et al. (2023) · Journal of Diabetes Investigation · doi:10.1111/jdi.14069 · Cited by 9
Self-citation
Metadata
- Authors
- Shi, Z., Miao, C., Schoepf, U. J., Savage, R. H., Dargis, D. M., Pan, C., Chai, X., Li, X. L., Xia, S., Zhang, X., Gu, Y., Zhang, Y., Hu, B., Xu, W., Zhou, C., Luo, S., Wang, H., Mao, L., Liang, K., Wen, L., Zhou, L., Yu, Y., Lu, G. M., & Zhang, L. J.
- Venue
- Nature Communications
- Published
- 2020-11-30
- Volume
- 11
- Issue
- 1
- Pages
- 6090-6090
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3108194527
- Cited by
- 207
- References
- 43
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.