Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.

Self-assembly of tessellated tissue sheets by expansion and collision

Open access

Published version of a preprint

Abstract

Tissues do not exist in isolation—they interact with other tissues within and across organs. While cell-cell interactions have been intensely investigated, less is known about tissue-tissue interactions. Here, we studied collisions between monolayer tissues with different geometries, cell densities, and cell types. First, we determine rules for tissue shape changes during binary collisions and describe complex cell migration at tri-tissue boundaries. Next, we propose that genetically identical tissues displace each other based on pressure gradients, which are directly linked to gradients in cell density. We present a physical model of tissue interactions that allows us to estimate the bulk modulus of the tissues from collision dynamics. Finally, we introduce TissEllate, a design tool for self-assembling complex tessellations from arrays of many tissues, and we use cell sheet engineering techniques to transfer these composite tissues like cellular films. Overall, our work provides insight into the mechanics of tissue collisions, harnessing them to engineer tissue composites as designable living materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-022-31459-1

Cites

77 of 77 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 The shapes of colliding tissues are stereotyped and predictable. a–d Archetypal collision experiments (solid) and simulations (outline) for equally sized rectangles (a), equally sized circles (b), size-mismatched circles (c), and circle-rectangle pairs (d). Averages over several tissues at 60 h are shown in the rightmost panels (n = 4–7). See Supplementary Videos 1 and 4.
Fig. 1 The shapes of colliding tissues are stereotyped and predictable. a–d Archetypal collision experiments (solid) and simulations (outline) for equally sized rectangles (a), equally sized circles (b), size-mismatched circles (c), and circle-rectangle pairs (d). Averages over several tissues at 60 h are shown in the rightmost panels (n = 4–7). See Supplementary Videos 1 and 4.CC BY · PubMed Central
Fig. 2 Asymmetric tissue collisions produce boundary motion. a–c Initial condition of collisions between control (a), size mismatch (b), and density mismatch (c) rectangle tissue pairs. Micrographs are representative of n = 5 (control), n = 5 (size mismatch), and n = 4 (density mismatch) independent experiments with similar results. d Tissue boundary displacement in both mismatch and control collisions. e, f Kymographs of tissue velocity vx (e) and cell density (f) along the collision direction for control (left, n = 5), size mismatch (center, n = 5), and density mismatch (right, n = 4) collisions. The superimposed curves indicate initial midline location x0 (thin black dashed line), the geometric tissue centroid (thick black dashed line), the tissue boundary (cyan line), and the center of expansion (pink dash-dotted line), as defined in the text and Methods. The cyan star marks the average tissue fusion location, which occurs at the initial point of the tissue boundary line. Panels d–f are from the same data set. g Our model proposes that the tissue boundary moves driven by pressure gradients between tissues of different cell densities. h Consistent with our model, the velocity and the cell density gradient at the tissue boundary are negatively correlated (correlation coefficient r = −0.47). Small points represent individual data, big points correspond to the averages for each of our three assays, and the black line is a linear fit through the averages. This plot includes data from experiments with initial density mismatches higher than in panels d–f. The range of applicability of our model extends to all of these density mismatches (additional n = 16, Supplementary Figs. 4 and 5). Error bars are standard deviation. See Supplementary Videos 5 and 6.
Fig. 2 Asymmetric tissue collisions produce boundary motion. a–c Initial condition of collisions between control (a), size mismatch (b), and density mismatch (c) rectangle tissue pairs. Micrographs are representative of n = 5 (control), n = 5 (size mismatch), and n = 4 (density mismatch) independent experiments with similar results. d Tissue boundary displacement in both mismatch and control collisions. e, f Kymographs of tissue velocity vx (e) and cell density (f) along the collision direction for control (left, n = 5), size mismatch (center, n = 5), and density mismatch (right, n = 4) collisions. The superimposed curves indicate initial midline location x0 (thin black dashed line), the geometric tissue centroid (thick black dashed line), the tissue boundary (cyan line), and the center of expansion (pink dash-dotted line), as defined in the text and Methods. The cyan star marks the average tissue fusion location, which occurs at the initial point of the tissue boundary line. Panels d–f are from the same data set. g Our model proposes that the tissue boundary moves driven by pressure gradients between tissues of different cell densities. h Consistent with our model, the velocity and the cell density gradient at the tissue boundary are negatively correlated (correlation coefficient r = −0.47). Small points represent individual data, big points correspond to the averages for each of our three assays, and the black line is a linear fit through the averages. This plot includes data from experiments with initial density mismatches higher than in panels d–f. The range of applicability of our model extends to all of these density mismatches (additional n = 16, Supplementary Figs. 4 and 5). Error bars are standard deviation. See Supplementary Videos 5 and 6.CC BY · PubMed Central
Fig. 3 TissEllate approach to design complex tissue composites. a, b Target tricolor tessellation (a) and chosen initial condition (solid black lines) with accompanying final pattern simulated using TissEllate (b). c, d In vitro realization of the tissue composite, which self-assembles from the initial pattern (c) to the final tessellation by collision (d), representative of three independent experiments with similar results. e, f Initial pattern and final tessellation for a two-dimensional hexagonal lattice (e, one experiment) and another complex pattern (f, representative of six independent experiments with similar results). The white outlines indicate the simulated tissue shapes. See Supplementary Videos 8–10.
Fig. 3 TissEllate approach to design complex tissue composites. a, b Target tricolor tessellation (a) and chosen initial condition (solid black lines) with accompanying final pattern simulated using TissEllate (b). c, d In vitro realization of the tissue composite, which self-assembles from the initial pattern (c) to the final tessellation by collision (d), representative of three independent experiments with similar results. e, f Initial pattern and final tessellation for a two-dimensional hexagonal lattice (e, one experiment) and another complex pattern (f, representative of six independent experiments with similar results). The white outlines indicate the simulated tissue shapes. See Supplementary Videos 8–10.CC BY · PubMed Central
Fig. 4 Transfer of intact tissue tessellations. a Schematic of the tissue tessellation transfer process. A support membrane (white) facilitates cell sheet removal and transfer at room temperature from cell culture-ware with temperature-switchable cell adhesion (UpCell). Created with Biorender.com. b, c Tessellation on UpCell dish (b) is transferred to standard tissue-culture dish (c). Four independent tessellation transfers were performed with qualitatively similar results.
Fig. 4 Transfer of intact tissue tessellations. a Schematic of the tissue tessellation transfer process. A support membrane (white) facilitates cell sheet removal and transfer at room temperature from cell culture-ware with temperature-switchable cell adhesion (UpCell). Created with Biorender.com. b, c Tessellation on UpCell dish (b) is transferred to standard tissue-culture dish (c). Four independent tessellation transfers were performed with qualitatively similar results.CC BY · PubMed Central
Fig. 5 Tri-tissue collisions produce “escape” events. a, b Example configuration in which the magenta tissue nearly escapes in between the green tissues during expansion. Labels denote three tissues that participate in a tri-tissue collision leading to an escape event. The white line in b indicates the tissue boundary predicted by our simulation tool TissEllate based on binary collisions. Escapes occur in 50% of cases, n = 14 (Supplementary Fig. 7). c–e Close-up view of the escape process, from a different experiment with higher magnification. The same labeling scheme used as in panel a. Micrographs show one experiment, as representative example of the 7 of 14 independent experiments that resulted in escapes. f–h Tissue dynamics in a tri-tissue collision (f) feature a higher local cell speed in the escaping region than the converging region (g) with a p value of 0.006 using a two-sided Mann–Whitney U test (h). i, j A single tissue with a similar pre-escape geometry (i) does not have this speed increase in the escaping region (j). Plot shows mean with standard deviation across n = 7 (escape) and n = 8 (single tissue) independent collisions in a single experiment, of which associated micrographs are representative. Source data are provided as a Source Data file. See Supplementary Videos 11 and 12.
Fig. 5 Tri-tissue collisions produce “escape” events. a, b Example configuration in which the magenta tissue nearly escapes in between the green tissues during expansion. Labels denote three tissues that participate in a tri-tissue collision leading to an escape event. The white line in b indicates the tissue boundary predicted by our simulation tool TissEllate based on binary collisions. Escapes occur in 50% of cases, n = 14 (Supplementary Fig. 7). c–e Close-up view of the escape process, from a different experiment with higher magnification. The same labeling scheme used as in panel a. Micrographs show one experiment, as representative example of the 7 of 14 independent experiments that resulted in escapes. f–h Tissue dynamics in a tri-tissue collision (f) feature a higher local cell speed in the escaping region than the converging region (g) with a p value of 0.006 using a two-sided Mann–Whitney U test (h). i, j A single tissue with a similar pre-escape geometry (i) does not have this speed increase in the escaping region (j). Plot shows mean with standard deviation across n = 7 (escape) and n = 8 (single tissue) independent collisions in a single experiment, of which associated micrographs are representative. Source data are provided as a Source Data file. See Supplementary Videos 11 and 12.CC BY · PubMed Central
Fig. 6 Heterotypic tissue collisions. a Average kymograph of segmented fluorescence for collisions (n = 12) between rectangular MCF10A and MDA-MB-231 tissues of the same size and cell density. The MCF10A tissue displaces the MDA-MB-231 tissue. b–d Snapshots of the co-culture at the initial configuration (b), the collision time t = 12 h (c), and 24 h after collision, i.e., t = 36 h (d). The green line indicates the edge of MCF10A tissue. Micrographs are representative of 11 independent tissue collisions with similar results. e, f Average kymographs of segmented fluorescence (e) and velocity vx (f) for collisions (n = 11) between rectangular MCF10A and MCF7 monolayers of the same size and cell density. The cyan line indicates the tissue boundary. g–j Snapshots of the initial configuration (g), collision onset (h), partial engulfment (i), and full engulfment (j) of a circular MCF7 (magenta) tissue by a rectangular MCF10A (green) tissue. Simulations (yellow outlines) confirm that a difference in expansion speed is sufficient to predict the engulfment process. Engulfment repeated with similar results in two independent experiments. See Supplementary Videos 13–16.
Fig. 6 Heterotypic tissue collisions. a Average kymograph of segmented fluorescence for collisions (n = 12) between rectangular MCF10A and MDA-MB-231 tissues of the same size and cell density. The MCF10A tissue displaces the MDA-MB-231 tissue. b–d Snapshots of the co-culture at the initial configuration (b), the collision time t = 12 h (c), and 24 h after collision, i.e., t = 36 h (d). The green line indicates the edge of MCF10A tissue. Micrographs are representative of 11 independent tissue collisions with similar results. e, f Average kymographs of segmented fluorescence (e) and velocity vx (f) for collisions (n = 11) between rectangular MCF10A and MCF7 monolayers of the same size and cell density. The cyan line indicates the tissue boundary. g–j Snapshots of the initial configuration (g), collision onset (h), partial engulfment (i), and full engulfment (j) of a circular MCF7 (magenta) tissue by a rectangular MCF10A (green) tissue. Simulations (yellow outlines) confirm that a difference in expansion speed is sufficient to predict the engulfment process. Engulfment repeated with similar results in two independent experiments. See Supplementary Videos 13–16.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 77 references

Cited by

See all 34

Metadata

Authors
Heinrich, M. A., Alert, R., Wolf, A. E., Košmrlj, A., & Cohen, D. J.
Affiliations
Princeton University (US)
Corresponding author
  • Košmrlj, Andrej
  • Cohen, Daniel J.
Venue
Nature Communications
Published
2022-07-12
Volume
13
Issue
1
Pages
4026-4026
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4285040975
Cited by
34
References
77
Citations by year
2026: 3 · 2025: 6 · 2024: 13 · 2023: 8 · 2022: 3
FWCI
4.01
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
U.S. Department of Health & Human Services | National Institutes of Health (1R35 GM133574-01)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
tissue-tissue interactions, cell sheet engineering, cell migration, pressure gradient, cell density, collision dynamics, living materials, tissue mechanics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-assembly of tessellated tissue sheets by expansion and collision. https://app.cochat.ai/papers/10.1038/s41467-022-31459-1
The paper
Heinrich, M. A., Alert, R., Wolf, A. E., Košmrlj, A., & Cohen, D. J. (2022). Self-assembly of tessellated tissue sheets by expansion and collision. Nature Communications. https://doi.org/10.1038/s41467-022-31459-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.