Stretchable surface electromyography electrode array patch for tendon location and muscle injury prevention
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Surface electromyography (sEMG) can provide multiplexed information about muscle performance. If current sEMG electrodes are stretchable, arrayed, and able to be used multiple times, they would offer adequate high-quality data for continuous monitoring. The lack of these properties delays the widespread use of sEMG in clinics and in everyday life. Here, we address these constraints by design of an adhesive dry electrode using tannic acid, polyvinyl alcohol, and PEDOT:PSS (TPP). The TPP electrode offers superior stretchability (~200%) and adhesiveness (0.58 N/cm) compared to current electrodes, ensuring stable and long-term contact with the skin for recording (>20 dB; >5 days). In addition, we developed a metal-polymer electrode array patch (MEAP) comprising liquid metal (LM) circuits and TPP electrodes. The MEAP demonstrated better conformability than commercial arrays, resulting in higher signal-to-noise ratio and more stable recordings during muscle movements. Manufactured using scalable screen-printing, these MEAPs feature a completely stretchable material and array architecture, enabling real-time monitoring of muscle stress, fatigue, and tendon displacement. Their potential to reduce muscle and tendon injuries and enhance performance in daily exercise and professional sports holds great promise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurologic manifestations of hospitalized patients with coronavirus disease 2019 in Wuhan, China
Mao, L., Jin, H., Wang, M., Hu, Y., Chen, S., He, Q., Chang, J., Hong, C., Zhou, Y., Wang, D., et al. (2020) · JAMA Neurology · doi:10.1001/jamaneurol.2020.1127 · Cited by 7,166 · cited 2×
“Without appropriate supervision or guide, both amateur and professional athletes can have muscle strain or tendon tear in exercise or trainings 11,12 .”
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
A highly stretchable, transparent, and conductive polymer
Wang, Y., Zhu, C., Pfattner, R., Yan, H., Jin, L., Chen, S., Molina-Lopez, F., Lissel, F., Liu, J., Rabiah, N. I., et al. (2017) · Science Advances · doi:10.1126/sciadv.1602076 · Cited by 1,442 · cited 1×
“As a substitute material, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) is a more suitable conductive polymer due to its good biocompatibility, high conductivity, and high electrochemical stability 49 – 51 .”
Filtering the surface EMG signal: Movement artifact and baseline noise contamination
De Luca, C. J., Donald Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,277
Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
Kayser, L. V., & Lipomi, D. J. (2019) · Advanced Materials · doi:10.1002/adma.201806133 · Cited by 1,186
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005 · cited 1×
“It alsoreleases highlytoxic metalions intothe tissue and hasa risk of infection 26 .”
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894 · cited 2×
“We also noted that the RMS values recorded from channels 13, 17 and 21 which were close to muscle belly were higher than those recorded from 1, 5 and 9 on the distal tendon.”
Ribeiro, A. H., Ribeiro, M. H., Paixao, G. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · RePEc: Research Papers in Economics · doi:10.5281/zenodo.3625006 · Cited by 715
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655 · cited 1×
“While devices based on gold or platinum often have fl exibility or fatigue issues which restrict their working performances on soft skins 27 – 31 ; besides, lack of adhesiveness at electrode site would also cause motion artifacts in sEMG signals 32 .”
Cited by
Motion artefact management for soft bioelectronics
Yin, J., Wang, S., Tat, T., & Chen, J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00175-4 · Cited by 220
“Moreover, adhesive and conductive hydrogels may simultaneously act as conformable adhesive and biosignal recording electrodes 124,128 in soft bioelectronics.”
Liu, S., Li, W., Wang, X., Lu, L., Yao, Y., Lai, S., Xu, Y., Yang, J., Hu, Z., Gong, X., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c13458 · Cited by 64
Metadata
- Authors
- Yang, S., Cheng, J., Shang, J., Hang, C., Qi, J., Zhong, L., Rao, Q., He, L., Liu, C., Ding, L., Zhang, M., Chakrabarty, S., & Jiang, X.
- Venue
- Nature Communications
- Published
- 2023-10-14
- Volume
- 14
- Issue
- 1
- Pages
- 6494-6494
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4387639856
- Cited by
- 172
- References
- 74
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.