CoChat

Shape-changing electrode array for minimally invasive large-scale intracranial brain activity mapping

Open access
Wei, Shiyuan, Jiang, Anqi, Sun, Hongji, Zhu, Jingjun, Jia, Shengyi, Liu, Xiaojun, Xu, Zheng, Zhang, Jing, Shang, Yuanyuan, Fu, Xuefeng, Li, Gen, Wang, Puxin, Xia, Zhiyuan, Jiang, Tianzi, Cao, Anyuan, Duan, Xiaojie · 2024 · Nature Communications
Cited by 60

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Large-scale brain activity mapping is important for understanding the neural basis of behaviour. Electrocorticograms (ECoGs) have high spatiotemporal resolution, bandwidth, and signal quality. However, the invasiveness and surgical risks of electrode array implantation limit its application scope. We developed an ultrathin, flexible shape-changing electrode array (SCEA) for large-scale ECoG mapping with minimal invasiveness. SCEAs were inserted into cortical surfaces in compressed states through small openings in the skull or dura and fully expanded to cover large cortical areas. MRI and histological studies on rats proved the minimal invasiveness of the implantation process and the high chronic biocompatibility of the SCEAs. High-quality micro-ECoG activities mapped with SCEAs from male rodent brains during seizures and canine brains during the emergence period revealed the spatiotemporal organization of different brain states with resolution and bandwidth that cannot be achieved using existing noninvasive techniques. The biocompatibility and ability to map large-scale physiological and pathological cortical activities with high spatiotemporal resolution, bandwidth, and signal quality in a minimally invasive manner offer SCEAs as a superior tool for applications ranging from fundamental brain research to brain-machine interfaces.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-024-44805-2

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 60

Metadata

Authors
Wei, S., Jiang, A., Sun, H., Zhu, J., Jia, S., Liu, X., Xu, Z., Zhang, J., Shang, Y., Fu, X., Li, G., Wang, P., Xia, Z., Jiang, T., Cao, A., & Duan, X.
Venue
Nature Communications
Published
2024-01-24
Volume
15
Issue
1
Pages
715-715
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4391160617
Cited by
60
References
11
FWCI
9.46
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shape-changing electrode array for minimally invasive large-scale intracranial brain activity mapping. https://app.cochat.ai/papers/10.1038/s41467-024-44805-2
The paper
Wei, S., Jiang, A., Sun, H., Zhu, J., Jia, S., Liu, X., Xu, Z., Zhang, J., Shang, Y., Fu, X., Li, G., Wang, P., Xia, Z., Jiang, T., Cao, A., & Duan, X. (2024). Shape-changing electrode array for minimally invasive large-scale intracranial brain activity mapping. Nature Communications. https://doi.org/10.1038/s41467-024-44805-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.