Man/machine interface based on the discharge timings of spinal motor neurons after targeted muscle reinnervation
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Invasive recording techniques routinely use peripheral in vivo tissues with electroneurography (ENG)[277,278] and electromyography (EMG),[279,280] which can record peripheral nerve activity and muscle electrical signals respectively.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [279]
In the citing paper
“Farina et al tested the power of an offline man/machine interface that uses the discharge timings of spinal motor neurons to control upper-limb prostheses.22”
From Artificial intelligence in healthcare: past, present and future (2017) · cites this paper as [22]
Citations
Cites
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Self-citationOn the stability of inverse problems
Tikhonov, A. N. (1943) · Доклады Академии наук · Cited by 1,325
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Lu, T.-W., & O’Connor, J. J. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00158-4 · Cited by 924
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 4×
“The only exception is the signal-based mapping for simultaneous and proportional control of multiple degrees of freedom based on principal component analysis (PCA) (experiment 3), for which we used the full extended estimated sources (as in equation (3)) as input.”
MethodInfluential
Cited by
Items 201–300 of 359
Ensemble Learning Method for the Continuous Decoding of Hand Joint Angles
Wang, H., Tao, Q., & Zhang, X. (2024) · Sensors · doi:10.3390/s24020660 · Cited by 9
“Zhu et al. [10] and Dario’s teams [11] obtained reliable motor neuron action potential signals through the use of high-density sEMG signal acquisition equipment, providing a strong foundation for the advanced control of intelligent prosthetic limbs.”
BackgroundCaillet, A. H., Phillips, A., Modenese, L., & Farina, D. (2024) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2024.102873 · Cited by 14
Self-citationDesign Principles of a Light, Wearable Upper Limb Interface for Prosthetics and Teleoperation
Castellini, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00020-5 · Cited by 9
A VMD-Based Noise-Specific and Adaptive Removal Method for High-Density Surface EMG
Wang, W., Gu, Y., Zhang, Y., Bai, J., & Liu, T. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3469387 · Cited by 8
“by electrodes placed on the skin, and has been widely used in prosthetic control [1], human–robot interaction [2], and rehabilitation [3].”
Toward Hand Gesture Recognition Using a Channel-Wise Cumulative Spike Train Image-Driven Model
Yu, Y., Zhou, Z., Xu, Y., Chen, C., Guo, W., & Sheng, X. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0219 · Cited by 15
“However, the sEMG signals of these studies are merely rough and superficial counterparts of the underlying neural control signals and susceptible to the interference of noises [ 11 , 12 ].”
Adaptive Neural Decoder for Prosthetic Hand Control
Montgomery, A. E., Allen, J. M., & Elbasiouny, S. M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.590775 · Cited by 9
Khodadadi, V., Rahatabad, F. N., Sheikhani, A., & Dabanloo, N. J. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103852 · Cited by 9
Vujaklija, I., & Farina, D. (2022) · Springer eBooks · doi:10.1007/978-3-031-10355-1_41 · Cited by 8
Self-citationFylstra, B. L., Dai, C., Hu, X., & Huang, H. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513661 · Cited by 8
Ma, J., Wang, L., Wu, R., Zhang, N., Wei, J., Li, J., Li, Q., Tan, L., Li, G., Jiang, N., et al. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01639-3 · Cited by 12
“It offers superior performance over traditional EMG control systems, paving the way for more accurate and intuitive neural interfaces [9].”
Self-citationYeung, D., Negro, F., & Vujaklija, I. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3326065 · Cited by 8
“For instance, [18], [53], [54] utilized linear SVM while [16] used LDA, [21], [51] used LR and in [28], MLPs with two hidden layers were used.”
MethodSelf-citationZhao, H., Zhang, X., Chen, X. '., & Zhou, P. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108434 · Cited by 7
Evaluating Generalization Capability of Bio-inspired Models for a Myoelectric Control: A Pilot Study
Camardella, C., Barsotti, M., Murciego, L. P., Buongiorno, D., Bevilacqua, V., & Frisoli, A. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-26766-7_67 · Cited by 7
Chen, C., Yu, Y., Sheng, X., & Zhu, X. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176362 · Cited by 8
Montazerin, M., Rahimian, E., Naderkhani, F., Atashzar, S. F., Alinejad‐Rokny, H., & Mohammadi, A. (2023) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp49357.2023.10096192 · Cited by 7
“HD-sEMG signals are modelled as a spatio-temporal convolution of MUSTs, which provide an exact physiological description of how each hand movement is encoded at neurospinal level [22].”
MethodHighly accurate real-time decomposition of single channel intramuscular EMG
Yu, T., Akhmadeev, K., Carpentier, É. L., Aoustin, Y., & Farina, D. (2022) · HAL · doi:10.1109/tbme.2021.3104621 · Cited by 1
Self-citationForearm muscle activity estimation based on anatomical structure of muscles
Okajima, S., Costa‐García, Á., Ueda, S., Yang, N., & Shimoda, S. (2022) · The Anatomical Record · doi:10.1002/ar.24910 · Cited by 7
“Farina et al. (2017) proposed a method for estimating spinal motor neuron activity using high-density electromyography.”
MethodMishra, S., Abbas, M., Jindal, K., Narayan, J., & Dwivedy, S. K. (2022) · Design science and innovation · doi:10.1007/978-981-16-9455-4_11 · Cited by 9
Novel Control Strategies for Upper Limb Prosthetics
Vujaklija, I. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01845-0_34 · Cited by 7
Self-citationCui, Z., & Lin, C. (2024) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2024.102971 · Cited by 6
Long-Term Finger Force Predictions Using Motoneuron Discharge Activities
Ruan, Y., Meng, L., & Hu, X. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3540139 · Cited by 6
Sinha, A., Lee, J.-H., Kim, J., & So, H. (2024) · Materials Horizons · doi:10.1039/d4mh00522h · Cited by 6
Wang, W., He, L., Wang, J., Pan, M., Yi, J., Cheng, N., & Liu, T. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3480235 · Cited by 6
“We set data windows of 200 ms in 50-ms increments, which is considered appropriate to meet real-time requirements [4], [40].”
MethodUnsupervised Neural Decoding to Predict Dexterous Multi-Finger Flexion and Extension Forces
Meng, L., & Hu, X. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3510525 · Cited by 7
“As MUAPs originate from the activations of motor units (MUs), it is possible to extract the neural-drive information from the microscopic perspective (via motoneuron discharge events), with the advancement of flexible high-density sEMG (HD-sEMG) electrode array techniques [28].”
Taleshi, M., Bubeck, F., Brunner, P., Gizzi, L., & Vujaklija, I. (2025) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00603.2024 · Cited by 7
Self-citationDetecting single motor-unit activity in magnetomyography
Noury, N., Marquetand, J. C., Hartwig, S., Middelmann, T., Broser, P. J., & Siegel, M. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adeaeb · Cited by 10
“This approach has been useful not only for studying MUs, but also for human-machine interfaces [6, 18–21].”
Artificial intelligence in medical diagnosis
Sapra, R. L., Jaiswal, R., Jha, G. K., & Nundy, S. (2020) · Current Medicine Research and Practice · doi:10.4103/cmrp.cmrp_56_20 · Cited by 9
Peripheral Neuroergonomics – An Elegant Way to Improve Human-Robot Interaction?
Vecchio, A. D., Castellini, C., & Beckerle, P. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.691508 · Cited by 6
“…brain-machine interfaces using surface electroencephalography as well as electrocorticography with direct implants on the motor cortex and spinal implants (Micera et al., 2010), or by decoding spinal motoneurons from high-density EMG signals (Farina et al., 2017; Del Vecchio and Farina, 2019).”
MethodLubel, E., Rohlén, R., Sgambato, B. G., Barsakcioglu, D. Y., Ibáñez, J., Tang, M., & Farina, D. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3340019 · Cited by 6
“Recently, more accurate control has been achieved following developments enabling the extraction of MN discharge times from HDsEMG signals [47], [48], [49], [50], [51].”
Self-citationContinuous Estimation of Grasp Kinematics with Real-Time Surface EMG Decomposition
Chen, C., Ma, S., Sheng, X., & Zhu, X. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-27541-9_10 · Cited by 6
Cut wires: The Electrophysiology of Regenerated Tissue
Lowe, A. L., & Thakor, N. V. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00062-y · Cited by 6
In-silico development and assessment of a Kalman filter motor decoder for prosthetic hand control
Gamal, M., Mousa, M. H., Eldawlatly, S., & Elbasiouny, S. M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104353 · Cited by 6
Ferrante, L., Boesendorfer, A., Barsakcioglu, D. Y., Baumgartner, B., Al-Ajam, Y., Woollard, A., Kang, N., Aszmann, O. C., & Farina, D. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01537-y · Cited by 10
“40, the concept of human– machine interface based on decoding the neural activity of reinner-vated motor units was first introduced.”
Self-citationMuscle Synergy-driven Motor Unit Clustering for Human-Machine Interfacing
Taleshi, M., Yeung, D., Negro, F., & Vujaklija, I. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871356 · Cited by 5
“The identified MUST can then, theoretically, be used as a feature as a myocontrol signal [11].”
MethodSelf-citationEstimating muscle force based on a neuromuscular decoding approach adaptive to fatigue conditions
Liu, Y., Zhao, H., Yong, S., Zhang, L., Chen, X., & Zhang, X. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106769 · Cited by 6
Meng, L., & Hu, X. (2024) · IEEE Internet of Things Journal · doi:10.1109/jiot.2024.3520990 · Cited by 5
“In contrast, the advent of flexible high-density sEMG (HD-sEMG) electrodes facilitated the development of finger force prediction from a microscopic perspective at the MU level [28].”
Li, Y., Xu, G., Zhang, K., Wang, G., & Zheng, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3551898 · Cited by 10
“…mechanisms under physiological and pathological conditions [1], [2], [3], diagnosis of movement disorders [4], and human–machine interface (HMI) [5], [6], mainly because MU discharge activities reflect the neural drive input from the central nervous system and regulate muscle contraction state…”
Application of AI and ML Techniques for Revolutionized Health Care System
Kavitha, M., & Roobini, S. (2022) · International Conference on Artificial Intelligence and Smart Energy (ICAIS) · doi:10.1109/icais53314.2022.9742899 · Cited by 5
Low-Latency Gesture Recognition From Spatial Filtering of Single-Element Ultrasound Signals
He, J., He, H., Pradhan, A., & Jiang, N. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3271722 · Cited by 5
“as electrical [8], mechanical [9], optical [10], and ultrasound”
BackgroundSelf-citationAdaptive motor unit decomposition using a cross-validation-based update policy
Ma, T., & Hu, X. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110479 · Cited by 5
Estimation of Finger Joint Angle Based on Neural Drive Extracted from High-Density Electromyography
Dai, C., Cao, Y., & Hu, X. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513152 · Cited by 6
A Classification Model Based on an Adaptive Neuro-fuzzy Inference System for Disease Prediction
Mohanty, R., Solanki, S. S., Mallick, P. K., & Pani, S. K. (2020) · Studies in computational intelligence · doi:10.1007/978-981-15-5495-7_7 · Cited by 8
Generalized Finger Motion Classification Model Based on Motor Unit Voting
Liu, X., Zhou, M., Dai, C., Chen, W., & Ye, X. (2020) · Motor Control · doi:10.1123/mc.2020-0041 · Cited by 5
Zhu, S., Zhou, S., Chen, Z., Song, W., & Jin, L. (2021) · Transactions of the Institute of Measurement and Control · doi:10.1177/01423312211044031 · Cited by 6
“Farina et al. (2014) and Farina et al. (2017) decomposed the collected Surface Electromyography (sEMG) 1The Ocean College, Zhejiang University, China 2Hainan Institute of Zhejiang University, China 3Shanghai Shenqing Industry Co. Ltd., China Corresponding author: Zheng Chen, Hainan Institute of…”
BackgroundHuang, J., Wang, P., Wang, W., WEI, J., Yang, L., Liu, Z., & Li, G. (2024) · Bioengineering · doi:10.3390/bioengineering11090904 · Cited by 4
Zhao, H., Liu, Y., Li, X., Chen, X. '., & Zhang, X. (2024) · International Journal of Neural Systems · doi:10.1142/s0129065725500145 · Cited by 5
Cross-person decomposition of surface electromyogram for efficient motor unit activity predictions
Meng, L., & Hu, X. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adfc99 · Cited by 5
“In neurorehabilitation, patterns of MU firings can serve as neural-machine interface for interactions with assistive technologies [19, 20].”
InfluentialDecoding Spikes From Multiunit Data
Farina, D., & Yu, T. (2026) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2025.3647848 · Cited by 5
“Spike decoding accuracy and speed have improved substantially over the past decades, enabling applications in diagnosis [16], [17], [18], motor-control studies [14], [15], human– machine interfaces (HMI) [175], [176], [177] and brain– machine interfaces (BMI) [12], [13].”
Self-citationPotential Use of Artificial Intelligence in a Healthcare System
Agrawal, O. D., & Madhavi, J. S. (2022) · The Chinese Journal of Artificial Intelligence · doi:10.2174/2666782701666220805105655 · Cited by 5
Lowe, A. L., Rivera-Santana, M. V., Bopp, T. S., Quinn, K. N., Johnson, J., Ward, C. W., Chung, T., TUFFAHA, S. H., & Thakor, N. V. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1328520 · Cited by 6
Ying, Z., Zhang, X., Li, S., Nakashima, K., Shu, L., & Sugita, N. (2024) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra57147.2024.10611356 · Cited by 6
“Most of these studies have focused on isometric contraction experiments and offline evaluations [27, 30, 31].”
BackgroundWrist Torque Estimation by Combining Motor Unit Discharges With Musculoskeletal Model
Chen, C., Zhao, J., Yu, Y., Sheng, X., & Zhu, X. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3509859 · Cited by 4
Badr, S., Tahri, M., Maanan, M., Kašpar, J., & Yousfi, N. (2025) · Systems Biology in Reproductive Medicine · doi:10.1080/19396368.2024.2445831 · Cited by 6
“…and AI systems have already been adopted and employed in other medical fields (Vogiatzi et al. 2019), including neurology (Bouton et al. 2016; Farina et al. 2017), drug design (Jing et al. 2018), cancer research (Somashekhar et al. 2016; Esteva et al. 2017; Vulli et al. 2022), skin disease…”
Control Strategies for Functional Upper Limb Prostheses
Hahne, J. M., Prahm, C., Vujaklija, I., & Farina, D. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_13 · Cited by 6
Self-citationA Bipolar Myoelectric Sensor-Enabled Human-Machine Interface Based On Spinal Module Activations
Yi, C., Jiang, F., Lu, G., Yang, C., Ding, Z., Zhu, J., & Liu, J. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9561535 · Cited by 6
“reflecting cortical input with partial linearity [12].”
BackgroundAich, K., Kashyap, S., Tyagi, K., Verma, I., Chauhan, A., & Jain, C. K. (2023) · OBM Neurobiology · doi:10.21926/obm.neurobiol.2304198 · Cited by 5
A Genre of Cognitive Evolutions Through Artificial Superintelligence and Robotics Technology
Mostufa, S., & Chakrabarti, K. (2024) · Studies in Rhythm Engineering · doi:10.1007/978-981-97-0232-9_4 · Cited by 6
Monitoring at-home prosthesis control improvements through real-time data logging
Osborn, L. E., Moran, C. W., Dodd, L. D., Sutton, E. E., Acosta, N. N., Wormley, J. M., Pyles, C. O., Gordge, K. D., Nordstrom, M. J., Butkus, J., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7b · Cited by 4
“Advances in EMG decoding have enabled users to intuitively control their prosthesis using various signal processing techniques such as pattern recognition [12], deconvolution and musculoskeletal modelling [13], and sparsity-based adaptive classification [14].”
A dataset of a stimulated biceps muscle of electromyogram signal by using rossler chaotic equation
Khodadadi, V., Rahatabad, F. N., Sheikhani, A., & Dabanloo, N. J. (2023) · Data in Brief · doi:10.1016/j.dib.2023.109438 · Cited by 4
“In addition, by computing quantitative criteria from chaotic EMG signals and incorporating them into modeling and suitable prostheses, it becomes possible to mitigate motion deviations in prosthetic devices [10] .”
Multiscale Intermuscular Coupling Analysis via Complex Network-Based High-Order O-Information
Yu, C., She, Q., Houston, M. J., Tan, T., & Zhang, Y. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3525467 · Cited by 3
Flexible circuits for bionic limbs: a high impedance multiplexing front-end for myoelectric control
van Oosterhout, K., van Diemen, S., Timmermans, M., Fattori, M., Sartori, M., & Cantatore, E. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00492-7 · Cited by 6
“Thesesystemstypicallyincorporatecontrolmethods thatinterpretbioelectricalsignalsfromtheuser,enablingintuitivepros-theticmovement 2,3 .”
Self-citationCheng, L. P., Guo, A., Li, J., Lei, Q., Li, M., Guo, X., Chen, C., Zhu, X., & Zhang, J. (2025) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ae01fe · Cited by 9
Implantable Myoelectric Sensors for Prosthetic Control
Gstoettner, C., Salminger, S., Bergmeister, K. D., Willensdorfer, A., Aman, M., & Aszmann, O. C. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_14 · Cited by 4
Self-citationVaskov, A. K., & Chestek, C. A. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.04.003 · Cited by 3
“One of the main challenges of existing systems is the ability to extract specific motor commands from surface EMG, which represents a spatiotemporal summation of motor unit activity.(9) Classifiers, the algorithmic engine of pattern recognition systems, are adept at distinguishing movements from such summaries and can…”
BackgroundA neural-based approach to hand gesture recognition with HD-sEMG
Xie, Y., Wang, P., Chen, W., Wang, W., & Liu, L. (2022) · Chinese Control Conference (CCC) · doi:10.23919/ccc55666.2022.9902077 · Cited by 3
“3145 mands of an upper-limb prosthese [7] , demonstrating the superior performance of neural signals in hand gesture recognition relative to classical EMG features.”
BackgroundWang, S., Zhu, S., & Shang, Z. (2023) · Applied Sciences · doi:10.3390/app13020923 · Cited by 3
Deep Forest Model Combined with Neural Networks for Finger Joint Continuous Angle Decoding
Wang, H., & Tao, Q. (2023) · Lecture notes in computer science · doi:10.1007/978-981-99-6480-2_45 · Cited by 3
Guo, R., Chen, C., & Zhu, X. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3504577 · Cited by 3
Corticomuscular coherence existed at the single motor unit level
Zheng, Y., Zheng, B., Qiang, W., Peng, Y., Xu, G., Wang, G., Li, L., & Shin, H. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2024.120999 · Cited by 4
Impact of Noise on Deep Learning-Based Pseudo-Online Gesture Recognition with High-Density EMG
Taleshi, M., Yeung, D., Trong, M. D., Negro, F., Deny, S., & Vujaklija, I. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11254719 · Cited by 3
“Thanks to advances in machine learning methods and computational hardware, many sEMG-based HMIs now achieve high accuracies in controlled settings [4], [5].”
Self-citationSartori, M., & Farina, D. (2018) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2018.8487191 · Cited by 3
Self-citationŠavc, M., & Holobar, A. (2021) · IEEE Access · doi:10.1109/access.2021.3078644 · Cited by 5
“Among other things, it has been used to study muscle synergies [3]–[9], improve the rehabilitation procedures [10], [11], control bionic limbs [12], prosthetic and”
MethodA Neural-Driven Musculoskeletal Model for Continuous Estimation of Hand and Wrist Movements
Yue, S., Li, J., & Pan, L. (2022) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber55403.2022.9907258 · Cited by 3
“Recently, with the development of high-density EMG, the HMI based on the neural drive has drawn researchers’ attentions [19], [20].”
BackgroundArm movements effect on grasping force prediction using surface electromyography signals
Chen, C., Xie, T., Yao, L., Sheng, X., & Zhu, X. (2017) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2017.8324496 · Cited by 3
“MUAPts represent the direct neural drive into muscles so that it can be used to prediction force and motion patterns [22].”
Elucidating Sensorimotor Control Principles with Myoelectric Musculoskeletal Models
Goodman, S. E., & Hasson, C. J. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00531 · Cited by 4
“Knowing how the CNS controls its redundant musculature is of interest for rehabilitation, as a similar problem exists in the control of advanced prostheses and exoskeletons (Farina et al., 2014, 2017; Ison and Artemiadis, 2014).”
BackgroundOsborn, L. E., Moran, C. W., Sutton, E. E., Crego, A. C. G., Forsberg, J. A., Fifer, M. S., & Armiger, R. S. (2020) · UNB Conferences · doi:10.57922/mec.25 · Cited by 3
Vetschera, P., Koberstein‐Schwarz, B., Schmitt‐Manderbach, T., Dietrich, C., Hellmich, W., Chekkoury, A., Symvoulidis, P., Reber, J., Westmeyer, G. G., López‐Schier, H., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/586933 · Cited by 3
Andalib, A., Farina, D., Vujaklija, I., Negro, F., Aszmann, O. C., Bashirullah, R., & Príncipe, J. C. (2019) · arXiv (Cornell University) · doi:10.13140/rg.2.2.29259.95528/1 · Cited by 3
Self-citationPan, L., Yan, X., Yue, S., & Li, J. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-025-03321-1 · Cited by 2
“…and validated the possibility of using a blind source separation algorithm to convert EMG signals into motor unit (MU) discharges and estimate motor neuron discharge times at the population level, which can be mapped to control commands for continuous movements in multiple prosthetic DOFs [26].”
DWMS-HGR: 1D CNN for Hand Gesture Recognition on Normalized sEMG Signals with Sliding Window
Gehlot, N., & Kumar, R. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-96-1185-0_11 · Cited by 2
Yin, Z., Chen, C., Meng, J., & Zhu, X. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110325 · Cited by 2
Li, D., Chen, C., Zhu, K., Guo, R., & Shull, P. B. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3575252 · Cited by 5
Direct Learning of Neuronal Firing Representations for Long-Term Motor Intent Predictions
Meng, L., & Hu, X. (2025) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2025.3597271 · Cited by 2
“For example, motoneuron discharge trains are extracted from HD-sEMG signals via blind source separation (BSS) techniques for detailed and accurate analysis of neuromuscular activity [20], [21], [22].”
Dere, M. D., Ku, G., Jo, J.-H., Cheong, S., Ali, S., & Lee, B. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3622132 · Cited by 2
“EMG decomposition [13], [14], domain-specific model architecture designs [15], [16], [17], [18], [19], [20], data engineering [21], [22], [23], and on-device continual learning [24], [25], [26] have been proposed to mitigate model collapse due to EMG disturbances.”
Promises and performance in brain–machine interfaces: will AI be our saviour?
Saldanha, P., Vaupel, M., Dunn, B. A., & Whitlock, J. R. (2026) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-026-02169-2 · Cited by 2
“By strapping a lightweight band around the forearm, Meta contends that it can capture peripheral manifestations of neural intent—namely, the electrical signals propagating through the median and ulnar nerves as they activate the forearm muscles [12, 17].”
Spinal Interfacing via Muscle Recordings for Neuroprosthesis Control
Muceli, S., & Farina, D. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_29-1 · Cited by 2
Self-citationHigh-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 3
Self-citationMeng, L., & Hu, X. (2024) · IEEE International Conference on Human-Machine Systems (ICHMS) · doi:10.1109/ichms59971.2024.10555639 · Cited by 2
“…of wearable techniques, particularly in the context of flexible high-density surface electromyography (sEMG) electrode arrays, it is possible to conduct sEMG-related analysis at the microscopic level (via decomposed neuronal discharge events) [7], not just limited to using macroscopic features.”
BackgroundHuang, J., Li, X., Wei, J., Niu, C. M., & Li, G. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3558292 · Cited by 2
“However, for above-elbow and above-knee amputees, the deficiency of EMG signals from residual limbs makes myoelectric prostheses be difficult to achieve intuitive multifunctional prosthetic control, resulting in a high ratio of myoelectric prostheses abandonment [5], [6], [7].”
Designing Feedback Controllers for Human-Prosthetic Systems Using H∞ Model Matching
Costacurta, J. C., Osborn, L. E., Thakor, N. V., & Sarma, S. V. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512797 · Cited by 2
“Various control methods have already been implemented to translate EMG signals into relevant inputs to a prosthesis [2], [3].”
BackgroundMethodEstimating the single-DoF kinematics of wrist from motor unit behaviors
Chen, C., Yu, Y., Chai, G., Sheng, X., & Zhu, X. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716938 · Cited by 3
“Actually, the classification of MUSTs has been used for discrete motion recognition with low classification errors [15], [17].”
MethodA Motor Unit-specific Images Based Scheme for Continuous Estimation of Wrist Torques - A Pilot Study
Yu, Y., Chen, C., Sheng, X., & Zhu, X. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9283000 · Cited by 2
“Dario et al. constructed a neural interface for targeted muscle reinnervation (TMR) subjects using motor units (MUs) decomposed from HD-EMG, in which the extracted features from discharge timings of MUs were mapped into hand gestures or wrist kinematics [14].”
MethodOn Detecting the Invariant Neural Drive to Muscles during Repeated Hand Motions: A Preliminary Study
Xia, M., Chen, C., Sheng, X., & Zhu, X. (2021) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip49856.2021.9665089 · Cited by 2
“Motor unit firing timings could not only identify the motion tasks [9] but also distinguish motion phases [10].”
BackgroundFunctional force stimulation alters motor neuron discharge patterns
Xu, Y., Du, Z., Cheng, A., Lin, R., Wang, K., Jin, Y., Dai, C., & Xu, L. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1293017 · Cited by 2
Relevance Of Artificial Intelligence In Healthcare: An Exhaustive Review
Srikanth, K., Das, S., & Deb, M. (2024) · doi:10.53555/kuey.v30i4.3048 · Cited by 3
Tanzarella, S., Iacono, M., Donati, E., Farina, D., & Bartolozzi, C. (2022) · Research Square · doi:10.21203/rs.3.rs-1465054/v1 · Cited by 2
Self-citationOn-line decomposition of iEMG signals using GPU-implemented Bayesian filtering
Yu, T. (2019) · theses.fr (ABES) · doi:10.70675/396d1389zcafez4cddz8277za98b26996adf · Cited by 2
ATARO: A Muscle-Driven Biorobotic Arm to Investigate Healthy and Impaired Motor Control
Wochner, I., Nadler, T., Stollenmaier, K., Pley, C., Ilg, W., Wolfen, S., Schmitt, S., & Haeufle, D. F. B. (2024) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob60516.2024.10719710 · Cited by 1
“Note, that while EMG-driven biorobots have been used as an alternative to bio-inspired control strategies [19], they do not allow for the effective investigation of motor control hypotheses.”
BackgroundYu, T., Muceli, S., Akhmadeev, K., Carpentier, É. L., Aoustin, Y., & Farina, D. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3556853 · Cited by 2
Self-citationEffects of blood flow restriction on motoneurons synchronization
Taleshi, M., Bubeck, F., Gizzi, L., & Vujaklija, I. (2025) · Frontiers in Neural Circuits · doi:10.3389/fncir.2025.1561684 · Cited by 1
Self-citation
Metadata
- Authors
- Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C.
- Affiliations
- Universitätsmedizin Göttingen (DE)
- University of Waterloo (CA)
- Medical University of Vienna (AT)
- University of Florida (US)
- Corresponding author
- Farina, Dario
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2017-02-06
- Volume
- 1
- Issue
- 2
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2587122088
- Cited by
- 359
- References
- 51
- Citations by year
- 2026: 19 · 2025: 52 · 2024: 38 · 2023: 39 · 2022: 43 · 2021: 56 · 2020: 35 · 2019: 35 · 2018: 31 · 2017: 11
- FWCI
- 13.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- University of Twente Research Information (publishedVersion, other-oa)
- Institutional Research Information System (Università degli Studi di Brescia) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- European Commission (HORIZON2020, 702491)
- Bundesministerium für Wissenschaft, Forschung und Wirtschaft
- Defense Advanced Research Projects Agency (N66001-15-1-4054)
- Advanced Research Projects Agency
- FP7 Ideas: European Research Council (267888)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- human-machine interaction, spinal motoneurons, targeted muscle reinnervation, upper limb prosthesis, amputation, offline control, pattern recognition, musculoskeletal modeling, electromyography, neural decoding
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.