The DOI matches its Crossref record; 231 of the 231 references it cites were found in a registry or an index.
Glial responses to implanted electrodes in the brain
Open accessAbstract
The use of implants that can electrically stimulate or record electrophysiological or neurochemical activity in nervous tissue is rapidly expanding. Despite remarkable results in clinical studies and increasing market approvals, the mechanisms underlying the therapeutic effects of neuroprosthetic and neuromodulation devices, as well as their side effects and reasons for their failure, remain poorly understood. A major assumption has been that the signal-generating neurons are the only important target cells of neural-interface technologies. However, recent evidence indicates that the supporting glial cells remodel the structure and function of neuronal networks and are an effector of stimulation-based therapy. Here, we reframe the traditional view of glia as a passive barrier, and discuss their role as an active determinant of the outcomes of device implantation. We also discuss the implications that this has on the development of bioelectronic medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The fibrotic capsule forming around the implant not only damages and displaces the target neuronal tissue, but also forms a high-impedance layer that dampens the weak electrical signals produced by neurons and dissipates stimulating electrode currents.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite these differences, the general principles underlying FBR and the consequences (formation of a fibrotic capsule, inflammatory damage to the surrounding tissue) still apply (Polikov et al., 2005; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The fibrotic capsule forming around the implant not only damages and displaces the target neuronal tissue, but also forms a high-impedance layer that dampens the weak electrical signals produced by neurons and dissipates stimulating electrode currents.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“FBR is currently the key culprit behind chronically-implanted neuroprosthetic implant failure (Polikov et al., 2005; Salatino et al., 2017), and poses a major hurdle to the clinical translation of new neuroprosthetic technologies.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Flexible implants in general show improved tissue compatibility compared to stiffer equivalents, minimizing trauma and FBR arising from shear damage (Lacour et al., 2016; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measured
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“FBR occurs in response to any material that is implanted into the body (Anderson et al., 2008; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Material stiffness also greatly contributes to FBR, with softer materials (closer in stiffness to that of biological tissues) generating less mechanical trauma and therefore less FBR (Lacour et al., 2016; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
In the citing paper
“It has been shown that all biocompatible materials used so far provoke an inflammatory response and some degree of foreign body reaction [174,175].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [175]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strogatz, S. H. (2001) · Nature · doi:10.1038/35065725 · Cited by 8,236
Neurotoxic reactive astrocytes are induced by activated microglia
Liddelow, S. A., Guttenplan, K. A., Clarke, L. E., Bennett, F. C., Bohlen, C. J., Schirmer, L., Bennett, M. L., Münch, A. E., Chung, W.-S., Peterson, T. C., et al. (2017) · Nature · doi:10.1038/nature21029 · Cited by 7,971 · cited 1×
“The diversity of their roles is reflected in the recent identification of distinct subclasses of astrocytes that are characterized by differences in gene expression, function and reactive states during CNS injury 4,22–24 .”
Ionic channels of excitable membranes
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 7,134
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,710
A perivascular origin for mesenchymal stem cells in multiple human organs
Crisan, M., Yap, S., Casteilla, L., Chen, C.-W., Corselli, M., Park, T. S., Andriolo, G., Sun, B., Zheng, B., Zhang, L., et al. (2008) · Cell Stem Cell · doi:10.1016/j.stem.2008.07.003 · Cited by 3,991 · cited 1×
“It has been proposed that these cells have reparative potential through association with neurogenic niches 225,226 .”
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,667
Mechanisms underlying inflammation in neurodegeneration
Glass, C. K., Saijo, K., Winner, B., Marchetto, M. C., & Gage, F. H. (2010) · Cell · doi:10.1016/j.cell.2010.02.016 · Cited by 3,580
Cahoy, J. D., Emery, B., Kaushal, A., Foo, L. C., Zamanian, J. L., Christopherson, K. S., Xing, Y., Lubischer, J. L., Krieg, P. A., Krupenko, S. A., et al. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4178-07.2008 · Cited by 3,129
Neurodegenerative Disorders: Parkinson's Disease and Huntington's Disease
Hague, S., Klaffke, S., & Bandmann, O. (2006) · IMPERIAL COLLEGE PRESS eBooks · doi:10.1142/9781860948961_0007 · Cited by 2,767
Molecular dissection of reactive astrogliosis and glial scar formation
Sofroniew, M. V. (2009) · Trends in Neurosciences · doi:10.1016/j.tins.2009.08.002 · Cited by 2,594
Research works printed but not linked: 1
- Humphrey, D. R. & Schmidt, E. M. in Neurophysiological Techniques Vol. II (eds Boulton, A. A., Baker, G. B. & Vanderwolf, C. H.) 1–64 (Humana Press, New York, 1990).
Cited by
Sorted by citations
Items 601–644 of 644
Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Sridhar, K., Evers, J., Trotier, A., Biggs, M. J. P., & Lowery, M. M. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202503893
Material Damage to Multielectrode Arrays after Electrolytic Lesioning is in the NoisePreprint
Tor, A., Clarke, S. E., Bray, I. E., & Nuyujukian, P. (2026) · eLife · doi:10.7554/elife.106452.2
Tseng, Y., Jeakle, E. N., Javed, M., Krishnan, R. G., Smith, T. J., Lee, Y., Dhananjayan, S., George, S. M., Kalairaj, M. S., Zuaiter, A. H., et al. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505422
In Search for Biomarkers Reflecting Neural Implant-Induced Tissue Response DynamicsPreprint
Sharbatian, A., Joseph, K., Hofmann, U., Coenen, V., Stieglitz, T., & Vajari, D. A. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.19.712876
Poulkouras, R. (2022) · theses.fr (ABES) · doi:10.70675/18e3c078z78a1z4e5czbd7dz301fcc213f06
Hands-free control of an assistive robotic arm for high-level paralysis
Hasse, B. A., Ibarra, M. A., Alfaleh, J. A., Gin, D., Sheets, D. E. G., Thompson‐Mazzeo, A., & Fuglevand, A. J. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-02004-8
Lu, Y., Zhang, Z., & Peng, G. (2026) · Biomedical engineering · doi:10.5772/intechopen.1015791
Tang, G. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-38398-3_20
Tor, A., Clarke, S. J., Bray, I. E., & Nuyujukian, P. (2026) · eLife · doi:10.7554/elife.106452.3.sa2
Artem, I., Ma, H. F., Li, F. H., Chen, Z., Xu, M., YU, C., Li, R. K., Wu, J., & He, F. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.17.733032
Grundfest, D., Kim, K., Wang, Q., Yonza, A. K. I., Podsiadlo, J. T., Tao, L., zhang, X., Kucharz, K., Zhang, Y., Han, A., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae829c
Ultra-flexible wireless endovascular stimulator for cortical simulation
Tai, Y.-D., Villalobos, J., Wickramasinghe, N., Xin, H., Widdicombe, B., Unnithan, R. R., Grayden, D. B., & John, S. E. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae857c
Kim, W., Kim, Y., Yoo, H., & Lee, E. K. (2026) · Discover Nano · doi:10.1186/s11671-026-04790-5 · Cited by 2
Ma, J., Shao, M., Liu, J. J., Ma, N., Tang, Y., Wang, L., Xu, X., Qu, W., & Zhang, W. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.6c02118
Deep brain stimulation and neuroimmune mechanisms in major depressive disorder
Zhou, L., Saw, Y. L., Aquili, L., Kocabıçak, E., Temel, Y., Zhang, Y., Lu, J., Kalueff, A. V., Lu, Z., Tang, X., et al. (2026) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2026.111851
Smith, T. J., Srinivasan, H., Vargas, S. L., Khajehzadeh, M., Jeakle, E. N., Kumara, S. T., Jiang, M. S., Ogundipe, A., Villafranca, L. R., Kaul, M., et al. (2026) · Journal of Neurophysiology · doi:10.1152/jn.00047.2026
An Orthogonal Near-Infrared Optical Switch for Wireless Neuromodulation in Freely Behaving Mice
Xie, Z., Pan, L., Hua, Y., Hou, B., Xiang, P., Wu, Y. C., Shan, S., Yan, X., Tian, F., Chen, Y., et al. (2026) · Journal of the American Chemical Society · doi:10.1021/jacs.6c07856
An all-hydrogel fiber neural electrode array shrinks to the scale of neurons
Wu, S., Zhu, M., & Jiang, S. (2026) · Matter · doi:10.1016/j.matt.2026.102946
Chen, Z., Tang, Y., Zhang, S., Li, X., Li, H., Zhao, W., Zou, S., Lin, H., Gong, W., Si, K., et al. (2026) · Soft Science · doi:10.20517/ss.2026.68
Luo, Y., Zhou, Z., Wei, X., Ye, Y., & Sun, L. (2026) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems69704.2026.11633639
Sarvestani, F. S., Yaghobi, R., Maharlooei, M. K., Golshan, M., & Karimi, M. H. (2026) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.70215
Long-term stability of cellular-resolution brain-computer interface recordings after strokePreprint
Utzschmid, A., Terlau, J., Held, L. M., Schiffl, L. F., Chen, H., Alkan, G., Favero, P., Wagner, A., Gempt, J., Meyer, B., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.09.742157
Mo, F., Zhao, X., Xu, Y., Tang, C., Zhang, D., Li, S., Chen, D., Li, W., Song, Z., & He, S. (2026) · iScience · doi:10.1016/j.isci.2026.117268
Conformal mechanics of serpentine meshes for millimeter-scale neural probes
Batay, S., Zhou, Y., Pathirana, P. V., Seymour, J. P., & Avila, R. O. (2026) · Mechanics of Materials · doi:10.1016/j.mechmat.2026.105860
Kristiansen, A. (2026) · Research Square · doi:10.21203/rs.3.rs-10977875/v1
Closed-Loop Neuroprosthetics: Advancing Long-Term Solutions for Brain-Level Function Restoration
Malga, C., & Scholp, A. J. (2026) · Cureus · doi:10.7759/cureus.116352
Beyond electrical stimulation: toward neurotransmitter-mediated synaptic prostheses
Faber, P., & Krukiewicz, K. (2026) · Biomedical Materials Science · doi:10.1186/s44495-026-00010-5
Pang, J., Zhu, W., He, X., Li, X., Zhu, D., Qiu, W., Wu, M., Cao, Y., & Pei, R. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182314
BioNICs: Biomaterial-enabled neural interfaces with closed-loop control for brain disorders
Ju, Y., Dou, Z., Yang, Y., & Yang, F. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100167
A multiscale dynamical framework for continuity-preserving brain replacement
Neukart, F. (2026) · Biosystems · doi:10.1016/j.biosystems.2026.105958
Soft and Transient Bioelectronics Enabled by Polymer‐Free Ti 3 C 2 T x MXene Hydrogels
Garg, R., Laimo, F. A., Ippolito, S., Upadhyay, P., Averbeck, S. R., Boufidis, D., Assenmacher, C., Adewole, D. O., Panigrahy, S. N., Mohammadlou, B. S., et al. (2026) · Advanced Materials · doi:10.1002/adma.75137
Huo, M., Xue, Z., Sheng, Y., & Li, S. (2026) · Frontiers in Materials · doi:10.3389/fmats.2026.1969087
Liu, S., Huang, Y., & He, Q. Z. (2026) · ACS Nano Medicine · doi:10.1021/acsnanomed.6c00229
Zhao, Q., Peng, M., Wang, M., & Du, X. (2026) · Polymer science & technology. · doi:10.1021/polymscitech.6c00145
Fatima, S. M., Rahman, M. T., Mostaert, B. J., Razu, I., Hunger, B., Afrin, S., Haque, S. N., Khan, N. A., Zhang, Z., Claussen, A. D., et al. (2026) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2026.1895870
赵博识, Han, L., Zhao, Z., Li, X., Jia, K., & Zhang, T. (2026) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn69854.2026.11729022
The Development and Evolution of Substrate Materials for Brain–Computer Interfaces
Ji, J., Gao, Y., Liu, J., Tian, M., & Wei, Y. (2026) · Polymers · doi:10.3390/polym18202569
Sun, M., Ma, X., Wang, X., Bai, B., Wang, J., Wang, H., Wang, Y., Huang, L., & Tang, J. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71870
Elvira, R., Wu, Y.-C., Tan, E., & Zhou, Z. D. (2026) · Human Brain · doi:10.15302/hb.2026.0001
Kim, E., Kim, E., Lee, J., Jeong, I., Hong, Y., Oh, M., Lee, S., & Park, J. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71933
Membrane‐Targeted Nanoparticles for Neuronal Photomodulation
Escobar, A., Sánchez‐Iglesias, A., Bello, D., Barriga, M. F., Ascensión, A. M., Rodríguez-Gómez, L., Otaegui‐Bichot, D., Gil-Bea, F. J., Carril, M., & Grzelczak, M. (2026) · Advanced Science · doi:10.1002/advs.78575
Co-adaptive brain-computer interfaces: From signal processing to AI-driven dual-learner architecture
Lu, W. (2026) · AIP conference proceedings · doi:10.1063/12.0047168
Wang, S., León, S. E. D., Nadarajah, A., Goris, T., Ganesan, K., Jalilinejad, N., Jung, Y. J., Higham, S. J., Garrett, D. J., Ibbotson, M. R., et al. (2026) · Diamond and Related Materials · doi:10.1016/j.diamond.2026.114358
Metadata
- Authors
- Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K.
- Affiliations
- Michigan State University (US)
- Mayo Clinic (US)
- University of Pittsburgh (US)
- Corresponding author
- Purcell, Erin K.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-11-10
- Volume
- 1
- Issue
- 11
- Pages
- 862-877
- ISSN
- 2157-846X (ISSN-L)
- PMC
- PMC6261524
- OpenAlex
- W2765960015
- Cited by
- 642
- References
- 231
- Citations by year
- 2026: 77 · 2025: 110 · 2024: 92 · 2023: 95 · 2022: 68 · 2021: 76 · 2020: 61 · 2019: 38 · 2018: 24 · 2017: 1
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Update notices
- correction (2017-12-07)
- Open access
- green
- europepmc.org
- Licence
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Grainger Foundation
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (R03NS095202, R21NS094900, R01NS094396)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- glial cells, implanted electrodes, neuroprosthetics, neuromodulation, neural interfaces, device implantation outcomes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review