The DOI matches its Crossref record; 231 of the 231 references it cites were found in a registry or an index.
Glial responses to implanted electrodes in the brain
Open accessAbstract
The use of implants that can electrically stimulate or record electrophysiological or neurochemical activity in nervous tissue is rapidly expanding. Despite remarkable results in clinical studies and increasing market approvals, the mechanisms underlying the therapeutic effects of neuroprosthetic and neuromodulation devices, as well as their side effects and reasons for their failure, remain poorly understood. A major assumption has been that the signal-generating neurons are the only important target cells of neural-interface technologies. However, recent evidence indicates that the supporting glial cells remodel the structure and function of neuronal networks and are an effector of stimulation-based therapy. Here, we reframe the traditional view of glia as a passive barrier, and discuss their role as an active determinant of the outcomes of device implantation. We also discuss the implications that this has on the development of bioelectronic medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The fibrotic capsule forming around the implant not only damages and displaces the target neuronal tissue, but also forms a high-impedance layer that dampens the weak electrical signals produced by neurons and dissipates stimulating electrode currents.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite these differences, the general principles underlying FBR and the consequences (formation of a fibrotic capsule, inflammatory damage to the surrounding tissue) still apply (Polikov et al., 2005; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The fibrotic capsule forming around the implant not only damages and displaces the target neuronal tissue, but also forms a high-impedance layer that dampens the weak electrical signals produced by neurons and dissipates stimulating electrode currents.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“FBR is currently the key culprit behind chronically-implanted neuroprosthetic implant failure (Polikov et al., 2005; Salatino et al., 2017), and poses a major hurdle to the clinical translation of new neuroprosthetic technologies.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Flexible implants in general show improved tissue compatibility compared to stiffer equivalents, minimizing trauma and FBR arising from shear damage (Lacour et al., 2016; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measured
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“FBR occurs in response to any material that is implanted into the body (Anderson et al., 2008; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Material stiffness also greatly contributes to FBR, with softer materials (closer in stiffness to that of biological tissues) generating less mechanical trauma and therefore less FBR (Lacour et al., 2016; Salatino et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Salatino et al., 2017
In the citing paper
“It has been shown that all biocompatible materials used so far provoke an inflammatory response and some degree of foreign body reaction [174,175].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [175]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strogatz, S. H. (2001) · Nature · doi:10.1038/35065725 · Cited by 8,236
Neurotoxic reactive astrocytes are induced by activated microglia
Liddelow, S. A., Guttenplan, K. A., Clarke, L. E., Bennett, F. C., Bohlen, C. J., Schirmer, L., Bennett, M. L., Münch, A. E., Chung, W.-S., Peterson, T. C., et al. (2017) · Nature · doi:10.1038/nature21029 · Cited by 7,971 · cited 1×
“The diversity of their roles is reflected in the recent identification of distinct subclasses of astrocytes that are characterized by differences in gene expression, function and reactive states during CNS injury 4,22–24 .”
Ionic channels of excitable membranes
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 7,134
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,710
A perivascular origin for mesenchymal stem cells in multiple human organs
Crisan, M., Yap, S., Casteilla, L., Chen, C.-W., Corselli, M., Park, T. S., Andriolo, G., Sun, B., Zheng, B., Zhang, L., et al. (2008) · Cell Stem Cell · doi:10.1016/j.stem.2008.07.003 · Cited by 3,991 · cited 1×
“It has been proposed that these cells have reparative potential through association with neurogenic niches 225,226 .”
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,667
Mechanisms underlying inflammation in neurodegeneration
Glass, C. K., Saijo, K., Winner, B., Marchetto, M. C., & Gage, F. H. (2010) · Cell · doi:10.1016/j.cell.2010.02.016 · Cited by 3,580
Cahoy, J. D., Emery, B., Kaushal, A., Foo, L. C., Zamanian, J. L., Christopherson, K. S., Xing, Y., Lubischer, J. L., Krieg, P. A., Krupenko, S. A., et al. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4178-07.2008 · Cited by 3,129
Neurodegenerative Disorders: Parkinson's Disease and Huntington's Disease
Hague, S., Klaffke, S., & Bandmann, O. (2006) · IMPERIAL COLLEGE PRESS eBooks · doi:10.1142/9781860948961_0007 · Cited by 2,767
Molecular dissection of reactive astrogliosis and glial scar formation
Sofroniew, M. V. (2009) · Trends in Neurosciences · doi:10.1016/j.tins.2009.08.002 · Cited by 2,594
Research works printed but not linked: 1
- Humphrey, D. R. & Schmidt, E. M. in Neurophysiological Techniques Vol. II (eds Boulton, A. A., Baker, G. B. & Vanderwolf, C. H.) 1–64 (Humana Press, New York, 1990).
Cited by
Sorted by citations
Items 101–200 of 644
Long-term In Vivo Monitoring of Chemicals with Fiber Sensors
Wang, J., Wang, L., Feng, J., Tang, C., Sun, X., & Peng, H. (2021) · Advanced Fiber Materials · doi:10.1007/s42765-020-00061-9 · Cited by 62
Farì, G., Lunetti, P., Pignatelli, G., Raele, M. V., Cera, A., Mintrone, G., Ranieri, M., Megna, M., & Capobianco, L. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222111632 · Cited by 64
Higgins, S. G., Fiego, A. L., Patrick, I., Creamer, A., & Stevens, M. M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000384 · Cited by 64
Ramezani, M., Kim, J.-H., Liu, X., Ren, C., Alothman, A., De-Eknamkul, C., Wilson, M. N., Cubukcu, E., Gilja, V., Komiyama, T., et al. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01576-z · Cited by 66
Ultracompliant Hydrogel‐Based Neural Interfaces Fabricated by Aqueous‐Phase Microtransfer Printing
Huang, W., Ong, X. C., Kwon, I. S., Gopinath, C., Fisher, L. E., Wu, H., Fedder, G. K., Gaunt, R. A., & Bettinger, C. J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801059 · Cited by 61
Flexible and Implantable Polyimide Aptamer-Field-Effect Transistor Biosensors
Zhao, C., Man, T., Cao, Y. F., Weiss, P. S., Monbouquette, H. G., & Andrews, A. M. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01909 · Cited by 61
Nanotransducers for wireless neuromodulation
Li, X., Xiong, H., Rommelfanger, N. J., Xu, X., Youn, J., Slesinger, P. A., Hong, G., & Qin, Z. (2021) · Matter · doi:10.1016/j.matt.2021.02.012 · Cited by 61
Principles and applications of sono-optogenetics
Yang, F., Kim, S., Wu, X., Cui, H., Hahn, S. K., & Hong, G. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114711 · Cited by 61
Defining Surgical Terminology and Risk for Brain Computer Interface Technologies
Leuthardt, E. C., Moran, D. W., & Mullen, T. R. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.599549 · Cited by 62
Bierman, R. D., Safarians, G., Huang, J., Rajput, B., Chen, J. Y., Wang, Z. Z., & Seidlits, S. K. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202101577 · Cited by 58
Toward a New Generation of Bio-Scaffolds for Neural Tissue Engineering: Challenges and Perspectives
Villanueva‐Flores, F., Garcia-Atutxa, I., Santos, A., & Armendáriz‐Borunda, J. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15061750 · Cited by 57
Interpenetrating PAA-PEDOT conductive hydrogels for flexible skin sensors
Fu, F., Wang, J., & Yu, J. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc01578h · Cited by 57
A Nanozyme‐Based Electrode for High‐Performance Neural Recording
Liu, S., Wang, Y., Zhao, Y., Liu, L., Sun, S., Zhang, S., Liu, H., Liu, S., Li, Y., Yang, F., et al. (2023) · Advanced Materials · doi:10.1002/adma.202304297 · Cited by 55
Triboelectric‐Responsive Drug Delivery Hydrogel for Accelerating Infected Wound Healing
Qin, X., Shi, H., Wen, Z., Chu, B., Li, H., Wang, H., He, Y., & Sun, X. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303474 · Cited by 55
Nanotransducer-Enabled Deep-Brain Neuromodulation with NIR-II Light
Wu, X., Yang, F., Cai, S., Pu, K., & Hong, G. (2023) · ACS Nano · doi:10.1021/acsnano.2c12068 · Cited by 54
Jiang, S., Wu, X., Yang, F., Rommelfanger, N. J., & Hong, G. (2023) · Nature Protocols · doi:10.1038/s41596-023-00895-8 · Cited by 54
Recent advances in neural interfaces—Materials chemistry to clinical translation
Bettinger, C. J., Ecker, M., Kozai, T. D. Y., Malliaras, G. G., Meng, E. F., & Voit, W. (2020) · MRS Bulletin · doi:10.1557/mrs.2020.195 · Cited by 56
Self-citationThe ultra-thin, minimally invasive surface electrode array NeuroWeb for probing neural activity
Lee, J. M., Pyo, Y., Kim, Y. J., Hong, J. H., Jo, Y., Choi, W., Lin, D., & Park, H. (2023) · Nature Communications · doi:10.1038/s41467-023-42860-9 · Cited by 53
Accurate Localization of Linear Probe Electrode Arrays across Multiple Brains
Liu, L. D., Chen, S., Hou, H., West, S. J., Faulkner, M., Economo, M. N., Li, N., & Svoboda, K. (2021) · eNeuro · doi:10.1523/eneuro.0241-21.2021 · Cited by 53
Furlani, F., Montanari, M., Sangiorgi, N., Saracino, E., Campodoni, E., Sanson, A., Benfenati, V., Tampieri, A., Panseri, S., & Sandri, M. (2022) · Biomaterials Science · doi:10.1039/d2bm00116k · Cited by 52
How is flexible electronics advancing neuroscience research?
Chen, Y., Rommelfanger, N. J., Mahdi, A. I., Wu, X., Keene, S. T., Obaid, A., Salleo, A., Wang, H., & Hong, G. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120559 · Cited by 58
Novel diamond shuttle to deliver flexible neural probe with reduced tissue compression
Na, K., Sperry, Z. J., Lu, J., Vöröslakos, M., Parizi, S. S., Bruns, T. M., Yoon, E., & Seymour, J. P. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0149-z · Cited by 51
Engineering strategies towards overcoming bleeding and glial scar formation around neural probes
Otte, E., Vlachos, A., & Asplund, M. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03567-9 · Cited by 54
Implantable Soft Neural Electrodes of Liquid Metals for Deep Brain Stimulation
Kwon, Y. W., Kim, E., Koh, C. S., Park, Y., Hong, Y., Lee, S., Lee, J., Kim, T. J., Mun, W., Min, S. H., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c18030 · Cited by 51
A guide towards long-term functional electrodes interfacing neuronal tissue
Renz, A. F., Reichmuth, A. M., Stauffer, F., Thompson‐Steckel, G., & Vörös, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae0c2 · Cited by 54
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
Lee, J. Y., Park, S., Kim, Y., Cho, Y. U., Park, J., Hong, J.-H., Kim, K., Shin, J., Ju, J. E., Min, I. S., et al. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00219-y · Cited by 53
Hydrogel facilitated bioelectronic integration
Vo, R., Hsu, L. H. H., & Jiang, X. (2020) · Biomaterials Science · doi:10.1039/d0bm01373k · Cited by 49
Strategies for interface issues and challenges of neural electrodes
Liang, C., Liu, Y., Lu, W., Tian, G., Zhao, Q., Yang, D., Sun, J. W., & Qi, D. (2022) · Nanoscale · doi:10.1039/d1nr07226a · Cited by 49
Won, C., Jeong, U., Lee, S., Lee, M., Kwon, C., Cho, S., Yoon, K., Lee, S.-M., Chun, D. W., Cho, I., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202205145 · Cited by 48
Bergeron, D., Iorio‐Morin, C., Bonizzato, M., Lajoie, G., Gaucher, N. O., Racine, É., & Weil, A. G. (2023) · Journal of Child Neurology · doi:10.1177/08830738231167736 · Cited by 50
Nanoenabled Direct Contact Interfacing of Syringe-Injectable Mesh Electronics
Lee, J. M., Hong, G., Lin, D., Schuhmann, T. G., Sullivan, A. T., Viveros, R. D., Park, H., & Lieber, C. M. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b03019 · Cited by 48
Milosevic, L., Kalia, S. K., Hodaie, M., Lozano, A. M., Popović, M. R., Hutchison, W. D., & Lankarany, M. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.04.022 · Cited by 47
Maiolo, L., Guarino, V., Saracino, E., Convertino, A., Melucci, M., Muccini, M., Ambrosio, L., Zamboni, R., & Benfenati, V. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202001268 · Cited by 49
Spatiotemporal patterns of gene expression around implanted silicon electrode arrays
Thompson, C. H., Saxena, A., Heelan, N., Salatino, J. W., & Purcell, E. K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf2e6 · Cited by 47
Self-citationSzymanski, L. J., Kellis, S., Liu, C. Y., Jones, K. T., Andersen, R. A., Commins, D., Lee, B., McCreery, D. B., & Miller, C. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac127e · Cited by 48
Carnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46
In vivo spatiotemporal dynamics of astrocyte reactivity following neural electrode implantation
Savya, S. P., Li, F., Lam, S., Wellman, S. M., Stieger, K. C., Chen, K., Eles, J. R., & Kozai, T. D. Y. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121784 · Cited by 46
Self-citationMariello, M., & Proctor, C. M. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400797 · Cited by 50
Gels, jets, mosquitoes, and magnets: a review of implantation strategies for soft neural probes
Apollo, N. V., Murphy, B. B., Prezelski, K., Driscoll, N., Richardson, A. G., Lucas, T. H., & Vitale, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abacd7 · Cited by 47
Open and remotely accessible Neuroplatform for research in wetware computing
Jordan, F. D., Kutter, M., Comby, J.-M., Brozzi, F., & Kurtys, E. (2024) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2024.1376042 · Cited by 45
Malekoshoaraie, M. H., Wu, B., Krahe, D. D., Ahmed, Z., Pupa, S., Jain, V., Cui, X. T., & Chamanzar, M. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00685-6 · Cited by 48
Three-dimensional micro- and nanomanufacturing techniques for high-fidelity wearable bioelectronics
Fan, P., Liu, Y., Pan, Y., Ying, Y. B., & Ping, J. F. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00174-6 · Cited by 46
Tang, K. W. K., Jeong, J., Hsieh, J.-C., Yao, M., Ding, H. Q., Wang, W., Liu, X., Pyatnitskiy, I., He, W., Moscoso-Barrera, W. D., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-60181-x · Cited by 45
Tissue-like Neural Probes for Understanding and Modulating the Brain
Hong, G., Viveros, R. D., Zwang, T. J., Yang, X., & Lieber, C. M. (2018) · Biochemistry · doi:10.1021/acs.biochem.8b00122 · Cited by 46
Bedell, H. W., Schaub, N. J., Capadona, J. R., & Ereifej, E. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.11.017 · Cited by 45
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Wellman, S. M., Guzman, K., Stieger, K. C., Brink, L. E., Sridhar, S., Dubaniewicz, M. T., Li, L., Cambi, F., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119842 · Cited by 44
Self-citationCeramic packaging in neural implants
Shen, K., & Maharbiz, M. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd683 · Cited by 47
Dervan, A. G., Franchi, A., Almeida-González, F. R., Dowling, J. K., Kwakyi, O., McCoy, C. E., O’Brien, F. J., & Hibbitts, A. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13122161 · Cited by 46
Eles, J. R., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119767 · Cited by 44
Self-citationAdvances in large-scale electrophysiology with high-density microelectrode arrays
Schröter, M. S., Cardes, F., Bui, C.-V. H., Dodi, L. D., Gänswein, T., Bartram, J., Sadiraj, L., Hornauer, P., Kumar, S. S., Pascual-Garcia, M., et al. (2025) · Lab on a Chip · doi:10.1039/d5lc00058k · Cited by 48
Yan, J. S., Orecchioni, M., Vitale, F., Coco, J. A., Duret, G., Antonucci, S., Pamulapati, S. S., Taylor, L. W., Dewey, O. S., Sante, M. D., et al. (2020) · Carbon · doi:10.1016/j.carbon.2020.10.077 · Cited by 43
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Yang, Q., Wu, B., Eles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2020) · Advanced Biosystems · doi:10.1002/adbi.201900287 · Cited by 43
Self-citationSun, F., Shen, H., Yang, Q., Yuan, Z., Chen, Y., Guo, W., Wang, Y., Yang, L., Bai, Z., Liu, Q., et al. (2023) · Advanced Materials · doi:10.1002/adma.202210018 · Cited by 43
Wang, Y., Han, M., Jing, L., Jia, Q., Lv, S., Xu, Z., Liu, J., & Cai, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116837 · Cited by 42
Anisotropically Conductive Hydrogels with Directionally Aligned PEDOT:PSS in a PVA Matrix
Kim, Y.-W., Park, J., Park, C. S., Na, H., Kang, Y., Lee, W., & Sun, J. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c16094 · Cited by 42
Wellman, S. M., Cambi, F., & Kozai, T. D. Y. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.08.046 · Cited by 43
Self-citationMaclean, F. L., Ims, G. M., Horne, M. K., Williams, R. J., & Nisbet, D. R. (2018) · Advanced Materials · doi:10.1002/adma.201805209 · Cited by 41
Monolayer Graphene Coating of Intracortical Probes for Long‐Lasting Neural Activity Monitoring
Bourrier, A., Shkorbatova, P. Y., Bonizzato, M., Rey, E., Barraud, Q., Courtine, G., Othmen, R., Reita, V., Bouchiat, V., & Delacour, C. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801331 · Cited by 43
The neural tissue around SU-8 implants: A quantitative in vivo biocompatibility study
Márton, G., Tóth, E. Z., Wittner, L., Fiáth, R., Pinke, D., Orbán, G., Meszéna, D., Pál, I., Győri, E. L., Bereczki, Z., et al. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.110870 · Cited by 44
Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
Purcell, E. K., Becker, M., Guo, Y., Hara, S. A., Ludwig, K. A., McKinney, C., Monroe, E., Rechenberg, R., Rusinek, C. A., Saxena, A., et al. (2021) · Micromachines · doi:10.3390/mi12020128 · Cited by 41
Self-citationDeveloping an electrochemical sensor for the in vivo measurements of dopamine
Delmo, N., Mostafiz, B., Ross, A. E., Suni, J., & Peltola, E. (2023) · Sensors & Diagnostics · doi:10.1039/d2sd00230b · Cited by 42
Functional adhesive hydrogels for biological interfaces
Liu, C., Peng, K., Wu, Y., & Fu, F. (2023) · Smart Medicine · doi:10.1002/smmd.20230024 · Cited by 40
Fabbri, R., Scidà, A., Saracino, E., Conte, G., Kovtun, A., Candini, A., Kirdajová, D., Spennato, D., Marchetti, V., Lazzarini, C., et al. (2024) · Nature Nanotechnology · doi:10.1038/s41565-024-01711-4 · Cited by 40
Surface-Enhanced Raman Scattering Nanosensing and Imaging in Neuroscience
Boudries, R., Williams, H., Paquereau--Gaboreau, S., Bashir, S., Jodaylami, M. H., Chisanga, M., Trudeau, L., & Masson, J. (2024) · ACS Nano · doi:10.1021/acsnano.4c05200 · Cited by 43
Structural and functional properties of astrocytes on PCL based electrospun fibres
Saracino, E., Cirillo, V., Marrese, M., Guarino, V., Benfenati, V., Zamboni, R., & Ambrosio, L. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111363 · Cited by 40
Biopolymeric Coatings for Local Release of Therapeutics from Biomedical Implants
Talebian, S., Mendes, B. B., Conniot, J., Farajikhah, S., Dehghani, F., Li, Z.-Y., Bitoque, D. B., Silva, G. A., Naficy, S., Conde, J., et al. (2023) · Advanced Science · doi:10.1002/advs.202207603 · Cited by 39
Chronic stability of a neuroprosthesis comprising multiple adjacent Utah arrays in monkeys
Chen, X., Wang, F., Kooijmans, R. N., Klink, P. C., Boehler, C., Asplund, M., & Roelfsema, P. R. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ace07e · Cited by 45
Biohybrid neural interfaces: improving the biological integration of neural implants
Boulingre, M., Lara, R. P., & Green, R. A. (2023) · Chemical Communications · doi:10.1039/d3cc05006h · Cited by 41
Electrochemical methods for neural interface electrodes
Weltin, A., & Kieninger, J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac28d5 · Cited by 39
Gao, W., Yan, Z., Zhou, H., Xie, Y., Wang, H., Yang, J., Yu, J., Ni, C., Liu, P., Xie, M., et al. (2025) · Journal of Nanobiotechnology · doi:10.1186/s12951-025-03573-x · Cited by 38
Electrical Stimulation of Cells: Drivers, Technology, and Effects
Kadan-Jamal, K., Wronowski, F., Jin, A. T., Naegele, T. E., Montes, V. R., Tao, X., Dominguez‐Alfaro, A., Lee, C., & Malliaras, G. G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00468 · Cited by 39
Thompson, C. H., Riggins, T. E., Patel, P. R., Chestek, C. A., Li, W., & Purcell, E. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7030 · Cited by 38
Self-citationDalrymple, A. N., Huynh, M., Nayagam, B. A., Lee, C. D., Weiland, G. R., Petrossians, A., John, J., Whalen, J. J., Fallon, J. B., & Shepherd, R. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab933d · Cited by 38
Fully Implantable Wireless Cardiac Pacing and Sensing System Integrated with Hydrogel Electrodes
Chang, Z., Wang, B., Ren, Q., Nie, J., Guo, B., Lu, Y., Lu, X., Zhang, Y., Ji, D., Lv, Y., et al. (2024) · Advanced Science · doi:10.1002/advs.202401982 · Cited by 37
Liu, Z., Chen, J., Jo, M., Viola Vogel, B., Chen, J., Rogers, J. A., & Li, S. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00391-6 · Cited by 42
Graphene and graphene-related materials as brain electrodes
Xu, B., Pei, J., Feng, L., & Zhang, X. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb01795k · Cited by 37
Zhang, A., Loh, K. Y., Kadur, C. S., Michalek, L. F., Dou, J., Ramakrishnan, C., Bao, Z., & Deisseroth, K. A. (2023) · Science Advances · doi:10.1126/sciadv.adi1870 · Cited by 36
pH dependence of noble metals dissolution: Platinum
Martos, V. B., Stojanovski, K., Zlatar, M., Göllner, C., & Cherevko, S. (2024) · Electrochimica Acta · doi:10.1016/j.electacta.2024.144793 · Cited by 36
A wireless subdural-contained brain–computer interface with 65,536 electrodes and 1,024 channels
Jung, T., Zeng, N., Fabbri, J. D., Eichler, G., Li, Z., Zabeh, E., Das, A., Willeke, K. F., Wingel, K., Dubey, A., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01509-9 · Cited by 40
Electroresponsive Hydrogels for Therapeutic Applications in the Brain
Khan, Z. M., Wilts, E. M., Vlaisavljevich, E., Long, T. E., & Verbridge, S. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202100355 · Cited by 37
Printable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
Li, F., Gallego, J., Tirko, N. N., Greaser, J., Bashe, D., Patel, R., Shaker, E., Valkenburg, G. E. V., Alsubhi, A. S., Wellman, S. M., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-49709-9 · Cited by 38
Self-citationBjånes, D. A., Kellis, S., Nickl, R., Baker, B., Aflalo, T., Bashford, L., Chivukula, S., Fifer, M. S., Osborn, L. E., Christie, B., et al. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.02.030 · Cited by 37
Directed Neural Stem Cells Differentiation via Signal Communication with Ni–Zn Micromotors
Feng, Y., Gao, C., Xie, D., Liu, L., Chen, B., Liu, S., Yang, H., Gao, Z., Wilson, D. A., Tu, Y., et al. (2023) · Advanced Materials · doi:10.1002/adma.202301736 · Cited by 35
Wang, J., Wang, L., Yang, Y., Li, H., Huang, X., Liu, Z., Yu, S., Tang, C., Chen, J., Shi, X., et al. (2023) · Advanced Materials · doi:10.1002/adma.202309862 · Cited by 34
Mechanics Strategies for Implantation of Flexible Neural Probes
Zhang, S., Wang, C., Linghu, C., Wang, S., & Song, J. (2020) · Journal of Applied Mechanics · doi:10.1115/1.4047858 · Cited by 34
Hydrogels for 3D Neural Tissue Models: Understanding Cell-Material Interactions at a Molecular Level
Vallejo‐Giraldo, C., Genta, M., Cauvi, O., Goding, J. A., & Green, R. A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.601704 · Cited by 34
Recent advances in electronic devices for monitoring and modulation of brain
Kwon, Y. W., Jun, Y. S., Park, Y., Jang, J., & Park, J. (2021) · Nano Research · doi:10.1007/s12274-021-3476-y · Cited by 35
Semiconducting electrodes for neural interfacing: a review
Ahnood, A., Chambers, A., Gelmi, A. A., Yong, K., & Kavehei, O. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00830k · Cited by 33
3D-printed flexible neural probes for recordings at single-neuron level
Momin, M., Feng, L., Ahmed, S., Ren, J., Hossain, A., Zhang, S., & Zhou, T. (2024) · Device · doi:10.1016/j.device.2024.100519 · Cited by 33
Ultrasound Mediated Cellular Deflection Results in Cellular Depolarization
Vasan, A., Orosco, J., Magaram, U., Duque, M., Weiss, C., Tufail, Y., Chalasani, S. H., & Friend, J. R. (2021) · Advanced Science · doi:10.1002/advs.202101950 · Cited by 34
Structural and functional imaging of brains
Liu, Z., Zhu, Y. J., Zhang, L., Jiang, W., Liu, Y., Tang, Q., Cai, X., Li, J., Wang, L., Tao, C.-L., et al. (2022) · Science China Chemistry · doi:10.1007/s11426-022-1408-5 · Cited by 33
A soft, high-density neuroelectronic array
Seo, K. J., Hill, M., Ryu, J., Chiang, C., Rachinskiy, I., Qiang, Y., Jang, D., Trumpis, M., Wang, C., Viventi, J., et al. (2023) · npj Flexible Electronics · doi:10.1038/s41528-023-00271-2 · Cited by 33
Haley, R. M., Zuckerman, S. T., Dakhlallah, H., Capadona, J. R., von Recum, H. A., & Ereifej, E. S. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21103579 · Cited by 32
Chik, G. K. K., Xiao, N., Ji, X., Tsang, A. C. O., Leung, G., Zhang, S., Tin, C., & Chan, P. K. L. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200143 · Cited by 33
Fekete, Z., Zátonyi, A., Kaszás, A., Madarász, M., & Slézia, A. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00519-x · Cited by 33
Optimizing the Yield of Multi-Unit Activity by Including the Entire Spiking Activity
Drebitz, E., Schledde, B., Kreiter, A. K., & Wegener, D. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00083 · Cited by 31
Metadata
- Authors
- Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K.
- Affiliations
- Michigan State University (US)
- Mayo Clinic (US)
- University of Pittsburgh (US)
- Corresponding author
- Purcell, Erin K.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-11-10
- Volume
- 1
- Issue
- 11
- Pages
- 862-877
- ISSN
- 2157-846X (ISSN-L)
- PMC
- PMC6261524
- OpenAlex
- W2765960015
- Cited by
- 642
- References
- 231
- Citations by year
- 2026: 77 · 2025: 110 · 2024: 92 · 2023: 95 · 2022: 68 · 2021: 76 · 2020: 61 · 2019: 38 · 2018: 24 · 2017: 1
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Update notices
- correction (2017-12-07)
- Open access
- green
- europepmc.org
- Licence
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Grainger Foundation
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (R03NS095202, R21NS094900, R01NS094396)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- glial cells, implanted electrodes, neuroprosthetics, neuromodulation, neural interfaces, device implantation outcomes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review