Metal–polymer hybrid nanomaterials for plasmonic ultrafast hydrogen detection
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Hydrogen–air mixtures are highly flammable. Hydrogen sensors are therefore of paramount importance for timely leak detection during handling. However, existing solutions do not meet the stringent performance targets set by stakeholders, while deactivation due to poisoning, for example by carbon monoxide, is a widely unsolved problem. Here we present a plasmonic metal–polymer hybrid nanomaterial concept, where the polymer coating reduces the apparent activation energy for hydrogen transport into and out of the plasmonic nanoparticles, while deactivation resistance is provided via a tailored tandem polymer membrane. In concert with an optimized volume-to-surface ratio of the signal transducer uniquely offered by nanoparticles, this enables subsecond sensor response times. Simultaneously, hydrogen sorption hysteresis is suppressed, sensor limit of detection is enhanced, and sensor operation in demanding chemical environments is enabled, without signs of long-term deactivation. In a wider perspective, our work suggests strategies for next-generation optical gas sensors with functionalities optimized by hybrid material engineering.Sensing hydrogen by the change in plasmonic response upon metal hydride formation is safe, but trace gas poisoning and low sensitivity can occur. Here, a PdAu alloy/polymer sensor is poison resistant and can sense 3 ppm H2 with a response time of 1 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized Gradient Approximation Made Simple
Perdew, J. P., Burke, K., & Ernzerhof, M. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3865 · Cited by 215,824
Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set
Kresse, G., & Furthmüller, J. (1996) · Physical Review B · doi:10.1103/physrevb.54.11169 · Cited by 123,652
Projector augmented-wave method
Blöchl, P. E. (1994) · Physical Review B · doi:10.1103/physrevb.50.17953 · Cited by 92,732
From ultrasoft pseudopotentials to the projector augmented-wave method
Kresse, G., & Joubert, D. (1999) · Physical Review B · doi:10.1103/physrevb.59.1758 · Cited by 85,307
Kresse, G., & Furthmüller, J. (1996) · Computational Materials Science · doi:10.1016/0927-0256(96)00008-0 · Cited by 75,638
Special points for Brillouin-zone integrations
Monkhorst, H. J., & Pack, J. D. (1976) · Physical Review B · doi:10.1103/physrevb.13.5188 · Cited by 71,721
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Hübert, T., Boon-Brett, L., Black, G., & Banach, U. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2011.04.070 · Cited by 1,713
Hydrogen Sensors and Switches from Electrodeposited Palladium Mesowire Arrays
Favier, F., Walter, E. C., Zach, M. P., Benter, T., & Penner, R. M. (2001) · Science · doi:10.1126/science.1063189 · Cited by 1,385
The metal-hydrogen system: basic bulk properties
Fukai, Y. (2005) · Springer Series in Materials Science · doi:10.1007/3-540-28883-x · Cited by 1,197
Nanoantenna-enhanced gas sensing in a single tailored nanofocus
Liu, N., Tang, M. L., Hentschel, M., Giessen, H., & Alivisatos, A. P. (2011) · Nature Materials · doi:10.1038/nmat3029 · Cited by 950
Jeon, K.-J., Moon, H. R., Ruminski, A. M., Jiang, B., Kisielowski, C., Bardhan, R., & Urban, J. J. (2011) · Nature Materials · doi:10.1038/nmat2978 · Cited by 731
Nanoantenna-enhanced gas sensing in a single tailored nanofocus
Liu, N., Tang, M. L., Hentschel, M., Giessen, H., & Alivisatos, A. P. (2011) · CLEO:2011 - Laser Applications to Photonic Applications · doi:10.1364/cleo_at.2011.pdpc11 · Cited by 720
Hole–Mask Colloidal Lithography
Fredriksson, H., Alaverdyan, Y., Dmitriev, A., Langhammer, C., Sutherland, D. S., Zäch, M., & Kasemo, B. (2007) · Advanced Materials · doi:10.1002/adma.200700680 · Cited by 644
Self-citationThe role of palladium in a hydrogen economy
Adams, B. D., & Chen, A. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70143-2 · Cited by 565
Berland, K., & Hyldgaard, P. (2014) · Physical Review B · doi:10.1103/physrevb.89.035412 · Cited by 564
Hydrogen storage in Pd nanocrystals covered with a metal–organic framework
Li, G., Kobayashi, H., Taylor, J. M., Ikeda, R., Kubota, Y., Kato, K., Takata, M., Yamamoto, T., Toh, S., Matsumura, S., et al. (2014) · Nature Materials · doi:10.1038/nmat4030 · Cited by 482
Tittl, A., Mai, P., Taubert, R., Dregely, D., Liu, N., & Giessen, H. (2011) · Nano Letters · doi:10.1021/nl202489g · Cited by 446
In situ detection of hydrogen-induced phase transitions in individual palladium nanocrystals
Baldi, A., Narayan, T. C., Koh, A. L., & Dionne, J. A. (2014) · Nature Materials · doi:10.1038/nmat4086 · Cited by 336
Plasmonic Hydrogen Sensing with Nanostructured Metal Hydrides
Wadell, C., Syrenova, S., & Langhammer, C. (2014) · ACS Nano · doi:10.1021/nn505804f · Cited by 283
Self-citationAccelerating Palladium Nanowire H2 Sensors Using Engineered Nanofiltration
Koo, W.-T., Qiao, S., Ogata, A. F., Jha, G., Jang, J.-S., Chen, V. T., Kim, I.-D., & Penner, R. M. (2017) · ACS Nano · doi:10.1021/acsnano.7b04529 · Cited by 249
Yang, F., Kung, S.-C., Cheng, M., Hemminger, J. C., & Penner, R. M. (2010) · ACS Nano · doi:10.1021/nn101475c · Cited by 241
Hong, J., Lee, S., Seo, J., Pyo, S., Kim, J., & Lee, T. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/am5073645 · Cited by 233
Hydrogen Storage in Pd Nanodisks Characterized with a Novel Nanoplasmonic Sensing Scheme
Langhammer, C., Zorić, I., Kasemo, B., & Clemens, B. M. (2007) · Nano Letters · doi:10.1021/nl071664a · Cited by 226
Self-citationSyrenova, S., Wadell, C., Nugroho, F. A. A., Gschneidtner, T. A., Diaz Fernandez, Y. A., Nalin, G., Świtlik, D., Westerlund, F., Antosiewicz, T. J., Zhdanov, V. P., et al. (2015) · Nature Materials · doi:10.1038/nmat4409 · Cited by 203
Self-citationMagnesium as Novel Material for Active Plasmonics in the Visible Wavelength Range
Sterl, F., Strohfeldt, N., Walter, R., Griessen, R., Tittl, A., & Giessen, H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b03029 · Cited by 188
Effect of tacticity on permeation properties of poly(methyl methacrylate)
Min, K. E., & Paul, D. R. (1988) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.1988.090260507 · Cited by 123
Nugroho, F. A. A., Darmadi, I., Zhdanov, V. P., & Langhammer, C. (2018) · ACS Nano · doi:10.1021/acsnano.8b02835 · Cited by 122
Self-citationMultiyear Research, Development and Demonstration Plan
Eere (2012) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1219578 · Cited by 105
Transmission electron microscopy windows for nanofabricated structures
Grant, A. W., Hu, Q.-H., & Kasemo, B. (2004) · Nanotechnology · doi:10.1088/0957-4484/15/9/012 · Cited by 88
Ngene, P., Westerwaal, R. J., Sachdeva, S., Haije, W. G., de Smet, L. C. P. M., & Dam, B. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201406911 · Cited by 75
Self-citationYoo, H., Cho, S., Jeon, H., & Jung, H. (2015) · Analytical Chemistry · doi:10.1021/ac504367w · Cited by 75
Yip, H. K., Zhu, X., Zhuo, X., Jiang, R., Yang, Z., & Wang, J. (2017) · Advanced Optical Materials · doi:10.1002/adom.201700740 · Cited by 49
(2018) · Nature Materials · doi:10.1038/s41563-018-0129-y · Cited by 33
Cited by
Non-Noble Plasmonic Metal-Based Photocatalysts
Sayed, M., Yu, J., Liu, G., & Jaroniec, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00473 · Cited by 579
Darmadi, I., Nugroho, F. A. A., & Langhammer, C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02019 · Cited by 382
Self-citationChemiresistive Hydrogen Sensors: Fundamentals, Recent Advances, and Challenges
Koo, W.-T., Cho, H.-J., Kim, D.-H., Kim, Y. H., Shin, H., Penner, R. M., & Kim, I.-D. (2020) · ACS Nano · doi:10.1021/acsnano.0c05307 · Cited by 379
Dai, J., Ogbeide, O., Macadam, N., Sun, Q., Yu, W., Li, Y., Su, B.-L., Hasan, T., Huang, X., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00459a · Cited by 378
Sensing as the key to battery lifetime and sustainability
Huang, J., Boles, S. T., & Tarascon, J.-M. (2022) · Nature Sustainability · doi:10.1038/s41893-022-00859-y · Cited by 219
“Dealing with the field of energy, the use of the plasmonic approach for monitoring hydrogen insertion into the intermetallic compounds is worth mentioning 85 .”
Metadata
- Authors
- Nugroho, F. A. A., Darmadi, I., Cusinato, L., Susarrey-Arce, A., Schreuders, H., Bannenberg, L. J., da Silva Fanta, A. B., Kadkhodazadeh, S., Wagner, J. B., Antosiewicz, T. J., Hellman, A., Zhdanov, V. P., Dam, B., & Langhammer, C.
- Venue
- Nature Materials
- Published
- 2019-04-01
- Volume
- 18
- Issue
- 5
- Pages
- 489-495
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W2932081749
- Cited by
- 365
- References
- 36
- FWCI
- 15.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.