Optical-resolution photoacoustic microscopy with a needle-shaped beam
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Optical-resolution photoacoustic microscopy can visualize wavelength-dependent optical absorption at the cellular level. However, this technique suffers from a limited depth of field due to the tight focus of the optical excitation beam, making it challenging to acquire high-resolution images of samples with uneven surfaces or high-quality volumetric images without z scanning. To overcome this limitation, we propose needle-shaped beam photoacoustic microscopy, which can extend the depth of field to around a 28-fold Rayleigh length via customized diffractive optical elements. These diffractive optical elements generate a needle-shaped beam with a well-maintained beam diameter, a uniform axial intensity distribution and negligible sidelobes. The advantage of using needle-shaped beam photoacoustic microscopy is demonstrated via both histology-like imaging of fresh slide-free organs using a 266 nm laser and in vivo mouse-brain vasculature imaging using a 532 nm laser. This approach provides new perspectives for slide-free intraoperative pathological imaging and in vivo organ-level imaging. The use of a needle-shaped optical beam improves the depth of field for photoacoustic imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 2×
“As an emerging technology, photoacoustic microscopy (PAM) can directly image the distribution of intrinsic or extrinsic optical absorbers by detecting optical-absorption-induced acoustic signals 23,24 .”
BackgroundMethodInfluentialSelf-citationWide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829 · cited 1×
“Fourier ptychographic microscopy uses a simple configuration and adopts a wavefront correction strategy to extend the DOF computationally 11 .”
MethodA practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394 · cited 1×
“As an emerging technology, photoacoustic microscopy (PAM) can directly image the distribution of intrinsic or extrinsic optical absorbers by detecting optical-absorption-induced acoustic signals 23,24 .”
BackgroundSelf-citationRapid three-dimensional isotropic imaging of living cells using Bessel beam plane illumination
Planchon, T. A., Gao, L., Milkie, D. E., Davidson, M. W., Galbraith, J. A., Galbraith, C. G., & Betzig, E. (2011) · Nature Methods · doi:10.1038/nmeth.1586 · Cited by 1,112 · cited 1×
“In addition, many researchers have applied non-diffracting beams (for example, a Bessel beam or an Airy beam) for extended DOFs in microscopy 12–18 .”
BackgroundOptical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763 · cited 1×
“For high-resolution imaging, optical-resolution photoacoustic microscopy (OR-PAM) with a tight optical focus has been implemented 35,36 .”
Self-citationHigh-speed label-free functional photoacoustic microscopy of mouse brain in action
Yao, J., Wang, L., Yang, J.-M., Maslov, K. I., Wong, T. T. W., Li, L., Huang, C.-H., Zou, J., & Wang, L. V. (2015) · Nature Methods · doi:10.1038/nmeth.3336 · Cited by 716 · cited 1×
“Ben-efitting from the rich intrinsic contrasts in biological tissues, label-free PAM has been demonstrated in the imaging of various biological components, such as DNA/RNA 25–27 , cytochromes 28 , haemoglobin 29–31 , melanomas 32 and lipids 33,34 .”
BackgroundSelf-citationIsotropic three-dimensional super-resolution imaging with a self-bending point spread function
Jia, S., Vaughan, J. C., & Zhuang, X. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.13 · Cited by 542
Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed
Hu, S., Maslov, K., & Wang, L. V. (2011) · Optics Letters · doi:10.1364/ol.36.001134 · Cited by 429
Self-citationFast multicolor 3D imaging using aberration-corrected multifocus microscopy
Abrahamsson, S., Chen, J., Hajj, B., Stallinga, S., Katsov, A. Y., Wisniewski, J., Mizuguchi, G., Soule, P., Mueller, F., Darzacq, C. D., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2277 · Cited by 425
Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens
Glaser, A. K., Reder, N. P., Chen, Y., McCarty, E. F., Yin, C., Wei, L., Wang, Y., True, L. D., & Liu, J. T. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0084 · Cited by 419 · cited 1×
“An extended DOF can be achieved via dynamic remote focusing or decoupled illumination and detection (for example, as in a light sheet microscope) 1–6 .”
Background
Metadata
- Authors
- Cao, R., Zhao, J., Li, L., Du, L., Zhang, Y., Luo, Y., Jiang, L., Davis, S., Zhou, Q., de la Zerda, A., & Wang, L. V.
- Venue
- Nature Photonics
- Published
- 2022-12-01
- Volume
- 17
- Issue
- 1
- Pages
- 89-95
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W4310496442
- Cited by
- 159
- References
- 34
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical-resolution photoacoustic microscopy with a needle-shaped beam. https://app.cochat.ai/papers/10.1038/s41566-022-01112-w
- The paper
- Cao, R., Zhao, J., Li, L., Du, L., Zhang, Y., Luo, Y., Jiang, L., Davis, S., Zhou, Q., de la Zerda, A., & Wang, L. V. (2023). Optical-resolution photoacoustic microscopy with a needle-shaped beam. Nature Photonics. https://doi.org/10.1038/s41566-022-01112-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.