Electric field correlation measurements on the electromagnetic vacuum state
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Quantum mechanics ascribes to the ground state of the electromagnetic radiation1 zero-point electric field fluctuations that permeate empty space at all frequencies. No energy can be extracted from the ground state of a system, and therefore these fluctuations cannot be measured directly with an intensity detector. The experimental proof of their existence therefore came from more indirect evidence, such as the Lamb shift2,3,4, the Casimir force between close conductors5,6,7 or spontaneous emission1,8. A direct method of determining the spectral characteristics of vacuum field fluctuations has so far been missing. Here we perform a direct measurement of the field correlation on these fluctuations in the terahertz frequency range by using electro-optic detection9 in a nonlinear crystal placed in a cryogenic environment. We investigate their temporal and spatial coherence, which, at zero time delay and spatial distance, has a peak value of 6.2 × 10−2 volts squared per square metre, corresponding to a fluctuating vacuum field10,11 of 0.25 volts per metre. With this measurement, we determine the spectral components of the ground state of electromagnetic radiation within the bandwidth of our electro-optic detection. Electro-optic detection in a nonlinear crystal is used to measure coherence properties of vacuum fluctuations of the electromagnetic field and deduce the spectrum of the ground state of electromagnetic radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New High-Intensity Source of Polarization-Entangled Photon Pairs
Kwiat, P. G., Mattle, K., Weinfurter, H., Zeilinger, A., Sergienko, A. V., & Shih, Y. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4337 · Cited by 3,102
Loudon, R. (2000) · doi:10.1093/oso/9780198501770.001.0001 · Cited by 1,890
Free-space electro-optic sampling of terahertz beams
Wu, Q., & Zhang, X.-C. (1995) · Applied Physics Letters · doi:10.1063/1.114909 · Cited by 993
Observation of the dynamical Casimir effect in a superconducting circuit
Wilson, C. M., Johansson, G., Pourkabirian, A., Simoen, M., Johansson, J. R., Duty, T., Nori, F., & Delsing, P. (2011) · Nature · doi:10.1038/nature10561 · Cited by 946
Cited by
The 2023 terahertz science and technology roadmap
Leitenstorfer, A., Moskalenko, A. S., Kampfrath, T., Kono, J., Castro-Camus, E., Peng, K., Qureshi, N., Turchinovich, D., Tanaka, K., Markelz, A. G., et al. (2023) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/acbe4c · Cited by 514
“An expanded scheme, implemented first for subcycle measurements of intensity correlations from a THz quantum cascade laser close to the lasing threshold [7], is capable of resolving the temporal and spatial correlations of quantum fields [8], see figure 2.”
BackgroundMethodAn integrated optical modulator operating at cryogenic temperatures
Eltes, F., Villarreal-Garcia, G. E., Caimi, D., Siegwart, H., Gentile, A. A., Hart, A., Stark, P., Marshall, G. D., Thompson, M. G., Barreto, J., et al. (2020) · Nature Materials · doi:10.1038/s41563-020-0725-5 · Cited by 182
Recent advances in petahertz electric field sampling
Herbst, A., Scheffter, K., Bidhendi, M. M., Kieker, M., Srivastava, A., & Fattahi, H. (2022) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/ac8032 · Cited by 40
Metadata
- Authors
- Benea-Chelmus, I.-C., Settembrini, F. F., Scalari, G., & Faist, J.
- Venue
- Nature
- Published
- 2019-04-10
- Volume
- 568
- Issue
- 7751
- Pages
- 202-206
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2890146628
- Cited by
- 141
- References
- 4
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.