Video-based AI for beat-to-beat assessment of cardiac function
Open accessPublished version of a preprint
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Accurate assessment of cardiac function is crucial for the diagnosis of cardiovascular disease 1, screening for cardiotoxicity 2 and decisions regarding the clinical management of patients with a critical illness 3. However, human assessment of cardiac function focuses on a limited sampling of cardiac cycles and has considerable inter-observer variability despite years of training 4,5. Here, to overcome this challenge, we present a video-based deep learning algorithm-EchoNet-Dynamic-that surpasses the performance of human experts in the critical tasks of segmenting the left ventricle, estimating ejection fraction and assessing cardiomyopathy. Trained on echocardiogram videos, our model accurately segments the left ventricle with a Dice similarity coefficient of 0.92, predicts ejection fraction with a mean absolute error of 4.1% and reliably classifies heart failure with reduced ejection fraction (area under the curve of 0.97). In an external dataset from another healthcare system, EchoNet-Dynamic predicts the ejection fraction with a mean absolute error of 6.0% and classifies heart failure with reduced ejection fraction with an area under the curve of 0.96. Prospective evaluation with repeated human measurements confirms that the model has variance that is comparable to or less than that of human experts. By leveraging information across multiple cardiac cycles, our model can rapidly identify subtle changes in ejection fraction, is more reproducible than human evaluation and lays the foundation for precise diagnosis of cardiovascular disease in real time. As a resource to promote further innovation, we also make publicly available a large dataset of 10,030 annotated echocardiogram videos.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Accurate segmentation is essential for many clinical applications, including disease diagnosis, treatment planning, and monitoring of disease progression2,3.”
From Segment anything in medical images (2024) · cites this paper as [3]
In the citing paper
“To account for the fact that most studies utilize privately held medical imaging datasets, 10,000 annotated echocardiogram videos were recently open-sourced 36 .”
From Deep learning-enabled medical computer vision (2021) · cites this paper as [36]
In the citing paper
“Alongside this release, a video-based model, EchoNet-Dynamic 36 , was developed.It can estimate ejection fraction and assess cardiomyopathy, alongside a comprehensive evaluation criterion based on results from an external dataset and human experts.”
From Deep learning-enabled medical computer vision (2021) · cites this paper as [36]
In the citing paper
“Foundation models are uniquely powerful in their ability to integrate multimodal patient data ranging from the EHR [Rajkomar et al. 2018] to medical imaging [Bera et al. 2019; Ouyang et al. 2020] to drug and molecular measurements [Gottlieb et al. 2011; Ruiz et al. 2020] to make an optimal prediction.”
From On the Opportunities and Risks of Foundation Models (2021) · cites this paper as Ouyang et al. 2020
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Learning Spatiotemporal Features with 3D Convolutional Networks
Tran, D., Bourdev, L., Fergus, R., Torresani, L., & Paluri, M. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.510 · Cited by 9,593 · cited 5×
“We tested three model architectures with variable integration of temporal convolutions (R3D, MC3 and R2+1D) and ultimately chose decomposed R2+1D spatiotemporal convolutions as the architecture with the best performance to use for EchoNet-Dynamic 29,30 (Extended Data Fig.”
MethodResultInfluentialLang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361 · cited 10×
“Impairment of Human assessment of the ejection fraction has variance in part due to the common finding of irregularity in the heart rate and the laborious nature of a calculation that requires manual tracing of the size of the ventricle to quantify every beat 4,5 .”
BackgroundMethodInfluentialGulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Rethinking Atrous Convolution for Semantic Image Segmentation
Chen, L.-C., Papandreou, G., Schroff, F., & Adam, H. (2017) · arXiv · doi:10.48550/arxiv.1706.05587 · Cited by 7,517 · cited 1×
“Recent advances in deep learning suggest that it can accurately and reproducibly identify human-identifiable phenotypes as well as characteristics that are not recognized by human experts 24–28 .”
BackgroundThe Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs104 · Cited by 6,879
Cited by
Items 101–200 of 1,000
External validation of a deep learning algorithm for automated echocardiographic strain measurements
Myhre, P. L., Hung, C., Frost, M. J., Jiang, Z., Ouwerkerk, W., TERAMOTO, K., Svedlund, S., Saraste, A., Hage, C., Tan, R., et al. (2023) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad072 · Cited by 51
seUNet-Trans: A Simple Yet Effective UNet-Transformer Model for Medical Image Segmentation
Pham, T.-H., Li, X., & Nguyen, K. (2024) · IEEE Access · doi:10.1109/access.2024.3451304 · Cited by 63
“Medical image segmentation involves identifying and extracting meaningful information from complex medical images, playing a crucial step in many clinical applications including computer-aided diagnosis, image-guided surgery, and treatment planning [1], [2].”
BackgroundRecent advancements and applications of deep learning in heart failure: Α systematic review
Πετμεζάς, Γ., Papageorgiou, V. Ε., Vassilikos, V. P., Pagourelias, E. D., Tsaklidis, G. M., Katsaggelos, A. K., & Maglaveras, N. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108557 · Cited by 58
Artificial Intelligence in Cardiovascular Clinical Trials
Cunningham, J. W., Abraham, W. T., Bhatt, A. S., Dunn, J., Felker, G. M., Jain, S. S., Lindsell, C. J., Mace, M., Martyn, T., Shah, R. U., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.08.069 · Cited by 57
Artificial Intelligence and Echocardiography
Yoon, Y. E., Kim, S., & Chang, H. (2021) · Journal of Cardiovascular Imaging · doi:10.4250/jcvi.2021.0039 · Cited by 59
Confounders mediate AI prediction of demographics in medical imaging
Duffy, G., Clarke, S. L., Christensen, M., He, B., Yuan, N., Cheng, S., & Ouyang, D. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00720-8 · Cited by 47
Self-citationDehazing Ultrasound Using Diffusion Models
Stevens, T. S. W., Meral, F. C., Yu, J., Apostolakis, I., Robert, J.-L., & van Sloun, R. J. G. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3363460 · Cited by 65
“In this experiment, we use a pretrained EchoNet [53] for delineation of the left ventricle and compare masks produced using the unprocessed harmonic imaging data as input with masks produced using diffusion-processed images.”
MethodJCS/JHFS 2025 Guideline on Diagnosis and Treatment of Heart Failure
Kitai, T., Kohsaka, S., Kato, T., Kato, E. T., Sato, K., TERAMOTO, K., Yaku, H., Akiyama, E., Ando, M., Izumi, C., et al. (2025) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2025.02.014 · Cited by 68
The impact of ChatGPT and LLMs on medical imaging stakeholders: Perspectives and use cases
Yang, J., Li, H. B., & Wei, D. (2023) · Meta-Radiology · doi:10.1016/j.metrad.2023.100007 · Cited by 46
“Artificial Intelligence (AI) has been at the forefront of revolutionary changes in numerous sectors, and healthcare is no exception [12, 14, 19, 18].”
BackgroundEchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal Echocardiography
Muhtaseb, R., & Yaqub, M. K. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16440-8_36 · Cited by 65
“We show how our proposed method outperforms all published work to-date on a large scale public dataset [8,10], which does not require: 1) information regarding the position of end-systolic (ES) and end-diastolic (ED) frames, 2) segmentation masks as EchoNet-Dynamic’s beat-to-beat pipeline [8], and…”
InfluentialWang, Y., Li, N., Chen, L., Wu, M., Meng, S., Dai, Z., Zhang, Y., & Clarke, M. (2023) · Journal of Medical Internet Research · doi:10.2196/46089 · Cited by 45
A multimodal deep learning model for cardiac resynchronisation therapy response prediction
Anton, E. P., Sidhu, B. S., Gould, J., Porter, B., Elliott, M. K., Mehta, V. S., Rinaldi, C. A., & King, A. P. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102465 · Cited by 53
“The model was pre-trained using the EchoNet-Dynamic database (Ouyang et al., 2020), which includes 20,060 echocardiography images with annotations (ED and ES frames).”
InfluentialDocherty, K. F., Lam, C. S. P., Rakisheva, A., Coats, A. J. S., Greenhalgh, T., Metra, M., Petrie, M. C., & Rosano, G. M. C. (2023) · European Journal of Heart Failure · doi:10.1002/ejhf.2946 · Cited by 64
Howard, J. P., Stowell, C. C., Cole, G. D., Ananthan, K., Demetrescu, C. D., Pearce, K., Rajani, R., Sehmi, J., Vimalesvaran, K., Kanaganayagam, G. S., et al. (2021) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.120.011951 · Cited by 58
“If the accuracy found in such a manner is imperfect, it is not possible to know whether this is (1) a failure of the AI, (2) a bias in the chosen expert, such as consistently over-estimating Table 3.”
BackgroundThomas, S., Gilbert, A., & Ben-Yosef, G. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16440-8_37 · Cited by 61
Artificial Intelligence in Echocardiography: The Time is Now
Sehly, A. A., Jaltotage, B., He, A., Maiorana, A., Ihdayhid, A. R., Rajwani, A., & Dwivedi, G. (2022) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2308256 · Cited by 45
“[30] trained the CNN model with 10030 apical four chamber echocardiogram videos and was able to predict ejection fraction (EF) with a mean absolute error of 4.”
BackgroundMethodInfluentialZamzmi, G., Hsu, L., Li, W., Sachdev, V., & Antani, S. (2020) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2988295 · Cited by 49
Solving medicine's data bottleneck: Nightingale Open Science
Mullainathan, S., & Obermeyer, Z. (2022) · Nature Medicine · doi:10.1038/s41591-022-01804-4 · Cited by 43
Deep learning-based electrocardiographic screening for chronic kidney disease
Holmström, L. T. A., Christensen, M., Yuan, N., Hughes, J. W., Theurer, J., Jujjavarapu, M., Fatehi, P., Kwan, A. C., Sandhu, R. K., Ebinger, J. E., et al. (2023) · Communications Medicine · doi:10.1038/s43856-023-00278-w · Cited by 50
“Deep learning algorithms (DLA) have recently been applied to medical imaging and clinical data to achieve high precision, and to identify additional information beyond the interpretation of human experts(7, 8).”
Self-citationFortuni, F., Ciliberti, G., Chiara, B. C. D., Conte, E., Franchin, L., Musella, F., Vitale, E., Piroli, F., Cangemi, S., Cornara, S., et al. (2024) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyae136 · Cited by 54
Evaluation of stenoses using AI video models applied to coronary angiography
Langlais, É. L., Corbin, D., Tastet, O., Hayek, A., Doolub, G., Mrad, S., Tardif, J., Tanguay, J., Marquis‐Gravel, G., Tison, G. H., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01134-4 · Cited by 58
“Video-basedmodels,byleveragingtheinherentvariabilityinmultiplecardiac cycles,enhancediagnosticprecisionandeffectivelyaddressthe fl uctuations incardiacfunctionthatoccurfromoneheartbeattothenext 29 .”
BackgroundRoutine Echocardiography and Artificial Intelligence Solutions
Schuuring, M. J., Išgum, I., Cosyns, B., Chamuleau, S. A. J., & Bouma, B. J. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.648877 · Cited by 55
“Last year two large open datasets in the field of 2D echocardiography became publicly available; from Stanford University and University of Lyon (32, 41).”
BackgroundAnalyzing Surgical Technique in Diverse Open Surgical Videos With Multitask Machine Learning
Goodman, E. D., Patel, K. K., Zhang, Y., Locke, W., Kennedy, C. J., Mehrotra, R., Ren, S., Guan, M. Y., Zohar, O., Downing, M., et al. (2023) · JAMA Surgery · doi:10.1001/jamasurg.2023.6262 · Cited by 64
GraphEcho: Graph-Driven Unsupervised Domain Adaptation for Echocardiogram Video Segmentation
Yang, J., Ding, X., Zheng, Z., Xu, X., & Li, X. (2023) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.01091 · Cited by 73
“These parameters can assist physicians in identifying heart diseases, planning treatments, and monitoring progress [12, 32].”
BackgroundMethodResultInfluentialArtificial Intelligence Automation of Echocardiographic Measurements
Sahashi, Y., Ieki, H., Yuan, V., Christensen, M., Vukadinovic, M., Binder-Rodriguez, C., Rhee, J., Zou, J., He, B. D., Cheng, P. P., et al. (2025) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2025.07.053 · Cited by 60
Self-citationDai, W., Li, X., Ding, X., & Cheng, K.-T. T. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3229136 · Cited by 54
“[6] use the R2+1D ResNet [19] to perform regression, achieving an MAE of 4.”
BackgroundMethodInfluentialDevelopment and validation of echocardiography-based machine-learning models to predict mortality
Valsaraj, A., Kalmady, S. V., Sharma, V., Frost, M., Sun, W., Sepehrvand, N., Ong, M. E. H., Equilbec, C., Dyck, J. R. B., Anderson, T. J., et al. (2023) · EBioMedicine · doi:10.1016/j.ebiom.2023.104479 · Cited by 50
“17 Our ResNet models use non-annotated echo PLAX views, whereas the CatBoost models use patient characteristics and manually-acquired measurements.”
MethodThériault-Lauzier, P., Corbin, D., Tastet, O., Langlais, É. L., Taji, B., Kang, G., Chong, A., So, D. Y. F., Tang, A., Gichoya, J. W., et al. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.05.025 · Cited by 65
EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Mokhtari, M., Tsang, T. S. M., Abolmaesumi, P., & Liao, R. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16440-8_35 · Cited by 58
Leveraging physiology and artificial intelligence to deliver advancements in health care
Zhang, A., Wu, Z., Wu, E., Wu, M. A., Snyder, M. P., Zou, J., & Wu, J. C. (2023) · Physiological Reviews · doi:10.1152/physrev.00033.2022 · Cited by 51
Self-citationFeature-Conditioned Cascaded Video Diffusion Models for Precise Echocardiogram Synthesis
Reynaud, H., Qiao, M., Dombrowski, M., Day, T. G., Razavi, R., Gómez, A., Leeson, P., & Kainz, B. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-43999-5_14 · Cited by 60
“All samples were generated with the 1SCM model or were true samples from the EchoNet-Dynamic dataset, resampled to 32fps and 2s.”
MethodInfluentialHirata, Y., Nomura, Y., Saijo, Y., Sata, M., & Kusunose, K. (2024) · Journal of Echocardiography · doi:10.1007/s12574-023-00636-6 · Cited by 41
Deep learning to detect left ventricular structural abnormalities in chest X-rays
Bhave, S., Rodriguez, V., Poterucha, T., Mutasa, S., Aberle, D., Capaccione, K. M., Chen, Y., Dsouza, B., Dumeer, S., Goldstein, J., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehad782 · Cited by 38
“11,12 Recent work has shown that deep learning methods can effectively detect reduced ejection fraction, 13,14 valvular heart disease, 15–17 and LV hypertrophy 18 from cardiac tests such as echocardiograms and electrocardiograms.”
BackgroundSelf-citationGuiding ultrasound image capture with artificial intelligence
Muse, E. D., & Topol, E. J. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31875-4 · Cited by 37
Multimodal Large Language Models as Built Environment Auditing Tools
Jang, K. M., & Kim, J. (2024) · The Professional Geographer · doi:10.1080/00330124.2024.2404894 · Cited by 48
“…have enabled an accurate and reproducible prediction of human assessments with minimal error for multidisciplinary applications, which have been widely adopted by many studies on advanced urban visual analytics (Dubey et al. 2016; Zhang et al. 2018; Ouyang et al. 2020; Biljecki and Ito 2021).”
Multibeat echocardiographic phase detection using deep neural networks
Lane, E. S., Azarmehr, N., Jevsikov, J., Howard, J. P., Shun-Shin, M. J., Cole, G. D., Francis, D. P., & Zolgharni, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104373 · Cited by 45
Wang, S., Li, J., Sun, L., Cai, J., Wang, S., Zeng, L., & Sun, S. (2021) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-021-01667-8 · Cited by 43
Ando, K., Okumura, T., Komachi, M., Horiguchi, H., & Matsumoto, Y. (2022) · PLOS Digital Health · doi:10.1371/journal.pdig.0000158 · Cited by 49
Yang, Y., Cairang, Y., Jiang, T., Zhou, J., Zhang, L., Qi, B., Ma, S., Tang, L., Xu, D., Bu, L., et al. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00091-2 · Cited by 36
Adopting artificial intelligence in cardiovascular medicine: a scoping review
Makimoto, H., & Kohro, T. (2023) · Hypertension Research · doi:10.1038/s41440-023-01469-7 · Cited by 47
Sadeghpour, A., Jiang, Z., Hummel, Y. M., Frost, M., Lam, C. S. P., Shah, S. J., Lund, L. H., Stone, G. W., Swaminathan, M., Weissman, N. J., et al. (2024) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2024.06.011 · Cited by 54
Challenges for augmenting intelligence in cardiac imaging
Sengupta, P. P., Dey, D., Davies, R. H., Duchateau, N., & Yanamala, N. V. K. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00142-0 · Cited by 45
Machine learning: principles and applications for thoracic surgery
Ostberg, N. P., Zafar, M. A., & Elefteriades, J. A. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab095 · Cited by 41
Deep Learning Algorithm to Detect Cardiac Sarcoidosis From Echocardiographic Movies
Katsushika, S., Kodera, S., Nakamoto, M., Ninomiya, K., Kakuda, N., Shinohara, H., Matsuoka, R., Ieki, H., Uehara, M., Higashikuni, Y., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-21-0265 · Cited by 41
Prediction of Coronary Artery Calcium Using Deep Learning of Echocardiograms
Yuan, N., Kwan, A. C., Duffy, G., Theurer, J., Chen, J. H., Nieman, K., Botting, P., Dey, D., Berman, D. S., Cheng, S., et al. (2023) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2022.12.014 · Cited by 36
“16 The PLAX view was chosen because it visualizes anatomical features adjacent to the proximal coronary arteries that can experience early calcification (i.e., the aorta and aortic valve), is readily identified by automated view classifiers, and is easily obtainable by even novice ultrasound…”
Self-citationChen, X., Yang, F., Zhang, P., Lin, X., Wang, W., Pu, H., Chen, X., Chen, Y., Yu, L., Deng, Y., et al. (2023) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.07.001 · Cited by 41
Holste, G., Oikonomou, E. K., Mortazavi, B. J., Wang, Z., & Khera, R. (2024) · Communications Medicine · doi:10.1038/s43856-024-00538-3 · Cited by 61
The future of Cardiothoracic surgery in Artificial intelligence
Mumtaz, H., Saqib, M., Ansar, F., Zargar, D., Hameed, M., Hasan, M., & Muskan, P. (2022) · Annals of Medicine & Surgery · doi:10.1016/j.amsu.2022.104251 · Cited by 35
“…function is associated with limited sampling of cardiac cycles and shows a lot of variability between observers but the EchoNet-Dynamic algorithm reported in a study by Ouyang et al. [14] surpassed human performance in assessing for cardiomyopathy and estimation of ejection fraction [14,15].”
MethodDai, W., Li, X., & Cheng, K.-T. T. (2023) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v37i6.25890 · Cited by 55
Privacy-Preserving Machine Learning for Healthcare: Open Challenges and Future Perspectives
Guerra-Manzanares, A., López, L. J. L., Maniatakos, M., & Shamout, F. E. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-39539-0_3 · Cited by 65
“Despite the use of other input modalities in medical applications, such as video (Ouyang et al., 2020) or text (Srivastava et al., 2019), our review exclusively focuses on medical images and EHR as they are the most prevalent input modalities in diagnostic and prognostic settings (Shehab et al.,…”
BackgroundLong, A., Finer, J., Hartman, H. S., Hartzel, D. N., Jing, L., Kelsey, C. R., Rocha, D., Ruhl, J. A., vanMaanen, D. P., Elnabawi, Y. A., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf248 · Cited by 43
Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Saeed, M., Muhtaseb, R., & Yaqub, M. K. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-12053-4_50 · Cited by 41
“Furthermore, [17] attempted the same task, training on their large publicly available EchoNet-Dynamic dataset [15], containing 20,060 annotated images from 10,030 patients.”
BackgroundLin, X., Yang, F., Chen, Y., Chen, X., Wang, W., Chen, X., Wang, Q., Zhang, L., Guo, H., Liu, B., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.903660 · Cited by 43
“Use of DL models to analyze images from these machines has not been specifically explored in prior studies (9, 10).”
MethodDeep learning for transesophageal echocardiography view classification
Steffner, K. R., Christensen, M., Gill, G., Bowdish, M. E., Rhee, J., Kumaresan, A., He, B. D., Zou, J., & Ouyang, D. (2024) · Scientific Reports · doi:10.1038/s41598-023-50735-8 · Cited by 47
“…convolutions based on our prior work with TTE videos, where we tested multiple model architectures with variable integration of temporal convolutions and found decomposed R2 + 1D spatiotemporal convolutions to have the best balance of computational complexity and model performance 10 .”
MethodSelf-citationRevolutionizing Cardiology: The Role of Artificial Intelligence in Echocardiography
Maturi, B., Dulal, S., Ibrahim, A., Ramakrishna, M., Chinta, V., Nanda, N. C., Sharma, A. K., & Ravipati, H. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14020625 · Cited by 42
“The study concludes that AI-based systems are a reliable and efficient alternative for echocardiographic evaluation of cardiac function, offering significant potential for integration into clinical practice [20,21].”
Future Guidelines for Artificial Intelligence in Echocardiography
Tseng, A. S., López-Jiménez, F. A., & Pellikka, P. A. (2022) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2022.04.005 · Cited by 34
Zhao, C., Chen, W., Qin, J., Yang, P., Xiang, Z., Frangi, A. F., Chen, M., Fan, S., Yu, W., Chen, X., et al. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102648 · Cited by 34
Left Ventricle Segmentation in Echocardiography with Transformer
Liao, M., Lian, Y., Yao, Y., Chen, L., Gao, F., Xu, L., Huang, X., Feng, X., & Guo, S. (2023) · Diagnostics · doi:10.3390/diagnostics13142365 · Cited by 40
“CAMUS provides two views (apical two-chamber and apical four-chamber) from 500 patients [13]; EchoNet Dynamic, which is used in this paper, contains 10,030 annotated echocardiogram videos [4].”
BackgroundMethodResultInfluentialProceedings of the NHLBI Workshop on Artificial Intelligence in Cardiovascular Imaging
Dey, D., Arnaout, R., Antani, S., Badano, A. G., Jacques, L., Li, H., Leiner, T., Margerrison, E., Samala, R. K., Sengupta, P. P., et al. (2023) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2023.05.012 · Cited by 44
Self-supervised learning for label-free segmentation in cardiac ultrasound
Ferreira, D. L., Lau, C., Salaymang, Z., & Arnaout, R. (2025) · Nature Communications · doi:10.1038/s41467-025-59451-5 · Cited by 44
Kwan, J. M., Oikonomou, E. K., Henry, M. L., & Sinusas, A. J. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.829553 · Cited by 36
“For instance, in the field of transthoracic echocardiography, deep learning video-based models now enables fast and automated calculation of LVEF, with variance that is comparable to that or even lower of a human observer (160, 161).”
BackgroundPneumoLLM: Harnessing the power of large language model for pneumoconiosis diagnosis
Song, M., Wang, J., Yu, Z., Wang, J., Yang, L., Lu, Y., Li, B., Wang, X., Wang, X., Huang, Q., et al. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103248 · Cited by 31
Digital tools in heart failure: addressing unmet needs
Myhre, P. L., Tromp, J., Ouwerkerk, W., Ting, D. S. W., Docherty, K. F., Gibson, C. M., & Lam, C. S. P. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00158-4 · Cited by 31
Adaptive Contrast for Image Regression in Computer-Aided Disease Assessment
Dai, W., Li, X., Chiu, K. W.-H., Kuo, M., & Cheng, K.-T. T. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3137854 · Cited by 36
Moal, O., Roger, É., Lamouroux, A., Younes, C., Bonnet, G., Moal, B., & Lafitte, S. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105637 · Cited by 32
Kim, Y., Park, J. Y., Hwang, E. J., Lee, S. M., & Park, C. M. (2021) · Journal of Thoracic Disease · doi:10.21037/jtd-21-1342 · Cited by 31
“Convolutional neural network (CNN)based deep learning (DL) models have shown performance equal to or even surpassing that of experts in various tasks, including the detection of retinal pathologies in fundus photographs (1-4), interpretation of echocardiography (5-7) and screening mammography (8), and the diagnosis of…”
BackgroundMyocardial strain analysis of echocardiography based on deep learning
Deng, Y., Cai, P., Zhang, L., Cao, X., Chen, Y., Jiang, S., Zhuang, Z., & Wang, B. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.1067760 · Cited by 41
“relied on manually labeled still images at end-systole (ES) and end-diastole (ED) instead of using the actual echocardiogram videos (22).”
MethodAutomated Deep Learning Phenotyping of Tricuspid Regurgitation in Echocardiography
Vrudhula, A., Vukadinovic, M., Haeffele, C. L., Kwan, A. C., Berman, D. S., Liang, D. H., Siegel, R., Cheng, S. C., & Ouyang, D. (2025) · JAMA Cardiology · doi:10.1001/jamacardio.2025.0498 · Cited by 42
Self-citationPRIME 2.0: Proposed Requirements for Cardiovascular Imaging-Related Multimodal-AI Evaluation
Kagiyama, N., Tokodi, M., Hathaway, Q. A., Arnaout, R., Davies, R. H., Dey, D., Duchateau, N., Fraser, A. G., Goto, S., Jamthikar, A. D., et al. (2025) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2025.08.004 · Cited by 45
Self-citationHierarchical Vision Transformers for Cardiac Ejection Fraction Estimation
Fazry, L., Haryono, A., Nissa, N. K., Sunarno, Hirzi, N. M., Rachmadi, M. F., & Jatmiko, W. (2022) · International Workshop on Big Data and Information Security (IWBIS) · doi:10.1109/iwbis56557.2022.9924664 · Cited by 39
“EF value which is less than 50% can be considered as cardiomyopathies [5].”
BackgroundZhang, Z., Yu, C., Zhang, H., & Gao, Z. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3362964 · Cited by 30
“We use the following datasets in the evaluations : (1) Echonet Dynamic [14]”
BackgroundMethodInfluentialMathis, M. R., Steffner, K. R., Subramanian, H., Gill, G., Girardi, N. I., Bansal, S., Bartels, K., Khanna, A. K., & Huang, J. (2024) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2024.02.004 · Cited by 33
Revolutionizing Medical Practice: The Impact of Artificial Intelligence (AI) on Healthcare
(2024) · Open Access Journal of Applied Science and Technology · doi:10.33140/oajast.02.01.07 · Cited by 40
Yuan, N., Jain, I., Rattehalli, N., He, B. D., Pollick, C., Liang, D. H., Heidenreich, P. A., Zou, J., Cheng, S. C., & Ouyang, D. (2021) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2021.06.018 · Cited by 29
Self-citationLiquid Biopsy Instrument for Ultra-Fast and Label-Free Detection of Circulating Tumor Cells
Shu, Z., Zhu, Z., Ni, C., Zhou, Z., Yao, C., Tang, D., Guo, K., Yang, S., Liu, K., Ni, Z., et al. (2024) · Research · doi:10.34133/research.0431 · Cited by 27
“Compared to 2D CNN, which is commonly used for processing image data, 1D CNN is more suitable for processing sequence data containing temporal information, such as electrical signals [46].”
MethodArtificial Intelligence Applications in Cardio-Oncology: A Comprehensive Review
Guha, A., Shah, V., Nahle, T., Singh, S., Kunhiraman, H. H., Shehnaz, F., Nain, P., Makram, O. M., Mahmoudi, M., Al-Kindi, S. G., et al. (2025) · Current Cardiology Reports · doi:10.1007/s11886-025-02215-w · Cited by 39
“It was shown that the FDA-approved packages EchoAI1 and EchoAI2 could measure LVEF with variability that is non-inferior to human specialists [57, 58], with the study conducted by Dowsing et al. being performed on patients with cancer [59 ].”
Applications, challenges and future directions of artificial intelligence in cardio‐oncology
Ravera, F., Gilardi, N., Ballestrero, A., & Zoppoli, G. M. (2025) · European Journal of Clinical Investigation · doi:10.1111/eci.14370 · Cited by 37
“57 Notably, Hanif et al. addressed the issues of inter-reader and inter-vendor variability in GLS assessment in the cardio-oncology setting by evaluating TTE performed in patients treated with anthracycline-based chemotherapy.”
Transformer-Based Innovations in Medical Image Segmentation: A Mini Review
Shah, O. I., Rizvi, D. R., & Mir, A. N. (2025) · SN Computer Science · doi:10.1007/s42979-025-03929-y · Cited by 37
“Their method utilizes a Convolutional Neural Network (CNN) based one-stage detector called [73] 2023 EchoNet-Dynamic [74] Ultrasound TransFusion [75] 2022 Cardiac MRI [76] MRI TF-Unet [77] 2022 Synapse [35], ACDC [36] CT, MRI TransBridge [78] 2021 EchoNet-Dynamic [74] Ultrasound aspect comes into…”
Morita, S. X., Kusunose, K., Haga, A., Sata, M., Hasegawa, K., Raita, Y., Reilly, M. P., Fifer, M. A., Maurer, M. S., & Shimada, Y. J. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.669860 · Cited by 28
“By contrast, deep learning has a potential to overcome such variability in human assessment of echocardiographic measurements (32).”
BackgroundChen, H., Ouyang, D., Baykaner, T., Jamal, F. A., Cheng, P. P., & Rhee, J. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.941148 · Cited by 33
“Technical differences in image acquisition, variability between operators performing cardiac ultrasound, and subjective differences in appreciation of the blood-tissue interface between readers collectively contribute to variability in measurements of LVEF (8).”
Self-citationVrudhula, A., Stern, L. K., Cheng, P. P., Ricchiuto, P., Daluwatte, C., Witteles, R. M., Patel, J. K., & Ouyang, D. (2024) · JACC Advances · doi:10.1016/j.jacadv.2024.100998 · Cited by 31
Self-citationLi, X., Zhang, H., Yue, J., Yin, L., Li, W., Ding, G., Peng, B., & Xie, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-71530-z · Cited by 44
M 3 -UDA: A New Benchmark for Unsupervised Domain Adaptive Fetal Cardiac Structure Detection
Pu, B., Wang, L., Yang, J., He, G., Dong, X., Li, S., Tan, Y., Chen, M., Jin, Z., Li, K., et al. (2024) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr52733.2024.01104 · Cited by 34
“The comparison of FCS, CardiacUDA [47], CA-MUS [24], and EchoNet [34]. while, accurate annotation information provided by obste-trician experts is costly or even unavailable in practice, especially in low-resource settings with a severe shortage of well-trained obstetricians.”
MethodArtificial Intelligence in Diagnosis of Heart Failure
Xie, Y., Zhang, L., Sun, W., Zhu, Y. C., Zhang, Z., Chen, L., Xie, M., & Zhang, L. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.124.039511 · Cited by 35
The Use of Machine Learning for the Care of Hypertension and Heart Failure
Cai, A., Zhu, Y., Clarkson, S. A., & Feng, Y. (2021) · JACC Asia · doi:10.1016/j.jacasi.2021.07.005 · Cited by 32
Artificial Intelligence-Enhanced Echocardiography for Systolic Function Assessment
Zhang, Z., Zhu, Y., Liu, M., Zhang, Z., Zhao, Y., Yang, X., Xie, M., & Zhang, L. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11102893 · Cited by 26
“Human assessment of cardiac function depends on the sonographer’s experience, and inter-observer and intra-observer variability exist [19].”
BackgroundMethodInfluentialWeakly supervised inference of personalized heart meshes based on echocardiography videos
Laumer, F., Amrani, M., Manduchi, L., Beuret, A., Rubi, L., Dubatovka, A., Matter, C. M., & Buhmann, J. M. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102653 · Cited by 34
Tiago, C., Snare, S. R., Šprem, J., & McLeod, K. (2023) · IEEE Access · doi:10.1109/access.2023.3246762 · Cited by 33
“First, the EchoNet-Dynamic dataset presented by Ouyang et al. [28], was used.”
MethodThe year in cardiovascular medicine 2020: digital health and innovation
Antoniades, C. A., Asselbergs, F. W., & Vardas, P. E. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa1065 · Cited by 29
“From an ultrasound point of view, 2020 has been a year for the consolidation of earlier technical developments in how to train neural networks to handle raw images and video loops from echocardiograms to segment and extract useful metrics such as ejection fraction and myocardial strain.32 The study by Ouyang et al.33…”
BackgroundZhang, P., Yin, Z., & Jin, Y. (2021) · International Journal for Numerical and Analytical Methods in Geomechanics · doi:10.1002/nag.3296 · Cited by 28
“22,23 In 3D-CNN, a series of 2D slices images of the studied object can be extracted by X-ray computed tomography or photography, etc., 24–26 and then they are aligned along the depth dimension as the input of 3D-CNN.”
BackgroundMethodHerz, C., Pace, D. F., Nam, H. H., Lassó, A., Dinh, P. V., Flynn, M., Cianciulli, A. R., Golland, P., & Jolley, M. A. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.735587 · Cited by 33
Degerli, A., Yamaç, M., Ahishali, M., Serkan Kiranyaz, B., & Gabbouj, M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-32-385787-1.00025-7 · Cited by 26
D’ARTAGNAN: Counterfactual Video Generation
Reynaud, H., Vlontzos, A., Dombrowski, M., Lee, C. M., Beqiri, A., Leeson, P., & Kainz, B. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16452-1_57 · Cited by 44
A generalized deep learning model for heart failure diagnosis using dynamic and static ultrasound
Liu, Z., Huang, Y., Li, H., Li, W., Zhang, F., Ouyang, W., Wang, S., Luo, Z., Wang, J., Chen, Y., et al. (2023) · Journal of Translational Internal Medicine · doi:10.2478/jtim-2023-0088 · Cited by 30
“[8] in Nature , the Cardiac Acquisitions for Multi-structure Ultrasound Segmentation (CAMUS) dataset published by Sarah Leclerc et al .”
MethodPolypMixNet: Enhancing semi-supervised polyp segmentation with polyp-aware augmentation
Jia, X., Shen, Y., Jian-hong, Y., Song, R., Zhang, W., Meng, M. Q. ‐., Liao, J. C., & Xing, L. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108006 · Cited by 32
Revolutionising Acute Cardiac Care With Artificial Intelligence: Opportunities and Challenges
Doolub, G., Khurshid, S. S., Thériault-Lauzier, P., Lapalme, A. N., Tastet, O., So, D. Y. F., Langlais, É. L., Corbin, D., & Avram, R. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.06.011 · Cited by 41
“Ouyang et al. 43 used 3-dimensional convolutions to predict heart failure with reduced ejection fraction, highlighting AI’s capacity for prognostication.”
The Role of Artificial Intelligence and Machine Learning in Cardiovascular Imaging and Diagnosis
Reza-Soltani, S., Alam, L. F., Debellotte, O., Monga, T. S., Coyalkar, V. R., Tarnate, V. C. A., Ozoalor, C. U., Allam, S. R., Afzal, M., Shah, G. K., et al. (2024) · Cureus · doi:10.7759/cureus.68472 · Cited by 43
“CNNs have demonstrated high accuracy in left ventricular segmentation and quantification of cardiac function parameters such as ejection fraction and strain analysis [14].”
MethodAI-echocardiography: Current status and future direction
Sahashi, Y., Ouyang, D., Okura, H., & Kagiyama, N. (2025) · Journal of Cardiology · doi:10.1016/j.jjcc.2025.02.005 · Cited by 35
Self-citationA Deep Bayesian Video Analysis Framework: Towards a More Robust Estimation of Ejection Fraction
Esfeh, M. M. K., Luong, C. L., Behnami, D., Tsang, T. S. M., & Abolmaesumi, P. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59713-9_56 · Cited by 32
Echo-SyncNet: Self-Supervised Cardiac View Synchronization in Echocardiography
Dezaki, F. T., Luong, C. L., Ginsberg, T., Rohling, R. N., Gin, K., Abolmaesumi, P., & Tsang, T. S. M. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3071951 · Cited by 29
Metadata
- Authors
- Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y.
- Affiliations
- Stanford Medicine (US)
- Stanford University (US)
- Cedars-Sinai Medical Center (US)
- Corresponding author
- Ouyang, David
- Zou, James Y.
- ORCID
- Venue
- Nature
- Published
- 2020-03-25
- Volume
- 580
- Issue
- 7802
- Pages
- 252-256
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC8979576
- OpenAlex
- W3013692475
- Cited by
- 1,153
- References
- 41
- Citations by year
- 2026: 263 · 2025: 276 · 2024: 212 · 2023: 172 · 2022: 122 · 2021: 85 · 2020: 22
- FWCI
- 62.03
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature (publishedVersion)
- medRxiv (acceptedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- National Science Foundation (1763191)
- American College of Cardiology Foundation
- National Institutes of Health (1r21md012867-01, R21 MD012867-01)
- National Institute on Aging (P30AG059307)
- National Heart, Lung, and Blood Institute (F32 HL149298)
- National Institute on Minority Health and Health Disparities (R21 MD012867)
- Stanford Cardiovascular Institute, School of Medicine, Stanford University
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- EchoNet-Dynamic, echocardiography, left ventricle segmentation, ejection fraction estimation, heart failure with reduced ejection fraction, cardiomyopathy classification, interobserver variability, cardiovascular disease diagnosis
- MeSH terms
- Deep Learning, Atrial Fibrillation, Echocardiography, Heart, Heart Diseases, Heart Failure, Hospitals, Humans, Models, Cardiovascular, Prospective Studies, Video Recording, Reproducibility of Results, Ventricular Function, Left, Datasets as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.