CoChat

Universal control of a six-qubit quantum processor in silicon

Open access

The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.

Abstract

Future quantum computers capable of solving relevant problems will require a large number of qubits that can be operated reliably 1 . However, the requirements of having a large qubit count and operating with high fidelity are typically conflicting. Spins in semiconductor quantum dots show long-term promise 2,3 but demonstrations so far use between one and four qubits and typically optimize the fidelity of either single- or two-qubit operations, or initialization and readout 4–11 . Here, we increase the number of qubits and simultaneously achieve respectable fidelities for universal operation, state preparation and measurement. We design, fabricate and operate a six-qubit processor with a focus on careful Hamiltonian engineering, on a high level of abstraction to program the quantum circuits, and on efficient background calibration, all of which are essential to achieve high fidelities on this extended system. State preparation combines initialization by measurement and real-time feedback with quantum-non-demolition measurements. These advances will enable testing of increasingly meaningful quantum protocols and constitute a major stepping stone towards large-scale quantum computers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-022-05117-x

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Device initialization, measurement and calibration. a, A false-coloured scanning electron microscope image of a device similar to the one used in the experiments. Each colour represents a different metallization layer. Plunger (P, blue) and barrier (B, green) gates are used to define quantum dots in the channel between the screening gates (red) and sensing dots (SD1 and SD2) on the side. Two cobalt micromagnets (yellow) are placed on top of the gate stack. b,c, Buildings blocks used for readout (read) and initialization (init) in this experiment, showing the circuit used to perform a single QND measurement of qubit Q3 (b) and the circuit used for spin measurement and initialization using a parity measurement (c). The double line in the diagram indicates that X180 rotation is conditional on the measurement outcome. d, An example of a CROT used to initialize the qubits. The sequence shown is applied repeatedly with short time intervals, with the final state of one cycle being the initial state of the next. (1) shows the even parity probability of the first measurement; (2) shows the even parity probability after the bit flip conditional on the first measurement outcome. e, Schematic showing the total scheme used for the initialization and readout of all six qubits, with U, the unitary matrix of the manipulation stage (see Extended Data Fig. 2 for an expanded view). f, Calibration graph used in the experiments. The numbers on the right show the number of parameters that are calibrated in each step.
Fig. 1 Device initialization, measurement and calibration. a, A false-coloured scanning electron microscope image of a device similar to the one used in the experiments. Each colour represents a different metallization layer. Plunger (P, blue) and barrier (B, green) gates are used to define quantum dots in the channel between the screening gates (red) and sensing dots (SD1 and SD2) on the side. Two cobalt micromagnets (yellow) are placed on top of the gate stack. b,c, Buildings blocks used for readout (read) and initialization (init) in this experiment, showing the circuit used to perform a single QND measurement of qubit Q3 (b) and the circuit used for spin measurement and initialization using a parity measurement (c). The double line in the diagram indicates that X180 rotation is conditional on the measurement outcome. d, An example of a CROT used to initialize the qubits. The sequence shown is applied repeatedly with short time intervals, with the final state of one cycle being the initial state of the next. (1) shows the even parity probability of the first measurement; (2) shows the even parity probability after the bit flip conditional on the first measurement outcome. e, Schematic showing the total scheme used for the initialization and readout of all six qubits, with U, the unitary matrix of the manipulation stage (see Extended Data Fig. 2 for an expanded view). f, Calibration graph used in the experiments. The numbers on the right show the number of parameters that are calibrated in each step.CC BY · PubMed Central
Fig. 2 Single-qubit gate characterization. a, Rabi oscillations for every qubit, taken sequentially. The spin fraction refers to the spin-up fraction for qubits Q2–Q5 and to the spin-down fraction for qubits Q1 and Q6. The drive amplitudes were adjusted in order to obtain uniform Rabi frequencies of 5 MHz. b, Qubit frequency for each of the six qubits. c, Rabi frequency of each qubit as a function of the applied microwave power. d, Randomized benchmarking results for each qubit, using a 5 MHz Rabi frequency. The reported fidelity is the average single-qubit gate fidelity, and the uncertainties (2σ) are calculated using the covariance matrix of the fit. e, Table showing the dephasing time T2*, Hahn echo decay time (T2h) and visibilities (vis.) for each qubit.
Fig. 2 Single-qubit gate characterization. a, Rabi oscillations for every qubit, taken sequentially. The spin fraction refers to the spin-up fraction for qubits Q2–Q5 and to the spin-down fraction for qubits Q1 and Q6. The drive amplitudes were adjusted in order to obtain uniform Rabi frequencies of 5 MHz. b, Qubit frequency for each of the six qubits. c, Rabi frequency of each qubit as a function of the applied microwave power. d, Randomized benchmarking results for each qubit, using a 5 MHz Rabi frequency. The reported fidelity is the average single-qubit gate fidelity, and the uncertainties (2σ) are calculated using the covariance matrix of the fit. e, Table showing the dephasing time T2*, Hahn echo decay time (T2h) and visibilities (vis.) for each qubit.CC BY · PubMed Central
Fig. 3 Two-qubit gate characterization. a, Quantum circuit used to measure CPhase oscillations between a pair of qubits. b–f, Measured spin probabilities as a function of the total evolution time 2t for neighbouring qubit pairs Q1–Q2 (b), Q2–Q3 (c), Q3–Q4 (d), Q4–Q5 (e) and Q5–Q6 (f) for different virtual barrier gate voltages (with 0 and 1 corresponding to the exchange switched off and at its maximum value). g, Maximum exchange coupling measured for each qubit pair, and the corresponding residual exchange coupling for the other pairs, achievable within the AWG pulsing range without retuning of the static gate voltages. Bottom row: Jij with all exchange couplings switched off (see Supplementary Information for error bars). h, Exchange coupling versus virtual barrier gate voltage for all qubit pairs. i, Schematic showing the energy levels in the absence (left) and presence (middle, right) of the effective Ising ZZ interaction under exchange (see text). Owing to the ZZ coupling term, the antiparallel spin states are lowered in energy, and pick up an additional phase as a function of time, resulting in a CPhase evolution. The shifted energy levels also enable conditional microwave-driven rotations (CROT), which we use during initialization and readout. j, Pulse shape of the exchange amplitude throughout a gate voltage pulse used for the CZ gate, and the corresponding pulse shape converted to gate voltage.
Fig. 3 Two-qubit gate characterization. a, Quantum circuit used to measure CPhase oscillations between a pair of qubits. b–f, Measured spin probabilities as a function of the total evolution time 2t for neighbouring qubit pairs Q1–Q2 (b), Q2–Q3 (c), Q3–Q4 (d), Q4–Q5 (e) and Q5–Q6 (f) for different virtual barrier gate voltages (with 0 and 1 corresponding to the exchange switched off and at its maximum value). g, Maximum exchange coupling measured for each qubit pair, and the corresponding residual exchange coupling for the other pairs, achievable within the AWG pulsing range without retuning of the static gate voltages. Bottom row: Jij with all exchange couplings switched off (see Supplementary Information for error bars). h, Exchange coupling versus virtual barrier gate voltage for all qubit pairs. i, Schematic showing the energy levels in the absence (left) and presence (middle, right) of the effective Ising ZZ interaction under exchange (see text). Owing to the ZZ coupling term, the antiparallel spin states are lowered in energy, and pick up an additional phase as a function of time, resulting in a CPhase evolution. The shifted energy levels also enable conditional microwave-driven rotations (CROT), which we use during initialization and readout. j, Pulse shape of the exchange amplitude throughout a gate voltage pulse used for the CZ gate, and the corresponding pulse shape converted to gate voltage.CC BY · PubMed Central
Fig. 4 Bell state tomography. a–e, Measured two-qubit density matrices for qubits Q1–Q2 (a), Q2–Q3 (b), Q3–Q4 (c), Q4–Q5 (d) and Q5–Q6 (e), after removal of SPAM errors (see Supplementary Information for the uncorrected density matrices). The target Bell states are indicated and outlined with the wireframes. f, Colour wheel with phase information for the density matrices presented in a–e. g, Quantum circuits used for converting parity readout (ZZ) into effective single-qubit readout (IZ and ZI). h, State fidelities of the measured density matrices with respect to the target Bell states and the concurrences for the measured density matrices. Error bars (2σ) are derived from Monte Carlo bootstrap resampling9,44,59. State fidelities without readout error removal: qubits Q1–Q2, 88.2%; Q2–Q3, 83.8%; Q3–Q4, 78.0%; Q4–Q5, 91.3%; Q5–Q6, 91.3%.
Fig. 4 Bell state tomography. a–e, Measured two-qubit density matrices for qubits Q1–Q2 (a), Q2–Q3 (b), Q3–Q4 (c), Q4–Q5 (d) and Q5–Q6 (e), after removal of SPAM errors (see Supplementary Information for the uncorrected density matrices). The target Bell states are indicated and outlined with the wireframes. f, Colour wheel with phase information for the density matrices presented in a–e. g, Quantum circuits used for converting parity readout (ZZ) into effective single-qubit readout (IZ and ZI). h, State fidelities of the measured density matrices with respect to the target Bell states and the concurrences for the measured density matrices. Error bars (2σ) are derived from Monte Carlo bootstrap resampling9,44,59. State fidelities without readout error removal: qubits Q1–Q2, 88.2%; Q2–Q3, 83.8%; Q3–Q4, 78.0%; Q4–Q5, 91.3%; Q5–Q6, 91.3%.CC BY · PubMed Central
Fig. 5 Three-qubit GHZ state tomography. a, Circuit diagram used to prepare the GHZ states. The Umap operation is the unitary that is executed in case we measure the IZ or ZI projections on qubits Q1–Q2 and Q5–Q6, similar to the Bell state experiments. b–e, Density matrices of the prepared GHZ states using qubits Q1–Q2–Q3 (b), Q2–Q3–Q4 (c), Q3–Q4–Q5 (d) and Q4–Q5–Q6 (e), obtained using quantum state tomography, after removal of SPAM errors (see Supplementary Information for the uncorrected density matrices). The black wireframes correspond to the ideal GHZ state. f, Colour wheel with phase information for the density matrices presented in d and e. g, Table showing the state fidelities and entanglement witness values for the different qubit sets. We choose ϕ in ∣ψGHZ⟩=(∣000⟩+e^iφ∣111⟩)√2, with respect to the highest state fidelity. State fidelities without SPAM removal: qubits Q1–Q2–Q3, 64.3%; Q2–Q3–Q4, 52.8%; Q3–Q4–Q5, 52.7%; Q4–Q5–Q6, 67.2%.
Fig. 5 Three-qubit GHZ state tomography. a, Circuit diagram used to prepare the GHZ states. The Umap operation is the unitary that is executed in case we measure the IZ or ZI projections on qubits Q1–Q2 and Q5–Q6, similar to the Bell state experiments. b–e, Density matrices of the prepared GHZ states using qubits Q1–Q2–Q3 (b), Q2–Q3–Q4 (c), Q3–Q4–Q5 (d) and Q4–Q5–Q6 (e), obtained using quantum state tomography, after removal of SPAM errors (see Supplementary Information for the uncorrected density matrices). The black wireframes correspond to the ideal GHZ state. f, Colour wheel with phase information for the density matrices presented in d and e. g, Table showing the state fidelities and entanglement witness values for the different qubit sets. We choose ϕ in ∣ψGHZ⟩=(∣000⟩+e^iφ∣111⟩)√2, with respect to the highest state fidelity. State fidelities without SPAM removal: qubits Q1–Q2–Q3, 64.3%; Q2–Q3–Q4, 52.8%; Q3–Q4–Q5, 52.7%; Q4–Q5–Q6, 67.2%.CC BY · PubMed Central
Extended Data Fig. 1 Pauli Spin Blockade readout. a, Energy diagram for a double quantum dot as a function of the detuning between the (1,1)/(2,0) charge electron occupation. The Zeeman energy (Ez) for qubit Q1, Q2 is set to 74, 75 μ eV (18/18.2 GHz) and the valley energy (ϵv) of dot 1 is set to 65 μ eV. We set ϵv for the second dot to a much larger value to shift part of the energy spectrum out of view and simplify the visual analysis. The charge and valley occupations are indicated in the top right of this panel. b, Energy diagram in the (3,1)/(4,0) charge occupation. This panel uses identical parameter values as panel a, except for the Zeeman energy for qubit Q1 and Q2, 25 and 26 μ eV (6 and 6.2 GHz). The excited state energy of dot 1 in the (4,0) charge occupation is given by the orbital energy instead of the valley splitting. c Experimental charge stability diagram taken at the (3,1)/(4,0) anticrossing for dots 1 and 2. The point indicated with ’1’ indicates the qubit operation point and the point indicated as ’2’ indicates the readout point. The inset zooms in on the anticrossing, allowing one to observe the spin selective tunneling for the different input states (the readout zone). d In our experiment we initialize via measurement and post-selection. In the plot we can see the effects of two subsequent readouts. First readout ’m1 (raw)’ shows the initial singlet fraction (electron spins are not intentionally randomized and by nature of the executed measurement sequence, a singlet state is preserved for next single shot). Second measurement ’m2’ shows the outcome from post-selection on the result of ’m1’ (realized as per-measurement-point post-processing in software). Within the readout zone (shaded area) the initialized singlet fraction is greatly amplified. e–f Probability density function of the PSB readout signal between qubit pairs Q12 and Q56 (10 μ s integration time), recorded in the course of the Rabi oscillations of qubit Q1, Q5 in figure 2. The Gaussians are fitted to the two distributions and charge readout fidelities, estimated from their overlap, exceeding 99.9%. No T1 decay was observed at the readout point (T1 > > 100 μs). g, Gate voltage pulses applied to perform PSB readout on qubit pair Q12. The different background colors indicate the ramp towards the readout point (green), measurement at the readout point (yellow) and the adiabatic ramp back to the operating point (red).
Extended Data Fig. 1 Pauli Spin Blockade readout. a, Energy diagram for a double quantum dot as a function of the detuning between the (1,1)/(2,0) charge electron occupation. The Zeeman energy (Ez) for qubit Q1, Q2 is set to 74, 75 μ eV (18/18.2 GHz) and the valley energy (ϵv) of dot 1 is set to 65 μ eV. We set ϵv for the second dot to a much larger value to shift part of the energy spectrum out of view and simplify the visual analysis. The charge and valley occupations are indicated in the top right of this panel. b, Energy diagram in the (3,1)/(4,0) charge occupation. This panel uses identical parameter values as panel a, except for the Zeeman energy for qubit Q1 and Q2, 25 and 26 μ eV (6 and 6.2 GHz). The excited state energy of dot 1 in the (4,0) charge occupation is given by the orbital energy instead of the valley splitting. c Experimental charge stability diagram taken at the (3,1)/(4,0) anticrossing for dots 1 and 2. The point indicated with ’1’ indicates the qubit operation point and the point indicated as ’2’ indicates the readout point. The inset zooms in on the anticrossing, allowing one to observe the spin selective tunneling for the different input states (the readout zone). d In our experiment we initialize via measurement and post-selection. In the plot we can see the effects of two subsequent readouts. First readout ’m1 (raw)’ shows the initial singlet fraction (electron spins are not intentionally randomized and by nature of the executed measurement sequence, a singlet state is preserved for next single shot). Second measurement ’m2’ shows the outcome from post-selection on the result of ’m1’ (realized as per-measurement-point post-processing in software). Within the readout zone (shaded area) the initialized singlet fraction is greatly amplified. e–f Probability density function of the PSB readout signal between qubit pairs Q12 and Q56 (10 μ s integration time), recorded in the course of the Rabi oscillations of qubit Q1, Q5 in figure 2. The Gaussians are fitted to the two distributions and charge readout fidelities, estimated from their overlap, exceeding 99.9%. No T1 decay was observed at the readout point (T1 > > 100 μs). g, Gate voltage pulses applied to perform PSB readout on qubit pair Q12. The different background colors indicate the ramp towards the readout point (green), measurement at the readout point (yellow) and the adiabatic ramp back to the operating point (red).CC BY · PubMed Central
Extended Data Fig. 2 Full quantum circuits. a, This circuit was used to produce the data presented in Fig. 5c. The different background colors indicate the different parts of the sequence (yellow – initialization, green – manipulation (including the tomography pulses), blue – readout). The sequence could be made much shorter if we would parallelize the readout operations. We did not implement this, since this is not the limiting factor (tread < < T1).
Extended Data Fig. 2 Full quantum circuits. a, This circuit was used to produce the data presented in Fig. 5c. The different background colors indicate the different parts of the sequence (yellow – initialization, green – manipulation (including the tomography pulses), blue – readout). The sequence could be made much shorter if we would parallelize the readout operations. We did not implement this, since this is not the limiting factor (tread < < T1).CC BY · PubMed Central
Extended Data Fig. 3 Loss in visibility when initializing all qubits. a, Gate sequence used to demonstrate the effect of running different qubit initialization routines. Microwave bursts with variable duration are performed sequentially on qubits Q2, Q3, Q4 and Q5, as shown in the schematic. In all cases, readout is performed on all the qubits, but we vary which qubits are initialized for a particular experiment. b–d, Results of the sequence displayed in panel a, when qubit Q1-Q3 (b), Q4-Q6 (c) or Q1-Q6 (d) are initialized. The shaded numbers in the panels indicate the visibility of the measured qubit. With all qubits initialized we observe a visibility loss on qubit Q4 and to a lesser extent qubit Q3. A visibility loss in principle can originate from a reduced readout or initialization fidelity. We keep the readout sequence identical for a, b, and c. Additionally, we include a 500 μs waiting time prior to readout, to minimize any effects of MW pulsing during initialization or manipulation stage on the readout performance (see Methods). Although, we cannot be certain that the readout fidelity is unaffected by the initialization of all qubits, we speculate that the majority of the observed visibility loss is due to a reduced initialization fidelity, possibly due to the sensitivity of the CROTs to qubit frequency shifts. This interpretation is consistent with the fact that mostly qubit Q4 suffers a lower visibility, as qubit Q4 is initialized before qubits Q1, Q2 and Q3. If instead we reverse the initialization order, qubit Q3 displays lowered visibility (data not shown).
Extended Data Fig. 3 Loss in visibility when initializing all qubits. a, Gate sequence used to demonstrate the effect of running different qubit initialization routines. Microwave bursts with variable duration are performed sequentially on qubits Q2, Q3, Q4 and Q5, as shown in the schematic. In all cases, readout is performed on all the qubits, but we vary which qubits are initialized for a particular experiment. b–d, Results of the sequence displayed in panel a, when qubit Q1-Q3 (b), Q4-Q6 (c) or Q1-Q6 (d) are initialized. The shaded numbers in the panels indicate the visibility of the measured qubit. With all qubits initialized we observe a visibility loss on qubit Q4 and to a lesser extent qubit Q3. A visibility loss in principle can originate from a reduced readout or initialization fidelity. We keep the readout sequence identical for a, b, and c. Additionally, we include a 500 μs waiting time prior to readout, to minimize any effects of MW pulsing during initialization or manipulation stage on the readout performance (see Methods). Although, we cannot be certain that the readout fidelity is unaffected by the initialization of all qubits, we speculate that the majority of the observed visibility loss is due to a reduced initialization fidelity, possibly due to the sensitivity of the CROTs to qubit frequency shifts. This interpretation is consistent with the fact that mostly qubit Q4 suffers a lower visibility, as qubit Q4 is initialized before qubits Q1, Q2 and Q3. If instead we reverse the initialization order, qubit Q3 displays lowered visibility (data not shown).CC BY · PubMed Central
Extended Data Fig. 4 Calibrations. a–m Each panel shows a typical experimental dataset obtained in one of the calibration routines for the relevant experimental parameters. Every panel indicates in the header the calibration name and the corresponding number of calibration parameters. Below the header, the values extracted from the data is indicated. See the methods section for a detailed description. n, Table showing the formulas used to fit the data for the indicated figure panels.
Extended Data Fig. 4 Calibrations. a–m Each panel shows a typical experimental dataset obtained in one of the calibration routines for the relevant experimental parameters. Every panel indicates in the header the calibration name and the corresponding number of calibration parameters. Below the header, the values extracted from the data is indicated. See the methods section for a detailed description. n, Table showing the formulas used to fit the data for the indicated figure panels.CC BY · PubMed Central
Extended Data Fig. 5 Crosstalk. a–f, In this experiment all qubits are initialized. We observed the presence of crosstalk by measuring the expectation values of the native observables on the sample. a–e, Rabi oscillations executed on different qubits in each panel. Panels b, c and e display coherent oscillations of nominally idle qubits, which are a clear indication of crosstalk at the chosen Rabi frequencies. Qubits Q1 and Q2 show flipped measurement outcomes due to a miscalibration of sensing dot 1. This bears no influence on the conclusion from this experiment. g, Example of qubit Q2 driven at the frequency determined by the synchronization condition. In this case the crosstalk to qubit Q5 (qubit with the closest resonance frequency) was nullified by design for every multiple of a 90 degree rotation. h, Expressions53 used to calculate the synchronization condition shown in panel g.
Extended Data Fig. 5 Crosstalk. a–f, In this experiment all qubits are initialized. We observed the presence of crosstalk by measuring the expectation values of the native observables on the sample. a–e, Rabi oscillations executed on different qubits in each panel. Panels b, c and e display coherent oscillations of nominally idle qubits, which are a clear indication of crosstalk at the chosen Rabi frequencies. Qubits Q1 and Q2 show flipped measurement outcomes due to a miscalibration of sensing dot 1. This bears no influence on the conclusion from this experiment. g, Example of qubit Q2 driven at the frequency determined by the synchronization condition. In this case the crosstalk to qubit Q5 (qubit with the closest resonance frequency) was nullified by design for every multiple of a 90 degree rotation. h, Expressions53 used to calculate the synchronization condition shown in panel g.CC BY · PubMed Central
Extended Data Fig. 6 Heating effects. a, A microwave burst of 16 GHz at 12 dBm output power and of a variable duration is applied before scanning the sensing dot virtual plunger gate. We observe no shift of the Coulomb peak, indicated by the white line, but the background signal increases substantially. Also the peak signal increases, but by a smaller amount. b, Linecut along the Coulomb peak and linecut parallel to the Coulomb peak of panel a, showing the peak and background signal as a function of the MW burst duration, for two different powers. The shaded area indicates the net signal, which is smaller the larger the applied power and the longer its duration. c, Variation on panel b, where we introduce a waiting time after the microwave burst, as indicated in the schematic. The longer the wait time, the more the original SNR is recovered, and the higher the readout fidelity will be. d, Rabi oscillations with different waiting times introduced before the qubit readout. The 500 μs wait time allows for recording long lived Rabi oscillations, while with no wait time prior readout, the contrast vanishes as the perceived spin fraction converge towards 1, due to shifts in the sensing dot signal and background (the threshold for single-shot analysis was kept fixed). e, Schematic showing the circuit used to investigate the effect of a pre-pulse (labelled MW burst (t)) on the qubit properties. A microwave burst of 6 dBm is applied before running a Ramsey experiment. We extract the change in T2^(*) and Larmor frequency for qubit Q5 for different microwave burst times as shown in the plots. f Return loss of the RF readout circuit for different powers of continued microwave driving (i.e. driving at the qubit frequencies, not for the RF readout). We observe both a shift in the RF resonance frequency and a degradation of the quality factor with higher power excitation. g, Extracted dephasing times T2^(*) with and without pre-pulse (4 μs, 6 dBm), measured as illustrated in e.
Extended Data Fig. 6 Heating effects. a, A microwave burst of 16 GHz at 12 dBm output power and of a variable duration is applied before scanning the sensing dot virtual plunger gate. We observe no shift of the Coulomb peak, indicated by the white line, but the background signal increases substantially. Also the peak signal increases, but by a smaller amount. b, Linecut along the Coulomb peak and linecut parallel to the Coulomb peak of panel a, showing the peak and background signal as a function of the MW burst duration, for two different powers. The shaded area indicates the net signal, which is smaller the larger the applied power and the longer its duration. c, Variation on panel b, where we introduce a waiting time after the microwave burst, as indicated in the schematic. The longer the wait time, the more the original SNR is recovered, and the higher the readout fidelity will be. d, Rabi oscillations with different waiting times introduced before the qubit readout. The 500 μs wait time allows for recording long lived Rabi oscillations, while with no wait time prior readout, the contrast vanishes as the perceived spin fraction converge towards 1, due to shifts in the sensing dot signal and background (the threshold for single-shot analysis was kept fixed). e, Schematic showing the circuit used to investigate the effect of a pre-pulse (labelled MW burst (t)) on the qubit properties. A microwave burst of 6 dBm is applied before running a Ramsey experiment. We extract the change in T2^(*) and Larmor frequency for qubit Q5 for different microwave burst times as shown in the plots. f Return loss of the RF readout circuit for different powers of continued microwave driving (i.e. driving at the qubit frequencies, not for the RF readout). We observe both a shift in the RF resonance frequency and a degradation of the quality factor with higher power excitation. g, Extracted dephasing times T2^(*) with and without pre-pulse (4 μs, 6 dBm), measured as illustrated in e.CC BY · PubMed Central
Extended Data Fig. 7 Experiment setup. a, Schematic overview of the experimental setup. The bulk of the experiment is controlled by Arbitrary Waveform Generators (AWG, Keysight M3202A) and digitizers (DIG, Keysight M3201A) in a PXI chassis (used for synchronization and feedback). The AWG’s generate baseband pulses (0-300MHz) used for readout and two-qubit gates. These baseband signals are provided to all plunger and barrier gates of the quantum dots. Sensing dot plungers are also connected to AWG channels to allow for fully compensated virtual plungers. In addition, we use the AWG’s to generate the IQ input signals for the vector source (Keysight PSG E8267D), used to perform single-qubit gates. Using this source, a large IQ modulation bandwidth (800 MHz) can be obtained by using the differential IQ inputs. The differential signal is generated using Balun’s (Marki bal-0006), which reduce the number of AWG channels and ensure excellent timing (AWG channel pairs 1,2 and 3,4 have a larger skew ( ± 30 ps) compared to just channel 1 and 2). We use a homemade combiner to allow for both baseband and MW control on the EDSR driving gate. Coils with ferrite cores are used to reduce low-frequency noise generated by the instruments. In addition, we use double DC blocks for any RF/MW signal used in this experiment. The schematic shows in yellow the different temperature stages of the dilution refrigerator at which the signals are attenuated and thermalized. All plunger gates have discrete attenuators in the line with a total attenuation of ~ 28 dB, and barrier gates of ~ 20 dB in addition to the attenuation from the coax line itself. The barriers gates have less attenuation because of the large voltage pulses needed to achieve the desired Jon/Joff ratio. We use bias tees on the sample PCB with a RC time constant of 100 ms to combine baseband and microwave signals with a static DC voltage. We generate the carrier signal using a homemade RF source (one carrier per sensing dot), which we route into the dilution refrigerator using a combiner. A marker output channel of the AWG’s is connected to the the RF sources in order to only output RF power during the readout. At the 10 mK stage, we use a directional coupler to separate the reflected signal (S11) from the incoming RF carrier. A coplanar waveguide routing the RF signal on the sample PCB is split in two and connects to bias tees, each one going to a sensing dot. Bias tees with a low resistance are chosen as it also allows us to perform DC measurements as needed. NbTiN inductors (low Cp, high Q) are wire-bonded directly to the source contacts on the sample29,56 (see Supplementary Information). When the carrier signal reflects from the sensing dots, it passes again through the directional coupler and is amplified both at the 4 Kelvin stage and at room temperature. The signal is fed through two sets of mixers (1 for each SD) to demodulate the signal to baseband. We finally sample the I and Q channels with the digitizer in the PXI chassis. On the FPGA, we average the signal for a specified amount of time and optionally convert it into a boolean value using a threshold (see Extended Data figure 8). Besides the fast baseband/RF/MW pulses, all the gates of the sample are also connected to battery-powered DACs built in-house, which supply the DC operating voltages. These DACs are very stable voltage sources that provide an 18-bit voltage resolution over a ± 2 V range. b, Image of the PCB used to mount the sample. The DC signals are supplied via the white flat-flexible-cable connector located on the left side of the PCB. The 17 SMP connectors provide the signals used for qubit readout and single- and two-qubit gates. We use bias tees to combine the AC and DC signals. A laser diode is placed in the top right corner of the PCB, which can be used to ’reset’ the device (not used in this experiment). In the zoomed-in image in red, the qubit chip and two smaller chips with NbTiN high-kinetic inductance inductors are visible.
Extended Data Fig. 7 Experiment setup. a, Schematic overview of the experimental setup. The bulk of the experiment is controlled by Arbitrary Waveform Generators (AWG, Keysight M3202A) and digitizers (DIG, Keysight M3201A) in a PXI chassis (used for synchronization and feedback). The AWG’s generate baseband pulses (0-300MHz) used for readout and two-qubit gates. These baseband signals are provided to all plunger and barrier gates of the quantum dots. Sensing dot plungers are also connected to AWG channels to allow for fully compensated virtual plungers. In addition, we use the AWG’s to generate the IQ input signals for the vector source (Keysight PSG E8267D), used to perform single-qubit gates. Using this source, a large IQ modulation bandwidth (800 MHz) can be obtained by using the differential IQ inputs. The differential signal is generated using Balun’s (Marki bal-0006), which reduce the number of AWG channels and ensure excellent timing (AWG channel pairs 1,2 and 3,4 have a larger skew ( ± 30 ps) compared to just channel 1 and 2). We use a homemade combiner to allow for both baseband and MW control on the EDSR driving gate. Coils with ferrite cores are used to reduce low-frequency noise generated by the instruments. In addition, we use double DC blocks for any RF/MW signal used in this experiment. The schematic shows in yellow the different temperature stages of the dilution refrigerator at which the signals are attenuated and thermalized. All plunger gates have discrete attenuators in the line with a total attenuation of ~ 28 dB, and barrier gates of ~ 20 dB in addition to the attenuation from the coax line itself. The barriers gates have less attenuation because of the large voltage pulses needed to achieve the desired Jon/Joff ratio. We use bias tees on the sample PCB with a RC time constant of 100 ms to combine baseband and microwave signals with a static DC voltage. We generate the carrier signal using a homemade RF source (one carrier per sensing dot), which we route into the dilution refrigerator using a combiner. A marker output channel of the AWG’s is connected to the the RF sources in order to only output RF power during the readout. At the 10 mK stage, we use a directional coupler to separate the reflected signal (S11) from the incoming RF carrier. A coplanar waveguide routing the RF signal on the sample PCB is split in two and connects to bias tees, each one going to a sensing dot. Bias tees with a low resistance are chosen as it also allows us to perform DC measurements as needed. NbTiN inductors (low Cp, high Q) are wire-bonded directly to the source contacts on the sample29,56 (see Supplementary Information). When the carrier signal reflects from the sensing dots, it passes again through the directional coupler and is amplified both at the 4 Kelvin stage and at room temperature. The signal is fed through two sets of mixers (1 for each SD) to demodulate the signal to baseband. We finally sample the I and Q channels with the digitizer in the PXI chassis. On the FPGA, we average the signal for a specified amount of time and optionally convert it into a boolean value using a threshold (see Extended Data figure 8). Besides the fast baseband/RF/MW pulses, all the gates of the sample are also connected to battery-powered DACs built in-house, which supply the DC operating voltages. These DACs are very stable voltage sources that provide an 18-bit voltage resolution over a ± 2 V range. b, Image of the PCB used to mount the sample. The DC signals are supplied via the white flat-flexible-cable connector located on the left side of the PCB. The 17 SMP connectors provide the signals used for qubit readout and single- and two-qubit gates. We use bias tees to combine the AC and DC signals. A laser diode is placed in the top right corner of the PCB, which can be used to ’reset’ the device (not used in this experiment). In the zoomed-in image in red, the qubit chip and two smaller chips with NbTiN high-kinetic inductance inductors are visible.CC BY · PubMed Central
Extended Data Fig. 8 Implementation of real time feedback. a, The sensing dot signal obtained via RF reflectometry arrives at the digitizer on two input channels (I and Q). The digitizer rotates the combined I and Q input with an angle Δϕ and converts the vector into a scalar by dropping the Q signal. Upon a trigger from the instruction sequence, the signal is averaged for a time tmeasure and compared with a threshold to infer the qubit state. The result is written both to the DRAM and the PXI trigger line. b, We use IQ modulation to shape the MW pulses that are used for EDSR qubit control. The waveform memory stores the amplitude (envelope) and phase information for all the microwave bursts used in the experiment, as well as for the necessary single-qubit phase corrections. We upload waveforms for microwave bursts corresponding to X90, X−90, Y90 and Y−90 rotations for each qubit. The pulse table contains the start and stop memory addresses of each control pulse present in the waveform memory. For every single-shot experiment, the AWG steps through the instruction sequence, which defines all the single-qubit gate pulses that need to be executed during the experiment. When the offset flag of an instruction in the instruction sequence is 1, the current value on the PXI trigger (0/1) is added to the pulse number that will be played from the pulse table. This bitwise addition implements real-time feedback. In the present experiment, either X90 bursts will be executed or zero amplitude bursts, depending on the PXI trigger value. When an instruction sequence is ran, the amplitude and phase information are read from the waveform memory for the selected pulse numbers one after the other. The differential phase (Δ phase) is added for every rendered sample to the phase accumulator (which controls the qubit frequency) and is then converted to an in-phase (I) and quadrature (Q) signal by the phase-to-amplitude converters (PAC). These I and Q signals are multiplied with the amplitude envelope of the waveform and are then passed to the outputs of the AWG and from there to the vector source. We can run up to twelve sequencers in parallel in a single AWG. In this case 6 sequencers are used, one for every qubit.
Extended Data Fig. 8 Implementation of real time feedback. a, The sensing dot signal obtained via RF reflectometry arrives at the digitizer on two input channels (I and Q). The digitizer rotates the combined I and Q input with an angle Δϕ and converts the vector into a scalar by dropping the Q signal. Upon a trigger from the instruction sequence, the signal is averaged for a time tmeasure and compared with a threshold to infer the qubit state. The result is written both to the DRAM and the PXI trigger line. b, We use IQ modulation to shape the MW pulses that are used for EDSR qubit control. The waveform memory stores the amplitude (envelope) and phase information for all the microwave bursts used in the experiment, as well as for the necessary single-qubit phase corrections. We upload waveforms for microwave bursts corresponding to X90, X−90, Y90 and Y−90 rotations for each qubit. The pulse table contains the start and stop memory addresses of each control pulse present in the waveform memory. For every single-shot experiment, the AWG steps through the instruction sequence, which defines all the single-qubit gate pulses that need to be executed during the experiment. When the offset flag of an instruction in the instruction sequence is 1, the current value on the PXI trigger (0/1) is added to the pulse number that will be played from the pulse table. This bitwise addition implements real-time feedback. In the present experiment, either X90 bursts will be executed or zero amplitude bursts, depending on the PXI trigger value. When an instruction sequence is ran, the amplitude and phase information are read from the waveform memory for the selected pulse numbers one after the other. The differential phase (Δ phase) is added for every rendered sample to the phase accumulator (which controls the qubit frequency) and is then converted to an in-phase (I) and quadrature (Q) signal by the phase-to-amplitude converters (PAC). These I and Q signals are multiplied with the amplitude envelope of the waveform and are then passed to the outputs of the AWG and from there to the vector source. We can run up to twelve sequencers in parallel in a single AWG. In this case 6 sequencers are used, one for every qubit.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Research works printed but not linked: 1

  1. Harvey-Collard P High-fidelity single-shot readout for a spin qubit via an enhanced latching mechanism Phys. Rev. X 2018 8 021046

Cited by

See all 467

Metadata

Authors
Philips, S. G. J., Mądzik, M. T., Amitonov, S. V., de Snoo, S. L., Russ, M., Kalhor, N., Volk, C., Lawrie, W. I. L., Brousse, D., Tryputen, L., Wuetz, B. P., Sammak, A., Veldhorst, M., Scappucci, G., & Vandersypen, L. M. K.
Affiliations
  • QuTech (NL)
  • Netherlands Organisation for Applied Scientific Research (NL)
Corresponding author
Vandersypen, Lieven M. K.
Venue
Nature
Published
2022-09-28
Volume
609
Issue
7929
Pages
919-924
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4297473634
Cited by
410
References
64
Citations by year
2026: 58 · 2025: 117 · 2024: 121 · 2023: 94 · 2022: 20
FWCI
36.09
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • TNO Repository (submittedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • Research Repository (Delft University of Technology) (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion, cc-by)
  • arXiv (Cornell University) (cc-by)
Funders
  • U.S. Department of Energy (DE‐FG02‐, FG0203ER46028, DEFG0203ER46028)
  • Keysight Technologies
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWA.1292.19.194)
  • Army Research Office (W911NF‐17‐1‐0274, W911NF, W911NF1210607)
  • H2020 Marie Skłodowska-Curie Actions (676108)
Topics
  • Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Quantum and electron transport phenomena
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Semiconductor Quantum Structures and Devices
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
Keywords
silicon quantum dots, semiconductor spin qubits, Hamiltonian engineering, background calibration, real-time feedback, quantum non-demolition measurement, state preparation and measurement, gate fidelity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Universal control of a six-qubit quantum processor in silicon. https://app.cochat.ai/papers/10.1038/s41586-022-05117-x
The paper
Philips, S. G. J., Mądzik, M. T., Amitonov, S. V., de Snoo, S. L., Russ, M., Kalhor, N., Volk, C., Lawrie, W. I. L., Brousse, D., Tryputen, L., Wuetz, B. P., Sammak, A., Veldhorst, M., Scappucci, G., & Vandersypen, L. M. K. (2022). Universal control of a six-qubit quantum processor in silicon. Nature. https://doi.org/10.1038/s41586-022-05117-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.