A wearable cardiac ultrasound imager
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Continuous imaging of cardiac functions is highly desirable for the assessment of long-term cardiovascular health, detection of acute cardiac dysfunction and clinical management of critically ill or surgical patients 1–4 . However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness 5–11 , and existing wearable cardiac devices can only capture signals on the skin 12–16 . Here we report a wearable ultrasonic device for continuous, real-time and direct cardiac function assessment. We introduce innovations in device design and material fabrication that improve the mechanical coupling between the device and human skin, allowing the left ventricle to be examined from different views during motion. We also develop a deep learning model that automatically extracts the left ventricular volume from the continuous image recording, yielding waveforms of key cardiac performance indices such as stroke volume, cardiac output and ejection fraction. This technology enables dynamic wearable monitoring of cardiac performance with substantially improved accuracy in various environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures













Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Analyze ultrasound echoes to track muscle | morphological dynamics and infer joint | movement 214 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [116]
Experimental — accuracy not yet measuredIn the citing paper
“Based on this, dynamic changes in muscle strength can be analyzed 116,117 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [116]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Reinforcement Learning: A Survey
Kaelbling, L. P., Littman, M. L., & Moore, A. W. (1996) · Journal of Artificial Intelligence Research · doi:10.1613/jair.301 · Cited by 8,972
Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography
Schiller, N. B., Shah, P. M., Crawford, M., DeMaria, A., Devereux, R., Feigenbaum, H., Gutgesell, H., Reichek, N., Sahn, D., Schnittger, I., et al. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80014-8 · Cited by 8,121
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153 · cited 1×
“x N Δ = imaging width − 1 (3) pixel,lateral”
Background3D Printing of Free Standing Liquid Metal Microstructures
Ladd, C., So, J., Muth, J., & Dickey, M. D. (2013) · Advanced Materials · doi:10.1002/adma.201301400 · Cited by 926
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Self-citationGhorbanzadeh, O., Blaschke, T., Gholamnia, K., Meena, S. R., Tiede, D., & Aryal, J. (2019) · Remote Sensing · doi:10.3390/rs11020196 · Cited by 875
Research works printed but not linked: 2
- García-González, M. A., Argelagós-Palau, A., Fernández-Chimeno, M. & Ramos-Castro, J. in Computing in Cardiology 2013 461–464 (IEEE, 2014).
- Sung, F. et al. in Proc. 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition 1199–1208 (IEEE, 2018).
Cited by
Items 401–500 of 644
Wu, Y., Shang, D., Li, Y., Ku, S., Yao, J., Wu, D., & Chen, J. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107804 · Cited by 3
Arbitrarily Shapeable Couplant with Fluidity Onset for Conformal Ultrasound
Chen, J., Hua, Y., Jin, B., Zhan, Z., Zhang, M., Zhang, Y., Jin, R., Liang, X., Cao, R., Hu, X., et al. (2025) · Advanced Materials · doi:10.1002/adma.202505620 · Cited by 5
Wearable Smart Textile Band for Continuous Equine Health Monitoring
Park, T., Hong, S., Murray, L., Lee, J., Shah, A., Mesa, J. C., Lee, H., Couetil, L., & Lee, C. H. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118073 · Cited by 5
Liquid metal‐enabled energy generators for self‐powered soft bioelectronics
Li, S., Zhao, K., Zan, G., Kim, G., Kim, H., Shin, E., Kwon, M., Kim, Y., Jang, J., Yoo, J., et al. (2025) · Rare Metals · doi:10.1007/s12598-025-03607-1 · Cited by 8
Xie, H., Huang, Q., Yu, H., Qu, Y., Yuan, M., Wu, H., Wang, J., Zhu, Z., & Li, Z. (2025) · Information Fusion · doi:10.1016/j.inffus.2025.103957 · Cited by 6
Self-citationAvenues for optimization of cardiac therapeutics by minimally invasive delivery
Li, Y., Menasché, P., Vunjak‐Novakovic, G., & Cheng, K. (2026) · Acta Biomaterialia · doi:10.1016/j.actbio.2026.01.033 · Cited by 4
Hydrogel metapad with ultrasound transparency and broadband focusing for biomedical imaging
Zhang, J. Y., Yu, D., Zhang, T., Gao, C., Dong, E., Song, Z., Fan, C., Han, Z., Lemoult, F., Fink, M., et al. (2026) · National Science Review · doi:10.1093/nsr/nwag048 · Cited by 5
“Existing acoustic lens [27 ,41 –45 ] and wearable ultrasound devices [2 ,3 ,16 ,22 ,24 ,40 ] lack one or more of the ideal properties required ( Tables S1 and S3).”
A Self-adaptive ultrasound patch for transcranial multimodal dynamic focusing
Ku, S., Wu, Y., You, C., Li, Y., Cao, T., Wu, D., & Chen, J. (2026) · Ultrasonics · doi:10.1016/j.ultras.2026.108036 · Cited by 3
Li, H., Li, Z., Yang, J., Wu, J., Chen, Y., Wu, L., Hu, H., Gao, P., & Qu, Y. (2026) · Advanced Science · doi:10.1002/advs.202524261 · Cited by 3
“However, this field remains less mature than air-mediated vibration and noise control [ 4 ] or ultrasound imaging [ 5, 6 ].”
Self-citationHuang, Q., Shuaigang, S., Wang, M., Wu, Y., He, Q., Wei, H., Sai, H., & Huang, T. (2026) · Ceramics International · doi:10.1016/j.ceramint.2026.04.388 · Cited by 5
PZT-based flexible ultrasonic sensor arrays for nondestructive testing applications
Wang, H., Wu, Y., Guo, K., Liu, W., Sun, C., Si, S., Chen, L., Li, P., Li, J., & Yang, J. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117995 · Cited by 3
Yan, M., Wang, Z., Li, Z. K., Wang, P., Wu, P., Chen, X., Chen, X., Du, L., Wang, Y., Song, J., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01158-8 · Cited by 7
Self-citationAI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring
Dong, L., Zhang, X., Li, M., Li, Y., guo, J., Lu, S., Peng, Z., Zheng, C., 惠宇飞, shao, X., et al. (2026) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0653 · Cited by 3
Self-citationCheng, D., Yue, Q., Hang, H., Li, J., Zhou, Z., & Liang, R. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114749 · Cited by 4
Fast capturing of deep blood flow
Gao, R., Xu, Z., & Liu, C. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01162-7 · Cited by 3
Wearable sensing of solid analytes
Qin, S., & Xu, S. H. (2024) · Nature Materials · doi:10.1038/s41563-024-01935-8 · Cited by 5
Self-citationFlexible Magnetoelectric Nanomaterials for Healthcare Devices: A Minireview
Liang, W., Li, Y., Pan, Y., Zhang, J., & Liu, N. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.4c03803 · Cited by 4
Nuevas técnicas ecográficas. Presente y futuro
Clau-Terré, F., Pereira, R. V., Azcárate, J. M. A., & Bailén, M. R. (2024) · Medicina Intensiva · doi:10.1016/j.medin.2024.07.011 · Cited by 3
Wearable Ultrasound Blood Pressure Monitoring System for Cardiovascular Health
Chu, Y., Xue, X., Liu, S., Wu, H., Kreager, B. C., Biliroğlu, A. Ö., Oralkan, Ö., & Jiang, X. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793899 · Cited by 3
“Such developments have paved the way for integrating ultrasound in long-term health monitoring applications, including muscle activity detection [4], cardiac imaging [5], continuous organ imaging [6], and functional electrical stimulation [7].”
A wearable ultrasonic device to image cardiac function
Lim, G. B. (2023) · Nature Reviews Cardiology · doi:10.1038/s41569-023-00843-9 · Cited by 3
Intrinsically stretchable porous liquid–metal conductor for multifunctional electronics applications
Sun, X., Yin, M., Xu, R., Fu, Z., Zhu, H., Guo, Q., Li, Y., Li, C., Li, Y., & Qian, K. (2023) · Journal of Materials Chemistry C · doi:10.1039/d3tc03531j · Cited by 3
Self-citationCarlier, B., Heymans, S. V., Collado‐Lara, G., Musetta, L., Ingram, M., Toumia, Y., Paradossi, G., Vos, H. J., Roskams, T., D’hooge, J., et al. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad7e76 · Cited by 3
Ruan, T., Wang, L., Wang, Q., Xu, Q., Cao, J., Jiang, C., Xu, M., Zhu, X., Liu, Q., Yang, B., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202418633 · Cited by 3
Shape Estimation of Flexible Probe using Spatial-Attention FlexShapeNet
Gao, X., Huang, L., Wang, Y., & Guo, Y. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793491 · Cited by 2
“Based on the current materials and equipment for flexible probes, the maximum convex curvature is set at 0.02 mm -1 [5], [6].”
InfluentialSelf-citationLv, J., Yang, Y., Cui, M., Liu, H., Xu, B., & Gao, X. (2025) · Acta Mechanica Solida Sinica · doi:10.1007/s10338-024-00566-5 · Cited by 2
Self-citationThree-dimensional structure of entire hydrated murine hearts at histological resolution
Frohn, J., Böddeker, F., Reichardt, M., Bruns, H., Czajka, T., Khan, A., Broche, L., Krisch, M. H., Bravin, A., Alves, F., et al. (2025) · Scientific Reports · doi:10.1038/s41598-024-83853-y · Cited by 2
Chen, Y., Bao, X., He, H., & Zhang, Q. (2024) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.01.019 · Cited by 3
Self-citationWearable Ultrasound: Are We Ready to Take This Chance for Vascular Ageing Assessment?
Bianchini, E., Bruno, R. M., Badhwar, S., Faita, F., Mayer, C. C., & Gemignani, V. (2025) · Artery Research · doi:10.1007/s44200-025-00069-9 · Cited by 3
“Other studies indicate the feasibility of wearable ultrasound during dynamic conditions such as exercise [17].”
InfluentialPiezoelectric gauge transformation for inverse design of polar Willis transducers
Huang, L. J., Zhu, R., Hu, G., & Chen, Y. (2025) · Extreme Mechanics Letters · doi:10.1016/j.eml.2025.102315 · Cited by 2
Self-citationEvaluation of a Dual Linear Flexible Ultrasound Array for Surgical Interventional Guidance
Rostamikhanghahi, H., Ingram, M., Booth, B. G., & D’hooge, J. (2025) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2025.3560938 · Cited by 2
“While flexible array technologies have been explored in various medical applications [4], [5], [6], [7], there have been no studies specifically focused on wearable devices for the wrist and, in particular, Percutaneous Scaphoid Fixation (PSF) surgery.”
Shao, W., Wang, Y., Wu, D., Gao, Q., Shokouhimehr, M., & Liu, Z. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3578177 · Cited by 3
Li, Y., Yang, Z., Liu, L., Wu, S., Jiao, Y., & Cui, Y. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3592907 · Cited by 2
“Consequently, F-WUS probe can form a good conformal relationship with complex skin shapes, addressing the pain point of poor conformability associated with rigid probes [19], [20], [21], [22], [23].”
Nozdriukhin, D. V., Chen, Y., Lyu, S., Razansky, D., & Deán‐Ben, X. L. (2025) · Advanced Science · doi:10.1002/advs.202502298 · Cited by 5
Self-citationDirect Fabrication of Robust Flexible Electronics Via Laser Shock Imprinting
Yang, Z., Cai, Z., Yu, Z., Chen, X., Li, J., Zhang, C., Hu, Z., Deng, H., Yi, Y., & Zhang, C. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202519191 · Cited by 7
Self-citationFlexible AlScN based PMUT arrays for conformal and wearable ultrasound
Georgitzikis, E., Gijsenbergh, P., Massimino, G., Ukropec, R., Pandit, M., Segers, J., Wysocka, D., Lancker, D. V., Shen, Z., Keulemans, G., et al. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201418 · Cited by 2
“Previous approaches towards flexible transducers include piezocomposites with stretchable matrix [11], organic piezoelectric materials like polyvinylidene [12] or spring-shaped silicon hinges in between MUT subarrays or integrating these subarrays on an elastic substrate [13], [14].”
UltraFlex: Iterative Model-Based Ultrasonic Flexible-Array Shape Calibration
Frey, B. N., Hyun, D., Simson, W. A., Zhuang, L. L., Hashemi, H. S., Schneider, M. K., & Dahl, J. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3627525 · Cited by 2
“Human-wearable flexible-array device studies have been designed for assessing cardiac dysfunction via cardiac output, ejection fraction, and stroke volume [3].”
You, L., 瞿亦容, Chen, Y., Wang, Y., Shen, L., & Ge, J. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00537-5 · Cited by 3
“Flexible ultrasound patches, created by embedding micro-fabricated fl exible ultrasonic transducer arrays into fl exible substrates, exhibit excellent tissue conformity and wearability 81 – 83 , contributing signi fi cantly to the miniaturization of ultrasound imaging systems 84 – 87 (Fig.”
Self-citationChuma, A. T., Mekonnen, D., Voigt, J., Asmare, M. H., Youssef, A., Varon, C., Willems, R., Yates, M. L., Petros, A., Asrat, Y., et al. (2026) · JMIR Public Health and Surveillance · doi:10.2196/87039 · Cited by 2
“Recent advancements in wearable ultrasounds for cardiac imaging have demonstrated potential to make imaging more cost-effective while maintaining comparable performance to that of standard portable echocardiography devices [33].”
Advances in principles and technologies of non-mechanical blood pressure monitoring
Zheng, Z., Hao, H., Huang, Y., Lyu, R., Ma, H., Zhang, Y., Liu, J., Shao, C., & Zhou, A. (2026) · npj Cardiovascular Health · doi:10.1038/s44325-025-00102-5 · Cited by 3
Bioresorbable acoustic patch for simultaneous sealing and early detection of gastric leakage
Hu, J., Xu, J., Meng, H., Guan, K., Li, Y., Liu, Z., & Shen, G. (2026) · Science Advances · doi:10.1126/sciadv.aec6857 · Cited by 3
“In comparison, wearable ultrasound technology circumvents the aforementioned issues by virtue of its superior tissue penetration and radiation-free operation ( 20 – 23 ).”
System architecture control design and clinical translation in closed-loop drug delivery
Qin, W., Cui, Y., Wang, H., Zhang, Y., & Cheng, Z. (2026) · Materials Today Chemistry · doi:10.1016/j.mtchem.2026.103601 · Cited by 2
Xu, G., Xiong, D., Fan, Y., Niu, L., Tingting, Z., Ma, R., Zhang, W., Tang, Y., Lin, D., Yang, X., et al. (2026) · Acta Biomaterialia · doi:10.1016/j.actbio.2026.05.003 · Cited by 2
Self-citationAdvanced ambulatory and continuous sensing technologies for cardiovascular connected healthcare
Ke, Y., Li, J., Li, T., Xu, W., Ni, D., Ye, X., Li, Z., Yang, F., & Wang, Z. L. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112011 · Cited by 2
Wearable ultrasound: Recent advances and applications in biomedical engineering
Zhang, X., Li, K., Fan, X., Wang, S., Liu, T., Chen, Y., He, X., Chen, H., Xie, J., Liu, L., et al. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100134 · Cited by 4
Self-citationChen, Z., Wang, X., Wang, Z., Wan, J., Xu, J., Su, H., & Hua, Q. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112032 · Cited by 2
Self-citationSynchronous wearable ultrasound for early detection of coronary and carotid artery comorbidity
Lin, S., Xu, H., Li, Y., Ge, X., Chen, K., Chen, L., Tong, M., Wang, F., Wu, D., Lin, H., et al. (2026) · Science Advances · doi:10.1126/sciadv.aed2114 · Cited by 2
“Last, the Verasonics system used in this study is limited for continuous and wearable monitoring, as it is not portable and relies on wired connections despite the fact that notable studies have used Verasonics systems for image acquisition ( 19 , 21 ).”
InfluentialResearch progress on liquid metal in biomedicine
Wang, C., Zeng, M., & Fu, L. (2023) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2023-0216 · Cited by 2
Influence of Contact Characteristics on Pressure Sensing of IPMC Sensors
Tang, G., Zhao, X., Ji, Y., Zhao, C. S., Mei, D., & Wang, Y. (2023) · Lecture notes in computer science · doi:10.1007/978-981-99-6483-3_11 · Cited by 2
Giordano, M., Keller, K., Greco, F., Luca Benini, C., Magno, M., & Leitner, C. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388792 · Cited by 2
“Recent works show possible applications of ultrasound technology in the realm of wearable monitoring of hemodynamics [4] and organs [1], [5], in prosthetic controls [6] as well as in human-machine interfaces (HMI) [7].”
BackgroundSitek, A. (2024) · Radiology Artificial Intelligence · doi:10.1148/ryai.240093 · Cited by 3
Lin, Y., Alemu, M. Y., Shi, B., Nanayakkara, T., & Shull, P. B. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3413134 · Cited by 2
“As an emerging field—the fusion of acoustics and soft/flexible materials [21], [22], it holds significant academic significance and provides guidance for subsequent material selection.”
BackgroundLi, H., Hu, X., Xu, X., Ma, Y., Yu, C., Wei, W., & Niu, P. (2024) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ad690d · Cited by 2
Self-citationJi, Y., Wang, H., Yang, G. M., & Bi, Q. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107428 · Cited by 2
Kim, Y., Kim, J. H., Ryu, Y. H., Ha, H., Lee, S. J., Lee, S. C., Lim, C., Moon, S., & Kim, H. H. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3529728 · Cited by 2
“…in several studies [24], [25], [26], [27], aimed at reducing the clinician’s burden and enabling real-time monitoring of vital parameters such as blood pressure from the carotid artery [26], cardiovascular health [28], bladder volume [29], and liver status for acute liver failure diagnosis [30].”
Information Processing via Human Soft Tissue: Soft Tissue Reservoir Computing
Kobayashi, Y. (2025) · IEEE Access · doi:10.1109/access.2025.3553140 · Cited by 5
“The miniaturization and flexibility of the ultrasound sensors (for example, [41], [42], [43]), coupled with technology to implement linear readouts as devices, enable information processing using human tissue, eliminating the need for other computers based on the Turing machine.”
Advancements in delivering RNA therapies using physical transdermal drug delivery methods
Nimrawi, S., Al‐Nemrawi, N. K., & Kwon, Y. M. (2025) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2025.107587 · Cited by 2
Flexible Stencil-Printed Piezoelectric Transducer Arrays for Catheter Based Ultrasound Applications
Karahasanoglu, B., Bradley, L. W., Snyder, H. H., Atasoy, B., Yaras, Y. S., & Degertekin, F. L. (2023) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps57599.2023.10220221 · Cited by 2
“Recently, application of ultrasound transducers in medicine has expanded beyond traditional external probe based medical imaging, with applications ranging from non-invasive, wearable ultrasound devices [1, 2] to catheter-based intravascular and intracardiac ultrasound imaging [3-5].”
BackgroundUltrasound Imaging with Pre-charged Collapse-Mode CMUTs
Kawasaki, S., Saccher, M., de Wijs, W.-J., van den Brand, J., & Dekker, R. H. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10307216 · Cited by 2
“A broad application area is anticipated as well: ranging from intermittent monitoring of the human bladder volume for incontinence care [4] to continuous monitoring of the cardiac functions for managing critically ill or surgical patients [5].”
BackgroundPoint-of-Care Echocardiographic Evaluation of the Pericardium
Butcher, A., & Castillo, C. (2023) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2023.12.009 · Cited by 1
Chen, M., Salloum, R. G., & Song, H. (2024) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2024.04.031 · Cited by 1
An Exploration into the Structuring of Soft Piezoelectric Transducers for Wearable Applications
Peters, L. C. J. M., Verbeek, R., de Haas, G., Gelinck, G. H., Schrama, T., Volker, A. W. F., Merks, E. J. W., & Neer, P. L. M. J. V. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596854 · Cited by 1
“…systems have been published so far, which typically either consist of an array of micro-assembled rigid piezoelectric transducer on to a flexible substrate [1-3] or consist of a relatively small rigid transducer array which is coupled directly to the skin using a bio-adhesive coupling gel [4].”
MethodMicroprotrusion Decorated Solid Coupling for Long-Term Wearable Ultrasound Monitoring
Ma, Y., Lin, Q., Xu, X., Zhang, L., Pang, W., Wei, W., Yu, C., & Niu, P. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793895 · Cited by 1
“However, these liquid agents can dry [5], making it unable to work for long term, which is against the motivation of wearable devices and frequently adding liquids coupling agents are impracticable.”
Self-citation35.2 A Spatial-Domain Compressive-Sensing Photoacoustic Imager with Matrix-Multiplying SAR ADC
Liao, H.-C., Zhang, S., Su, Y., Govinday, A., Zou, Y., Wang, W., Boominathan, V., Veeraraghavan, A., Li, L. S., & Yang, K. (2025) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc49661.2025.10904572 · Cited by 1
Boutros, P., Kassem, N., & Barteit, S. (2025) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2025.05.006 · Cited by 2
Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs
Radeljic-Jakic, N., Flikweert, A. J., Rozsa, N. N. M., Vos, H. J., & Pertijs, M. A. P. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3577258 · Cited by 2
“These devices are usually attached to a fixed position on a patient’s body with an adhesive for long-term monitoring without the need for an operator or the usual movement restrictions that apply during a clinical procedure [5], [6].”
Qiu, M., Hu, C., Sun, X., Liu, M., Jin, S., Shan, Q., Xu, Z., Meng, X., Tan, P., Wang, Y., et al. (2025) · Applied Physics Letters · doi:10.1063/5.0274051 · Cited by 1
Design of Wearable Flexible Cross-Shaped Ultrasonic Transducer Array for Blood Pressure Estimation
Su, M., Dong, L., Wang, S., Cui, Y., Zhang, M., Gao, Y., Liu, C., Yang, W., Cheng, J., Yan, H., et al. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3585406 · Cited by 1
“…Wang et al. [15] developed a 12 × 12 flexible piezoelectric transducer array to monitor hemodynamic signals in multiple tissues, and Hu et al. [19] proposed a transducer array for cardiac imaging; however, the electrode structures of these transducer arrays are too complex, requiring…”
Design, Fabrication, and Characterization of a PMN-PT Based Ultrasound Transducer
Zaidi, S. T. H., Kim, D. H., Shah, M. A., Lee, Y. J., Lee, B. C., & Hur, S. (2025) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps65444.2025.11105653 · Cited by 1
Wavy-microstructure-sandwiched flexible composite towards wearable monitoring and acoustic detecting
Li, D., Li, Z., Duan, S., Lou, C., Li, W., Fan, Z., Gong, X., Ma, H., & Xuan, S. (2025) · Composites Part B Engineering · doi:10.1016/j.compositesb.2025.113023 · Cited by 1
Zhang, J., Li, Q., Li, J., Zhang, Y., Shen, Y., Zeng, L., Sun, G., & Xiao, C. (2025) · Materials Research Bulletin · doi:10.1016/j.materresbull.2025.113774 · Cited by 4
Ramadhan, R., Akbar, I. A., & Samopa, F. (2025) · International Conference on Advanced Machine Learning and Data Science (AMLDS) · doi:10.1109/amlds63918.2025.11159354 · Cited by 1
Fu, X., Zhang, Z., Lin, W., Luo, Q., Zeng, L., Wen, Y., Ji, X., & Cheng, Z. (2025) · Medical Physics · doi:10.1002/mp.70009 · Cited by 1
“18,19 As fundamental research advances, the demands for ultrasound technology are concurrently increasing.”
Zhang, Z., Yang, L., Xu, J., Liu, Z., Luo, H., & Liu, L. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3611864 · Cited by 1
“Therefore, it is necessary to design a matching layer configuration between the single crystal and the medium under examination to enable an effective transition of acoustic impedance [24], [25], [26], [27], [28].”
Wearable ultrasound monitoring in minimally invasive cardiac surgery: A case report
Zhang, P., Luo, X., Shao, Z., Liang, G., Fu, J., & Song, H. (2025) · JCA advances. · doi:10.1016/j.jcadva.2025.100168 · Cited by 1
Multimodal flexible sensors for edge AI system
Nakamura, H., Seimiya, N., & Takei, K. (2025) · Applied Physics Express · doi:10.35848/1882-0786/ae1367 · Cited by 2
Wireless Bioelectronics for Bladder Function Monitoring
Lim, S., & Kim, J. (2025) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2025.34.5.513 · Cited by 1
Advancing biomedical implants through ultrasound-driven triboelectricity
Kang, D., Kim, S.-H., & Kim, S. (2025) · Device · doi:10.1016/j.device.2025.100901 · Cited by 1
Tang, X., Liu, P., Liu, X., & Qiu, L. (2025) · Ultrasonic Imaging · doi:10.1177/01617346251380791 · Cited by 1
An Annular CMUT Array and Acquisition Strategy for Continuous Monitoring
Escorcia, M. J. A., Gholampour, A., van Schaijk, R. T. F., de Wijs, W.-J., Immink, A. H. J., Henneken, V. A., Lopata, R. G. P., & Schwab, H. (2025) · Sensors · doi:10.3390/s25216637 · Cited by 1
Understanding the Transvalvular Gradient in Aortic Stenosis: A Multifaceted Perspective
Canna, G. L., Habjan, S., & Scarfò, I. S. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14227916 · Cited by 3
“Automated flow assessment can improve the accuracy of detecting dynamic flow changes during stress testing, including dobutamine and exercise echocardiography, thereby refining the diagnostic evaluation of AS [105,106].”
Flexible Ultrasound Imaging Probe With Sub-Millimeter Element Pitch on Glass Fabric Using Xurography
Tomita, N., Sato, S., Noda, T., Yamamoto, M., Azuma, T., Tomii, N., Sakuma, I., Itoh, T., & Takamatsu, S. (2025) · IEEE Electron Device Letters · doi:10.1109/led.2025.3631924 · Cited by 1
“In particular, flexible ultrasound probes that can deform with body movements are advantageous in minimizing user discomfort [5], [6], [7].”
Mega, S., FOSSATI, C., Segreti, A., Cricco, R., Lazarevic, Z., Carpenito, M., Coletti, F., Valeri, J., Lemme, E., Pigozzi, F., et al. (2025) · Applied Sciences · doi:10.3390/app152312490 · Cited by 1
Textile Radio-Frequency Active Devices and Systems: Wireless Communication and Energy Harvesting
Song, W., Chen, H., Kou, Z., Chen, Z., Li, J., Liu, T., Fan, X., & Lu, W. (2025) · Research · doi:10.34133/research.1101 · Cited by 6
Shang, C., Qi, H., Wang, Z., Meng, K., Liu, Z., Meng, Z., Yang, Y., Wang, J., & Jiang, S. (2026) · Advanced Science · doi:10.1002/advs.202516891 · Cited by 1
“For example, Hu et al. developed ultrasonic patches capable of continuous left-ventricle volume measurement and real-time monitoring of cardiac performance (Figure 4f ) [ 65 ].”
Self-citationWijewardhane, N., Jones, L. I., Martin, R. M., Winter, H. R., & Hassani, F. A. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202502059 · Cited by 2
“Innovations such as stretchable electronics [ 33 ], nanomaterial-based transducers [ 34, 35 ], thin ultrasound based imagers [ 36–38 ], and bio-inspired sensor architectures [ 39, 40 ] have improved signal acquisition and reliability.”
Wang, H., Guo, K., Wu, Y., Yang, A., Sun, C., Si, S., Chen, L., Li, P., Li, J., & Yang, J. (2026) · Nondestructive Testing And Evaluation · doi:10.1080/10589759.2026.2615143 · Cited by 1
Lin, S., Chen, K., Yang, J., Wen, J., & Kong, D. (2026) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2026.114027 · Cited by 1
Li, Y., Cao, J. M., Wu, Y., Wang, B., Zhang, Z., Peng, J., Zhang, Y., Chen, J., Chen, W., Li, X., et al. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117551 · Cited by 1
Peng, H., Chen, Z., Tan, X., Fan, X., Xu, L., Li, S., Chen, D., & Sun, F. (2026) · Expert Systems with Applications · doi:10.1016/j.eswa.2026.131777 · Cited by 1
Artificial intelligence in heart failure
Li, X., Liu, Y., Zhang, X., Yang, N., Xu, T. W., Cui, X. W., & Chen, G. (2026) · The Egyptian Heart Journal · doi:10.1186/s43044-026-00723-w · Cited by 2
“Recently, the University of California developed a wearable cardiac ultrasound device for continuous, real-time, and direct cardiac function assessment [102].”
Learning 3-D Ultrasound Segmentation under Extreme Label Deficiency
Qin, Z., Ban, Y., Zhang, H., Zhu, R., & Anthony, B. (2026) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.12.014 · Cited by 1
Super-resolution pulse-echo imaging via 3D-printed phase-type acoustic meta-lens
Qiu, J.-F., Li, Z.-L., Zeng, L., Huang, L.-X., Lin, Z., Wen, Y.-H., Chen, J.-R., Li, P.-Q., Zhu, X.-F., Li, F., et al. (2026) · Ultrasonics · doi:10.1016/j.ultras.2026.108055 · Cited by 1
Orchestrating the post‑silicon revolution of electronics through material-enabled intelligence
Wang, B., Li, X., Yu, L., & Lu, Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.175242 · Cited by 1
Next Generation Ultrasound Transducers: The Role of Passive Layers and Hydrogel Couplants
Albay, M. M., Toymuş, A. T., Yılgör, E., YILGÖR, I., & Beker, L. (2026) · Small Methods · doi:10.1002/smtd.202502325 · Cited by 2
Liquid metal/PDMS composites as high-impedance, low-attenuation, flexible acoustic matching layers
Yang, Z., Liu, X., Wang, J., Dong, X., Ma, Y., Jeong, J., & Li, Z. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.176329 · Cited by 1
Self-citationBuonocunto, M., Jung, A., Meier, S., & Heijman, J. (2026) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2026.2674735 · Cited by 1
“Noninvasive wearables, such as smartwatches [70,71] or wearable ultrasound devices [72] enable continuous monitoring of markers like heart rate, heart rate variability, and even multiple lead ECGs.”
Zhuang, Z., Han, R., Hou, Y., Zhang, Q., Yu, J., Li, N., Wang, G., Fu, J., Deng, Z., Song, H., et al. (2026) · Advanced Materials · doi:10.1002/adma.73482 · Cited by 4
Seamless Human–Computer Interaction Enabled by Wearable Biointerfaces and Intelligent Systems
Wei, H., Hua, J., Jiang, Y., Zhu, W., Cheng, W. M., Shi, Y., & Pan, L. (2026) · Biomimetics · doi:10.3390/biomimetics11060368 · Cited by 1
“They have demonstrated significant value in fields such as clinical medical assistance [7–9], sports and health monitoring [10,11] and immersive entertainment [12].”
He, S., Sun, Z., Chen, Q., Hong, R. L., Lü, J., Zhang, P., Zhang, L., & Hong, J. (2026) · Applied Sciences · doi:10.3390/app16126126 · Cited by 2
Photonic integrated chip for wearable physiological and biochemical sensing
Li, X., Li, H., Ding, M., Han, M., Liu, Y., Yang, L., Zhang, C. H. I., Zhang, L., Hernández-Ramírez, F., Cao, L., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140406 · Cited by 1
Metadata
- Authors
- Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., Li, C., Maus, T. M., Huang, B., Lu, C., Lin, M., Zhou, S., Lou, Z., Gu, Y., Chen, Y., Lei, Y., Wang, X., Wang, R., Yue, W., Yang, X., Bian, Y., Mu, J., Park, G., Xiang, S., Cai, S., Corey, P. W., Wang, J., & Xu, S.
- Affiliations
- University of California San Diego (US)
- University of California, Riverside (US)
- Yale University (US)
- Sharp Memorial Hospital (US)
- Corresponding author
- Xu, Sheng
- ORCID
- Hu, Hongjie
- Huang, Hao
- Li, Mohan
- Gao, Xiaoxiang
- Yin, Lu
- Qi, Ruixiang
- Wu, Ray S.
- Chen, Xiangjun
- Ma, Yuxiang
- Shi, Keren
- Li, Chenghai
- Maus, Timothy M.
- Huang, Brady
- Lu, Chengchangfeng
- Lin, Muyang
- Zhou, Sai
- Lou, Zhiyuan
- Gu, Yue
- Chen, Yimu
- Lei, Yusheng
- Wang, Xinyu
- Yang, Xinyi
- Bian, Yizhou
- Park, Geonho
- Cai, Shengqiang
- Wang, Joseph
- Xu, Sheng
- Venue
- Nature
- Published
- 2023-01-25
- Volume
- 613
- Issue
- 7945
- Pages
- 667-675
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC9876798
- OpenAlex
- W4317951947
- Cited by
- 644
- References
- 63
- Citations by year
- 2026: 148 · 2025: 216 · 2024: 181 · 2023: 99
- FWCI
- 50.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Institutes of Health (3r21eb027303-02s1, 1r21eb027303-01a1, 1r21eb025521-01, 1r01eb033464-01)
- University of California, San Diego
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303, R21 EB025521, 1 R01 EB03346401, R01 EB033464, 1R21EB027303-01A1, 1R21EB025521-01, 3R21EB027303-02S1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Keywords
- cardiac function monitoring, deep learning segmentation, left ventricular volume, stroke volume, cardiac output, ejection fraction, wearable device design
- MeSH terms
- Wearable Electronic Devices, Cardiac Output, Echocardiography, Equipment Design, Heart, Heart Ventricles, Humans, Skin, Stroke Volume
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.