A wearable cardiac ultrasound imager
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Continuous imaging of cardiac functions is highly desirable for the assessment of long-term cardiovascular health, detection of acute cardiac dysfunction and clinical management of critically ill or surgical patients 1–4 . However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness 5–11 , and existing wearable cardiac devices can only capture signals on the skin 12–16 . Here we report a wearable ultrasonic device for continuous, real-time and direct cardiac function assessment. We introduce innovations in device design and material fabrication that improve the mechanical coupling between the device and human skin, allowing the left ventricle to be examined from different views during motion. We also develop a deep learning model that automatically extracts the left ventricular volume from the continuous image recording, yielding waveforms of key cardiac performance indices such as stroke volume, cardiac output and ejection fraction. This technology enables dynamic wearable monitoring of cardiac performance with substantially improved accuracy in various environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures













Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Analyze ultrasound echoes to track muscle | morphological dynamics and infer joint | movement 214 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [116]
Experimental — accuracy not yet measuredIn the citing paper
“Based on this, dynamic changes in muscle strength can be analyzed 116,117 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [116]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Reinforcement Learning: A Survey
Kaelbling, L. P., Littman, M. L., & Moore, A. W. (1996) · Journal of Artificial Intelligence Research · doi:10.1613/jair.301 · Cited by 8,972
Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography
Schiller, N. B., Shah, P. M., Crawford, M., DeMaria, A., Devereux, R., Feigenbaum, H., Gutgesell, H., Reichek, N., Sahn, D., Schnittger, I., et al. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80014-8 · Cited by 8,121
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153 · cited 1×
“x N Δ = imaging width − 1 (3) pixel,lateral”
Background3D Printing of Free Standing Liquid Metal Microstructures
Ladd, C., So, J., Muth, J., & Dickey, M. D. (2013) · Advanced Materials · doi:10.1002/adma.201301400 · Cited by 926
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Self-citationGhorbanzadeh, O., Blaschke, T., Gholamnia, K., Meena, S. R., Tiede, D., & Aryal, J. (2019) · Remote Sensing · doi:10.3390/rs11020196 · Cited by 875
Research works printed but not linked: 2
- García-González, M. A., Argelagós-Palau, A., Fernández-Chimeno, M. & Ramos-Castro, J. in Computing in Cardiology 2013 461–464 (IEEE, 2014).
- Sung, F. et al. in Proc. 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition 1199–1208 (IEEE, 2018).
Cited by
Items 601–644 of 644
Jiang, Y., Liang, M., Xie, Y., Su, R., Wang, B., Wu, F., Bian, X., Tian, H., & You, R. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01354-6
“In contrast, fl exible pressure sensors, owing to their lightweight, bendability, and superior conformability, have rapidly emerged as a pivotal technological route for constructing novel intelligent sensing interfaces 7,8 .”
Ultrasound wrist imaging enables continuous and high-dimensional hand tracking
Jiao, F., Wang, C., & Dong, L. (2026) · Science China Materials · doi:10.1007/s40843-026-4270-8
“In parallel, the development of flexible or stretchable ultrasound transducer arrays and soft, conformal packaging could improve long-term comfort and mechanical compatibility with the skin [7].”
Corredoira, P. M. F., Kaski, J. C., Duncker, D., Dörr, M., Wilhelm, M., Tubaro, M., Schuuring, M. J., Mamas, M. A., Petersen, S. E., Vidal-Pérez, R., et al. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag074
Adhesion toughness of soft materials measured in peel and lap shear
Wang, Y., Jiang, Y., & Wang, Y. (2026) · Extreme Mechanics Letters · doi:10.1016/j.eml.2026.102506 · Cited by 1
Flexible ultrasound patches for cardiovascular function and disease monitoring
Zhou, Y., Xu, X., Zhang, Z., Wu, H., Yin, X., Chen, X., Wang, C., Kang, Y., Zhou, X., & Ge, M. (2026) · The Innovation Materials · doi:10.59717/j.xinn-mater.2026.100231
Self-citationBioinspired Permeable Soft Electronics for Advanced Healthcare Monitoring
Yuan, M., Zeng, Z., Zhao, J., Ji, J., Liu, J., Sun, Y., Lin, T., Dong, S., & Fang, Y. (2026) · Advanced Fiber Materials · doi:10.1007/s42765-026-00747-6 · Cited by 1
Human-inspired time-series health evaluation with an adaptive multimodal electronic skin
Xu, C., Zheng, H., Heng, W., Liu, R., MarionSims, J., Li, J., Jin, P., Tay, R. Y., Min, J., Wang, G., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeg5606 · Cited by 1
Wearable ultrasound: Design, development, and application in precision medicine
Dong, H., Liang, X., Liu, X., 邢长洋, & Yuan, L. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100149
Biomimetic Gradient Microstructures Enable Stable, High‐Sensitivity Pressure Sensing From Pa to MPa
Jin, B., Zhuang, R., Zhang, Z., Sun, B., Gao, W., & Pan, C. (2026) · Advanced Functional Materials · doi:10.1002/adfm.77497
Wearable Electronics for Precision Diagnosis Through Advanced Manufacturing and Integration
Gong, X., Zheng, Y., Ding, X., Gao, J., Cheng, B., Shao, X., Li, J., Jiang, L., Haick, H., & Yang, J. (2026) · Nano-Micro Letters · doi:10.1007/s40820-026-02311-8
Xia, L., Sheng, K., Zhang, Y., Xin, D., Liu, J., Lou, J., Xu, L., & Pan, Z. (2026) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2026.110166
Acoustofluidics for translational medicine
He, Y., Rufo, J., Yang, K., Chen, Y., Drinkwater, B. W., Zheng, H., Lee, L. P., & Huang, T. J. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00479-7 · Cited by 1
“…also employed during the postacquisition image-processing stage, in which an FCN-32 model automatically segmented left ventricular images and extracted left ventricular volume from continuous recordings, enabling downstream calculation of stroke volume, cardiac output and ejection fraction 132 .”
Self-citationSkin-Inspired Flexoelectret Touch Sensor for Self-Powered and Self-Calibrated Tactile Imaging
Ge, R., Yu, Q., Zhang, Y., Cai, Y., Liu, S., Liu, W., Zhang, J., & Qin, Y. (2026) · Research · doi:10.34133/research.1419
“This kind of self-powered sensing does not need the external power source but relies on the energy of applied stimuli, and has triggered plenty of new applications such as self-powered tactile imaging, self-powered cardiovascular electronics, and self-powered electronic tongue [ 2 , 21 , 22 ].”
Kang, J., Kim, D., Sung, Y., Cho Eun, L. E. E., Nam, S. Y., & Lim, H. G. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.6c01795
Wang, M. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7310424
Yuan, J., Wang, T., Li, Z., Li, J., Qin, S., Zhang, S., Li, Z., Zhao, Y., Yang, P., Luo, R., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01318-w
“…anomalies in biological tissues or structural defects in industrial components by the propagation characteristics of acoustic waves in a non-invasive and harmless manner, making them enduring and indispensable devices in clinical medical imaging and industrial non-destructive detection 1 – 3 .”
Self-citationZhang, Z., Yang, L., Wang, Q., Yin, C., Sun, X., Chen, Z., Huang, X., Zhong, X., Liu, Z., Luo, H., et al. (2026) · Chemical Engineering Journal · doi:10.2139/ssrn.7324377
Translating wearable ultrasound with system integration and enabling technologies
Kupsch, C., Leitner, C., Luca Benini, C., & Weik, D. (2026) · Nature Sensors · doi:10.1038/s44460-026-00118-z
Gao, J., Wang, Y., Huang, F., Guan, Z., Jiang, Y., Cheng, W., Shi, Y., & Pan, L. (2026) · Materials Today · doi:10.1016/j.mattod.2026.103493
A soft 64-channel wearable ultrasound patch system for dynamic deep-tissue imagingPreprint
Zhang, H., Hou, Y., Wang, J., Zhang, D., Lu, Y., Chen, C., Chen, D., Lu, H., Feng, L., Chen, H., et al. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7385568
Self-citationSmart wearable bioelectronics toward closed-loop cancer management
Li, Q., Lei, X., Tong, X., Han, S., Wang, X., Song, Y., & Wang, L. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.181580
Self-citationLi, X., Li, M., Song, H., Liu, X., Jia, F., Tang, Y., Wu, P., & Wen, Q. (2026) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2026.108063
“…[71]; (ii) distributed on-body architectures that shift part of the power and driver burden away from the skin-contact module during longer or higher-average-power exposure [72]; and (iii) externally powered or battery-free-at-the-patch approaches when local battery volume becomes limiting [73].”
Self-citationThe Exciting Future of Cardiovascular Imaging
Gräni, C., Bucciarelli‐Ducci, C., Dweck, M. R., & Zoghbi, W. A. (2026) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2026.07.015 · Cited by 2
Ultrathin wearable ultrasound patch with anti-matching for carotid artery monitoring
Yang, Y., Zhang, X., Li, Y., Li, H., Tan, Y., Li, C., Xu, L., & Ma, J. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119224
Self-citationFine-grained multi-level gesture recognition based on a stretchable multichannel ultrasonic device
Lin, X., Liu, H., Lin, K., Chen, J., Huang, Y., & Song, J. (2026) · Science Advances · doi:10.1126/sciadv.aef1101
Red-emitting chemosensor detects superoxide anion in models of myocardial hypertrophy
Guo, F., Liu, Y., Chen, Q., & Deng, Y.-S. (2026) · RSC Advances · doi:10.1039/d6ra00466k
“ECG o ff ers the advantages of convenience and low cost in diagnosing patients with myocardial hypertrophy, 7,8 yet it su ff ers from low speci city.”
Engineering magnetic soft materials for biomedical applications
Liu, X., Xia, N., Chan, K. F., Sung, J. J. �., Chiu, P. W. Y., Wang, L., & Zhang, L. (2026) · Nature Reviews Materials · doi:10.1038/s41578-026-00963-x
AI-enabled portable healthcare devices: From signal measurement to user-side digital doctors
Ren, H., & Shen, Y. (2026) · Biomedical Instrumentation · doi:10.1016/j.bmi.2026.100072
Li, D., Xu, M., Liang, S., Hou, C., Li, Z., & Yang, Y. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3736202
“…have focused on improving device performance by leveraging novel PMUT structural materials or new PMUT arrays [1], [3], [9], [10], [11], [12] or enhancing overall performance through the adoption of novel algorithms, data processing methods, or advanced AI technologies [2], [4], [5], [8].”
Tariq, A., Sohn, W., Lee, Y. J., & Kim, Y. (2026) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.126.324766
Recent Advances in Piezoelectric Ultrasound Sensors: A Compact Review on Key Applications
Yoon, Y., 김주희, 김주희, Min, B.-J., Choi, Y.-R., Kim, S.-B., Liu, X., Choi, S.-H., Yan, Y., & Song, H. (2026) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2026.35.5.469
He, M., Zhuang, X., & Cao, R. (2026) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-026-01162-1
“Three problems have organized the work: holding signal quality steady over hours and during body motion, reaching deeper tissue and more phenotypes, and packaging both into miniaturized, flexible, wireless hardware [36, 96 , 98 , 99 ].”
Zgool, T., Lebrat, L., Antico, M., Edwards, C., Roots, J., & Fontanarosa, D. (2026) · Research Square · doi:10.21203/rs.3.rs-10991367/v1
Photoacoustic Microscopy: Technological Advances, Biomedical Applications, and Future Perspectives
Zhang, X., Yin, H., Li, Z., Song, K., Liu, N., & Liu, K. (2026) · Journal of Biophotonics · doi:10.1002/jbio.70375
Wang, M., Zhao, Q., Lan, J., Xue, W., Wang, P., Guo, W., Zhang, Y., & 梁月琴 (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118670
Ultrasonic Sensors and Actuators for Cell/Tissue Culture in Biomedical Applications
Koda, S., & Kurashina, Y. (2026) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2026.p1353
Delaney, C. M., Bashatah, A., Aher, A., King, E. L., Taghizadeh, Z., Chitnis, P. V., & Sikdar, S. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.19.759949
“The imaging of the human carotid wall motion was motivated by the concept of using a worn ultrasound system for continuous monitoring of blood flow and blood pressure [26], [27], [28].”
Pettebone, M. E., Han, J., Forouzandehmehr, M., Chesla, O., Chua, C. J., Pozo, M. R., Heinson, Y. W., Liu, W., & Entcheva, E. G. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.19.760310
“Newer developments of miniaturized wearable ultrasound transducers suggest that such devices are a possibility[24, 25, 50, 51].”
She, Z., Shi, L., Xie, D., Jiang, F., Zhong, C., Cheng, Z., Shuning, J., Xie, H., Li, Y., & Zhou, J. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.183437
A Wearable Ultrasound Sensor for the Simultaneous Assessment of Hemodynamics and Blood Pressure
Li, X., Zhu, S., Wang, H., Zhou, Z., Wu, B., Li, Y., Zheng, C., Fu, Y., Tian, Y., Liu, T., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.6c02065
Zhang, L., Xiao, S., Wu, S., Xia, J., & Zhou, Q. (2026) · Photoacoustics · doi:10.1016/j.pacs.2026.100899
Robot-assisted ultrasound imaging towards embodied intelligence: a survey
Fang, Q., Chen, J., Tong, H., Liu, L., Liang, X., & Zhang, J. (2026) · Sensors and Actuators Reports · doi:10.1016/j.snr.2026.100534
Wearable Ultrasound in Cardiovascular Monitoring: Clinical Evidence and Translational Challenges
Han, X., Ma, X., Yu, F., Cai, L., Ren, P., Shi, P. X.-Q., & Wang, Z. (2026) · Advanced ultrasound in diagnosis and therapy · doi:10.26599/audt.2026.260039
Cheng, J., Wang, Y., Wang, X., Guo, R., Kong, M., Ren, A., Huang, P., Liu, S., Li, J., Shi, Y., et al. (2026) · eScience · doi:10.1016/j.esci.2026.100663
Self-citation
Metadata
- Authors
- Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., Li, C., Maus, T. M., Huang, B., Lu, C., Lin, M., Zhou, S., Lou, Z., Gu, Y., Chen, Y., Lei, Y., Wang, X., Wang, R., Yue, W., Yang, X., Bian, Y., Mu, J., Park, G., Xiang, S., Cai, S., Corey, P. W., Wang, J., & Xu, S.
- Affiliations
- University of California San Diego (US)
- University of California, Riverside (US)
- Yale University (US)
- Sharp Memorial Hospital (US)
- Corresponding author
- Xu, Sheng
- ORCID
- Hu, Hongjie
- Huang, Hao
- Li, Mohan
- Gao, Xiaoxiang
- Yin, Lu
- Qi, Ruixiang
- Wu, Ray S.
- Chen, Xiangjun
- Ma, Yuxiang
- Shi, Keren
- Li, Chenghai
- Maus, Timothy M.
- Huang, Brady
- Lu, Chengchangfeng
- Lin, Muyang
- Zhou, Sai
- Lou, Zhiyuan
- Gu, Yue
- Chen, Yimu
- Lei, Yusheng
- Wang, Xinyu
- Yang, Xinyi
- Bian, Yizhou
- Park, Geonho
- Cai, Shengqiang
- Wang, Joseph
- Xu, Sheng
- Venue
- Nature
- Published
- 2023-01-25
- Volume
- 613
- Issue
- 7945
- Pages
- 667-675
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC9876798
- OpenAlex
- W4317951947
- Semantic Scholar
- cbe8b122bd9033ff17962e7da465498e89d9d5cf
- Cited by
- 644
- References
- 63
- Citations by year
- 2026: 148 · 2025: 216 · 2024: 181 · 2023: 99
- FWCI
- 50.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Institutes of Health (3r21eb027303-02s1, 1r21eb027303-01a1, 1r21eb025521-01, 1r01eb033464-01)
- University of California, San Diego
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303, R21 EB025521, 1 R01 EB03346401, R01 EB033464, 1R21EB027303-01A1, 1R21EB025521-01, 3R21EB027303-02S1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Keywords
- cardiac function monitoring, deep learning segmentation, left ventricular volume, stroke volume, cardiac output, ejection fraction, wearable device design
- MeSH terms
- Wearable Electronic Devices, Cardiac Output, Echocardiography, Equipment Design, Heart, Heart Ventricles, Humans, Skin, Stroke Volume
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.