Ultra-fast proteomics with Scanning SWATH
Open accessThe DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
Accurate quantification of the proteome remains challenging for large sample series and longitudinal experiments. We report a data-independent acquisition method, Scanning SWATH, that accelerates mass spectrometric (MS) duty cycles, yielding quantitative proteomes in combination with short gradients and high-flow (800 µl min–1) chromatography. Exploiting a continuous movement of the precursor isolation window to assign precursor masses to tandem mass spectrometry (MS/MS) fragment traces, Scanning SWATH increases precursor identifications by ~70% compared to conventional data-independent acquisition (DIA) methods on 0.5–5-min chromatographic gradients. We demonstrate the application of ultra-fast proteomics in drug mode-of-action screening and plasma proteomics. Scanning SWATH proteomes capture the mode of action of fungistatic azoles and statins. Moreover, we confirm 43 and identify 11 new plasma proteome biomarkers of COVID-19 severity, advancing patient classification and biomarker discovery. Thus, our results demonstrate a substantial acceleration and increased depth in fast proteomic experiments that facilitate proteomic drug screens and clinical studies. Scanning SWATH increases the speed and selectivity of proteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
clusterProfiler: an R Package for Comparing Biological Themes Among Gene Clusters
Yu, G., Wang, L.-G., Han, Y., & He, Q.-Y. (2012) · OMICS: A Journal of Integrative Biology · doi:10.1089/omi.2011.0118 · Cited by 36,259
Complex heatmaps reveal patterns and correlations in multidimensional genomic data
Gu, Z., Eils, R., & Schlesner, M. (2016) · Bioinformatics · doi:10.1093/bioinformatics/btw313 · Cited by 10,034
Universal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
UniProt: a worldwide hub of protein knowledge
The UniProt Consortium (2019) · Nucleic Acids Research · doi:10.1093/nar/gky1049 · Cited by 7,698
Perez-Riverol, Y., Csordas, A., Bai, J., Bernal-Llinares, M., Hewapathirana, S., Kundu, D. J., Inuganti, A., Griss, J., Mayer, G., Eisenacher, M., et al. (2019) · Nucleic Acids Research · doi:10.1093/nar/gky1106 · Cited by 6,693
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180
DIA-NN: neural networks and interference correction enable deep proteome coverage in high throughput
Demichev, V., Messner, C. B., Vernardis, S. I., Lilley, K. S., & Ralser, M. (2020) · Nature Methods · doi:10.1038/s41592-019-0638-x · Cited by 3,343
Self-citationGillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Self-citationA comprehensive map of molecular drug targets
Santos, R., Ursu, O., Gaulton, A., Bento, A. P., Donadi, R. S., Bologa, C. G., Karlsson, A., Al-Lazikani, B., Hersey, A., Oprea, T. I., et al. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.230 · Cited by 2,427
Cited by
Ultra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
“This is consistent with the reports of DIA-NN being used for sample-limited analyses and very short gradients (Messner et al , 2020, 2021; preprint: Demichev et al , 2021; Fig EV7).”
dia-PASEF data analysis using FragPipe and DIA-NN for deep proteomics of low sample amounts
Demichev, V., Szyrwiel, L., Yu, F., Teo, G. C., Rosenberger, G., Niewienda, A., Ludwig, D., Decker, J., Kaspar-Schoenefeld, S., Lilley, K. S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31492-0 · Cited by 441
Self-citationGuzman, U. H., Martinez-Val, A., Ye, Z., Damoc, E., Arrey, T. N., Pashkova, A., Renuse, S., Denisov, E., Petzoldt, J., Peterson, A. C., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-02099-7 · Cited by 346
MSBooster: improving peptide identification rates using deep learning-based features
Yang, K. L., Yu, F., Teo, G. C., Li, K., Demichev, V., Ralser, M., & Nesvizhskii, A. I. (2023) · Nature Communications · doi:10.1038/s41467-023-40129-9 · Cited by 221
“, 10 Da) window of m/z values (data independent acquisition, DIA) [4] or in a continuous quadrupole scan of a particular window size [5] are selected for simultaneous fragmentation.”
Self-citationTrapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics
Meier, F., Park, M. A., & Mann, M. (2021) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2021.100138 · Cited by 183
Kitata, R. B., Yang, J., & Chen, Y. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21781 · Cited by 165
Natural proteome diversity links aneuploidy tolerance to protein turnover
Muenzner, J., Trébulle, P., Agostini, F., Zauber, H., Messner, C. B., Steger, M., Kilian, C., Lau, K., Barthel, N., Lehmann, A., et al. (2024) · Nature · doi:10.1038/s41586-024-07442-9 · Cited by 81
Self-citationSkowronek, P., Wallmann, G., Wahle, M., Willems, S., & Mann, M. (2025) · Nature Protocols · doi:10.1038/s41596-024-01104-w · Cited by 43
Teyssonnière, E. M., Trébulle, P., Muenzner, J., Loegler, V., Ludwig, D., Amari, F., Mülleder, M., Friedrich, A., Hou, J., Ralser, M., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2319211121 · Cited by 40
“For the acquisition of this dataset, we used a proteomic method that allows for an even higher throughput, using analytical flowrate chromatography and Scanning - SWATH MS with a 3 min gradient (46).”
MethodInfluentialSelf-citationAmino acid sequence encodes protein abundance shaped by protein stability at reduced synthesis cost
(2024) · doi:10.1002/pro.5239 · Cited by 12
Metadata
- Authors
- Messner, C. B., Demichev, V., Bloomfield, N., Yu, J. S. L., White, M., Kreidl, M., Egger, A.-S., Freiwald, A., Ivosev, G., Wasim, F., Zelezniak, A., Jürgens, L., Suttorp, N., Sander, L. E., Kurth, F., Lilley, K. S., Mülleder, M., Tate, S., & Ralser, M.
- Venue
- Nature Biotechnology
- Published
- 2021-03-25
- Volume
- 39
- Issue
- 7
- Pages
- 846-854
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W3138817412
- Cited by
- 308
- References
- 83
- FWCI
- 17.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.