Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Trapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics

Open access
Meier, Florian, Park, Melvin A., Mann, Matthias · 2021 · Molecular & Cellular Proteomics

Abstract

Recent advances in efficiency and ease of implementation have rekindled interest in ion mobility spectrometry, a technique that separates gas phase ions by their size and shape and that can be hybridized with conventional LC and MS. Here, we review the recent development of trapped ion mobility spectrometry (TIMS) coupled to TOF mass analysis. In particular, the parallel accumulation-serial fragmentation (PASEF) operation mode offers unique advantages in terms of sequencing speed and sensitivity. Its defining feature is that it synchronizes the release of ions from the TIMS device with the downstream selection of precursors for fragmentation in a TIMS quadrupole TOF configuration. As ions are compressed into narrow ion mobility peaks, the number of peptide fragment ion spectra obtained in data-dependent or targeted analyses can be increased by an order of magnitude without compromising sensitivity. Taking advantage of the correlation between ion mobility and mass, the PASEF principle also multiplies the efficiency of data-independent acquisition. This makes the technology well suited for rapid proteome profiling, an increasingly important attribute in clinical proteomics, as well as for ultrasensitive measurements down to single cells. The speed and accuracy of TIMS and PASEF also enable precise measurements of collisional cross section values at the scale of more than a million data points and the development of neural networks capable of predicting them based only on peptide sequences. Peptide collisional cross section values can differ for isobaric sequences or positional isomers of post-translational modifications. This additional information may be leveraged in real time to direct data acquisition or in postprocessing to increase confidence in peptide identifications. These developments make TIMS quadrupole TOF PASEF a powerful and expandable platform for proteomics and beyond.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.mcpro.2021.100138

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Research works printed but not linked: 101

  1. Adhikari, 2020, A high-stringency blueprint of the human proteome, Nat. Commun., 11, 5301, 10.1038/s41467-020-19045-9 · DOI · Paper page
  2. Müller, 2020, The proteome landscape of the kingdoms of life, Nature, 582, 592, 10.1038/s41586-020-2402-x · DOI · Paper page
  3. Shishkova, 2016, Now, more than ever, proteomics needs better chromatography, Cell Syst., 3, 321, 10.1016/j.cels.2016.10.007 · DOI
  4. Bekker-Jensen, 2017, An optimized shotgun strategy for the rapid generation of comprehensive human proteomes, Cell Syst., 4, 587, 10.1016/j.cels.2017.05.009 · DOI · Paper page
  5. Meier, 2018, BoxCar acquisition method enables single-shot proteomics at a depth of 10,000 proteins in 100 minutes, Nat. Methods, 15, 440, 10.1038/s41592-018-0003-5 · DOI · Paper page
  6. Muntel, 2019, Surpassing 10 000 identified and quantified proteins in a single run by optimizing current LC-MS instrumentation and data analysis strategy, Mol. Omics, 15, 348, 10.1039/C9MO00082H · DOI · Paper page
  7. Kanu, 2008, Ion mobility-mass spectrometry, J. Mass Spectrom., 43, 1, 10.1002/jms.1383 · DOI · Paper page
  8. May, 2015, Ion mobility-mass spectrometry: Time-dispersive instrumentation, Anal. Chem., 87, 1422, 10.1021/ac504720m · DOI · Paper page
  9. Dodds, 2019, Ion mobility spectrometry: Fundamental concepts, instrumentation, applications, and the road ahead, J. Am. Soc. Mass Spectrom., 30, 2185, 10.1007/s13361-019-02288-2 · DOI · Paper page
  10. Giles, 2004, Applications of a travelling wave-based radio-frequency-only stacked ring ion guide, Rapid Commun. Mass Spectrom., 18, 2401, 10.1002/rcm.1641 · DOI · Paper page
  11. Shvartsburg, 2008, Fundamentals of traveling wave ion mobility spectrometry, Anal. Chem., 80, 9689, 10.1021/ac8016295 · DOI · Paper page
  12. Buryakov, 1993, A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field, Int. J. Mass Spectrom. Ion Process., 128, 143, 10.1016/0168-1176(93)87062-W · DOI · Paper page
  13. Guevremont, 2004, High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry, J. Chromatogr. A, 1058, 3, 10.1016/S0021-9673(04)01478-5 · doi:10.1016/s0021-9673(04)01478-5 · Paper page
  14. Venne, 2005, Improvement in peptide detection for proteomics analyses using nanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry, Anal. Chem., 77, 2176, 10.1021/ac048410j · DOI
  15. Canterbury, 2008, Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics, Anal. Chem., 80, 6888, 10.1021/ac8004988 · DOI
  16. Saba, 2009, Enhanced sensitivity in proteomics experiments using FAIMS coupled with a hybrid linear ion trap/orbitrap mass spectrometer, J. Proteome Res., 8, 3355, 10.1021/pr801106a · DOI
  17. Baker, 2010, An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies, J. Proteome Res., 9, 997, 10.1021/pr900888b · DOI
  18. Distler, 2014, Drift time-specific collision energies enable deep-coverage data-independent acquisition proteomics, Nat. Methods, 11, 167, 10.1038/nmeth.2767 · DOI · Paper page
  19. Helm, 2014, Ion mobility tandem mass spectrometry enhances performance of bottom-up proteomics, Mol. Cell. Proteomics, 13, 3709, 10.1074/mcp.M114.041038 · DOI
  20. Distler, 2014, Biomedical applications of ion mobility-enhanced data-independent acquisition-based label-free quantitative proteomics, Expert Rev. Proteomics, 11, 675, 10.1586/14789450.2014.971114 · DOI
  21. Pfammatter, 2018, A novel differential ion mobility device expands the depth of proteome coverage and the sensitivity of multiplex proteomic measurements, Mol. Cell. Proteomics, 17, 2051, 10.1074/mcp.TIR118.000862 · DOI
  22. Hebert, 2018, Comprehensive single-shot proteomics with FAIMS on a hybrid orbitrap mass spectrometer, Anal. Chem., 90, 9529, 10.1021/acs.analchem.8b02233 · DOI · Paper page
  23. Meier, 2018, Online parallel accumulation–serial fragmentation (PASEF) with a novel trapped ion mobility mass spectrometer, Mol. Cell. Proteomics, 17, 2534, 10.1074/mcp.TIR118.000900 · DOI · Paper page
  24. Bekker-Jensen, 2020, A compact quadrupole-orbitrap mass spectrometer with FAIMS interface improves proteome coverage in short LC gradients, Mol. Cell. Proteomics, 19, 716, 10.1074/mcp.TIR119.001906 · DOI · Paper page
  25. Meyer, 2020, Quantitative shotgun proteome analysis by direct infusion, Nat. Methods, 17, 1222, 10.1038/s41592-020-00999-z · DOI
  26. Fernandez-Lima, 2011, Gas-phase separation using a trapped ion mobility spectrometer, Int. J. Ion Mobil. Spectrom., 14, 93, 10.1007/s12127-011-0067-8 · DOI · Paper page
  27. Fernandez-Lima, 2011, Note: Integration of trapped ion mobility spectrometry with mass spectrometry, Rev. Sci. Instrum., 82, 126106, 10.1063/1.3665933 · DOI · Paper page
  28. Meier, 2015, Parallel accumulation–serial fragmentation (PASEF): Multiplying sequencing speed and sensitivity by synchronized scans in a trapped ion mobility device, J. Proteome Res., 14, 5378, 10.1021/acs.jproteome.5b00932 · DOI · Paper page
  29. Ridgeway, 2018, Trapped ion mobility spectrometry: A short review, Int. J. Mass Spectrom., 425, 22, 10.1016/j.ijms.2018.01.006 · DOI · Paper page
  30. Silveira, 2017, Parallel accumulation for 100% duty cycle trapped ion mobility-mass spectrometry, Int. J. Mass Spectrom., 413, 168, 10.1016/j.ijms.2016.03.004 · DOI
  31. Beck, 2015, The impact II, a very high-resolution quadrupole time-of-flight instrument (QTOF) for deep shotgun proteomics, Mol. Cell. Proteomics, 14, 2014, 10.1074/mcp.M114.047407 · DOI · Paper page
  32. Lesur, 2021, Highly multiplexed targeted proteomics acquisition on a TIMS-QTOF, Anal. Chem., 93, 1383, 10.1021/acs.analchem.0c03180 · DOI
  33. Meier, 2020, diaPASEF: Parallel accumulation–serial fragmentation combined with data-independent acquisition, Nat. Methods, 17, 1229, 10.1038/s41592-020-00998-0 · DOI · Paper page
  34. Michelmann, 2014, Fundamentals of trapped ion mobility spectrometry, J. Am. Soc. Mass Spectrom., 26, 14, 10.1007/s13361-014-0999-4 · DOI · Paper page
  35. Silveira, 2016, Fundamentals of trapped ion mobility spectrometry part II: Fluid dynamics, J. Am. Soc. Mass Spectrom., 27, 585, 10.1007/s13361-015-1310-z · DOI
  36. Bleiholder, 2016, Towards measuring ion mobilities in non-stationary gases and non-uniform and dynamic electric fields (I). Transport equation, Int. J. Mass Spectrom., 399-400, 1, 10.1016/j.ijms.2016.01.003 · DOI
  37. Silveira, 2016, Altering the mobility-time continuum: Nonlinear scan functions for targeted high resolution trapped ion mobility-mass spectrometry, Int. J. Ion Mobil. Spectrom., 19, 87, 10.1007/s12127-016-0196-1 · DOI
  38. Benigni, 2018, Increasing analytical separation and duty cycle with nonlinear analytical mobility scan functions in TIMS-FT-ICR MS, Anal. Chem., 90, 2446, 10.1021/acs.analchem.7b04053 · DOI
  39. Silveira, 2014, High resolution trapped ion mobility spectrometery of peptides, Anal. Chem., 86, 5624, 10.1021/ac501261h · DOI · Paper page
  40. Hernandez, 2014, Ion dynamics in a trapped ion mobility spectrometer, Analyst, 139, 1913, 10.1039/C3AN02174B · DOI · Paper page
  41. Ridgeway, 2015, Microheterogeneity within conformational states of ubiquitin revealed by high resolution trapped ion mobility spectrometry, Analyst, 140, 6964, 10.1039/C5AN00841G · DOI
  42. Adams, 2016, Isomer separation of polybrominated diphenyl ether metabolites using nanoESI-TIMS-MS, Int. J. Ion Mobil. Spectrom., 19, 69, 10.1007/s12127-016-0198-z · doi:10.1007/s12127-016-0198-z
  43. Liu, 2018, Tandem trapped ion mobility spectrometry, Analyst, 143, 2249, 10.1039/C7AN02054F · DOI
  44. Ridgeway, 2016, Gated trapped ion mobility spectrometry coupled to Fourier transform ion cyclotron resonance mass spectrometry, Int. J. Ion Mobil. Spectrom., 19, 77, 10.1007/s12127-016-0197-0 · DOI
  45. Liu, 2016, On the structural denaturation of biological analytes in trapped ion mobility spectrometry – mass spectrometry, Analyst, 141, 3722, 10.1039/C5AN02399H · DOI
  46. Bleiholder, 2019, Structure relaxation approximation (SRA) for elucidation of protein structures from ion mobility measurements, J. Phys. Chem. B, 123, 2756, 10.1021/acs.jpcb.8b11818 · DOI
  47. Molano-Arevalo, 2017, Characterization of intramolecular interactions of cytochrome C using hydrogen–deuterium exchange-trapped ion mobility spectrometry–mass spectrometry and molecular dynamics, Anal. Chem., 89, 8757, 10.1021/acs.analchem.7b00844 · DOI
  48. Fantin, 2019, Collision induced unfolding classifies ligands bound to the integral membrane translocator protein, Anal. Chem., 91, 15469, 10.1021/acs.analchem.9b03208 · DOI
  49. Naylor, 2020, Evaluation of trapped ion mobility spectrometry source conditions using benzylammonium thermometer ions, J. Am. Soc. Mass Spectrom., 31, 1593, 10.1021/jasms.0c00151 · DOI
  50. Morsa, 2020, Effective temperature and structural rearrangement in trapped ion mobility spectrometry, Anal. Chem., 92, 4573, 10.1021/acs.analchem.9b05850 · DOI
  51. Yu, 2020, Fast quantitative analysis of timsTOF PASEF data with MSFragger and IonQuant, Mol. Cell. Proteomics, 19, 1575, 10.1074/mcp.TIR120.002048 · DOI · Paper page
  52. Tolmachev, 2004, Collisional activation of ions in RF ion traps and ion guides: The effective ion temperature treatment, J. Am. Soc. Mass Spectrom., 15, 1616, 10.1016/j.jasms.2004.07.014 · doi:10.1016/j.jasms.2004.07.014
  53. Bleiholder, 2020, Comment on effective temperature and structural rearrangement in trapped ion mobility spectrometry: TIMS enables native mass spectrometry applications, Anal. Chem., 10.1021/acs.analchem.0c02052 · doi:10.1021/acs.analchem.0c02052
  54. Panczyk, 2021, Surface-induced dissociation of protein complexes selected by trapped ion mobility spectrometry, Anal. Chem., 93, 5513, 10.1021/acs.analchem.0c05373 · DOI
  55. Larson, 2021, High-throughput multi-attribute analysis of antibody-drug conjugates enabled by trapped ion mobility spectrometry and top-down mass spectrometry, Anal. Chem., 93, 10013, 10.1021/acs.analchem.1c00150 · DOI
  56. Borotto, 2021, Fragmentation and mobility separation of peptide and protein ions in a trapped-ion mobility device, Anal. Chem., 93, 9959, 10.1021/acs.analchem.1c01188 · DOI
  57. Ogata, 2020, Extending the separation space with trapped ion mobility spectrometry improves the accuracy of isobaric tag-based quantitation in proteomic LC/MS/MS, Anal. Chem., 92, 8037, 10.1021/acs.analchem.0c01695 · DOI
  58. Vasilopoulou, 2020, Trapped ion mobility spectrometry and PASEF enable in-depth lipidomics from minimal sample amounts, Nat. Commun., 11, 331, 10.1038/s41467-019-14044-x · DOI · Paper page
  59. Andrews, 2011, Performance characteristics of a new hybrid quadrupole time-of-flight tandem mass spectrometer (TripleTOF 5600), Anal. Chem., 83, 5442, 10.1021/ac200812d · DOI · Paper page
  60. Kelstrup, 2012, Optimized fast and sensitive acquisition methods for shotgun proteomics on a quadrupole orbitrap mass spectrometer, J. Proteome Res., 11, 3487, 10.1021/pr3000249 · DOI · Paper page
  61. Steigenberger, 2020, Benefits of collisional cross section assisted precursor selection (caps-PASEF) for cross-linking mass spectrometry, Mol. Cell. Proteomics, 19, 1677, 10.1074/mcp.RA120.002094 · DOI
  62. Bailey, 2012, Instant spectral assignment for advanced decision tree-driven mass spectrometry, Proc. Natl. Acad. Sci. U. S. A., 109, 8411, 10.1073/pnas.1205292109 · DOI
  63. Wichmann, 2019, MaxQuant.Live enables global targeting of more than 25,000 peptides, Mol. Cell. Proteomics, 18, 982, 10.1074/mcp.TIR118.001131 · DOI
  64. Schweppe, 2020, Full-featured, real-time database searching platform enables fast and accurate multiplexed quantitative proteomics, J. Proteome Res., 19, 2026, 10.1021/acs.jproteome.9b00860 · DOI · Paper page
  65. Moseley, 2018, Scanning quadrupole data-independent acquisition, part A: Qualitative and quantitative characterization, J. Proteome Res., 17, 770, 10.1021/acs.jproteome.7b00464 · DOI
  66. Juvvadi, 2018, Scanning quadrupole data-independent acquisition, part B: Application to the analysis of the calcineurin-interacting proteins during treatment of Aspergillus fumigatus with azole and echinocandin antifungal drugs, J. Proteome Res., 17, 780, 10.1021/acs.jproteome.7b00499 · DOI
  67. Messner, 2021, Ultra-fast proteomics with scanning SWATH, Nat. Biotechnol., 39, 846, 10.1038/s41587-021-00860-4 · DOI · Paper page
  68. Amodei, 2019, Improving precursor selectivity in data-independent acquisition using overlapping windows, J. Am. Soc. Mass Spectrom., 30, 669, 10.1007/s13361-018-2122-8 · DOI
  69. Prianichnikov, 2020, MaxQuant software for ion mobility enhanced shotgun proteomics, Mol. Cell. Proteomics, 19, 1058, 10.1074/mcp.TIR119.001720 · DOI · Paper page
  70. Kong, 2017, MSFragger: Ultrafast and comprehensive peptide identification in mass spectrometry–based proteomics, Nat. Methods, 14, 513, 10.1038/nmeth.4256 · DOI · Paper page
  71. Yu, 2021, IonQuant enables accurate and sensitive label-free quantification with FDR-controlled match-between-runs, Mol. Cell. Proteomics, 20, 100077, 10.1016/j.mcpro.2021.100077 · DOI · Paper page
  72. Zhang, 2012, PEAKS DB: De novo sequencing assisted database search for sensitive and accurate peptide identification, Mol. Cell. Proteomics, 11, 10.1074/mcp.M111.010587 · DOI · Paper page
  73. Willems, 2021, AlphaTims: Indexing trapped ion mobility spectrometry – time of flight data for fast and easy accession and visualization, bioRxiv
  74. Łącki, 2021, OpenTIMS, TimsPy, and TimsR: Open and easy access to timsTOF raw data, J. Proteome Res., 20, 2122, 10.1021/acs.jproteome.0c00962 · doi:10.1021/acs.jproteome.0c00962
  75. Strauss, 2021, AlphaPept, a modern and open framework for MS-based proteomics, bioRxiv
  76. Pino, 2020, The Skyline ecosystem: Informatics for quantitative mass spectrometry proteomics, Mass Spectrom. Rev., 39, 229, 10.1002/mas.21540 · DOI · Paper page
  77. Röst, 2014, OpenSWATH enables automated, targeted analysis of data-independent acquisition MS data, Nat. Biotechnol., 32, 219, 10.1038/nbt.2841 · DOI · Paper page
  78. Demichev, 2020, DIA-NN: Neural networks and interference correction enable deep proteome coverage in high throughput, Nat. Methods, 17, 41, 10.1038/s41592-019-0638-x · DOI · Paper page
  79. Demichev, 2021, High sensitivity dia-PASEF proteomics with DIA-NN and FragPipe, bioRxiv
  80. Sinitcyn, 2021, MaxDIA enables library-based and library-free data-independent acquisition proteomics, Nat. Biotechnol., 10.1038/s41587-021-00968-7 · DOI · Paper page
  81. Meier, 2021, Deep learning the collisional cross sections of the peptide universe from a million experimental values, Nat. Commun., 12, 1185, 10.1038/s41467-021-21352-8 · DOI
  82. Revercomb, 1975, Theory of plasma chromatography/gaseous electrophoresis. Review, Anal. Chem., 47, 970, 10.1021/ac60357a043 · DOI · Paper page
  83. Chai, 2018, A transferable, sample-independent calibration procedure for trapped ion mobility spectrometry (TIMS), Anal. Chem., 90, 9040, 10.1021/acs.analchem.8b01326 · DOI
  84. Chang, 2021, Sequence-specific model for predicting peptide collision cross section values in proteomic ion mobility spectrometry, J. Proteome Res., 20, 3600, 10.1021/acs.jproteome.1c00185 · DOI
  85. Counterman, 2002, Cis−trans signatures of proline-containing tryptic peptides in the gas phase, Anal. Chem., 74, 1946, 10.1021/ac011083k · doi:10.1021/ac011083k
  86. Pierson, 2011, Number of solution states of bradykinin from ion mobility and mass spectrometry measurements, J. Am. Chem. Soc., 133, 13810, 10.1021/ja203895j · DOI
  87. Bache, 2018, A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics, Mol. Cell. Proteomics, 17, 2284, 10.1074/mcp.TIR118.000853 · DOI · Paper page
  88. Bian, 2020, Robust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC–MS/MS, Nat. Commun., 11, 157, 10.1038/s41467-019-13973-x · DOI · Paper page
  89. Zaro, 2020, Proteomic analysis of young and old mouse hematopoietic stem cells and their progenitors reveals post-transcriptional regulation in stem cells, Elife, 9, 10.7554/eLife.62210 · DOI
  90. Fu, 2020, Glucose-dependent partitioning of arginine to the urea cycle protects β-cells from inflammation, Nat. Metab., 2, 432, 10.1038/s42255-020-0199-4 · DOI
  91. Wu, 2020, Transcriptional and proteomic insights into the host response in fatal COVID-19 cases, Proc. Natl. Acad. Sci. U. S. A., 117, 28336, 10.1073/pnas.2018030117 · DOI · Paper page
  92. Geyer, 2021, High-resolution serum proteome trajectories in COVID-19 reveal patient-specific seroconversion, EMBO Mol. Med., 13, 10.15252/emmm.202114167 · DOI
  93. Tian, 2020, Immune suppression in the early stage of COVID-19 disease, Nat. Commun., 11, 5859, 10.1038/s41467-020-19706-9 · DOI · Paper page
  94. Jeanne Dit Fouque, 2021, Trapped ion mobility spectrometry of native macromolecular assemblies, Anal. Chem., 93, 2933, 10.1021/acs.analchem.0c04556 · DOI
  95. Alme, 2020, The kinase Isr1 negatively regulates hexosamine biosynthesis in S. cerevisiae, PLoS Genet., 16, 10.1371/journal.pgen.1008840 · DOI
  96. Glover, 2016, Examining the influence of phosphorylation on peptide ion structure by ion mobility spectrometry-mass spectrometry, J. Am. Soc. Mass Spectrom., 27, 786, 10.1007/s13361-016-1343-y · DOI
  97. Ogata, 2020, Effect of phosphorylation on the collision cross sections of peptide ions in ion mobility spectrometry, bioRxiv
  98. Ihling, 2021, Cross-linking/mass spectrometry combined with ion mobility on a timsTOF Pro instrument for structural proteomics, Anal. Chem., 93, 11442, 10.1021/acs.analchem.1c01317 · DOI
  99. Wen, 2020, Deep learning in proteomics, Proteomics, 20, 1900335, 10.1002/pmic.201900335 · DOI
  100. Tsugawa, 2020, A lipidome atlas in MS-DIAL 4, Nat. Biotechnol., 38, 1159, 10.1038/s41587-020-0531-2 · DOI · Paper page
  101. Nothias, 2020, Feature-based molecular networking in the GNPS analysis environment, Nat. Methods, 17, 905, 10.1038/s41592-020-0933-6 · DOI · Paper page

Cited by

See all 183

Metadata

Authors
Meier, F., Park, M. A., & Mann, M.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2021
Volume
20
Pages
100138
ISSN
1535-9476 (ISSN-L)
OpenAlex
W3195015580
Cited by
183
References
12
FWCI
9.06
Type
journal article
Language
en
Open access
gold
Licence
Funders
  • Max-Planck-Gesellschaft
  • German Research Foundation (MA 1764/2-1)
  • Bundesministerium für Bildung und Forschung

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics. https://app.cochat.ai/papers/10.1016/j.mcpro.2021.100138
The paper
Meier, F., Park, M. A., & Mann, M. (2021). Trapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics. Molecular & Cellular Proteomics. https://doi.org/10.1016/j.mcpro.2021.100138

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.