Increasing the throughput of sensitive proteomics by plexDIA
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Proteomics of small sample sizes using data-independent acquisition methods achieves higher throughput with multiplexing. Current mass spectrometry methods enable high-throughput proteomics of large sample amounts, but proteomics of low sample amounts remains limited in depth and throughput. To increase the throughput of sensitive proteomics, we developed an experimental and computational framework, called plexDIA, for simultaneously multiplexing the analysis of peptides and samples. Multiplexed analysis with plexDIA increases throughput multiplicatively with the number of labels without reducing proteome coverage or quantitative accuracy. By using three-plex non-isobaric mass tags, plexDIA enables quantification of threefold more protein ratios among nanogram-level samples. Using 1-hour active gradients, plexDIA quantified ~8,000 proteins in each sample of labeled three-plex sets and increased data completeness, reducing missing data more than twofold across samples. Applied to single human cells, plexDIA quantified ~1,000 proteins per cell and achieved 98% data completeness within a plexDIA set while using ~5 minutes of active chromatography per cell. These results establish a general framework for increasing the throughput of sensitive and quantitative protein analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180
DIA-NN: neural networks and interference correction enable deep proteome coverage in high throughput
Demichev, V., Messner, C. B., Vernardis, S. I., Lilley, K. S., & Ralser, M. (2020) · Nature Methods · doi:10.1038/s41592-019-0638-x · Cited by 3,343
Self-citationGillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Multiplex peptide stable isotope dimethyl labeling for quantitative proteomics
Boersema, P. J., Raijmakers, R., Lemeer, S., Mohammed, S., & Heck, A. J. R. (2009) · Nature Protocols · doi:10.1038/nprot.2009.21 · Cited by 1,357 · cited 2×
“Chemical labeling is often used with data-dependent acquisition (DDA) to increase through-put and control for shared artifacts, such as disturbances in peptide separation and ionization 10–12 .”
MethodBudnik, B., Levy, E., Harmange, G., & Slavov, N. (2018) · Genome Biology · doi:10.1186/s13059-018-1547-5 · Cited by 832
Self-citationAutomated approach for quantitative analysis of complex peptide mixtures from tandem mass spectra
Venable, J. D., Dong, M.-Q., Wohlschlegel, J., Dillin, A., & Yates, J. R. (2004) · Nature Methods · doi:10.1038/nmeth705 · Cited by 794 · cited 1×
“…to further increase the throughput of sensitive DIA by multiplexing samples labeled with nonisobaric isotopologous mass tags, capitalizing on the fact that increasing the number of precursor ions does not increase the time needed to analyze them via tandem DIA-MS, in contrast to DDA-MS 13,19 .”
The GOA database: Gene Ontology annotation updates for 2015
Huntley, R. P., Sawford, T., Mutowo-Meullenet, P., Shypitsyna, A., Bonilla, C., Martin, M. J., & O'Donovan, C. (2015) · Nucleic Acids Research · doi:10.1093/nar/gku1113 · Cited by 612
Isobaric Labeling-Based Relative Quantification in Shotgun Proteomics
Rauniyar, N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500880b · Cited by 596
Ultra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
Single-cell proteomic and transcriptomic analysis of macrophage heterogeneity using SCoPE2
Specht, H., Emmott, E., Petelski, A. A., Huffman, R. G., Perlman, D. H., Serra, M., Kharchenko, P., Koller, A., & Slavov, N. (2021) · Genome Biology · doi:10.1186/s13059-021-02267-5 · Cited by 493
Self-citationAn Optimized Shotgun Strategy for the Rapid Generation of Comprehensive Human Proteomes
Bekker-Jensen, D. B., Kelstrup, C. D., Batth, T. S., Larsen, S. C., Haldrup, C., Bramsen, J. B., Sørensen, K. D., Høyer, S., Ørntoft, T. F., Andersen, C. L., et al. (2017) · Cell Systems · doi:10.1016/j.cels.2017.05.009 · Cited by 490
Li, J., Van Vranken, J. G., Pontano Vaites, L., Schweppe, D. K., Huttlin, E. L., Etienne, C., Nandhikonda, P., Viner, R., Robitaille, A. M., Thompson, A. H., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-0781-4 · Cited by 449
dia-PASEF data analysis using FragPipe and DIA-NN for deep proteomics of low sample amounts
Demichev, V., Szyrwiel, L., Yu, F., Teo, G. C., Rosenberger, G., Niewienda, A., Ludwig, D., Decker, J., Kaspar-Schoenefeld, S., Lilley, K. S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31492-0 · Cited by 441
Self-citationA multicenter study benchmarks software tools for label-free proteome quantification
Navarro, P., Kuharev, J., Gillet, L. C., Bernhardt, O. M., MacLean, B., Röst, H. L., Tate, S. A., Tsou, C.-C., Reiter, L., Distler, U., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3685 · Cited by 346
Gas-phase separation using a trapped ion mobility spectrometer
Fernandez-Lima, F., Kaplan, D. A., Suetering, J., & Park, M. A. (2011) · International Journal for Ion Mobility Spectrometry · doi:10.1007/s12127-011-0067-8 · Cited by 315
Quantitative Mass Spectrometry Identifies Insulin Signaling Targets in C. elegans
Dong, M.-Q., Venable, J. D., Au, N., Xu, T., Park, S. K., Cociorva, D., Johnson, J. R., Dillin, A., & Yates, J. R. (2007) · Science · doi:10.1126/science.1139952 · Cited by 312
Ultra-fast proteomics with Scanning SWATH
Messner, C. B., Demichev, V., Bloomfield, N., Yu, J. S. L., White, M., Kreidl, M., Egger, A.-S., Freiwald, A., Ivosev, G., Wasim, F., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00860-4 · Cited by 308 · cited 1×
“Mass-spectrometry (MS) methods can achieve deep proteome coverage 1,2 , low missing data 3 , high throughput 4,5 , and high sensitivity 6 .”
BackgroundSelf-citationTMTpro-18plex: The Expanded and Complete Set of TMTpro Reagents for Sample Multiplexing
Li, J., Cai, Z., Bomgarden, R. D., Pike, I., Kuhn, K., Rogers, J. C., Roberts, T. M., Gygi, S. P., & Paulo, J. A. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00168 · Cited by 278
ThermoRawFileParser: Modular, Scalable, and Cross-Platform RAW File Conversion
Hulstaert, N., Shofstahl, J., Sachsenberg, T., Walzer, M., Barsnes, H., Martens, L., & Perez-Riverol, Y. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00328 · Cited by 248
MaxDIA enables library-based and library-free data-independent acquisition proteomics
Sinitcyn, P., Hamzeiy, H., Salinas Soto, F., Itzhak, D., McCarthy, F., Wichmann, C., Steger, M., Ohmayer, U., Distler, U., Kaspar-Schoenefeld, S., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00968-7 · Cited by 244
Multiplexed single-cell proteomics using SCoPE2
Petelski, A. A., Emmott, E., Leduc, A., Huffman, R. G., Specht, H., Perlman, D. H., & Slavov, N. (2021) · Nature Protocols · doi:10.1038/s41596-021-00616-z · Cited by 228 · cited 3×
“Mass-spectrometry (MS) methods can achieve deep proteome coverage 1,2 , low missing data 3 , high throughput 4,5 , and high sensitivity 6 .”
BackgroundMethodInfluentialSelf-citationUltrasensitive single-cell proteomics workflow identifies >1000 protein groups per mammalian cell
Cong, Y., Motamedchaboki, K., Misal, S. A., Liang, Y., Guise, A. J., Truong, T., Huguet, R., Plowey, E. D., Zhu, Y., Lopez-Ferrer, D., et al. (2021) · Chemical Science · doi:10.1039/d0sc03636f · Cited by 228
Post-transcriptional regulation across human tissues
Franks, A., Airoldi, E., & Slavov, N. (2017) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1005535 · Cited by 219
Self-citationDynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194
iTRAQ Labeling is Superior to mTRAQ for Quantitative Global Proteomics and Phosphoproteomics
Mertins, P., Udeshi, N. D., Clauser, K. R., Mani, D., Patel, J., Ong, S.-E., Jaffe, J. D., & Carr, S. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014423 · Cited by 190 · cited 3×
“We sought to further increase the throughput of sensitive DIA by multiplexing samples labeled with nonisobaric isotopologous mass tags, capitalizing on the fact that increasing the number of precursor ions does not increase the time needed to analyze them via tandem DIA-MS, in contrast to DDA-MS 13,19 .”
MethodKeshishian, H., Burgess, M. W., Specht, H., Wallace, L., Clauser, K. R., Gillette, M. A., & Carr, S. A. (2017) · Nature Protocols · doi:10.1038/nprot.2017.054 · Cited by 190
Self-citationProteome-Wide Evaluation of Two Common Protein Quantification Methods
O’Connell, J. D., Paulo, J. A., O’Brien, J. J., & Gygi, S. P. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.8b00016 · Cited by 173
Unpicking the proteome in single cells
Slavov, N. (2020) · Science · doi:10.1126/science.aaz6695 · Cited by 165 · cited 1×
“Resolving this challenge will empower biomedical projects that are impractical with current methods 8,9 .”
BackgroundSelf-citationSingle-cell protein analysis by mass spectrometry
Slavov, N. (2021) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2020.04.018 · Cited by 164
Self-citationMuntel, J., Kirkpatrick, J., Bruderer, R., Huang, T., Vitek, O., Ori, A., & Reiter, L. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.8b00898 · Cited by 163 · cited 2×
“Such par-2 allel analysis of peptides decreases the time needed to analyze thousands of precursor ions and makes the throughput of optimized LF-DIA and TMT-DDA workflows comparable, allowing routine quantification of about 6,000 proteins in 2 hours 15 .”
BackgroundExploring functional protein covariation across single cells using nPOP
Leduc, A., Huffman, R. G., Cantlon, J., Khan, S., & Slavov, N. (2022) · Genome Biology · doi:10.1186/s13059-022-02817-5 · Cited by 162
Self-citationEiler, J. M., César, J., Chimiak, L. M., Dallas, B., Grice, K., Griep‐Raming, J., Juchelka, D., Kitchen, N., Lloyd, M. K., Makarov, A., et al. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2017.10.002 · Cited by 159
Impact of the Identification Strategy on the Reproducibility of the DDA and DIA Results
Fernández-Costa, C., Martínez‐Bartolomé, S., McClatchy, D. B., Saviola, A. J., Yu, N., & Yates, J. R. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00153 · Cited by 151
Systematic proteome and proteostasis profiling in human trisomy 21 fibroblast cells
Liu, Y., Borel, C., Li, L., Müller, T., Williams, E. G., Germain, P.-L., Buljan, M., Sajic, T., Boersema, P. J., Shao, W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01422-6 · Cited by 141 · cited 2×
“Indeed, both SILAC and isobaric labeling reduce missing data by enabling the quantification of peptides identified in at least one sample from a labeled set 16,36 .”
BackgroundCoupling among growth rate response, metabolic cycle, and cell division cycle in yeast
Slavov, N., & Botstein, D. (2011) · Molecular Biology of the Cell · doi:10.1091/mbc.e11-02-0132 · Cited by 126 · cited 1×
“These results provide direct evidence for the suggested coordination among metabolism and cell division 39,40 .”
BackgroundSelf-citationTransformative Opportunities for Single-Cell Proteomics
Specht, H., & Slavov, N. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.8b00257 · Cited by 124 · cited 2×
“Indeed, plexDIA is motivated in part by ideas for achieving sensitive and multiplexed single-cell proteomics 7,17,26 .”
BackgroundSelf-citationHuffman, R. G., Leduc, A., Wichmann, C., Gioia, M. D., Borriello, F., Specht, H., Derks, J., Khan, S., Khoury, L., Emmott, E., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-01830-1 · Cited by 119
Self-citationFriedrich, C., Schallenberg, S., Kirchner, M., Ziehm, M., Niquet, S., Haji, M., Beier, C., Neudecker, J., Klauschen, F., & Mertins, P. (2021) · Nature Communications · doi:10.1038/s41467-021-23855-w · Cited by 101
Aguilar, V., & Fajas, L. (2010) · EMBO Molecular Medicine · doi:10.1002/emmm.201000089 · Cited by 100 · cited 1×
“These results provide direct evidence for the suggested coordination among metabolism and cell division 39,40 .”
BackgroundXuan, Y., Bateman, N. W., Gallien, S., Götze, S., Zhou, Y., Navarro, P., Hu, M., Parikh, N., Hood, B. L., Conrads, K. A., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18904-9 · Cited by 92 · cited 1×
“Mass-spectrometry (MS) methods can achieve deep proteome coverage 1,2 , low missing data 3 , high throughput 4,5 , and high sensitivity 6 .”
BackgroundAutomated sample preparation for high-throughput single-cell proteomics
Specht, H., Harmange, G., Perlman, D. H., Emmott, E., Niziolek, Z., Budnik, B., & Slavov, N. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/399774 · Cited by 75
Self-citationScaling Up Single-Cell Proteomics
Slavov, N. (2021) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2021.100179 · Cited by 74
Self-citationSalovska, B., Zhu, H., Gandhi, T., Frank, M., Li, W., Rosenberger, G., Wu, C., Germain, P., Zhou, H., Hodny, Z., et al. (2020) · Molecular Systems Biology · doi:10.15252/msb.20199170 · Cited by 71
Quantitative Analysis of mTRAQ-Labeled Proteome Using Full MS Scans
Kang, U., Yeom, J., Kim, H., & Lee, C. (2010) · Journal of Proteome Research · doi:10.1021/pr9011014 · Cited by 71 · cited 1×
“The small magnitude of this difference is likely attributable to the fact that mTRAQ stabilizes b-ions 37 .”
BackgroundBamberger, C., Pankow, S., Martínez-Bartolomé, S., Ma, M., Diedrich, J., Rissman, R. A., & Yates, J. R. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00912 · Cited by 70
Optimizing Accuracy and Depth of Protein Quantification in Experiments Using Isobaric Carriers
Specht, H., & Slavov, N. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00675 · Cited by 61
Self-citationPino, L. K., Baeza, J., Lauman, R., Schilling, B., & Garcia, B. A. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00938 · Cited by 58
DO-MS: Data-Driven Optimization of Mass Spectrometry Methods
Huffman, R. G., Chen, A., Specht, H., & Slavov, N. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00039 · Cited by 58
Self-citationDriving Single Cell Proteomics Forward with Innovation
Slavov, N. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00639 · Cited by 58 · cited 11×
“Thus, the sequence propagation can be more sensitive and reliable than with MBR 7 .”
BackgroundMethodInfluentialSelf-citationExploring frontiers of orbitrap performance for long transients
Denisov, E. V., Damoc, E., & Makarov, A. (2021) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2021.116607 · Cited by 48
Multiplexed Quantification for Data-Independent Acquisition
Minogue, C. E., Hebert, A. S., Rensvold, J. W., Westphall, M. S., Pagliarini, D. J., & Coon, J. J. (2015) · Analytical Chemistry · doi:10.1021/ac503593d · Cited by 46 · cited 2×
“Indeed, both SILAC and isobaric labeling reduce missing data by enabling the quantification of peptides identified in at least one sample from a labeled set 16,36 .”
BackgroundLearning from natural variation across the proteomes of single cells
Slavov, N. (2022) · PLoS Biology · doi:10.1371/journal.pbio.3001512 · Cited by 41
Self-citationIncreasing proteomics throughput
Slavov, N. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00881-z · Cited by 40 · cited 2×
“Resolving this challenge will empower biomedical projects that are impractical with current methods 8,9 .”
BackgroundSelf-citationSalovska, B., Li, W., Di, Y., & Liu, Y. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04293 · Cited by 35
Counting protein molecules for single-cell proteomics
Slavov, N. (2022) · Cell · doi:10.1016/j.cell.2021.12.013 · Cited by 27
Self-citationTian, X., de Vries, M. P., Permentier, H. P., & Bischoff, R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03858 · Cited by 27
Mass Defect-Based DiLeu Tagging for Multiplexed Data-Independent Acquisition
Zhong, X., Frost, D. C., Yu, Q., Li, M., Gu, T., & Li, L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01136 · Cited by 25
Towards resolving proteomes in single cells
Singh, A. (2021) · Nature Methods · doi:10.1038/s41592-021-01243-y · Cited by 25
Tian, X., de Vries, M. P., Permentier, H. P., & Bischoff, R. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00453 · Cited by 15
The synchronization manifesto: a critique of whole‐culture synchronization
Cooper, S. (2019) · FEBS Journal · doi:10.1111/febs.15050 · Cited by 14
Analyzing Ribosome Remodeling in Health and Disease
Petelski, A. A., & Slavov, N. (2020) · PROTEOMICS · doi:10.1002/pmic.202000039 · Cited by 13 · cited 1×
“Chemical labeling is often used with data-dependent acquisition (DDA) to increase through-put and control for shared artifacts, such as disturbances in peptide separation and ionization 10–12 .”
MethodSelf-citationHaynes, S. E., Majmudar, J. D., & Martin, B. R. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01618 · Cited by 12
Measuring Protein Shapes in Living Cells
Slavov, N. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00376 · Cited by 8 · cited 1×
“For example, plexDIA is readily compatible with the recently re-ported covalent protein painting that enables analysis of protein conformations in living cells 44,45 .”
MethodSelf-citation
Cited by
Single-cell proteomics enabled by next-generation sequencing or mass spectrometry
Bennett, H. M., Stephenson, W., Rose, C. M., & Darmanis, S. (2023) · Nature Methods · doi:10.1038/s41592-023-01791-5 · Cited by 351
Mass-spectrometry-based proteomics: from single cells to clinical applications
Guo, T., Steen, J. A., & Mann, M. (2025) · Nature · doi:10.1038/s41586-025-08584-0 · Cited by 320
Unbiased spatial proteomics with single-cell resolution in tissues
Mund, A., Brunner, A.-D., & Mann, M. (2022) · Molecular Cell · doi:10.1016/j.molcel.2022.05.022 · Cited by 259
An Introduction to Mass Spectrometry-Based Proteomics
Shuken, S. R. (2023) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00838 · Cited by 223
Comprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Metadata
- Authors
- Derks, J., Leduc, A., Wallmann, G., Huffman, R. G., Willetts, M., Khan, S., Specht, H., Ralser, M., Demichev, V., & Slavov, N.
- Venue
- Nature Biotechnology
- Published
- 2022-07-14
- Volume
- 41
- Issue
- 1
- Pages
- 50-59
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W4285388424
- Cited by
- 232
- References
- 66
- FWCI
- 16.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.