CoChat

Decoder-seq enhances mRNA capture efficiency in spatial RNA sequencing

Cao, Jiao, Zheng, Zhong, Sun, Di, Chen, Xin, Cheng, Rui, Lv, Tianpeng, An, Yu, Zheng, Junhua, Song, Jia, Wu, Lingling, Yang, Chaoyong · 2024 · Nature Biotechnology

The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.

Abstract

Spatial transcriptomics technologies with high resolution often lack high sensitivity in mRNA detection. Here we report a dendrimeric DNA coordinate barcoding design for spatial RNA sequencing (Decoder-seq), which offers both high sensitivity and high resolution. Decoder-seq combines dendrimeric nanosubstrates with microfluidic coordinate barcoding to generate spatial arrays with a DNA density approximately ten times higher than previously reported methods while maintaining flexibility in resolution. We show that the high RNA capture efficiency of Decoder-seq improved the detection of lowly expressed olfactory receptor (Olfr) genes in mouse olfactory bulbs and contributed to the discovery of a unique layer enrichment pattern for two Olfr genes. The near-cellular resolution provided by Decoder-seq has enabled the construction of a spatial single-cell atlas of the mouse hippocampus, revealing dendrite-enriched mRNAs in neurons. When applying Decoder-seq to human renal cell carcinomas, we dissected the heterogeneous tumor microenvironment across different cancer subtypes and identified spatial gradient-expressed genes related to epithelial-mesenchymal transition with the potential to predict tumor prognosis and progression.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41587-023-02086-y

Cites

76 of 76 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 76 references

Research works printed but not linked: 1

  1. Cao, J. et al. Decoder-seq enhances mRNA capture efficiency in spatial RNA sequencing. Gene Expression Omnibus https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSE235896 (2023).

Cited by

See all 71

Metadata

Authors
Cao, J., Zheng, Z., Sun, D., Chen, X., Cheng, R., Lv, T., An, Y., Zheng, J., Song, J., Wu, L., & Yang, C.
Affiliations
Shanghai Jiao Tong University (CN)
Corresponding author
  • Zheng, Junhua
  • Song, Jia
  • Wu, Lingling
  • Yang, Chaoyong
Venue
Nature Biotechnology
Published
2024-01-16
Volume
42
Issue
11
Pages
1735-1746
ISSN
  • 0733-222X (ISSN-L)
  • 1087-0156
  • 1546-1696
OpenAlex
W4390918213
Cited by
71
References
69
Citations by year
2026: 30 · 2025: 28 · 2024: 13
FWCI
9.56
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Nature Biotechnology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (22104080, 22004083, 22293031, 21927806)
  • China Postdoctoral Science Foundation (2021M702167)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Single-cell and spatial transcriptomics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
Keywords
spatial transcriptomics, olfactory receptor genes, olfactory bulb, renal cell carcinoma, tumor microenvironment, epithelial-mesenchymal transition, spatial gradients, cancer prognosis
MeSH terms
Animals, Carcinoma, Renal Cell, Humans, Kidney Neoplasms, Olfactory Bulb, RNA, Messenger, Sequence Analysis, RNA, Receptors, Odorant, Gene Expression Profiling, Mice, Single-Cell Analysis, Tumor Microenvironment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Decoder-seq enhances mRNA capture efficiency in spatial RNA sequencing. https://app.cochat.ai/papers/10.1038/s41587-023-02086-y
The paper
Cao, J., Zheng, Z., Sun, D., Chen, X., Cheng, R., Lv, T., An, Y., Zheng, J., Song, J., Wu, L., & Yang, C. (2024). Decoder-seq enhances mRNA capture efficiency in spatial RNA sequencing. Nature Biotechnology. https://doi.org/10.1038/s41587-023-02086-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.