Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Peripheral nerve injuries represent a significant problem in public health, constituting 2-5% of all trauma cases 1 . For severe nerve injuries, even advanced forms of clinical intervention often lead to incomplete and unsatisfactory motor and/or sensory function 2 . Numerous studies report the potential of pharmacological approaches (for example, growth factors, immunosuppressants) to accelerate and enhance nerve regeneration in rodent models 3-10 . Unfortunately, few have had a positive impact in clinical practice. Direct intraoperative electrical stimulation of injured nerve tissue proximal to the site of repair has been demonstrated to enhance and accelerate functional recovery 11,12 , suggesting a novel nonpharmacological, bioelectric form of therapy that could complement existing surgical approaches. A significant limitation of this technique is that existing protocols are constrained to intraoperative use and limited therapeutic benefits 13 . Herein we introduce (i) a platform for wireless, programmable electrical peripheral nerve stimulation, built with a collection of circuit elements and substrates that are entirely bioresorbable and biocompatible, and (ii) the first reported demonstration of enhanced neuroregeneration and functional recovery in rodent models as a result of multiple episodes of electrical stimulation of injured nervous tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Utilizing a deposited layer of Mg embedded in insulting polymer to deliver electrical stimuli from the receiver antenna to the tissue, the system successfully enhanced neuroregeneration and functional recovery in rodent models (Figure 15F).[303]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [303]
Citations
Cites
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Natural-based plasticizers and biopolymer films: A review
Vieira, M. G. A., da Silva, M. A., dos Santos, L. O., & Beppu, M. M. (2011) · European Polymer Journal · doi:10.1016/j.eurpolymj.2010.12.011 · Cited by 1,992
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Self-citationNoble, J., Munro, C. A., Prasad, V. S. S. V., & Midha, R. (1998) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199807000-00025 · Cited by 995
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.004 · Cited by 814
Density and composition of mammalian muscle
Méndez, J., & Keys, A. (1960) · Metabolism · Cited by 802
Development of fibrin derivatives for controlled release of heparin-binding growth factors
Sakiyama-Elbert, S. E., & Hubbell, J. A. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00221-7 · Cited by 565
FIBER ARCHITECTURE AND MUSCLE FUNCTION
Gans, C. (1982) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198201000-00006 · Cited by 491
Dissolvable Metals for Transient Electronics
Yin, L., Cheng, H., Mao, S., Haasch, R., Liu, Y., Xie, X., Hwang, S., Jain, H., Kang, S., Su, Y., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201301847 · Cited by 487
Self-citation
Research works printed but not linked: 1
- Winter, W. G., Schutt, R. C., Sisken, B. F. & Smith, S. D. Effects of low levels of direct current on peripheral nerve regeneration. Trans. Orthop. Res. Soc. 6, 304 (1981).
Cited by
Items 301–400 of 521
Birenbaum, N. K., Yan, Y., Odabas, A., Chandra, N. S., Ray, W. Z., & MacEwan, M. R. (2022) · Muscle & Nerve · doi:10.1002/mus.27776 · Cited by 15
“This 6 days’ time course corroborates previous findings from our lab in a simple transection and coaptation model.(10) However, this study's use of a long isograft model implies that the”
BackgroundMethodResultSelf-citationAdvances in Symbiotic Bioabsorbable Devices
Zhu, C., Wang, E., Li, Z., & Ouyang, H. (2025) · Advanced Science · doi:10.1002/advs.202410289 · Cited by 16
Water-soluble energy harvester as a promising power solution for temporary electronic implants
Zhang, Q., Liang, Q., & Rogers, J. A. (2020) · APL Materials · doi:10.1063/5.0031151 · Cited by 15
Self-citation3D conductive material strategies for modulating and monitoring cells
Li, X., Mao, M., Han, K., Yao, C., Gu, B., He, J., & Li, D. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101041 · Cited by 16
Dai, F., Cheng, H., Qi, H., Cai, H., Aziz, A., Su, T., Guan, Y., Cui, Y., Meng, J., Deng, H., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-68930-2 · Cited by 17
“Overall, the sustained electrical cues generated by the piezo-electric scaffold device under US stimulation during the early phase of nerve injury are expected to trigger regenerative cascades and support long-term recovery of damaged nerve tissue 79,81,82 .”
Functional material-mediated wireless physical stimulation for neuro-modulation and regeneration
Li, J., Wu, C., Zeng, M., Zhang, Y., Wei, D., Sun, J., & Fan, H. (2023) · Journal of Materials Chemistry B · doi:10.1039/d3tb01354e · Cited by 14
A system for bioelectronic delivery of treatment directed toward wound healing
Baniya, P., Tebyani, M., Asefifeyzabadi, N., Nguyen, T., Hernandez, C., Zhu, K., Li, H., Selberg, J. A., Hsieh, H., Pansodtee, P., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-41572-w · Cited by 15
Embracing Remote Fields as the Fourth Dimension of Tissue Biofabrication
Anand, S., Müller, C., Jensen, B. N., & Chen, M. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202401654 · Cited by 14
Kennedy, V., Long, M. D., Walters, J. B., Adewuyi, A. A., & Franz, C. K. (2025) · Advanced technology in neuroscience . · doi:10.4103/atn.atn-d-24-00023 · Cited by 17
Ke, Y., Li, T., Li, J., Pei, M., Wang, X., Xie, W., Zhuang, S., Ye, X., Li, Z., Wang, Z., et al. (2025) · eScience · doi:10.1016/j.esci.2025.100436 · Cited by 15
SURGICAL TREATMENT OF PERIPHERAL NERVES COMBAT WOUNDS OF THE EXTREMITIES
Цымбалюк, В. И., Strafun, S. S., Tretyak, I. B., Tsymbaliuk, V., Gatskiy, A. A., Tsymbaliuk, Y., & Tatarchuk, M. M. (2021) · Wiadomości Lekarskie · doi:10.36740/wlek202103210 · Cited by 13
chu, X., Song, X., Li, Y., Wu, Z., Li, Q., Li, Q., Gu, X., & Ming, D. (2022) · Neural Regeneration Research · doi:10.4103/1673-5374.350215 · Cited by 13
“Other studies (Koo et al., 2018; Zhang et al., 2018) have shown that stimulating electrodes placed both proximal and distal to the injury site can improve nerve regeneration and lead to better functional outcomes.”
BackgroundKong, J., Teng, C., Liu, F., Wang, X., Zhou, Y., Zong, Y., Wan, Z., Qin, J., Yu, B., Mi, D., et al. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1361590 · Cited by 13
Evolution of Musculoskeletal Electronics
Li, J., Zhang, F., Lyu, H., Yin, P., Shi, L., Li, Z., Zhang, L., Di, C., & Tang, P. (2024) · Advanced Materials · doi:10.1002/adma.202303311 · Cited by 16
Bai, W., Irie, M., Liu, Z., Luan, H., Franklin, D., Nandoliya, K. R., Guo, H., Zang, H., Weng, Y., Lu, D., et al. (2021) · BME Frontiers · doi:10.34133/2021/8653218 · Cited by 13
“…neural activity, and cerebral temperature [20, 21]; (2) electronic sensors to measure pressures in the intracranial, intraocular, and intravascular spaces [22, 23]; and (3) wireless stimulators to provide a nonpharmacological means to accelerate healing of damaged peripheral nerves [24].”
BackgroundSelf-citationOrganic electronics for neuroprosthetics
Airaghi Leccardi, M. J. I., & Ghezzi, D. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0108 · Cited by 12
Bioelectronic drug-free control of opportunistic pathogens through selective excitability
Kim, S., Eig, E., Yue, J., Yang, A., Comerci, C. J., Laune, M., Yang, C., Kamath, A., Shi, J., Li, P., et al. (2024) · Device · doi:10.1016/j.device.2024.100596 · Cited by 12
Self-citationRiva, E. R., Özkan, M., Stellacci, F., & Micera, S. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1491260 · Cited by 14
“A recent study introduced a wireless, bioresorbable nerve stimulator with cuff electrodes, showing that multiple 1-h daily sessions of monophasic electrical impulses for 6 weeks days signi fi cantly accelerated muscle reinnervation compared to sham stimulation (Koo et al., 2018).”
Meng, Z., Gu, B., Yao, C., Li, J., Yu, K., Ding, Y. C., He, P., Jiang, N., Li, D., & He, J. (2024) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad9365 · Cited by 14
“To address this challenge, Koo et al developed a biocompatible ES device for neuro-regenerative therapy [251].”
Emerging optoelectronic technologies for next-generation leadless bioelectronic modulation
Yitzhak-David, S. L., & Rotenberg, M. Y. (2023) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2023.101414 · Cited by 13
Hybrid materials approaches for bioelectronics
Bai, H., Hu, Z., & Rogers, J. A. (2023) · MRS Bulletin · doi:10.1557/s43577-023-00620-6 · Cited by 13
Self-citationBioresorbable molybdenum temporary epicardial pacing wires
Jarabo, M. P., Redlich, C., Schauer, A., Alves, P. K. N., Guder, C., Poehle, G., Weissgaerber, T., Adams, V., Kappert, U., El‐Armouche, A., et al. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.02.039 · Cited by 14
Advances in Bioresorbable Electronics and Uses in Biomedical Sensing
Kuzma, M., Gerhard, E. M., Shan, D., & Yang, J. Y. (2020) · Springer eBooks · doi:10.1007/978-3-030-34467-2_2 · Cited by 13
Biology-guided engineering of bioelectrical interfaces
Miao, B. A., Meng, L., & Tian, B. (2022) · Nanoscale Horizons · doi:10.1039/d1nh00538c · Cited by 12
GelBat: An Edible Gelatin-Based Battery
Chen, H., Keller, A., Conn, A. T., & Rossiter, J. M. (2023) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft55895.2023.10121947 · Cited by 11
“Although this is a nascent field, many different edible devices have been demonstrated, such as sensors [23], [24], tissue stimulants [25], super capacitors [26] and actuators [27], [28].”
BackgroundPhysiology of Nerve Regeneration
Gordon, T. (2024) · Hand Clinics · doi:10.1016/j.hcl.2024.03.001 · Cited by 12
Recent advances in encapsulation strategies for flexible transient electronics
Han, W. B., Hwang, S., & Yeo, W. (2024) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ad6a6c · Cited by 11
Advances in wearable and implantable devices for wireless electrical stimulation therapy
Zhang, Y., Wang, Y., Zhao, K., Yang, M., Ye, Z., & Zhang, X. (2025) · Discover Electronics · doi:10.1007/s44291-025-00046-1 · Cited by 11
“In addition, Koo et al. [70] combined an RF power harvester with an electrical interface to the target peripheral nerve to For the design of absorbable wireless battery-free electrostimulation devices, materials have a crucial impact on their practical applications, such as the number of days of…”
Advances in mechanically active materials for soft wearable electronics
Wu, K., He, W. H., Zhong, R., Nie, Z., Lin, X., & Han, M. (2025) · Materials Horizons · doi:10.1039/d5mh00563a · Cited by 15
Lin, C.-W., Chen, S.-H., Cheng, S. M., Chung, T.-C., Liu, W., Hwang, D., Li, S., Lin, S.-C., & Hsueh, Y. (2025) · Stem Cell Research & Therapy · doi:10.1186/s13287-025-04459-3 · Cited by 12
Transient electronics for sustainability: Emerging technologies and future directions
Bae, J., Choi, M.-K., & Kang, S. (2025) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.16.109 · Cited by 12
Self-citationKim, M., Yeon, P., Ruth, S. R. A., Park, J., Lai, J., Zhong, D., Xu, C., Kim, J., Arbabian, A., Fox, P. M., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2528796123 · Cited by 14
Self-citationA novel transient strategy: transient electronics based on energetic materials
Wang, Y., Ma, Z., He, W., Zhang, Y., & Liu, P. (2024) · Defence Technology · doi:10.1016/j.dt.2024.04.013 · Cited by 12
Diabetic peripheral neuropathy: An insight into the pathophysiology, diagnosis, and therapeutics
Khandelwal, P., & Khanna, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816413-6.00004-6 · Cited by 11
Ortolá, I. C., Martínez-Rojas, B., Moreno‐Manzano, V., Castelló, M. G., Pradas, M. M., Martínez‐Ramos, C., & Estellés, J. M. (2022) · Biomedicines · doi:10.3390/biomedicines10112736 · Cited by 12
“Some studies have tried to develop implantable electronic devices, avoiding transcutaneous wires, but anatomical pockets need to be implanted [44,45].”
BackgroundLong-term implantable flexible neural interfaces for electrophysiological monitoring
Chen, B., Lu, J., Chen, Z., Han, X., Sun, Y., Lin, X., Tang, Z., Jia, S., Xie, G., Huo, F., et al. (2025) · Journal of Materials Chemistry C · doi:10.1039/d4tc04289a · Cited by 10
Technical roadmap of ultra-thin crystalline silicon-based bioelectronics
Sang, M., Kim, K., Lee, D., Cho, Y. U., Lee, J. W., & Yu, K. J. (2025) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/add7a4 · Cited by 11
“Reproduced from [118] , with permission from Springer Nature.”
Wireless, passive inductor-capacitor sensors for biomedical applications
Xu, B., Patel, S. B., & Yu, C. (2025) · Med-X · doi:10.1007/s44258-025-00060-8 · Cited by 12
Woo, S., Kim, H.-J., Kim, J.-H., Ryu, H., & Lee, J. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202300653 · Cited by 10
Self-citationNarayanan, R. P., Khaleghi, A., Veletić, M., & Balasingham, I. (2024) · PLoS ONE · doi:10.1371/journal.pone.0297114 · Cited by 10
Neuman, K. E., Zhang, X., Schellberg, B. G., Lewis, L. H., Koppes, A. N., & Koppes, R. A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adbb1e · Cited by 9
“Two studies applied repeated ES with a frequency of 20 Hz in vivo and saw increased recovery in animals that received stimulation for 1 h a day for 6 d [71, 72].”
Wearable and implantable transient bioelectronics
Wang, Y., Wu, C., Zhang, Y., Du, S., & Zhou, X. (2025) · Journal of Materials Chemistry C · doi:10.1039/d5tc01911g · Cited by 10
Emergency delivery of particulate drugs by active ejection using in vivo wireless devices
Krishnan, S. R., O’Keeffe, L., Rudra, A., Gumustop, D. R., Khatib, N., Liu, C., Yang, J., Wang, A., Bochenek, M. A., Lu, Y., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01436-2 · Cited by 10
“Operation at 13.56 MHz is chosen for its compatibility with existing NFC communication infrastructure in handheld smartphone and tablet devices, compatibility with both wearable 37–39 and implantable 40,41 bioelectronic systems and low specific absorption rates in biological tissue 42 .”
InfluentialYu, M., Kim, Y., Nam, S., Cha, G. D., & Kim, D. (2025) · Health Nanotechnology · doi:10.1186/s44301-025-00012-6 · Cited by 10
A Sewing Approach to the Fabrication of Eco/bioresorbable Electronics
Wu, Y., Rytkin, E., Bimrose, M. V., Li, S., Choi, Y. S., Lee, G., Wang, Y., Tang, L., Madrid, M. K., Wickerson, G., et al. (2023) · Small · doi:10.1002/smll.202305017 · Cited by 9
Self-citationA Perspective on Electrical Stimulation and Sympathetic Regeneration in Peripheral Nerve Injuries
Tian, T. M., Moore, A. M., Ghareeb, P. A., Boulis, N. M., & Ward, P. J. (2024) · Neurotrauma Reports · doi:10.1089/neur.2023.0133 · Cited by 9
“13,18 On the contrary, it is worthy to note that daily 1-h ES sessions for 1 week post-repair resulted in improved motor axon regeneration compared to a single application of ES at the time of nerve repair in rats, 22 so the ideal paradigm appears to be unclear.”
BackgroundLiving electronics in cellulose zoogleal mats
Mougkogiannis, P., Nikolaidou, A. E., & Adamatzky, A. (2024) · Carbohydrate Polymer Technologies and Applications · doi:10.1016/j.carpta.2024.100627 · Cited by 10
Lee, T., Kim, S.-M., Kim, J., Park, S.-C., Yoon, J., Park, C., Sohn, H., Ahn, J., & Min, J. (2020) · Materials · doi:10.3390/ma13163520 · Cited by 9
“For example, implantable bioelectronic devices offer new opportunities to patients with incurable nerve system disorders [20,21,28,29].”
BackgroundSelf-citationShrestha, S., Shrestha, B. K., Joong, O. K., Park, C. H., & Kim, C. S. (2020) · Biomaterials Science · doi:10.1039/d0bm01034k · Cited by 9
Biodegradable materials and devices for neuroelectronics
Kim, G., Hong, M., Lee, Y., & Koo, J. (2023) · MRS Bulletin · doi:10.1557/s43577-023-00529-0 · Cited by 10
Self-citationMaterials for biointegrated electronic and microfluidic systems
Rogers, J. A. (2019) · MRS Bulletin · doi:10.1557/mrs.2019.46 · Cited by 9
Self-citationBionic tissue engineering of peripheral nerves and progress in neuroregeneration
Jiao, D., Yang, Y., Lu, P., Gu, X., & Ming, D. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.162123 · Cited by 8
Yamada, S., & Honda, T. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c04965 · Cited by 9
Kim, K., Shin, Y., Lee, W., & Kang, S. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500400 · Cited by 9
Self-citationZhou, J., Zhao, H., Zhang, J., He, Y., Yin, A., Wu, X., Wang, Z., Meng, D., Zhao, J., Wang, X., et al. (2026) · Advanced Materials · doi:10.1002/adma.202520861 · Cited by 8
“Electromagnetic energy radiated from the transmitting coil (L 1 ) can be harvested bythereceivingcoil(L 2 )throughthenearfieldinductivecoupling to generate alternating current (AC) voltage with the frequency same as the AC input of L 1 [10].”
Multi‐Functional Adaptive Interfaces for Next‐Generation Wearable and Implantable Bioelectronics
Park, J., Ha, J., Kim, D. G., Lee, S., Jung, H., Koo, J. H., Cha, G. D., & Kim, D. C. (2026) · Advanced Science · doi:10.1002/advs.202600043 · Cited by 10
“For example, a biodegradable nerve stimulation platform fabricated from hot-pressed PLGA was demonstrated, wherein the substrate interfaced directly with neural tissue and gradually resorbed over the course of treatment (Figure 8i ) [ 79 ].”
Self-citationIntegration of Ultrathin Silicon and Metal Nanowires for High‐Performance Transparent Electronics
Koo, J., Lee, C., Chu, C. R., Kang, S., & Lee, H. M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201900962 · Cited by 8
Self-citationA Water-Resistant, Self-Healing Encapsulation Layer for a Stable, Implantable Wireless Antenna
An, S., Lyu, H. S., Seong, D., Yoon, H. S., Kim, I. S., Lee, H., Shin, M., Hwang, K. C., & Son, D. (2023) · Polymers · doi:10.3390/polym15163391 · Cited by 11
Self-citationWei, Z., Ma, X., Zhao, H., Wu, X., & Guo, Q. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c04647 · Cited by 8
Pion, A.-M. J., Roy, A.-A., Ma, X., Beaumont, É., & Lin, J. C. (2023) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000003463 · Cited by 8
Yamada, S., & Honda, T. (2024) · Nanoscale · doi:10.1039/d4nr03321c · Cited by 8
Thermoresponsive Transient Radio Frequency Antennas: Toward Triggered Wireless Transient Circuits
Zhang, X., Weber, C. M., & Bellan, L. M. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900528 · Cited by 8
Soft ionic devices by perfusable all-hydrogel microfluidics
Liu, Z., Zhang, Y., Yang, T., Liu, Y., Zhou, W. Y., Wang, Z., Liu, Y., & Kong, T. (2020) · Journal of Materials Chemistry C · doi:10.1039/c9tc05639d · Cited by 8
Optical wireless data transfer through skin for implantable biomedical electronics
Hong, C., Jung, D., Lee, T., & Lee, J. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00500-w · Cited by 7
“To support and restore these functions, a wide range of implantable electronic medical devices, such as pacemakers 4,5 , nerve stimulators 6,7 , arti fi cial retina 8,9 , and cochlear 10,11 have been developed with an aim to extend lifespan and improve quality of life signi fi cantly.”
Peripheral nerve repair: innovations and future directions
Aldali, F., 唐莉, Yang, Y., Huang, Y., Li, Y., Deng, C., & Chen, H. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-025-07567-z · Cited by 10
“Recently, bioresorbable electronic stimulators have emerged as a promising technology in bioelectronic medicines, offering a novel therapeutic platform for modulating disease processes, accelerating wound repair, and eliminating infections to improve clinical outcomes [277].”
Self-citationTissue-fluid-driven symbiotic electronic textile accelerates and guides tissue self-healing
Wang, E., Xu, L., Luo, L., Ren, Y., Quan, Y., Le, T., Xue, J., Zhu, C., Huang, J., Cui, X. J., et al. (2026) · Cell Biomaterials · doi:10.1016/j.celbio.2026.100375 · Cited by 7
Intisar, A., Woo, H., Kang, H. G., Kim, W., Shin, H. Y., Kim, M. Y., Kim, Y. S., Mo, Y. J., Lee, Y., & Kim, M. S. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.115055 · Cited by 7
Xie, Y., Qin, P., Guo, T., Abed, A. A., Lovell, N. H., & Tsai, D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/aced20 · Cited by 8
Hu, Z., Zhao, J., Guo, H., Li, R., Wu, M., Shen, J., Wang, Y., Zheng, Q., Xu, Y., Haugstad, G. D., et al. (2024) · Advanced Materials · doi:10.1002/adma.202307782 · Cited by 9
Self-citationKim, S., Kim, T., Kim, H., Kim, J., Rogers, J. A., & Hahn, S. K. (2024) · Advanced Materials · doi:10.1002/adma.202413189 · Cited by 12
Self-citationSánchez, E. N., Rodríguez-Díaz, M., Núñez-Rodríguez, S., la Fuente, A. B.-D., Anuncibay, R. D. L. F., Villar‐Suárez, V., Gonzalez-Bernal, J. J., & Labrador, J. (2025) · Cells · doi:10.3390/cells14070492 · Cited by 7
“Current surgical procedures face significant limitations, such as mismatched calibers of repaired nerves, disorganization of nerve fibers at the suture site, and the potential formation of perineural scars that inhibit axonal growth [5,26,27].”
A self-powered nerve conduit based on zinc-oxygen battery accelerates nerve cell growth
Qi, F., Zou, Z., Li, H., Gao, X., Shuai, X., Li, Z., & Shuai, C. (2025) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2025.137225 · Cited by 7
2D Carbon Material‐Based Bio‐Abiotic Interfaces
Du, H., Chen, W., Kong, X., & Wen, L. (2025) · Small Methods · doi:10.1002/smtd.202500662 · Cited by 8
Biomedical Applications of Bioresorbable Mechanical Sensors
Wu, Y., Liu, Z., & Fan, Y. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202513422 · Cited by 9
Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing
Wang, H., D’Andrea, D., Choi, Y. S., Bouricha, Y., Wickerson, G., Ahn, H., Guo, H., Huang, Y. Y., Sandhu, M. S., Jordan, S. W., et al. (2021) · Journal of Visualized Experiments · doi:10.3791/63085 · Cited by 7
Self-citationMultidimensional Oriented Piezoelectric Conduits for Peripheral Nerve Defect Regeneration
Qi, T., Wang, X., Wu, L., Han, M., Zhou, C., Wu, B. Y., Pei, X., & He, C. (2026) · Small · doi:10.1002/smll.202514376 · Cited by 6
Biodegradable sensor platforms
Bathaei, M. J., Singh, R., Istif, E., & Beker, L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88431-0.00015-6 · Cited by 7
Wireless Battery‐Free Peripheral Nerve Stimulation Conch for Remote Muscle Activation
Mingwang, Z., Yang, G., Long, Z., Tang, Y. C., Li, D., Liang, S., Lin, R., Yang, Z., Bao, H., Xing, L., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202301458 · Cited by 6
Millimetric devices for nerve stimulation: a promising path towards miniaturization
Dorrian, R. M., Leonard, A. V., & Lauto, A. (2023) · Neural Regeneration Research · doi:10.4103/1673-5374.389627 · Cited by 6
“The device is highly bioresorbable, with constituent material dissolving within three weeks after immersion in PBS at 37°C. Koo et al. (2018) implanted the device onto the rodent sciatic nerve and inserted the harvester into a subcutaneous pocket over the hind limb.”
BackgroundMethodSenger, J. B., Power, H. A., & Moore, A. M. (2024) · Hand Clinics · doi:10.1016/j.hcl.2024.03.007 · Cited by 7
Hierarchical assembly of electrospun nanofibers for the next generation tissue repairing materials
Wang, Y., Yue, G., Bai, T., Liu, F., Wang, N., Bai, J., Kong, L., & Zhao, Y. S. (2025) · Sustainable materials and technologies · doi:10.1016/j.susmat.2025.e01355 · Cited by 7
Targeting the cytoskeleton in heart failure
Fernández-Ruíz, I. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0056-2 · Cited by 6
Intisar, A., Shin, H. Y., Kim, W., Kang, H. G., Kim, M. Y., Kim, Y. S., Mo, Y. J., Mo, Y. J., Lim, H., Lee, S., et al. (2022) · Advanced Science · doi:10.1002/advs.202201358 · Cited by 7
Self-citationSilicon-based transient electronics: principles, devices and applications
Zhao, H., Liu, M., & Guo, Q. (2024) · Nanotechnology · doi:10.1088/1361-6528/ad3ce1 · Cited by 6
“For example, silicon oxide ( SiO 2 ) [ 77 ] , silicon nitride ( Si 3 N 4 ) [ 67 ] , could serve as the dielectrics for transient transistors and capacitors.”
InfluentialStretchable self-powered epidermal electronics from piezoelectric rubber for tactile sensing
Yao, K., Yao, J.-Y., Hai, Z., Li, D., Xie, Z., & Yu, X. (2020) · Acta Physica Sinica · doi:10.7498/aps.69.20200664 · Cited by 6
Self-citationBalog, B. M., Deng, K., Askew, T., Kuang, M., Hanzlicek, B., & Damaser, M. S. (2021) · Experimental Neurology · doi:10.1016/j.expneurol.2021.113781 · Cited by 6
Materials design for resilience in the biointegration of electronics
Lin, A., Uva, A., Babi, J., & Tran, H. (2021) · MRS Bulletin · doi:10.1557/s43577-021-00174-5 · Cited by 7
Considerations for Small Animal Physical Rehabilitation
Greising, S. M., Basten, A. M., Schifino, A. G., & Call, J. A. (2022) · Physiology in health and disease · doi:10.1007/978-3-030-95884-8_2 · Cited by 6
Wang, A., Song, W., Guo, W., Huang, B., Zhu, X., Zhang, H., Zhai, W., Tian, Y., & Ren, L. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.08.023 · Cited by 9
Zhou, M., Yan, B., Yang, F., Chen, C., Wang, F., Xu, C., Jiang, T., Li, K., Xie, Y., Zheng, H., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-63746-y · Cited by 5
“Latest advancements have achieved features such as fully implantable designs 37 , absorbability 38 , programmability 39 , and closed-loop control with concurrent electromyographic monitoring 40 – 43 .”
Bioresorbable Systems in Healthcare for Transient Sensing and Therapeutic Interventions
Kim, J., Seo, Y., & Kim, J. (2026) · Advanced Therapeutics · doi:10.1002/adtp.202500544 · Cited by 5
“Bioresorbable implants for electrical stimulation (ES) have emerged as powerful, non-pharmacological tools to promote peripheral nerve regeneration [11, 117].”
Self-citationTransforming healthcare through in-body bioelectronic systems
Ceto, S., Elshove, S. A., Wu, M., Ramadi, K. B., Tondera, C., Minev, I. R., Srinivasan, S. S., Lee, K., Gora, M. J., Rogers, J. A., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-71188-3 · Cited by 5
“Emerging materials and device architectures are enabling fl exible, stretchable bioelectronic interfaces that better integrate with dynamic three-dimensional tissues while expanding implanted systems beyond traditional prosthetics toward broader therapeutic and tissue-repair applications 9 – 11 (Fig.”
Self-citationBioinspired Intelligent Electronic Skin for Medicine and Healthcare
Liu, Z., Hu, J., & Shen, G. (2025) · Small Methods · doi:10.1002/smtd.202402164 · Cited by 10
Electrochemical biomaterials for self-powered implantable “tissue batteries”: A tutorial review
Zheng, M., Wang, X., Yue, O., Bai, Z., Cui, B., & Liu, X. (2022) · Nano Research · doi:10.1007/s12274-022-5191-8 · Cited by 5
Yuan, L., Zhu, Y., Li, J., Jiang, C., Xu, Q., Wang, X., Liu, X., Wang, X., Zhang, A., Zhang, T., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202523049 · Cited by 6
Liu, P., Zhou, L., Xu, D., An, D., Lu, Y., Hu, B., Shao, Y., Huang, N., Guo, C., Chen, L., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2521817123 · Cited by 6
“Advanced technologies for high - precision, in vivo treatments of localized peripheral nerve injury (PNI) provide broad utility both in biomedical research as well as in clinical practice (1 , 2).”
Peptide‐Incorporated Biomaterials Promote Regeneration of Peripheral Nerve Injuries
Zhao, Z., Liu, J., Li, J., Li, D., Ding, J., & Liu, B. (2026) · Advanced Science · doi:10.1002/advs.202524264 · Cited by 8
Pathak, P. K., & Ghosh, B. D. (2026) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6c00283 · Cited by 4
Kim, J. U., Seo, S. G., Wang, H., Rytkin, E., Gong, J., Zhou, J., Choi, J., Kim, J., Park, S.-J., Pfenniger, A., et al. (2026) · Nature Electronics · doi:10.1038/s41928-026-01655-8 · Cited by 5
“Guided by previous reports on localized nerve stimulation 11 and conduction block 35 , we implemented bipolar and tripolar cuff electrode configurations.”
InfluentialSelf-citationChiral-induced spin selectivity in chiral solid-state materials for biomedical engineering
Gao, R., Meng, D., & Lu, X. (2026) · Communications Materials · doi:10.1038/s43246-026-01272-0 · Cited by 5
“Existing implantable neural stimulators, such as those used for deep brain stimulation, vagus nerve stimulation, and spinal cord modulation, deliver electrical pulses through metal electrodes that lack selectivity in the spin character of injectedcharge 254 .”
Metadata
- Authors
- Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., Birenbaum, N., Chung, S., Kim, S. B., Khalifeh, J., Harburg, D. V., Bean, K., Paskett, M., Kim, J., Zohny, Z. S., Lee, S. M., Zhang, R., Luo, K., Ji, B., Banks, A., Lee, H. M., Huang, Y., Ray, W. Z., & Rogers, J. A.
- Affiliations
- Northwestern University (US)
- Washington University in St. Louis (US)
- Korea Advanced Institute of Science and Technology (KR)
- University of Illinois Urbana-Champaign (US)
- Kwangwoon University (KR)
- Corresponding author
- Ray, Wilson Z.
- Rogers, John A.
- ORCID
- Venue
- Nature Medicine
- Published
- 2018-10-08
- Volume
- 24
- Issue
- 12
- Pages
- 1830-1836
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W2895321679
- Semantic Scholar
- 3206c70eed25bc433cf39f22ff2cc137874feb87
- Cited by
- 496
- References
- 49
- Citations by year
- 2026: 41 · 2025: 69 · 2024: 77 · 2023: 69 · 2022: 63 · 2021: 81 · 2020: 62 · 2019: 33 · 2018: 1
- FWCI
- 20.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- peripheral nerve injury, peripheral nerve regeneration, electrical nerve stimulation, functional recovery, rodent models
- MeSH terms
- Electric Stimulation, Humans, Nerve Regeneration, Wound Healing, Recovery of Function, Absorbable Implants, Wireless Technology, Peripheral Nerve Injuries
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.