The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Activity-dependent spinal cord neuromodulation rapidly restores trunk and leg motor functions after complete paralysis
Open accessAbstract
Epidural electrical stimulation (EES) targeting the dorsal roots of lumbosacral segments restores walking in people with spinal cord injury (SCI). However, EES is delivered with multielectrode paddle leads that were originally designed to target the dorsal column of the spinal cord. Here, we hypothesized that an arrangement of electrodes targeting the ensemble of dorsal roots involved in leg and trunk movements would result in superior efficacy, restoring more diverse motor activities after the most severe SCI. To test this hypothesis, we established a computational framework that informed the optimal arrangement of electrodes on a new paddle lead and guided its neurosurgical positioning. We also developed software supporting the rapid configuration of activity-specific stimulation programs that reproduced the natural activation of motor neurons underlying each activity. We tested these neurotechnologies in three individuals with complete sensorimotor paralysis as part of an ongoing clinical trial ( www.clinicaltrials.gov identifier NCT02936453). Within a single day, activity-specific stimulation programs enabled these three individuals to stand, walk, cycle, swim and control trunk movements. Neurorehabilitation mediated sufficient improvement to restore these activities in community settings, opening a realistic path to support everyday mobility with EES in people with SCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“However, this recovery required wearable motion sensors to detect motor intentions from residual movements or compensatory strategies to initiate the preprogrammed stimulation sequences5.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“He had previously participated in the STIMO clinical trial (clinicaltrials.gov, NCT02936453), which involved a five-month neurorehabilitation programme supported by targeted epidural electrical stimulation of the spinal cord4,5.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The delivery of epidural electrical stimulation over the lumbar spinal cord has enabled many individuals with spinal cord injury to regain adaptive control over the activity of otherwise paralysed muscles.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“First, the physiological principles underlying targeted epidural electrical stimulation of the spinal cord have now been validated in nine out nine treated individuals with incomplete4 and complete5 injuries6.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In turn, recruiting these dorsal root entry zones with preprogrammed spatiotemporal sequences replicates the physiological activation of leg motor pools underlying standing and walking4,5,11,13,14.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“In turn, optimized configurations of anodes and cathodes can steer electric fields towards specific subsets of dorsal root entry zones to modulate well-defined ensembles of motor neuron pools5,9,25.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“This programme enabled him to regain the ability to step with the help of a front-wheel walker.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“Indeed, we were able to configure stimulation programs that restored stepping within one day in three participants with complete sensorimotor paralysis5.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“This recovery has been documented in various independent studies, including in participants with complete sensorimotor paralysis5,6,30–34.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [5]
In the citing paper
“The last three participants were implanted with a new paddle lead that was specifically developed to target the dorsal roots involved in the control of trunk and leg movements18 (ONWARD Medical).”
From The neurons that restore walking after paralysis (2022) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
Behzadi, Y., Restom, K., Liau, J., & Liu, T. T. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.042 · Cited by 4,502
Methods to detect, characterize, and remove motion artifact in resting state fMRI
Power, J. D., Mitra, A., Laumann, T. O., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.048 · Cited by 3,748
Temporal Autocorrelation in Univariate Linear Modeling of FMRI Data
Woolrich, M. W., Ripley, B. D., Brady, M., & Smith, S. M. (2001) · NeuroImage · doi:10.1006/nimg.2001.0931 · Cited by 2,859
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Harkema, S., Gerasimenko, Y., Hodes, J., Burdick, J., Angeli, C., Chen, Y., Ferreira, C., Willhite, A., Rejc, E., Grossman, R. G., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60547-3 · Cited by 1,229
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
Self-citationElectronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Self-citationKinaesthetic role of muscle afferents in man, studied by tendon vibration and microneurography
Roll, J., & Vedel, J. (1982) · Experimental Brain Research · doi:10.1007/bf00239377 · Cited by 1,025
Cited by
Sorted by citations
Spinal cord injury: molecular mechanisms and therapeutic interventions
Hu, X., Xu, W., Ren, Y., Wang, Z., He, X., Huang, R., Ma, B., Zhao, J., Zhu, R., & Cheng, L. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01477-6 · Cited by 840
Walking naturally after spinal cord injury using a brain–spine interface
Lorach, H., Galvez, A., Spagnolo, V., Martel, F., Karakas, S., Intering, N., Vat, M., Faivre, O., Harte, C., Komi, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06094-5 · Cited by 631
Self-citationHe, X., Li, Y., Deng, B., Lin, A., Zhang, G., Ma, M., Wang, Y., Yang, Y., & Kang, X. (2022) · Cell Proliferation · doi:10.1111/cpr.13275 · Cited by 347
The neurons that restore walking after paralysis
Kathe, C., Skinnider, M. A., Hutson, T. H., Regazzi, N., Gautier, M., Demesmaeker, R., Komi, S., Ceto, S., James, N. D., Cho, N., et al. (2022) · Nature · doi:10.1038/s41586-022-05385-7 · Cited by 304
“…a surgically implanted neurostimulator interfaced to a multi-electrode paddle lead that enables closed-loop control of biomimetic EES protocols 1,2,18 , and overground neurorehabilitation supported in a multidirectional robotic support system 1,22 (Fig. showing the transitioning from sitting to…”
MethodSelf-citationEpidural stimulation of the cervical spinal cord for post-stroke upper-limb paresis
Powell, M. P., Verma, N., Sorensen, E., Carranza, E., Boos, A., Fields, D. P., Roy, S., Ensel, S., Barra, B., Balzer, J. R., et al. (2023) · Nature Medicine · doi:10.1038/s41591-022-02202-6 · Cited by 220
“Given the short duration of our study compared to similar works in SCI 22,52 we did not expect to observe restorative effects.”
Self-citation
Metadata
- Authors
- Rowald, A., Komi, S., Demesmaeker, R., Baaklini, E., Hernandez-Charpak, S. D., Paoles, E., Montanaro, H., Cassara, A., Becce, F., Lloyd, B., Newton, T., Ravier, J., Kinany, N., D’Ercole, M., Paley, A., Hankov, N., Varescon, C., McCracken, L., Vat, M., Caban, M., Watrin, A., Jacquet, C., Bole-Feysot, L., Harte, C., Lorach, H., Galvez, A., Tschopp, M., Herrmann, N., Wacker, M., Geernaert, L., Fodor, I., Radevich, V., Van Den Keybus, K., Eberle, G., Pralong, E., Roulet, M., Ledoux, J.-B., Fornari, E., Mandija, S., Mattera, L., Martuzzi, R., Nazarian, B., Benkler, S., Callegari, S., Greiner, N., Fuhrer, B., Froeling, M., Buse, N., Denison, T., Buschman, R., Wende, C., Ganty, D., Bakker, J., Delattre, V., Lambert, H., Minassian, K., van den Berg, C. A. T., Kavounoudias, A., Micera, S., Van De Ville, D., Barraud, Q., Kurt, E., Kuster, N., Neufeld, E., Capogrosso, M., Asboth, L., Wagner, F. B., Bloch, J., & Courtine, G.
- Affiliations
- Centre Hospitalier Universitaire Vaudois (CH)
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- Scuola Superiore Sant'Anna (IT)
- École Polytechnique Fédérale de Lausanne (CH)
- University Medical Center Utrecht (NL)
- Centre National de la Recherche Scientifique (FR)
- Medtronic (United States) (US)
- Technical University of Munich (DE)
- Medical University of Vienna (AT)
- Radboud University Medical Center (NL)
- University of Fribourg (CH)
- Corresponding author
- Bloch, Jocelyne
- Courtine, Grégoire
- ORCID
- Rowald, Andreas
- Komi, Salif
- Demesmaeker, Robin
- Baaklini, Edeny
- Hernandez-Charpak, Sergio Daniel
- Montanaro, Hazael
- Cassara, Antonino
- Becce, Fabio
- Lloyd, Bryn
- Newton, Taylor
- Kinany, Nawal
- Hankov, Nicolas
- Varescon, Camille
- McCracken, Laura
- Caban, Miroslav
- Lorach, Henri
- Fodor, Isabelle
- Eberle, Grégoire
- Ledoux, Jean-Baptiste
- Fornari, Eleonora
- Mandija, Stefano
- Martuzzi, Roberto
- Nazarian, Bruno
- Callegari, Simone
- Greiner, Nathan
- Fuhrer, Benjamin
- Froeling, Martijn
- Buschman, Rik
- Minassian, Karen
- Kavounoudias, Anne
- Micera, Silvestro
- Van De Ville, Dimitri
- Barraud, Quentin
- Kurt, Erkan
- Kuster, Niels
- Neufeld, Esra
- Capogrosso, Marco
- Asboth, Leonie
- Wagner, Fabien B.
- Bloch, Jocelyne
- Courtine, Grégoire
- Venue
- Nature Medicine
- Published
- 2022-02
- Volume
- 28
- Issue
- 2
- Pages
- 260-271
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W4210917455
- Cited by
- 455
- References
- 72
- Citations by year
- 2026: 83 · 2025: 113 · 2024: 94 · 2023: 93 · 2022: 72
- FWCI
- 62.99
- Type
- journal article
- Language
- en
- Open access
- green
- dspace.library.uu.nl
- Licence
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- IRIS (submittedVersion)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- epidural stimulation, spinal cord injury, complete paralysis, dorsal root stimulation, neurorehabilitation, swimming, standing
- MeSH terms
- Humans, Leg, Paralysis, Spinal Cord, Spinal Cord Injuries, Walking, Spinal Cord Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review