Kilohertz frame-rate two-photon tomography
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Point-scanning two-photon microscopy enables high-resolution imaging within scattering specimens such as the mammalian brain, but sequential acquisition of voxels fundamentally limits its speed. We developed a two-photon imaging technique that scans lines of excitation across a focal plane at multiple angles and computationally recovers high-resolution images, attaining voxel rates of over 1 billion Hz in structured samples. Using a static image as a prior for recording neural activity, we imaged visually evoked and spontaneous glutamate release across hundreds of dendritic spines in mice at depths over 250 µm and frame rates over 1 kHz. Dendritic glutamate transients in anesthetized mice are synchronized within spatially contiguous domains spanning tens of micrometers at frequencies ranging from 1–100 Hz. We demonstrate millisecond-resolved recordings of acetylcholine and voltage indicators, three-dimensional single-particle tracking and imaging in densely labeled cortex. Our method surpasses limits on the speed of raster-scanned imaging imposed by fluorescence lifetime. A two-photon computed tomography approach, called scanned line angular projection microscopy, enables high-speed imaging at over 1 kHz frame rates, as demonstrated for glutamate imaging in the in vivo mouse brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Dynamic Programming Algorithm Optimization for Spoken Word Recognition
Sakoe, H., & Chiba, S. (1978) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1978.1163055 · Cited by 6,727
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Self-citationBayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
The restricted isometry property and its implications for compressed sensing
Candès, E. J. (2008) · Comptes Rendus. Mathématique · doi:10.1016/j.crma.2008.03.014 · Cited by 3,686
Voltage-dependent block by Mg2+ of NMDA responses in spinal cord neurones
Mayer, M. L., Westbrook, G. L., & Guthrie, P. B. (1984) · Nature · doi:10.1038/309261a0 · Cited by 2,893
Relationship between Absorption Intensity and Fluorescence Lifetime of Molecules
Strickler, S. J., & Berg, R. A. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1733166 · Cited by 2,481
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Self-citation
Cited by
Illuminating dendritic function with computational models
Poirazi, P., & Papoutsi, A. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-020-0301-7 · Cited by 292
Molecular Fluorophores for Deep-Tissue Bioimaging
Wang, S., Li, B., & Zhang, F. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00544 · Cited by 270
Kilohertz two-photon fluorescence microscopy imaging of neural activity in vivo
Wu, J., Liang, Y., Chen, S., Hsu, C.-L., Chavarha, M., Evans, S. W., Shi, D., Lin, M. Z., Tsia, K. K., & Ji, N. (2020) · Nature Methods · doi:10.1038/s41592-020-0762-7 · Cited by 242
Demas, J., Manley, J., Tejera, F., Barber, K., Kim, H., Traub, F. M., Chen, B., & Vaziri, A. (2021) · Nature Methods · doi:10.1038/s41592-021-01239-8 · Cited by 233
An expanded palette of dopamine sensors for multiplex imaging in vivo
Patriarchi, T., Mohebi, A., Sun, J., Marley, A., Liang, R., Dong, C., Puhger, K., Mizuno, G. O., Davis, C. M., Wiltgen, B., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-0936-3 · Cited by 208
Imaging neurotransmitter and neuromodulator dynamics in vivo with genetically encoded indicators
Sabatini, B. L., & Tian, L. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.036 · Cited by 203
Aggarwal, A., Liu, R., Chen, Y., Ralowicz, A. J., Bergerson, S. J., Tomaska, F., Mohar, B., Hanson, T. L., Hasseman, J. P., Reep, D., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-01863-6 · Cited by 185
“6 micrometers in visual cortex in vivo (18), corresponding to a volume containing roughly 30 glutamatergic synapses (1,2).”
BackgroundMethodInfluentialSelf-citationFunctional clustering of dendritic activity during decision-making
Kerlin, A., Mohar, B., Flickinger, D., MacLennan, B. J., Dean, M. B., Davis, C., Spruston, N., & Svoboda, K. (2019) · eLife · doi:10.7554/elife.46966 · Cited by 175
Self-citationMultiphoton fluorescence microscopy for in vivo imaging
Xu, C., Nedergaard, M., Fowell, D. J., Friedl, P., & Ji, N. (2024) · Cell · doi:10.1016/j.cell.2024.07.036 · Cited by 165
Fluorescence imaging of large-scale neural ensemble dynamics
Kim, T. H., & Schnitzer, M. J. (2022) · Cell · doi:10.1016/j.cell.2021.12.007 · Cited by 159
“By sweeping 4 lines of laser illumination in a horizontal plane, with the line orientations spaced at 45 intervals, one study reconstructed neurotransmitter release dynamics along cortical dendrites at a 1 kHz frame-acquisition rate over a 250-mm-wide FOV (Figure 5F) (Kazemipour et al., 2019).”
Live-cell imaging powered by computation
Shroff, H., Testa, I., Jug, F., & Manley, S. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00702-6 · Cited by 75
“…from different microscopes 63 — enabling, for example, kiloHertz activity imaging of acetylcholine and voltage deep in mouse brain with rapid line-scanned multiphoton tomography after first acquiring a static high-resolution volume with traditional raster-scanned multiphoton microscopy 64 .”
Metadata
- Authors
- Kazemipour, A., Novak, O., Flickinger, D., Marvin, J. S., Abdelfattah, A. S., King, J., Borden, P. M., Kim, J. J., Al-Abdullatif, S. H., Deal, P. E., Miller, E. W., Schreiter, E. R., Druckmann, S., Svoboda, K., Looger, L. L., & Podgorski, K.
- Venue
- Nature Methods
- Published
- 2019-07-29
- Volume
- 16
- Issue
- 8
- Pages
- 778-786
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2965378607
- Cited by
- 165
- References
- 71
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.