The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Parallel cryo electron tomography on in situ lamellae
Open accessAbstract
The parallel cryo electron tomography (PACE-tomo) method increases the throughput on in situ samples by parallelizing acquisition. It maximizes the usable sample area on individual lamellae without compromising data quality. In situ cryo electron tomography of cryo focused ion beam milled samples has emerged in recent years as a powerful technique for structural studies of macromolecular complexes in their native cellular environment. However, the possibilities for recording tomographic tilt series in a high-throughput manner are limited, in part by the lamella-shaped samples. Here we utilize a geometrical sample model and optical image shift to record tens of tilt series in parallel, thereby saving time and gaining access to sample areas conventionally used for tracking specimen movement. The parallel cryo electron tomography (PACE-tomo) method achieves a throughput faster than 5 min per tilt series and allows for the collection of sample areas that were previously unreachable, thus maximizing the amount of data from each lamella. Performance testing with ribosomes in vitro and in situ on state-of-the-art and general-purpose microscopes demonstrated the high throughput and quality of PACE-tomo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SciPy 1.0: fundamental algorithms for scientific computing in Python
Virtanen, P., Gommers, R., Oliphant, T. E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W., Bright, J., et al. (2020) · Nature Methods · doi:10.1038/s41592-019-0686-2 · Cited by 38,430
Harris, C. R., Millman, K. J., van der Walt, S. J., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2649-2 · Cited by 23,826
Harris, C., Millman, K., van der Walt, S., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N., et al. (2020) · RePEc: Research Papers in Economics · Cited by 17,844
SciPy 1.0: fundamental algorithms for scientific computing in Python
Virtanen, P., Gommers, R., Oliphant, T. E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W., Bright, J., et al. (2019) · Apollo - University of Cambridge Repository · doi:10.17863/cam.64134 · Cited by 10,460
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
Automated electron microscope tomography using robust prediction of specimen movements
Mastronarde, D. N. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.07.007 · Cited by 5,336
UCSF ChimeraX: Meeting modern challenges in visualization and analysis
Goddard, T. D., Huang, C. C., Meng, E. C., Pettersen, E. F., Couch, G. S., Morris, J. H., & Ferrin, T. E. (2018) · Protein Science · doi:10.1002/pro.3235 · Cited by 5,267
CTFFIND4: Fast and accurate defocus estimation from electron micrographs
Rohou, A., & Grigorieff, N. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.08.008 · Cited by 4,913
New tools for automated high-resolution cryo-EM structure determination in RELION-3
Zivanov, J., Nakane, T., Forsberg, B. O., Kimanius, D., Hagen, W. J., Lindahl, E., & Scheres, S. H. (2018) · eLife · doi:10.7554/elife.42166 · Cited by 4,621
Gctf: Real-time CTF determination and correction
Zhang, K. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.11.003 · Cited by 3,537
Cited by
The molecular architecture of the nuclear basket
(2024) · doi:10.1016/j.cell.2024.07.020 · Cited by 94
Cryo-electron tomography pipeline for plasma membranes
Sun, W. W., Michalak, D. J., Sochacki, K. A., Kunamaneni, P., Alfonzo-Méndez, M. A., Arnold, A. M., Strub, M.-P., Hinshaw, J. E., & Taraska, J. W. (2025) · Nature Communications · doi:10.1038/s41467-025-56045-z · Cited by 35
Molecular architecture of synaptic vesicles
Kravčenko, U., Ruwolt, M., Kroll, J., Yushkevich, A., Zenkner, M., Ruta, J., Lotfy, R., Wanker, E. E., Rosenmund, C., Liu, F., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2407375121 · Cited by 33
Wimmer, B. H., Moraïs, S., Amit, I., Tovar-Herrera, O., Tatli, M., Trautwein-Schult, A., Pfister, B., Zalk, R., Tödtli, P., Simoni, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-65800-1 · Cited by 15
The filamentous ultrastructure of the PopZ condensate is required for its cellular function
Scholl, D., Boyd, T., Latham, A. P., Salazar, A., Khan, A. M. A. M., Boeynaems, S., Holehouse, A. S., Lander, G. C., Sali, A., Park, D., et al. (2026) · Nature Structural & Molecular Biology · doi:10.1038/s41594-025-01742-y · Cited by 14
Metadata
- Authors
- Eisenstein, F., Yanagisawa, H., Kashihara, H., Kikkawa, M., Tsukita, S., & Danev, R.
- Venue
- Nature Methods
- Published
- 2022-12-01
- Volume
- 20
- Issue
- 1
- Pages
- 131-138
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W4310596742
- Cited by
- 257
- References
- 62
- FWCI
- 21.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parallel cryo electron tomography on in situ lamellae. https://app.cochat.ai/papers/10.1038/s41592-022-01690-1
- The paper
- Eisenstein, F., Yanagisawa, H., Kashihara, H., Kikkawa, M., Tsukita, S., & Danev, R. (2023). Parallel cryo electron tomography on in situ lamellae. Nature Methods. https://doi.org/10.1038/s41592-022-01690-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.