Parallel cryo electron tomography on in situ lamellae
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The parallel cryo electron tomography (PACE-tomo) method increases the throughput on in situ samples by parallelizing acquisition. It maximizes the usable sample area on individual lamellae without compromising data quality. In situ cryo electron tomography of cryo focused ion beam milled samples has emerged in recent years as a powerful technique for structural studies of macromolecular complexes in their native cellular environment. However, the possibilities for recording tomographic tilt series in a high-throughput manner are limited, in part by the lamella-shaped samples. Here we utilize a geometrical sample model and optical image shift to record tens of tilt series in parallel, thereby saving time and gaining access to sample areas conventionally used for tracking specimen movement. The parallel cryo electron tomography (PACE-tomo) method achieves a throughput faster than 5 min per tilt series and allows for the collection of sample areas that were previously unreachable, thus maximizing the amount of data from each lamella. Performance testing with ribosomes in vitro and in situ on state-of-the-art and general-purpose microscopes demonstrated the high throughput and quality of PACE-tomo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SciPy 1.0: fundamental algorithms for scientific computing in Python
Virtanen, P., Gommers, R., Oliphant, T. E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W., Bright, J., et al. (2020) · Nature Methods · doi:10.1038/s41592-019-0686-2 · Cited by 38,430
Harris, C. R., Millman, K. J., van der Walt, S. J., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2649-2 · Cited by 23,826
Harris, C., Millman, K., van der Walt, S., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N., et al. (2020) · RePEc: Research Papers in Economics · Cited by 17,844
SciPy 1.0: fundamental algorithms for scientific computing in Python
Virtanen, P., Gommers, R., Oliphant, T. E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W., Bright, J., et al. (2019) · Apollo - University of Cambridge Repository · doi:10.17863/cam.64134 · Cited by 10,460
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
Automated electron microscope tomography using robust prediction of specimen movements
Mastronarde, D. N. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.07.007 · Cited by 5,336
UCSF ChimeraX: Meeting modern challenges in visualization and analysis
Goddard, T. D., Huang, C. C., Meng, E. C., Pettersen, E. F., Couch, G. S., Morris, J. H., & Ferrin, T. E. (2018) · Protein Science · doi:10.1002/pro.3235 · Cited by 5,267
CTFFIND4: Fast and accurate defocus estimation from electron micrographs
Rohou, A., & Grigorieff, N. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.08.008 · Cited by 4,913
New tools for automated high-resolution cryo-EM structure determination in RELION-3
Zivanov, J., Nakane, T., Forsberg, B. O., Kimanius, D., Hagen, W. J., Lindahl, E., & Scheres, S. H. (2018) · eLife · doi:10.7554/elife.42166 · Cited by 4,621
Gctf: Real-time CTF determination and correction
Zhang, K. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.11.003 · Cited by 3,537
SPHIRE-crYOLO is a fast and accurate fully automated particle picker for cryo-EM
Wagner, T., Merino, F., Stabrin, M., Moriya, T., Antoni, C., Apelbaum, A., Hagel, P., Sitsel, O., Raisch, T., Prumbaum, D., et al. (2019) · Communications Biology · doi:10.1038/s42003-019-0437-z · Cited by 1,282
New tools for automated cryo-EM single-particle analysis in RELION-4.0
Kimanius, D., Dong, L., Sharov, G., Nakane, T., & Scheres, S. H. W. (2021) · Biochemical Journal · doi:10.1042/bcj20210708 · Cited by 1,086
The Molecular Architecture of Axonemes Revealed by Cryoelectron Tomography
Nicastro, D., Schwartz, C., Pierson, J., Gaudette, R., Porter, M. E., & McIntosh, J. R. (2006) · Science · doi:10.1126/science.1128618 · Cited by 879
Hagen, W. J. H., Wan, W., & Briggs, J. A. G. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.06.007 · Cited by 806
Visualizing the molecular sociology at the HeLa cell nuclear periphery
Mahamid, J., Pfeffer, S., Schaffer, M., Villa, E., Danev, R., Kuhn Cuellar, L., Förster, F., Hyman, A. A., Plitzko, J. M., & Baumeister, W. (2016) · Science · doi:10.1126/science.aad8857 · Cited by 576
Self-citationFocused-ion-beam thinning of frozen-hydrated biological specimens for cryo-electron microscopy
Marko, M., Hsieh, C., Schalek, R., Frank, J., & Mannella, C. (2007) · Nature Methods · doi:10.1038/nmeth1014 · Cited by 539
Castaño-Díez, D., Kudryashev, M., Arheit, M., & Stahlberg, H. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.017 · Cited by 509
Multi-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells
Tegunov, D., Xue, L., Dienemann, C., Cramer, P., & Mahamid, J. (2021) · Nature Methods · doi:10.1038/s41592-020-01054-7 · Cited by 509
Software tools for automated transmission electron microscopy
Schorb, M., Haberbosch, I., Hagen, W. J. H., Schwab, Y., & Mastronarde, D. N. (2019) · Nature Methods · doi:10.1038/s41592-019-0396-9 · Cited by 504
Focused ion beam micromachining of eukaryotic cells for cryoelectron tomography
Rigort, A., Bäuerlein, F. J. B., Villa, E., Eibauer, M., Laugks, T., Baumeister, W., & Plitzko, J. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201333109 · Cited by 430
An atomic model of HIV-1 capsid-SP1 reveals structures regulating assembly and maturation
Schur, F. K. M., Obr, M., Hagen, W. J. H., Wan, W., Jakobi, A. J., Kirkpatrick, J. M., Sachse, C., Kräusslich, H.-G., & Briggs, J. A. G. (2016) · Science · doi:10.1126/science.aaf9620 · Cited by 415
A Bayesian approach to single-particle electron cryo-tomography in RELION-4.0
Zivanov, J., Otón, J., Ke, Z., von Kügelgen, A., Pyle, E., Qu, K., Morado, D., Castaño-Díez, D., Zanetti, G., Bharat, T. A., et al. (2022) · eLife · doi:10.7554/elife.83724 · Cited by 339
Zheng, S., Wolff, G., Greenan, G., Chen, Z., Faas, F. G. A., Bárcena, M., Koster, A. J., Cheng, Y., & Agard, D. A. (2022) · Journal of Structural Biology: X · doi:10.1016/j.yjsbx.2022.100068 · Cited by 327
Schaffer, M., Mahamid, J., Engel, B. D., Laugks, T., Baumeister, W., & Plitzko, J. M. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.07.010 · Cited by 260
Schaffer, M., Pfeffer, S., Mahamid, J., Kleindiek, S., Laugks, T., Albert, S., Engel, B. D., Rummel, A., Smith, A. J., Baumeister, W., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0497-5 · Cited by 257
A complete data processing workflow for cryo-ET and subtomogram averaging
Chen, M., Bell, J. M., Shi, X., Sun, S. Y., Wang, Z., & Ludtke, S. J. (2019) · Nature Methods · doi:10.1038/s41592-019-0591-8 · Cited by 253
Cryo-EM structure of a human cytoplasmic actomyosin complex at near-atomic resolution
Ecken, J. V. D., Heissler, S. M., Pathan-Chhatbar, S., Manstein, D. J., & Raunser, S. (2016) · Nature · doi:10.1038/nature18295 · Cited by 245
Clustering and variance maps for cryo-electron tomography using wedge-masked differences
Heumann, J. M., Hoenger, A., & Mastronarde, D. N. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.05.011 · Cited by 220
Rigort, A., Günther, D., Hegerl, R., Baum, D., Weber, B., Prohaska, S., Medalia, O., Baumeister, W., & Hege, H.-C. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.08.012 · Cited by 213
Cryo-CARE: Content-Aware Image Restoration for Cryo-Transmission Electron Microscopy Data
Buchholz, T.-O., Jordan, M., Pigino, G., & Jug, F. (2019) · 2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019) · doi:10.1109/isbi.2019.8759519 · Cited by 183
Content-aware image restoration for electron microscopy
Buchholz, T.-O., Krull, A., Shahidi, R., Pigino, G., Jékely, G., & Jug, F. (2019) · Methods in Cell Biology · doi:10.1016/bs.mcb.2019.05.001 · Cited by 182
Fialka, I., Schwarz, H., Reichmann, E., Oft, M., Busslinger, M., & Beug, H. (1996) · The Journal of cell biology · doi:10.1083/jcb.132.6.1115 · Cited by 168
Structural basis for VIPP1 oligomerization and maintenance of thylakoid membrane integrity
Gupta, T. K., Klumpe, S., Gries, K., Heinz, S., Wietrzyñski, W., Ohnishi, N., Niemeyer, J., Spaniol, B., Schaffer, M., Rast, A., et al. (2021) · Cell · doi:10.1016/j.cell.2021.05.011 · Cited by 166
Dissecting the molecular organization of the translocon-associated protein complex
Pfeffer, S., Dudek, J., Schaffer, M., Ng, B. G., Albert, S., Plitzko, J. M., Baumeister, W., Zimmermann, R., Freeze, H. H., Engel, B. D., et al. (2017) · Nature Communications · doi:10.1038/ncomms14516 · Cited by 163
A modular platform for automated cryo-FIB workflows
Klumpe, S., Fung, H. K. H., Goetz, S. K., Zagoriy, I., Hampoelz, B., Zhang, X., Erdmann, P. S., Baumbach, J., Müller, C. W., Beck, M., et al. (2021) · eLife · doi:10.7554/elife.70506 · Cited by 163
Wu, C., Huang, X., Cheng, J., Zhu, D., & Zhang, X. (2019) · Journal of Structural Biology · doi:10.1016/j.jsb.2019.09.013 · Cited by 147
High resolution single particle cryo-electron microscopy using beam-image shift
Cheng, A., Eng, E. T., Alink, L. M., Rice, W. J., Jordan, K. D., Kim, L. Y., Potter, C. S., & Carragher, B. O. (2018) · Journal of Structural Biology · doi:10.1016/j.jsb.2018.07.015 · Cited by 136
Fully automated, sequential focused ion beam milling for cryo-electron tomography
Zachs, T., Schertel, A., Medeiros, J. M., Weiss, G. L., Hugener, J., Matos, J., & Pilhofer, M. (2020) · eLife · doi:10.7554/elife.52286 · Cited by 132
Structures from intact myofibrils reveal mechanism of thin filament regulation through nebulin
Wang, Z., Grange, M., Pospich, S., Wagner, T., Kho, A. L., Gautel, M., & Raunser, S. (2022) · Science · doi:10.1126/science.abn1934 · Cited by 125
An improved strategy for automated electron microscopic tomography
Zheng, Q. S., Braunfeld, M. B., Sedat, J. W., & Agard, D. A. (2004) · Journal of Structural Biology · doi:10.1016/j.jsb.2004.02.005 · Cited by 120
Mind the gap: Micro-expansion joints drastically decrease the bending of FIB-milled cryo-lamellae
Wolff, G., Limpens, R. W. A. L., Zheng, S., Snijder, E. J., Agard, D. A., Koster, A. J., & Bárcena, M. (2019) · Journal of Structural Biology · doi:10.1016/j.jsb.2019.09.006 · Cited by 115
Bouvette, J., Liu, H.-F., Du, X., Zhou, Y., Sikkema, A. P., Mello, J. D. F. R. E., Klemm, B. P., Huang, R. K., Schaaper, R. M., Borgnia, M. J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22251-8 · Cited by 115
Automated cryo-lamella preparation for high-throughput in-situ structural biology
Buckley, G. A., Gervinskas, G., Taveneau, C., Venugopal, H., Whisstock, J. C., & de Marco, A. (2020) · Journal of Structural Biology · doi:10.1016/j.jsb.2020.107488 · Cited by 111
A streamlined workflow for automated cryo focused ion beam milling
Tacke, S., Erdmann, P. S., Wang, Z., Klumpe, S., Grange, M., Plitzko, J. M., & Raunser, S. (2021) · Journal of Structural Biology · doi:10.1016/j.jsb.2021.107743 · Cited by 108
MASTRONARDE, D. N. (2008) · Journal of Microscopy · doi:10.1111/j.1365-2818.2008.01977.x · Cited by 106
Direct visualization of degradation microcompartments at the ER membrane
Albert, S., Wietrzyñski, W., Lee, C., Schaffer, M., Beck, F., Schuller, J. M., Salomé, P. A., Plitzko, J. M., Baumeister, W. P., & Engel, B. D. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1905641117 · Cited by 103
Ni, T., Frosio, T., Mendonça, L., Sheng, Y., Clare, D. K., Himes, B. A., & Zhang, P. (2022) · Nature Protocols · doi:10.1038/s41596-021-00648-5 · Cited by 101
Ederth, J., Mandava, C. S., Dasgupta, S., & Sanyal, S. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn992 · Cited by 93
Challenges and triumphs in cryo-electron tomography
Hylton, R. K., & Swulius, M. T. (2021) · iScience · doi:10.1016/j.isci.2021.102959 · Cited by 80
Subtomogram analysis using the Volta phase plate
Khoshouei, M., Pfeffer, S., Baumeister, W. P., Förster, F. G., & Danev, R. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.05.009 · Cited by 76
Self-citationRoutine sub-2.5 Å cryo-EM structure determination of GPCRs
Danev, R., Belousoff, M. J., Liang, Y.-L., Zhang, X., Eisenstein, F., Wootten, D. L., & Sexton, P. M. (2021) · Nature Communications · doi:10.1038/s41467-021-24650-3 · Cited by 76
Self-citationMedeiros, J. M., Böck, D., Weiss, G. L., Kooger, R., Wepf, R. A., & Pilhofer, M. (2018) · Ultramicroscopy · doi:10.1016/j.ultramic.2018.04.002 · Cited by 75
A flexible framework for multi-particle refinement in cryo-electron tomography
Burt, A., Gaifas, L., Dendooven, T., & Gutsche, I. (2021) · PLOS Biology · doi:10.1371/journal.pbio.3001319 · Cited by 66
Correlative montage parallel array cryo-tomography for in situ structural cell biology
Yang, J. E., Larson, M., Sibert, B. S., Kim, J. Y., Parrell, D., Sanchez, J. C., Pappas, V., Kumar, A., Cai, K., Thompson, K., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-01999-5 · Cited by 62
Combining high throughput and high quality for cryo-electron microscopy data collection
Weis, F., & Hagen, W. J. H. (2020) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798320008347 · Cited by 59
Multishot tomography for high-resolution in situ subtomogram averaging
Khavnekar, S., Wan, W., Majumder, P., Wietrzyñski, W., Erdmann, P. S., & Plitzko, J. M. (2022) · Journal of Structural Biology · doi:10.1016/j.jsb.2022.107911 · Cited by 59
Montage electron tomography of vitrified specimens
Peck, A., Carter, S. D., Mai, H., Chen, S., Burt, A., & Jensen, G. J. (2022) · Journal of Structural Biology · doi:10.1016/j.jsb.2022.107860 · Cited by 57
Structure of a thylakoid-anchored contractile injection system in multicellular cyanobacteria
Weiss, G. L., Eisenstein, F., Kieninger, A.-K., Xu, J., Minas, H. A., Gerber, M., Feldmüller, M., Maldener, I., Forchhammer, K., & Pilhofer, M. (2022) · Nature Microbiology · doi:10.1038/s41564-021-01055-y · Cited by 46
Self-citationAn overview of the recent advances in cryo-electron microscopy for life sciences
Assaiya, A., Burada, A. P., Dhingra, S., & Kumar, J. (2021) · Emerging Topics in Life Sciences · doi:10.1042/etls20200295 · Cited by 39
Structural basis for VIPP1 oligomerization and maintenance of thylakoid membrane integrityPreprint
Gupta, T. K., Klumpe, S., Gries, K., et al. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.08.11.243204 · Cited by 22
Optimizing Cryo-FIB Lamellas for sub-5Å in situ Structural BiologyPreprint
Khavnekar, S., Vrbovská, V., Zaoralová, M., Kelley, R., Beck, F., Klumpe, S., Kotecha, A., Plitzko, J. M., & Erdmann, P. S. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.16.496417 · Cited by 16
Tools enabling flexible approaches to high-resolution subtomogram averagingPreprint
Burt, A., Gaifas, L., Dendooven, T., & Gutsche, I. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.01.31.428990 · Cited by 9
Cited by
The molecular architecture of the nuclear basket
(2024) · doi:10.1016/j.cell.2024.07.020 · Cited by 94
Cryo-electron tomography pipeline for plasma membranes
Sun, W. W., Michalak, D. J., Sochacki, K. A., Kunamaneni, P., Alfonzo-Méndez, M. A., Arnold, A. M., Strub, M.-P., Hinshaw, J. E., & Taraska, J. W. (2025) · Nature Communications · doi:10.1038/s41467-025-56045-z · Cited by 35
“However, tomograms of unroofed cells exhibit particular advantages for STA efforts because decreased cytosolic crowding makes protein shape and position more distinct and, coupled with the lack of FIB radiation damage 48 , enhances the potential for high-resolution STA. Sites of arrested clathrin-mediated endocytosis…”
InfluentialMolecular architecture of synaptic vesicles
Kravčenko, U., Ruwolt, M., Kroll, J., Yushkevich, A., Zenkner, M., Ruta, J., Lotfy, R., Wanker, E. E., Rosenmund, C., Liu, F., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2407375121 · Cited by 33
Wimmer, B. H., Moraïs, S., Amit, I., Tovar-Herrera, O., Tatli, M., Trautwein-Schult, A., Pfister, B., Zalk, R., Tödtli, P., Simoni, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-65800-1 · Cited by 15
Wimmer, B. H., Moraïs, S., Amit, I., Tovar-Herrera, O., Tatli, M., Trautwein-Schult, A., Tödtli, P., Simoni, S., Lisibach, M., Levin, L., et al. (2025) · doi:10.1101/2025.03.31.646359 · Cited by 15
Metadata
- Authors
- Eisenstein, F., Yanagisawa, H., Kashihara, H., Kikkawa, M., Tsukita, S., & Danev, R.
- Venue
- Nature Methods
- Published
- 2022-12-01
- Volume
- 20
- Issue
- 1
- Pages
- 131-138
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W4310596742
- Cited by
- 257
- References
- 62
- FWCI
- 21.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.