Abstract
Mass spectrometry imaging (MSI) enables label-free spatial mapping of hundreds of biomolecules in tissue sections. This capability provides valuable information on tissue heterogeneity that is difficult to obtain using population-averaged assays. Despite substantial developments in both instrumentation and methodology, MSI of tissue samples at single-cell resolution remains challenging. Herein, we describe a protocol for robust imaging of tissue sections with a high (better than 10-μm) spatial resolution using nanospray desorption electrospray ionization (nano-DESI) mass spectrometry, an ambient ionization technique that does not require sample pretreatment before analysis. In this protocol, mouse uterine tissue is used as a model system to illustrate both the workflow and data obtained in these experiments. We provide a detailed description of the nano-DESI MSI platform, fabrication of the nano-DESI and shear force probes, shear force microscopy experiments, spectral acquisition, and data processing. A properly trained researcher (e.g., technician, graduate student, or postdoc) can complete all the steps from probe fabrication to data acquisition and processing within a single day. We also describe a new strategy for acquiring both positive- and negative-mode imaging data in the same experiment. This is achieved by alternating between positive and negative data acquisition modes during consecutive line scans. Using our imaging approach, hundreds of high-quality ion images were obtained from a single uterine section. This protocol enables sensitive and quantitative imaging of lipids and metabolites in heterogeneous tissue sections with high spatial resolution, which is critical to understanding biochemical processes occurring in biological tissues. This protocol describes how to achieve high spatial resolution imaging of biological tissues using nanospray desorption electrospray ionization mass spectrometry
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple Female Reproductive Failures in Cyclooxygenase 2–Deficient Mice
Lim, H., Paria, B. C., Das, S. K., Dinchuk, J. E., Langenbach, R., Trzaskos, J. M., & Dey, S. K. (1997) · Cell · doi:10.1016/s0092-8674(00)80402-x · Cited by 1,430
Self-citationRoadmap to embryo implantation: clues from mouse models
Wang, H., & Dey, S. K. (2006) · Nature Reviews Genetics · doi:10.1038/nrg1808 · Cited by 1,298
Self-citationNorris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.505 · Cited by 646
Kompauer, M., Heiles, S., & Spengler, B. (2017) · Nature Methods · doi:10.1038/nmeth.4071 · Cited by 600
Ambient Ionization Mass Spectrometry: Recent Developments and Applications
Feider, C. L., Krieger, A., DeHoog, R. J., & Eberlin, L. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00807 · Cited by 496
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Discovery of a second 15 S -lipoxygenase in humans
Brash, A. R., Boeglin, W. E., & Chang, M. S. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6148 · Cited by 401
Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry
Laskin, J., Heath, B. S., Roach, P. J., Cazares, L., & Semmes, O. J. (2012) · Analytical Chemistry · doi:10.1021/ac2021322 · Cited by 338
Self-citationStoeckli, M., Staab, D., & Schweitzer, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.10.007 · Cited by 295
High-Spatial Resolution Mass Spectrometric Imaging of Peptide and Protein Distributions on a Surface
Luxembourg, S. L., Mize, T. H., McDonnell, L. A., & Heeren, R. M. A. (2004) · Analytical Chemistry · doi:10.1021/ac049692q · Cited by 267
Song, H., Lim, H., Paria, B. C., Matsumoto, H., Swift, L. L., Morrow, J., Bonventre, J. V., & Dey, S. K. (2002) · Development · doi:10.1242/dev.129.12.2879 · Cited by 250
Self-citationWu, C., Ifa, D. R., Manicke, N. E., & Cooks, R. G. (2009) · Analytical Chemistry · doi:10.1021/ac901003u · Cited by 238
Zavalin, A., Todd, E. M., Rawhouser, P. D., Yang, J., Norris, J. L., & Caprioli, R. M. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.3108 · Cited by 236
Vaysse, P.-M., Heeren, R. M. A., Porta, T., & Balluff, B. (2017) · The Analyst · doi:10.1039/c7an00565b · Cited by 215
Zavalin, A., Todd, E. M., Rawhouser, P. D., Yang, J., Norris, J. L., & Caprioli, R. M. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.3132 · Cited by 196
Imaging mass spectrometry: fundamentals and applications to drug discovery
Rubakhin, S. S., Jurchen, J. C., Monroe, E. B., & Sweedler, J. V. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03458-6 · Cited by 190
Zavalin, A., Yang, J., Hayden, K., Vestal, M., & Caprioli, R. M. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8532-6 · Cited by 187
Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques
Laskin, J., & Lanekoff, I. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04188 · Cited by 177
Self-citationBodzon‐Kulakowska, A., & Suder, P. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21468 · Cited by 173
Lanekoff, I., Heath, B. S., Liyu, A. V., Thomas, M., Carson, J. P., & Laskin, J. (2012) · Analytical Chemistry · doi:10.1021/ac301909a · Cited by 162
Self-citationBurnum, K. E., Cornett, D. S., Puolitaival, S. M., Milne, S. B., Myers, D. S., Tranguch, S., Brown, H. A., Dey, S. K., & Caprioli, R. M. (2009) · Journal of Lipid Research · doi:10.1194/jlr.m900100-jlr200 · Cited by 158
Self-citationMass spectrometry imaging for drugs and metabolites
Greer, T., Sturm, R. M., & Li, L. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.03.032 · Cited by 148
Garza, K. Y., Feider, C. L., Klein, D. R., Rosenberg, J. A., Brodbelt, J. S., & Eberlin, L. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00967 · Cited by 138
Imaging mass spectrometry of thin tissue sections: A decade of collective efforts
Chaurand, P. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.005 · Cited by 127
Matrix effects in biological mass spectrometry imaging: identification and compensation
Lanekoff, I., Stevens, S. L., Stenzel‐Poore, M. P., & Laskin, J. (2014) · The Analyst · doi:10.1039/c4an00504j · Cited by 126
Self-citationImaging mass spectrometry: Hype or hope?
Heeren, R. M. A., Smith, D. F., Stauber, J., Kaletaş, B. K., & MacAleese, L. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.01.011 · Cited by 122
Hsu, C.-C., Chou, P.-T., & Zare, R. N. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03389 · Cited by 121
Lanekoff, I., Thomas, M., Carson, J. P., Smith, J. N., Timchalk, C. A., & Laskin, J. (2012) · Analytical Chemistry · doi:10.1021/ac302308p · Cited by 116
Self-citationBergman, H., Lundin, E., Andersson, M., & Lanekoff, I. (2016) · The Analyst · doi:10.1039/c5an02620b · Cited by 116
Lanekoff, I., Thomas, M., & Laskin, J. (2014) · Analytical Chemistry · doi:10.1021/ac403931r · Cited by 110
Self-citationYin, R., Kyle, J. E., Burnum-Johnson, K., Bloodsworth, K., Sussel, L., Ansong, C. K., & Laskin, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00161 · Cited by 103
Self-citationTian, H., Sparvero, L. J., Blenkinsopp, P., Amoscato, A. A., Watkins, S. C., Bayır, H., Kagan, V. E., & Winograd, N. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201814256 · Cited by 89
Secondary Ion Mass Spectrometry Imaging of Tissues, Cells, and Microbial Systems
Anderton, C., & Gamble, L. J. (2016) · Microscopy Today · doi:10.1017/s1551929516000018 · Cited by 89
Tian, H., Sparvero, L. J., Amoscato, A. A., Bloom, A., Bayır, H., Kagan, V. E., & Winograd, N. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00164 · Cited by 82
High Resolution Tissue Imaging Using the Single-probe Mass Spectrometry under Ambient Conditions
Rao, W., Pan, N., & Yang, Z. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1091-4 · Cited by 81
Nguyen, S., Liyu, A. V., Chu, R., Anderton, C., & Laskin, J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03293 · Cited by 72
Self-citationNguyen, S., Kyle, J. E., Dautel, S. E., Sontag, R. L., Luders, T., CORLEY, R. A., Ansong, C. K., Carson, J. P., & Laskin, J. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02045 · Cited by 68
Self-citationHankin, J. A., & Murphy, R. C. (2010) · Analytical Chemistry · doi:10.1021/ac101079v · Cited by 67
Lanekoff, I., Burnum-Johnson, K., Thomas, M., Cha, J., Dey, S. K., Yang, P., Conaway, M. C. P., & Laskin, J. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8174-0 · Cited by 59
Self-citationKim, J. Y., Seo, E. S., Kim, H., Park, J. W., Lim, D.-K., & Moon, D. W. (2017) · Nature Communications · doi:10.1038/s41467-017-02216-6 · Cited by 56
Oversampling To Improve Spatial Resolution for Liquid Extraction Mass Spectrometry Imaging
Duncan, K. D., & Lanekoff, I. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04687 · Cited by 37
Tian, H., Sparvero, L. J., Blenkinsopp, P., Amoscato, A. A., Watkins, S. C., Bayır, H., Kagan, V. E., & Winograd, N. (2019) · Angewandte Chemie · doi:10.1002/ange.201814256 · Cited by 30
Lanekoff, I., Cha, J., Kyle, J. E., Dey, S. K., Laskin, J., & Burnum-Johnson, K. (2016) · Scientific Reports · doi:10.1038/srep33023 · Cited by 21
Self-citationLanekoff, I., & Laskin, J. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-1357-2_10 · Cited by 19
Self-citation
Cited by
Taylor, M. J., Lukowski, J. K., & Anderton, C. R. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00439 · Cited by 302
Mass spectrometry imaging for spatially resolved multi-omics molecular mapping
Zhang, H., Lu, K. H., Ebbini, M., Huang, P., Lu, H., & Li, L. (2024) · npj Imaging · doi:10.1038/s44303-024-00025-3 · Cited by 173
Proteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202200721 · Cited by 54
Self-citationRegulation of β-cell death by ADP-ribosylhydrolase ARH3 via lipid signaling in insulitis
Sarkar, S., Deiter, C., Kyle, J. E., Guney, M. A., Sarbaugh, D., Yin, R., Li, X., Cui, Y., Ramos-Rodriguez, M., Nicora, C. D., et al. (2024) · Cell Communication and Signaling · doi:10.1186/s12964-023-01437-1 · Cited by 6
Self-citationProteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie · doi:10.1002/ange.202200721 · Cited by 6
Self-citation
Metadata
- Authors
- Yin, R., Burnum-Johnson, K. E., Sun, X., Dey, S. K., & Laskin, J.
- Venue
- Nature Protocols
- Published
- 2019-11-13
- Volume
- 14
- Issue
- 12
- Pages
- 3445-3470
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W2982932823
- Cited by
- 220
- References
- 45
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.