Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

High-density EMG, IMU, kinetic, and kinematic open-source data for comprehensive locomotion activities

Open access

Abstract

Novel sensor technology enables new insights in the neuromechanics of human locomotion that were previously not possible. Here, we provide a dataset of high-density surface electromyography (HDsEMG) and high-resolution inertial measurement unit (IMU) signals, along with motion capture and force data for the lower limb of 10 healthy adults during multiple locomotion modes. The participants performed level-ground and slope walking, as well as stairs ascent/descent, side stepping gait, and stand-to-walk and sit-to-stand-to-walk, at multiple walking speeds. These data can be used for the development and validation of locomotion mode recognition and control algorithms for prosthetics, exoskeletons, and bipedal robots, and for motor control investigations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41597-023-02679-x

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Motion capture laboratory rendering (to scale) with embedded force plates displayed in grey. (A) Ramp setup, where the solid ramp’s incline is 5° and the transparent one (along with the rails) is 15°. Force plates were at the same distance from the beginning of the ramp for both inclines. Force plates on the 15° ramp as well as the rails on one side are not displayed for clarity of illustration. (B) Level ground walking and instrumented stairs setup, where the instrumented stairs (170 mm step height, 410 mm step depth) were removed from the volume when they were not used. Human dummy model courtesy of Gil P. de Paulo37.
Fig. 1 Motion capture laboratory rendering (to scale) with embedded force plates displayed in grey. (A) Ramp setup, where the solid ramp’s incline is 5° and the transparent one (along with the rails) is 15°. Force plates were at the same distance from the beginning of the ramp for both inclines. Force plates on the 15° ramp as well as the rails on one side are not displayed for clarity of illustration. (B) Level ground walking and instrumented stairs setup, where the instrumented stairs (170 mm step height, 410 mm step depth) were removed from the volume when they were not used. Human dummy model courtesy of Gil P. de Paulo37.CC BY · PubMed Central
Fig. 2 Participant instrumentation setup. Reflective markers (in purple) annotated only on the left side (apart from 18 - Sacrum) as the right side is mirrored.
Fig. 2 Participant instrumentation setup. Reflective markers (in purple) annotated only on the left side (apart from 18 - Sacrum) as the right side is mirrored.CC BY · PubMed Central
Fig. 3 Data organization illustrating the folder structure (A) and the structured subject *mat data (B). Right foot gait cycle data has the same structure as the left one illustrated here, with the difference that instead of right foot strike (RFS), left foot-off (LFO), and right foot-off (RFO) timestamps, it contains the left foot strike (LFS), RFO, and LFO, as these are the timestamps of interest during a right foot gait cycle.
Fig. 3 Data organization illustrating the folder structure (A) and the structured subject *mat data (B). Right foot gait cycle data has the same structure as the left one illustrated here, with the difference that instead of right foot strike (RFS), left foot-off (LFO), and right foot-off (RFO) timestamps, it contains the left foot strike (LFS), RFO, and LFO, as these are the timestamps of interest during a right foot gait cycle.CC BY · PubMed Central
Fig. 4 Joint angles and moments during stairs and ramps ambulation. Gait cycle duration normalized between two consecutive heel strikes of the same leg and moments normalized by the respective participant’s body weight. Tiles at the top annotate the ambulation mode.
Fig. 4 Joint angles and moments during stairs and ramps ambulation. Gait cycle duration normalized between two consecutive heel strikes of the same leg and moments normalized by the respective participant’s body weight. Tiles at the top annotate the ambulation mode.CC BY · PubMed Central
Fig. 5 Joint angles and moments during level ground walking. Gait cycle duration normalized between two consecutive heel strikes of the same leg and moments normalized by the respective participant’s body weight. Tiles at the top annotate the walking condition. The sidestepping plots are for the foot that is in stance during sidestepping. The shaded area for the stand-to-walk, sit-to-stand-to-walk, and sidestepping represent the standard deviations for the data due to starting with the left or the right foot or sidestepping to the left or the right.
Fig. 5 Joint angles and moments during level ground walking. Gait cycle duration normalized between two consecutive heel strikes of the same leg and moments normalized by the respective participant’s body weight. Tiles at the top annotate the walking condition. The sidestepping plots are for the foot that is in stance during sidestepping. The shaded area for the stand-to-walk, sit-to-stand-to-walk, and sidestepping represent the standard deviations for the data due to starting with the left or the right foot or sidestepping to the left or the right.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. Gil P. de Paulo. Human 1 A (Jarde Dummy - review). Available at: https://grabcad.com/library/human-1a-jarde-dummy-review-1 (Accessed: 08-Jun-2022) (2020).

Cited by

See all 43

Metadata

Authors
Dimitrov, H., Bull, A. M. J., & Farina, D.
Affiliations
  • MRC Cognition and Brain Sciences Unit (GB)
  • Imperial College London (GB)
Corresponding author
Dimitrov, Hristo
Venue
Scientific Data
Published
2023-11-10
Volume
10
Issue
1
Pages
789-789
ISSN
2052-4463 (ISSN-L)
OpenAlex
W4388567487
Cited by
34
References
36
Citations by year
2026: 13 · 2025: 15 · 2024: 4 · 2023: 2
Type
data paper
Language
en
Open access
Licence
Locations
  • Scientific Data (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Apollo (University of Cambridge) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Research Councils UK (EP/L016737/1)
  • Engineering and Physical Sciences Research Council (EP/J021199/1, 1974772, 810346)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
human locomotion, neuromechanics, surface electromyography, inertial measurement unit, motion capture, slope walking, stair ascent and descent, walking speed, locomotion mode recognition, prosthetics, exoskeleton, biped robot, motor control
MeSH terms
Adult, Biomechanical Phenomena, Electromyography, Gait, Humans, Locomotion, Walking

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-density EMG, IMU, kinetic, and kinematic open-source data for comprehensive locomotion activities. https://app.cochat.ai/papers/10.1038/s41597-023-02679-x
The paper
Dimitrov, H., Bull, A. M. J., & Farina, D. (2023). High-density EMG, IMU, kinetic, and kinematic open-source data for comprehensive locomotion activities. Scientific Data. https://doi.org/10.1038/s41597-023-02679-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.