The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Sonochemical Synthesis of Sulfur Doped Reduced Graphene Oxide Supported CuS Nanoparticles for the Non-Enzymatic Glucose Sensor Applications
Open accessAbstract
Over the present material synthesis routes, the sonochemical route is highly efficient and comfortable way to produce nanostructured materials. In this way, the copper sulfide (CuS-covellite) and sulfur doped reduced graphene oxide (S-rGO) nanocomposite was prepared by sonochemical method. Interestingly, the structure of the as-prepared S-rGO/CuS was changed from the covellite to digenite phase. Herein, the S-rGO was act as a mild oxidizer and liable for the structural transformations. These structural changes are sequentially studied by various physicochemical characterizations such as Fourier transform infrared spectroscopy (FT-IR), Raman spectroscopy, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Transmission electron microscopy (TEM). After scrupulous structural evaluations, the transformation of CuS phase was identified and documented. This oxidized CuS has an excellent electrocatalytic activity when compare to the bulk CuS. This S-rGO/CuS was further used for the determination of glucose and acquired good electrocatalytic performances. This S-rGO/CuS was exhibited a wide linear concentration range, 0.0001–3.88 mM and 3.88–20.17 mM, and a low-level detection limit of 32 nM. Moreover, we have validated the practicability of our developed glucose sensor in real biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Sulfur-Doped Graphene as an Efficient Metal-free Cathode Catalyst for Oxygen Reduction
Yang, Z., Yao, Z., Li, G., Fang, G., Nie, H., Liu, Z., Zhou, X., Chen, X., & Huang, S. (2012) · ACS Nano · doi:10.1021/nn203393d · Cited by 2,138
Paraknowitsch, J. P., & Thomas, A. (2013) · Energy & Environmental Science · doi:10.1039/c3ee41444b · Cited by 1,848
APPLICATIONS OF ULTRASOUND TO MATERIALS CHEMISTRY
Suslick, K. S., & Price, G. J. (1999) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.29.1.295 · Cited by 1,704
Sonochemical synthesis of nanomaterials
Xu, H., Zeiger, B. W., & Suslick, K. S. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35282f · Cited by 1,161
ULTRASOUND: Its Chemical, Physical and Biological Effects
Suslick, K. S., & Nyborg, W. L. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.398864 · Cited by 1,094
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Sun, D., Ban, R., Zhang, P.-H., Wu, G.-H., Zhang, J.-R., & Zhu, J.-J. (2013) · Carbon · doi:10.1016/j.carbon.2013.07.095 · Cited by 857
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Optical methods for sensing glucose
Steiner, M.-S., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 497
An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F. (2008) · The Analyst · doi:10.1039/b712970j · Cited by 481
Nanoelectronic biosensors based on CVD grown graphene
Huang, Y., Dong, X., Shi, Y., Li, C. M., Li, L.-J., & Chen, P. (2010) · Nanoscale · doi:10.1039/c0nr00142b · Cited by 441
Synthesis of CuO nanostructures and their application for nonenzymatic glucose sensing
Wang, X., Hu, C., Liu, H., Du, G., He, X., & Xi, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.09.067 · Cited by 415
Nanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
CuO Nanospheres Based Nonenzymatic Glucose Sensor
Reitz, E., Jia, W., Gentile, M., Wang, Y., & Lei, Y. (2008) · Electroanalysis · doi:10.1002/elan.200804327 · Cited by 346
Vinayan, B. P., Zhao-Karger, Z., Diemant, T., Chakravadhanula, V. S. K., Schwarzburger, N. I., Cambaz, M. A., Behm, R. J., Kübel, C., & Fichtner, M. (2016) · Nanoscale · doi:10.1039/c5nr04383b · Cited by 332
Park, J.-E., Jang, Y. J., Kim, Y. J., Song, M.-S., Yoon, S., Kim, D. H., & Kim, S.-J. (2014) · Phys. Chem. Chem. Phys. · doi:10.1039/c3cp54311k · Cited by 228
Luo, L., Zhu, L., & Wang, Z. (2012) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2012.03.006 · Cited by 226
The structure of amorphous copper sulfide precipitates: An X-ray absorption study
Pattrick, R. A. D., Mosselmans, J. F. W., Charnock, J. M., England, K. E. R., Helz, G. R., Garner, C. D., & Vaughan, D. J. (1997) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(97)00061-6 · Cited by 216
Yang, G., Wan, X., Su, Y., Zeng, X., & Tang, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta05943k · Cited by 188
CuS nanotubes for ultrasensitive nonenzymatic glucose sensors
Zhang, X., Wang, G., Gu, A., Wei, Y., & Fang, B. (2008) · Chemical Communications · doi:10.1039/b814725f · Cited by 158
Dutta, S., Ray, C., Mallick, S., Sarkar, S., Sahoo, R., Negishi, Y., & Pal, T. (2015) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5b08421 · Cited by 155
Oxidation state variations in copper minerals studied with Cu 2p X-ray absorption spectroscopy
van der Laan, G., Pattrick, R. A. D., Henderson, C. M. B., & Vaughan, D. J. (1992) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(92)90037-e · Cited by 151
Enzyme-free amperometric sensing of glucose using Cu-CuO nanowire composites
Wang, G., Yan, W., Zhang, W., Zhang, X., Fang, B., & Wang, L. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0260-1 · Cited by 145
Karikalan, N., Velmurugan, M., Chen, S.-M., & Karuppiah, C. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b07260 · Cited by 138
Self-citationIn situ synthesis of CuS nanotubes on Cu electrode for sensitive nonenzymatic glucose sensor
Qian, L., Mao, J., Tian, X., Yuan, H., & Xiao, D. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.09.076 · Cited by 129
Ni, Y., Jin, L., Zhang, L., & Hong, J. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm00142b · Cited by 111
Myung, Y., Jang, D. M., Cho, Y. J., Kim, H. S., Park, J., Kim, J.-U., Choi, Y., & Lee, C. J. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp806633j · Cited by 101
One-step synthesis of sulfur doped graphene foam for oxygen reduction reactions
Chen, L., Cui, X., Wang, Y., Wang, M., Qiu, R., Shu, Z., Zhang, L., Hua, Z., Cui, F., Wei, C., et al. (2013) · Dalton Transactions · doi:10.1039/c3dt52253a · Cited by 92
Noninvasive Method for Glucose Level Estimation by Saliva
Agrawal, R. P. (2013) · Journal of Diabetes & Metabolism · doi:10.4172/2155-6156.1000266 · Cited by 88
Zhou, X., Nie, H., Yao, Z., Dong, Y., Yang, Z., & Huang, S. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.012 · Cited by 85
Favaro, M., Carraro, F., Cattelan, M., Colazzo, L., Durante, C., Sambi, M., Gennaro, A., Agnoli, S., & Granozzi, G. (2015) · Journal of Materials Chemistry A · doi:10.1039/c5ta01561h · Cited by 67
Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Miller, P. R., Skoog, S. A., Edwards, T. L., Wheeler, D. R., Xiao, X., Brozik, S. M., Polsky, R., & Narayan, R. J. (2012) · Journal of Visualized Experiments · doi:10.3791/4067 · Cited by 40
Lin, J., Tao, F., Wang, L., Chen, L., Ying, Y., Zhang, L., Liu, H., & Xia, M. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7345-2 · Cited by 35
Cited by
Jamkhande, P. G., Ghule, N. W., Bamer, A. H., & Kalaskar, M. G. (2019) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2019.101174 · Cited by 1,666
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Recent progress in the chemical reduction of graphene oxide by green reductants–A Mini review
Kurian, M. (2021) · Carbon Trends · doi:10.1016/j.cartre.2021.100120 · Cited by 85
Metadata
- Authors
- Karikalan, N., Karthik, R., Chen, S.-M., Karuppiah, C., & Elangovan, A.
- Venue
- Scientific Reports
- Published
- 2017-05-30
- Volume
- 7
- Issue
- 1
- Pages
- 2494-2494
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2619272795
- Cited by
- 319
- References
- 35
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.