Haralick texture features from apparent diffusion coefficient (ADC) MRI images depend on imaging and pre-processing parameters
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
In recent years, texture analysis of medical images has become increasingly popular in studies investigating diagnosis, classification and treatment response assessment of cancerous disease. Despite numerous applications in oncology and medical imaging in general, there is no consensus regarding texture analysis workflow, or reporting of parameter settings crucial for replication of results. The aim of this study was to assess how sensitive Haralick texture features of apparent diffusion coefficient (ADC) MR images are to changes in five parameters related to image acquisition and pre-processing: noise, resolution, how the ADC map is constructed, the choice of quantization method, and the number of gray levels in the quantized image. We found that noise, resolution, choice of quantization method and the number of gray levels in the quantized images had a significant influence on most texture features, and that the effect size varied between different features. Different methods for constructing the ADC maps did not have an impact on any texture feature. Based on our results, we recommend using images with similar resolutions and noise levels, using one quantization method, and the same number of gray levels in all quantized images, to make meaningful comparisons of texture feature results between different subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Radiotherapy Plus Concomitant and Adjuvant Temozolomide for Glioblastoma
Stupp, R., Mason, W. P., van den Bent, M. J., Weller, M., Fisher, B., Taphoorn, M. J. B., Belanger, K., Brandes, A. A., Marosi, C., Bogdahn, U., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043330 · Cited by 21,807
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
D'Amico, A. V. (1998) · JAMA · doi:10.1001/jama.280.11.969 · Cited by 4,523
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Table for Estimating the Goodness of Fit of Empirical Distributions
Smirnov, N. (1948) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177730256 · Cited by 1,723
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Texture analysis of SAR sea ice imagery using gray level co-occurrence matrices
Soh, L.-K., & Tsatsoulis, C. (1999) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.752194 · Cited by 1,223
An analysis of co-occurrence texture statistics as a function of grey level quantization
Clausi, D. A. (2002) · Canadian Journal of Remote Sensing · doi:10.5589/m02-004 · Cited by 1,011
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Imaging Intratumor Heterogeneity: Role in Therapy Response, Resistance, and Clinical Outcome
O'Connor, J. P. B., Rose, C. J., Waterton, J. C., Carano, R. A. D., Parker, G. J. M., & Jackson, A. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-0990 · Cited by 677
Image texture analysis: methods and comparisons
Bharati, M. H., Liu, J. J., & MacGregor, J. F. (2004) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.02.005 · Cited by 551
Giornale dell'Istituto italiano degli attuari
attuari, I. I. D. (1930) · Medical Entomology and Zoology · Cited by 449
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Wibmer, A., Hricak, H., Gondo, T., Matsumoto, K., Veeraraghavan, H., Fehr, D., Zheng, J., Goldman, D., Moskowitz, C., Fine, S. W., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3701-8 · Cited by 391
Texture classification using Gabor wavelets based rotation invariant features
Arivazhagan, S., Ganesan, L., & Priyal, S. P. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2006.05.008 · Cited by 274
Gomez, W., Pereira, W. C. A., & Infantosi, A. F. C. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2206398 · Cited by 248
Mayerhoefer, M. E., Szomolanyi, P., Jirak, D., Materka, A., & Trattnig, S. (2009) · Medical Physics · doi:10.1118/1.3081408 · Cited by 225
Ryu, Y. J., Choi, S. H., Park, S. J., Yun, T. J., Kim, J.-H., & Sohn, C.-H. (2014) · PLoS ONE · doi:10.1371/journal.pone.0108335 · Cited by 179
Texture analysis methodologies for magnetic resonance imaging
Materka, A. (2004) · Dialogues in Clinical Neuroscience · doi:10.31887/dcns.2004.6.2/amaterka · Cited by 129
Schieda, N., Thornhill, R. E., Al-Subhi, M., McInnes, M. D. F., Shabana, W. M., van der Pol, C. B., & Flood, T. A. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13279 · Cited by 124
Vignati, A., Mazzetti, S., Giannini, V, Russo, F., Bollito, E., Porpiglia, F., Stasi, M., & Regge, D. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/7/2685 · Cited by 122
Torheim, T., Malinen, E., Kvaal, K., Lyng, H., Indahl, U. G., Andersen, E. K. F., & Futsæther, C. M. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321024 · Cited by 115
Self-citationHeterogeneity in DCE-MRI parametric maps: a biomarker for treatment response?
Alic, L., van Vliet, M., van Dijke, C. F., Eggermont, A. M. M., Veenland, J. F., & Niessen, W. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/006 · Cited by 95
ADC texture—An imaging biomarker for high‐grade glioma?
Brynolfsson, P., Nilsson, D., Henriksson, R., Hauksson, J. B., Karlsson, M. C. F., Garpebring, A., Birgander, R., Trygg, J., Nyholm, T., & Asklund, T. (2014) · Medical Physics · doi:10.1118/1.4894812 · Cited by 85
Self-citationKierans, A. S., Rusinek, H., Lee, A., Shaikh, M. B., Triolo, M. J., Huang, W. C. W., & Chandarana, H. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.14.12570 · Cited by 81
Cai, H., Liu, L., Peng, Y., Wu, Y., & Li, L. (2014) · BMC Cancer · doi:10.1186/1471-2407-14-366 · Cited by 50
(1933) · Medical Entomology and Zoology
Cited by
Deep Learning with Unsupervised Data Labeling for Weed Detection in Line Crops in UAV Images
Bah, M. D., Hafiane, A., & Canals, R. (2018) · Remote Sensing · doi:10.3390/rs10111690 · Cited by 306
Gray-level invariant Haralick texture features
Löfstedt, T., Brynolfsson, P., Asklund, T., Nyholm, T., & Garpebring, A. (2019) · PLOS ONE · doi:10.1371/journal.pone.0212110 · Cited by 261
Self-citationDo, Q. N., Lewis, M. A., Xi, Y., Madhuranthakam, A. J., Happe, S. K., Dashe, J. S., Lenkinski, R. E., Khan, A., & Twickler, D. M. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26883 · Cited by 61
“entr) is a measure of randomness and has been shown to correlate with tissue heterogeneity.(36) Fcm.”
ResultHapsari, R. K., Miswanto, M., Rulaningtyas, R., Suprajitno, H., & Seng, G. H. (2022) · International Journal of Biomedical Imaging · doi:10.1155/2022/5336373 · Cited by 14
Metadata
- Authors
- Brynolfsson, P., Nilsson, D., Torheim, T., Asklund, T., Karlsson, C. T., Trygg, J., Nyholm, T., & Garpebring, A.
- Venue
- Scientific Reports
- Published
- 2017-06-22
- Volume
- 7
- Issue
- 1
- Pages
- 4041-4041
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2626946189
- Cited by
- 167
- References
- 30
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.