A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Dielectric spectroscopy for bioanalysis: From 40 Hz to 26.5 GHz in a microfabricated wave guide
Facer, G. R., Notterman, D. A., & Sohn, L. L. (2001) · Applied Physics Letters · doi:10.1063/1.1347020 · Cited by 166 · cited 1×
“(2) above indicates that a signal of 0.”
BackgroundIntravenous Glucose Tolerance Test-Derived Insulin Sensitivity Changes during the Menstrual Cycle*
VALDES, C. T., & ELKIND-HIRSCH, K. E. (1991) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-72-3-642 · Cited by 141
Mackenzie, R., Maxwell, N., Castle, P., Brickley, G., & Watt, P. (2011) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.1156 · Cited by 133
Self-citationComparability of venous and capillary glucose measurements in blood
Colagiuri, S., Sandbæk, A., Carstensen, B., Christensen, J., Glumer, C., Lauritzen, T., & Borch‐Johnsen, K. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01048.x · Cited by 101
(2003) · BSI Standards · doi:10.3403/02816037 · Cited by 100
Turgul, V., & Kale, İ. (2016) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2016.7520546 · Cited by 72
Koschinsky, T., Jungheim, K., & Heinemann, L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322527030 · Cited by 64
Millimeter-wave non-invasive monitoring of glucose in anesthetized rats
Siegel, P. H., Lee, Y., & Pikov, V. (2014) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2014.6956294 · Cited by 62
Nazarov, M. M., Черкасова, О. П., & Shkurinov, A. P. (2016) · Quantum Electronics · doi:10.1070/qel16107 · Cited by 53
Cano-Garcia, H., Kosmas, P., Sotiriou, I., Papadopoulos-Kelidis, I., Parini, C., Gouzouasis, I. A., Palikaras, G. K., & Kallos, E. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/12/125701 · Cited by 32
Self-citationGouzouasis, I. A., Cano-Garcia, H., Sotiriou, I., Saha, S. C., Palikaras, G. K., Kosmas, P., & Kallos, E. (2016) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2016.7481921 · Cited by 14
Self-citation
Cited by
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72114-3 · Cited by 283
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
“Sensors include microstrip patch antennas [177], spiral microstrip resonator [178,179], open-loop microstrip resonator [180–182], split-ring resonators [1,183,184], patch resonators [172] and dielectric resonator antennas [185].”
Background
Metadata
- Authors
- Saha, S., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I., Koutsoupidou, M., Palikaras, G., Mackenzie, R., Reeve, T., Kosmas, P., & Kallos, E.
- Venue
- Scientific Reports
- Published
- 2017-07-31
- Volume
- 7
- Issue
- 1
- Pages
- 6855-6855
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2739094172
- Cited by
- 171
- References
- 12
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.