A Route to Terahertz Metamaterial Biosensor Integrated with Microfluidics for Liver Cancer Biomarker Testing in Early Stage
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Engineered Terahertz (THz) metamaterials presented an unique characteristics for biosensing application due to their accurately tunable resonance frequency, which is in accord with vibrational frequency of some important biomolecules such as cancer biomarker. However, water absorption in THz regime is an obstacle to extend application in trace biomolecules of cancer antibody or antigen. Here, to overcome water absorption and enhance the THz biosensing sensitivity, two kinds of THz metamaterials biosensor integrated with microfluidics were fabricated and used to detect the Alpha fetoprotein (AFP) and Glutamine transferase isozymes II (GGT-II) of liver cancer biomarker in early stage. There were about 19 GHz resonance shift (5 mu/ml) and 14.2 GHz resonance shift (0.02524 μg/ml) for GGT-II and AFP with a two-gap-metamaterial, respectively, which agreed with simulation results. Those results demonstrated the power and usefulness of metamaterial-assisted THz spectroscopy in trace cancer biomarker molecular detection for biological and chemical sensing. Moreover, for a particular cancer biomarker, the sensitivity could be further improved by optimizing the metamaterial structure and decreasing the permittivity of the substrate. This method might be powerful and potential for special recognition of cancer molecules in the early stage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Wu, C., Khanikaev, A. B., Adato, R., Arju, N., Yanik, A. A., Altug, H., & Shvets, G. (2012) · Nature Materials · doi:10.1038/nmat3161 · Cited by 1,045
Biomedical Applications of Terahertz Spectroscopy and Imaging
Yang, X., Zhao, X., Yang, K., Liu, Y., Liu, Y., Fu, W., & Luo, Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.04.008 · Cited by 968
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
SPR Biosensors: Historical Perspectives and Current Challenges
Singh, P. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.01.118 · Cited by 608
Metamaterial-based microfluidic sensor for dielectric characterization
Withayachumnankul, W., Jaruwongrungsee, K., Tuantranont, A., Fumeaux, C., & Abbott, D. (2013) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.10.027 · Cited by 473
Mechanisms and applications of terahertz metamaterial sensing: a review
Xu, W., Xie, L., & Ying, Y. (2017) · Nanoscale · doi:10.1039/c7nr03824k · Cited by 458
Detection of microorganisms using terahertz metamaterials
Park, S. J., Hong, J. T., Choi, S. J., Kim, H. S., Park, W. K., Han, S. T., Park, J. Y., Lee, S., Kim, D. S., & Ahn, Y. H. (2014) · Scientific Reports · doi:10.1038/srep04988 · Cited by 406
A planar split-ring resonator-based microwave biosensor for label-free detection of biomolecules
Lee, H.-J., Lee, J.-H., Moon, H.-S., Jang, I.-S., Choi, J.-S., Yook, J.-G., & Jung, H.-I. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.01.044 · Cited by 247
Kumar, S., Goel, P., & Singh, J. P. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.10.106 · Cited by 216
Extraordinary sensitivity enhancement by metasurfaces in terahertz detection of antibiotics
Xie, L., Gao, W., Shu, J., Ying, Y., & Kono, J. (2015) · Scientific Reports · doi:10.1038/srep08671 · Cited by 194
Greeneltch, N. G., Blaber, M. G., Henry, A.-I., Schatz, G. C., & Duyne, R. P. V. (2013) · Analytical Chemistry · doi:10.1021/ac303269w · Cited by 165
THz biosensing devices: fundamentals and technology
Nagel, M., Först, M., & Kurz, H. (2006) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/18/18/s07 · Cited by 162
Wu, X., Quan, B., Pan, X., Xu, X., Lu, X., Gu, C., & Wang, L. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.10.095 · Cited by 162
Label-free bioaffinity detection using terahertz technology
Mickan, S. P., Menikh, A., Liu, H., Mannella, C. A., MacColl, R., Abbott, D., Munch, J., & Zhang, X.-C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/317 · Cited by 162
Self-citationCoskun, A. F., Çetin, A. E., Galarreta, B. C., Alvarez, D. A., Altug, H., & Özcan, A. (2014) · Scientific Reports · doi:10.1038/srep06789 · Cited by 153
Васильевна, П. Г., Presnov, D. E., Александрович, К. В., Grigorenko, V., Trifonov, A. S., Andreeva, I. P., Игнатенко, О. В., Egorov, A. M., & Rubtsova, M. Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.054 · Cited by 153
Label-Free Detection of Tobramycin in Serum by Transmission-Localized Surface Plasmon Resonance
Cappi, G., Spiga, F. M., Moncada, Y., Ferretti, A. M., Beyeler, M. J., Bianchessi, M. A., Decosterd, L. A., Buclin, T., & Guiducci, C. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00389 · Cited by 138
Micro Total Analysis Systems: Fundamental Advances and Applications
Patabadige, D. E. W., Jia, S., Sibbitts, J., Sadeghi, J., Sellens, K. A., & Culbertson, C. T. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04310 · Cited by 113
Microfluidic metamaterial sensor: Selective trapping and remote sensing of microparticles
Shih, K., Pitchappa, P., Manjappa, M., Ho, C. P., Singh, R., & Lee, C. (2017) · Journal of Applied Physics · doi:10.1063/1.4973492 · Cited by 100
Real-time Detection of Breast Cancer Cells Using Peptide-functionalized Microcantilever Arrays
Etayash, H., Jiang, K., Azmi, S., Thundat, T. G., & Kaur, K. (2015) · Scientific Reports · doi:10.1038/srep13967 · Cited by 91
Terahertz biosensing based on a polarization-insensitive metamaterial
Wang, S., Xia, L., Mao, H., Jiang, X., Yan, S., Wang, H., Wei, D., Cui, H., & Du, C. (2016) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2016.2522473 · Cited by 74
Surface-Enhanced Raman Spectroscopy Detection of Ricin B Chain in Human Blood
Campos, A. R., Gao, Z., Blaber, M. G., Huang, R., Schatz, G. C., Duyne, R. P. V., & Haynes, C. L. (2016) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b03027 · Cited by 53
Terahertz particle-in-liquid sensing with spoof surface plasmon polariton waveguides
Ma, Z., Hanham, S. M., Huidobro, P. A., Gong, Y., Hong, M., Klein, N., & Maier, S. A. (2017) · APL Photonics · doi:10.1063/1.4998566 · Cited by 48
Microfluidic-SERS devices for one shot limit-of-detection
Kim, D., Campos, A. R., Datt, A., Gao, Z., Rycenga, M., Burrows, N. D., Greeneltch, N. G., Mirkin, C. A., Murphy, C. J., Duyne, R. P. V., et al. (2014) · The Analyst · doi:10.1039/c4an00357h · Cited by 42
Cited by
Tunable and reconfigurable metasurfaces and metadevices
Nemati, A., 1.Institute of Materials Research & Engineering, A. F. S., Wang, Q., Hong, M., Teng, J., & 2.Department of Electrical and Computer Engineering, N. U. O. S. (2018) · Opto-Electronic Advances · doi:10.29026/oea.2018.180009 · Cited by 390
Yan, X., Yang, M., Zhang, Z., Liang, L., Wei, D., Wang, M., Zhang, M., Wang, T., Liu, L., Xie, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.014 · Cited by 375
Terahertz plasmonics: The rise of toroidal metadevices towards immunobiosensings
Ahmadivand, A., Gerislioglu, B., Ahuja, R., & Kumar Mishra, Y. (2020) · Materials Today · doi:10.1016/j.mattod.2019.08.002 · Cited by 373
Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement
Peng, Y., Shi, C., Zhu, Y., Gu, M., & Zhuang, S. (2020) · PhotoniX · doi:10.1186/s43074-020-00011-z · Cited by 300
Metasurfaces for biomedical applications: imaging and sensing from a nanophotonics perspective
Zhang, S., Wong, C. L., Zeng, S., Bi, R., Tai, K., Dholakia, K., & Olivo, M. (2020) · Nanophotonics · doi:10.1515/nanoph-2020-0373 · Cited by 270
Metadata
- Authors
- Geng, Z., Zhang, X., Fan, Z., Lv, X., & Chen, H.
- Venue
- Scientific Reports
- Published
- 2017-11-27
- Volume
- 7
- Issue
- 1
- Pages
- 16378-16378
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2769505393
- Cited by
- 289
- References
- 25
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.