The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Label-free bioaffinity detection using terahertz technology
Abstract
We report the first use of differential terahertz time-domain spectroscopy for bioaffinity sensing. Binding is observed by measuring the transmission of a thin layer of biotin bound to the sensor protein avidin. We demonstrate the THz wave transmission of a sub-micron-thick film and sensitivity to 0.1 microg cm(-2) of biotin. These results point the way for a host of biosensor applications using T-rays, or pulsed far-infrared (FIR) radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Dielectric constant measurement of thin films by differential time-domain spectroscopy
Jiang, Z., Li, M., & Zhang, X.-C. (2000) · Applied Physics Letters · doi:10.1063/1.126587 · Cited by 139
Self-citation
Cited by
Materials for terahertz science and technology
Ferguson, B., & Zhang, X.-C. (2002) · Nature Materials · doi:10.1038/nmat708 · Cited by 3,284
Self-citationTerahertz Technology in Biology and Medicine
Siegel, P. H. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.835916 · Cited by 1,378
Biomedical applications of terahertz technology
Pickwell, E., & Wallace, V. P. (2006) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/39/17/r01 · Cited by 925
Metamaterials Application in Sensing
Chen, T., Li, S., & Sun, H. (2012) · Sensors · doi:10.3390/s120302742 · Cited by 557
Mechanisms and applications of terahertz metamaterial sensing: a review
Xu, W., Xie, L., & Ying, Y. (2017) · Nanoscale · doi:10.1039/c7nr03824k · Cited by 458
Metadata
- Authors
- Mickan, S. P., Menikh, A., Liu, H., Mannella, C. A., MacColl, R., Abbott, D., Munch, J., & Zhang, X.-C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-10-16
- Volume
- 47
- Issue
- 21
- Pages
- 3789-3795
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W2098553180
- Cited by
- 162
- References
- 2
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-free bioaffinity detection using terahertz technology. https://app.cochat.ai/papers/10.1088/0031-9155/47/21/317
- The paper
- Mickan, S. P., Menikh, A., Liu, H., Mannella, C. A., MacColl, R., Abbott, D., Munch, J., & Zhang, X.-C. (2002). Label-free bioaffinity detection using terahertz technology. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/47/21/317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.