Wearable Sweat Rate Sensors for Human Thermal Comfort Monitoring
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We propose watch-type sweat rate sensors capable of automatic natural ventilation by integrating miniaturized thermo-pneumatic actuators, and experimentally verify their performances and applicability. Previous sensors using natural ventilation require manual ventilation process or high-power bulky thermo-pneumatic actuators to lift sweat rate detection chambers above skin for continuous measurement. The proposed watch-type sweat rate sensors reduce operation power by minimizing expansion fluid volume to 0.4 ml through heat circuit modeling. The proposed sensors reduce operation power to 12.8% and weight to 47.6% compared to previous portable sensors, operating for 4 hours at 6 V batteries. Human experiment for thermal comfort monitoring is performed by using the proposed sensors having sensitivity of 0.039 (pF/s)/(g/m 2 h) and linearity of 97.9% in human sweat rate range. Average sweat rate difference for each thermal status measured in three subjects shows (32.06 ± 27.19) g/m 2 h in thermal statuses including ‘comfortable’, ‘slightly warm’, ‘warm’, and ‘hot’. The proposed sensors thereby can discriminate and compare four stages of thermal status. Sweat rate measurement error of the proposed sensors is less than 10% under air velocity of 1.5 m/s corresponding to human walking speed. The proposed sensors are applicable for wearable and portable use, having potentials for daily thermal comfort monitoring applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
Physiology of Thermoregulation
Kurz, A. (2008) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2008.06.004 · Cited by 222 · cited 3×
“(2-5), we find the equation for the temperature of the expansion fluid, T1 depending on the heat power, Q.”
Skin and core temperature response to partial- and whole-body heating and cooling
Huizenga, C., Zhang, H., Arens, E., & Wang, D. (2004) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2004.08.024 · Cited by 213
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151
Self-citationA thermal peripheral blood flowmeter with contact force compensation
Sim, J. K., Youn, S., & Cho, Y.-H. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/12/125014 · Cited by 10
Self-citation
Cited by
Kim, D. W., Baik, S., Min, H., Chun, S., Lee, H. J., Kim, K. H., Lee, J. Y., & Pang, C. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807614 · Cited by 215
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Energy Autonomous Sweat‐Based Wearable Systems
Manjakkal, L., Yin, L., Nathan, A., Wang, J., & Dahiya, R. (2021) · Advanced Materials · doi:10.1002/adma.202100899 · Cited by 170
Zhong, B., Jiang, K., Wang, L., & Shen, G. (2022) · Advanced Science · doi:10.1002/advs.202103257 · Cited by 164
Engineering the Comfort‐of‐Wear for Next Generation Wearables
Shimura, T., Sato, S., Zalar, P., & Matsuhisa, N. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202200512 · Cited by 86
Metadata
- Authors
- Sim, J. K., Yoon, S., & Cho, Y.-H.
- Venue
- Scientific Reports
- Published
- 2018-01-19
- Volume
- 8
- Issue
- 1
- Pages
- 1181-1181
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2782781832
- Cited by
- 96
- References
- 5
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.