Magnetocardiography on an isolated animal heart with a room-temperature optically pumped magnetometer
Open accessThe DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Abstract
Optically pumped magnetometers are becoming a promising alternative to cryogenically-cooled superconducting magnetometers for detecting and imaging biomagnetic fields. Magnetic field detection is a completely non-invasive method, which allows one to study the function of excitable human organs with a sensor placed outside the human body. For instance, magnetometers can be used to detect brain activity or to study the activity of the heart. We have developed a highly sensitive miniature optically pumped magnetometer based on cesium atomic vapor kept in a paraffin-coated glass container. The magnetometer is optimized for detection of biological signals and has high temporal and spatial resolution. It is operated at room- or human body temperature and can be placed in contact with or at a mm-distance from a biological object. With this magnetometer, we detected the heartbeat of an isolated guinea-pig heart, which is an animal widely used in biomedical studies. In our recordings of the magnetocardiogram, we can detect the P-wave, QRS-complex and T-wave associated with the cardiac cycle in real time. We also demonstrate that our device is capable of measuring the cardiac electrographic intervals, such as the RR- and QT-interval, and detecting drug-induced prolongation of the QT-interval, which is important for medical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





![Figure 6 Effects of IKr inhibition on heart rate and QT-interval. (a) Example magnetometer signals recorded before and after administration of 0.06 μM E-4031. Traces are the averages of approximately 10 heartbeats. (b) Heart rate in beats per minute: bpm = 60/RR-interval [s]. Points are mean values averaged over 5 animals. Error bars represent the standard error of the mean. (c) QT-interval corrected for heart rate (Bazett correction35). In (b and c), heart rate and QT-intervals are measured before (t = 0 data points) and 5, 10, 15, and 20 minutes after administration of the drug.](https://figures.cochat.ai/paper-figures/3abc85d8d19d46caa7a28246e4418af6/magnetocardiography-on-an-isolated-animal-heart-with-a-room-temperature-figure-6.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Moreover, MCG has proven useful for the non-invasive study of experimental intact animals (84) and contactless high-resolution investigation of experimental electrophysiology of isolated heart (85) and cardiac tissue models (86).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [85]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Prevalence of the Congenital Long-QT Syndrome
Schwartz, P. J., Stramba-Badiale, M., Crotti, L., Pedrazzini, M., Besana, A., Bosi, G., Gabbarini, F., Goulene, K., Insolia, R., Mannarino, S., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.863209 · Cited by 1,072
(2009) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181aef106 · Cited by 895
Retrograde heart perfusion: The Langendorff technique of isolated heart perfusion
Bell, R. M., Mocanu, M. M., & Yellon, D. M. (2011) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2011.02.018 · Cited by 505
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Quantum Noise Limited and Entanglement-Assisted Magnetometry
Wasilewski, W., Jensen, K., Krauter, H., Renema, J. J., Balabas, M. V., & Polzik, E. S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.133601 · Cited by 434
Self-citationSpin-exchange-relaxation-free magnetometry with Cs vapor
Ledbetter, M. P., Savukov, I. M., Acosta, V. M., Budker, D., & Romalis, M. V. (2008) · Physical Review A · doi:10.1103/physreva.77.033408 · Cited by 399
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Cited by
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“This can lead to a clinical decision for medical intervention, even before birth [4].”
BackgroundCriticality-Enhanced Quantum Sensing via Continuous Measurement
Ilias, T., Yang, D., Huelga, S. F., & Plenio, M. B. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.010354 · Cited by 210
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
“Most MEMS vapor cells are filled with buffer gas, although antirelaxation-coated cells may offer advantages for biological applications where elevated-temperature operation is problematic [24, 155].”
BackgroundMillimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Improving cold-atom sensors with quantum entanglement: Prospects and challenges
Szigeti, S. S., Hosten, O., & Haine, S. A. (2021) · Applied Physics Letters · doi:10.1063/5.0050235 · Cited by 90
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
“The interest for MCG in animals’ experimental models is progressively increasing, and its application for the electrophysiological study of transgenic models of cardiomyopathy, experimental myocardial injury, and regulatory pharmacological preclinical evaluation has been confirmed by other authors, working in MSR with…”
BackgroundMethodWebb, J. L., Troise, L., Hansen, N. W., Olsson, C., Wojciechowski, A. M., Achard, J., Brinza, O., Staacke, R., Kieschnick, M., Meijer, J., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-81828-x · Cited by 84
Fiber-Coupled Diamond Magnetometry with an Unshielded Sensitivity of 30 pT / Hz
Graham, S. M., Rahman, A., Munn, L., Patel, R. L., Newman, A. J., Stephen, C. J., Colston, G., Nikitin, A. P., Edmonds, A. M., Twitchen, D. J., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044042 · Cited by 71
Fourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
Action potentials induce biomagnetic fields in carnivorous Venus flytrap plants
Fabricant, A. M., Iwata, G. Z., Scherzer, S. H., Bougas, L., Rolfs, K., Jodko-Władzińska, A., Voigt, J., Hedrich, R., & Budker, D. (2021) · Scientific Reports · doi:10.1038/s41598-021-81114-w · Cited by 65
Measurement of Triaxial Magnetocardiography Using High Sensitivity Tunnel Magnetoresistance Sensor
Wang, M., Wang, Y., Peng, L., & Ye, C. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2927086 · Cited by 55
“In present, due to the fact that the T-wave is not separated from the noise, such device is not capable of measuring the cardiac electrographic intervals, such as the RR- and QT-interval [13], [26], and detecting drug-induced prolongation of the QT-interval [27].”
BackgroundQuantum magnetic gradiometer with entangled twin light beams
Wu, S., Bao, G., Guo, J., Chen, J., Du, W., Shi, M., Yang, P., Chen, L. Q., & Zhang, W. (2023) · Science Advances · doi:10.1126/sciadv.adg1760 · Cited by 60
“The sensitive measurement of magnetic field at low frequencies has been a great challenge for practical applications ( 15 – 17 ).”
All-optical atomic magnetometry using an elliptically polarized amplitude-modulated light wave
Makarov, A., Kozlova, K., Brazhnikov, D. V., Vishnyakov, V. I., & Goncharov, A. (2024) · Optics Communications · doi:10.1016/j.optcom.2024.131369 · Cited by 49
Investigation of Converse Magnetoelectric Thin-Film Sensors for Magnetocardiography
Elzenheimer, E., Hayes, P., Thormählen, L., Engelhardt, E., Zaman, A., Quandt, E., Frey, N., Höft, M., & Schmidt, G. U. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3237910 · Cited by 50
Wide-bandwidth atomic magnetometry via instantaneous-phase retrieval
Wilson, N., Perrella, C., Anderson, R., Luiten, A. N., & Light, P. S. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.013213 · Cited by 42
“[7] K.”
BackgroundA cold atom radio-frequency magnetometer
Cohen, Y., Jadeja, K., Sula, S., Venturelli, M., Deans, C., Marmugi, L., & Renzoni, F. (2019) · Applied Physics Letters · doi:10.1063/1.5084004 · Cited by 44
Noisy atomic magnetometry in real time
Amorós-Binefa, J., & Kołodyński, J. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac3b71 · Cited by 48
Rushton, L. M., Pyragius, T., Meraki, A., Elson, L., & Jensen, K. (2022) · Review of Scientific Instruments · doi:10.1063/5.0102402 · Cited by 37
Self-citationDetection of low-conductivity objects using eddy current measurements with an optical magnetometer
Jensen, K., Zugenmaier, M., Arnbak, J., Stærkind, H., Balabas, M. V., & Polzik, E. S. (2019) · Physical Review Research · doi:10.1103/physrevresearch.1.033087 · Cited by 40
“The key component of our magnetometer is a paraffincoated cesium vapor cell with a (5 mm) 3 inner volume [25].”
BackgroundSelf-citationRecording the heart beat of cattle using a gradiometer system of optically pumped magnetometers
Sutter, J. U., Lewis, O., Robinson, C., McMahon, A., Boyce, R., Bragg, R., Macrae, A., Orton, J., Shah, V., Ingleby, S. J., et al. (2020) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2020.105651 · Cited by 35
Sub-Sm–1 electromagnetic induction imaging with an unshielded atomic magnetometer
Deans, C., Marmugi, L., & Renzoni, F. (2020) · Applied Physics Letters · doi:10.1063/5.0002146 · Cited by 37
Ultrastable Optical Magnetometry
Wilson, N., Light, P. S., Luiten, A. N., & Perrella, C. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.044034 · Cited by 33
Zhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
Electromagnetic induction imaging with atomic magnetometers: Unlocking the low-conductivity regime
Marmugi, L., Deans, C., & Renzoni, F. (2019) · Applied Physics Letters · doi:10.1063/1.5116811 · Cited by 33
Hybrid sensor integration in wearable devices for improved cardiovascular health monitoring
Khan, B., Khan, W., Masrur, M. A., Khalid, R. T., Awais, M., Khan, B., Khoo, B. L., & Abdullah, S. (2025) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2025.100889 · Cited by 36
Han, X., Xue, X., Yang, Y., Liang, X., Gao, Y., Xiang, M., Sun, J., & Ning, X. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ace497 · Cited by 25
An optically pumped magnetic gradiometer for the detection of human biomagnetism
Cook, H., Bezsudnova, Y., Koponen, L. M., Jensen, O. B., Barontini, G., & Kowalczyk, A. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad3d81 · Cited by 25
Wang, L., Shi, M., Le, Y., Zhang, X., Yang, J., Yuan, S., & Ma, Y. (2024) · Measurement · doi:10.1016/j.measurement.2024.114276 · Cited by 22
Suppression of modulation-magnetic-fields crosstalk for single-beam optically-pumped magnetometers
Suo, Y., Song, X., Jiang, L., Jia, L., Long, T., & Wu, Z. (2023) · Measurement · doi:10.1016/j.measurement.2023.113059 · Cited by 20
Liao, Z., Jin, S., Kuwahata, A., Sekino, M., & Tabata, H. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac1de5 · Cited by 20
Chip-Scale Ultra-Low Field Atomic Magnetometer Based on Coherent Population Trapping
Hong, H.-G., Park, S. E., Lee, S.-B., Heo, M.-S., Park, J., Kim, T. H., Kim, H. Y., & Kwon, T. Y. (2021) · Sensors · doi:10.3390/s21041517 · Cited by 19
A Single-Axis Atomic Magnetometer-Based Mouse Magnetocardiography Measurement System
Sun, Y., Xixi, W., Zhou, Y., Qin, J., Bai, D., Wang, Y., & Zhou, Z. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3265089 · Cited by 21
“heart [26], and remote automated monitoring of the heart rate”
BackgroundZero-field optical magnetometer based on spin alignment
Meraki, A., Elson, L., Ho, N. J., Akbar, A., Koźbiał, M., Kołodyński, J., & Jensen, K. (2023) · Physical Review A · doi:10.1103/physreva.108.062610 · Cited by 20
Self-citationPortable single-beam cesium zero-field magnetometer for magnetocardiography
Dawson, R., O’Dwyer, C., Mrozowski, M. S., Irwin, E., McGilligan, J. P., Burt, D. P., Hunter, D., Ingleby, S. J., Rea, M., Holmes, N., et al. (2023) · Journal of Optical Microsystems · doi:10.1117/1.jom.3.4.044501 · Cited by 21
“22 Careful selection of the sensing atom to inform skin-safe sensor operation temperature is similarly demonstrated by room-temperature helium zero-field sensors.”
BackgroundXing, B., Lu, J., Sun, C., Yu, T., Wu, Y., Gao, Y., & Han, B. (2022) · Optics Express · doi:10.1364/oe.449951 · Cited by 18
Spin noise spectroscopy of an alignment-based atomic magnetometer
Koźbiał, M., Elson, L., Rushton, L. M., Akbar, A., Meraki, A., Jensen, K., & Kołodyński, J. (2024) · Physical Review A · doi:10.1103/physreva.110.013125 · Cited by 17
“Commercially available OPMs include scalar OPMs for use in e.g. geophysical surveys [4, 5] and zero-field OPMs [5–8] which are promising for applications within areas such as cardiology [9–11] and neuroscience [12–14].”
BackgroundSelf-citationA Room‐Temperature Operational Alignment Magnetometer Utilizing Free‐Spin Precession
Jin, G., Shi, T., Zhao, Y., Zhang, H., & Zou, S. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202300377 · Cited by 17
Noisy Atomic Magnetometry with Kalman Filtering and Measurement-Based Feedback
Amorós-Binefa, J., & Kołodyński, J. (2025) · PRX Quantum · doi:10.1103/k7nk-lrwd · Cited by 24
“As a result, they promise breakthroughs, e.g., when used to sense magnetic fields in medical applications [4–7], as well as in the search for new exotic physics [8, 9].”
Enger, L. G., Flament, S., Bhatti, I. N., Rousseau, O., Guillet, B., Sing, M. L. C., Pierron, V., Lebargy, S., Chaluvadi, S. K., Domengès, B., et al. (2023) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.2c01096 · Cited by 16
Laser Heating Method for an Alkali Metal Atomic Cell with Heat Transfer Enhancement
Li, Y., Zhou, G., Tian, S., Liu, X., Dong, X., & Gao, X. (2023) · Photonics · doi:10.3390/photonics10060637 · Cited by 15
Acoustic frequency atomic spin oscillator in the quantum regime
Jia, J. F., Novikov, V. A., Brasil, T. B., Zeuthen, E., Müller, J. H., & Polzik, E. S. (2023) · Nature Communications · doi:10.1038/s41467-023-42059-y · Cited by 13
“fields in the acoustic frequency range is a powerful tool in biomedical applications [38].”
BackgroundSelf-citationSpin dynamic response to a time dependent field
Bevilacqua, G., Biancalana, V., Dancheva, Y., Fregosi, A., & Vigilante, A. (2021) · Applied Physics B · doi:10.1007/s00340-021-07673-y · Cited by 11
A feed-forward measurement scheme for periodic noise suppression in atomic magnetometry
O’Dwyer, C., Ingleby, S. J., Chalmers, I. C., Griffin, P. F., & Riis, E. (2020) · Review of Scientific Instruments · doi:10.1063/5.0002964 · Cited by 11
Silva, M., Franco, F., Leitão, D. C., Cardoso, S., & Freitas, P. P. (2021) · Scientific Reports · doi:10.1038/s41598-020-79856-0 · Cited by 10
Akbar, A., Koźbiał, M., Elson, L., Meraki, A., Kołodyński, J., & Jensen, K. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.054033 · Cited by 10
Self-citationEnhancement of the Signal-to-Noise Ratio of an Atomic Magnetometer by 10 dB
Bao, G., Wu, S., Liu, S., Huang, W., Li, Z., Chen, L. Q., Yuan, C.-H., & Zhang, W. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.054075 · Cited by 9
Quantum sensors probe uncharted territories, from Earth’s crust to the human brain
Battersby, S. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1912326116 · Cited by 8
The effect of sensor-to-source distance on magnetic neuromuscular signals
Yang, H., Klotz, T., Gizzi, L., Lu, H., Monittola, G., Schneider, U., Siegel, M., & Marquetand, J. C. (2025) · Scientific Reports · doi:10.1038/s41598-025-06545-1 · Cited by 7
Zhu, M., Wang, L., Guo, J., Zhao, X., Sun, X., Ye, C., & Zhou, X. H. (2021) · Optics Express · doi:10.1364/oe.435841 · Cited by 7
Measurement of T wave in magnetocardiography using tunnel magnetoresistance sensor
Lu, Z., Ji, S., & Yang, J. (2022) · Chinese Physics B · doi:10.1088/1674-1056/aca5fe · Cited by 7
SMF-MMF-SCF-Based Humanoid-Shaped Fiber-Optic Sensor for Wide Range of Magnetic Field Detection
Yin, Q., Singh, R., Wang, Y., Zhang, B., & Kumar, S. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3409508 · Cited by 7
“…sensors, with their lightweight, miniaturized design, remote manipulation capabilities, and real-time monitoring functions, are particularly useful in the detection of electromagnetic systems [1], [2], geologic exploration [3], [4], biomedical imaging [5], [6], [7], [8], [9], and other fields.”
BackgroundOptimized design of small sized low noise magnetic shielding cylinder
Sun, J., Zhao, X., Zhang, X., Zhang, D., Zhao, Z., Yang, J., & Lu, Y. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad1f24 · Cited by 7
Albertová, P., Gram, M., Blaimer, M., Bauer, W. R., Jakob, P. M., & Nordbeck, P. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30190 · Cited by 6
SERF-like magnetometry in room-temperature environment
Bao, G., Chen, J., Wang, R., Chen, L. Q., & Zhang, W. (2023) · Optics Express · doi:10.1364/oe.500875 · Cited by 6
Ranjbaran, M., sedeyan, R., Zamani, A., Tehranchi, M. M., Khalkhali, S. M. H., & Hamidi, S. M. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.172335 · Cited by 5
Optimization of error signal lineshape for modulation-free robust laser frequency stabilization
Yadav, P., Ghosh, A., Singh, N., Yadav, V. K., Singh, D., Singh, K., & Santra, B. (2025) · Physica Scripta · doi:10.1088/1402-4896/adbf70 · Cited by 5
Impact of electric spatially discordant alternans on cardiac magnetic field
Nicoletti, M., Crispino, A., Loppini, A., Gizzi, A., Chiodo, L., Cherubini, C., & Filippi, S. (2025) · Physical review. E · doi:10.1103/ys62-2n7g · Cited by 4
Precision Magnetic Field Sensing with Dual Multi-Wave Atom Interferometer
Yan, W., Ren, X., Zhou, M.-K., & Hu, Z.-K. (2022) · Sensors · doi:10.3390/s23010173 · Cited by 4
Advances in laser heating of alkali vapor cells in magnetometers: a review
Wang, K., Zhou, B., Tang, J., Zhang, S., & Wang, Y. (2020) · Applied Optics and Photonics China (AOPC) · doi:10.1117/12.2574588 · Cited by 5
Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands
Campbell, K., Wang, Y.-J., Savukov, I., Schwindt, P. D. D., Jau, Y., & Shah, V. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.163602 · Cited by 4
Sahoo, S. S., Mishra, S. R., Rajalakshmi, G., & Mohapatra, A. K. (2022) · Physical Review A · doi:10.1103/physreva.105.063509 · Cited by 4
Small Animal Biomagnetism Applications
Jensen, K., Bentzen, B. H., & Polzik, E. S. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_3 · Cited by 5
“our work on detecting the heartbeat in a guinea pig heart [23] and our work towards imaging the electrical conductivity of the heart [24] are discussed in Sec.”
BackgroundMethodInfluentialSelf-citationMagnetic Field and Temperature Dual-Parameter Sensor Based on PDMS and Fe 3 O 4 Magnetized Film
Jiang, C., Chen, C., & Qin, Z. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3592223 · Cited by 2
“These technological merits have accelerated the deployment of environmental magnetic field monitoring [1], [2], mineral exploration [3], [4], and biomedical diagnostic instrumentation [5], [6], [7], [8].”
Accurate measurement of the residual field in a magnetic shield using optically pumped 133Cs atoms
Ding, Z., & Yuan, J. (2021) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.168120 · Cited by 2
Action potentials induce biomagnetic fields in Venus flytrap plantsPreprint
Fabricant, A. M., Iwata, G. Z., Scherzer, S. H., Bougas, L., Rolfs, K., Jodko-Władzińska, A., Voigt, J., Hedrich, R., & Budker, D. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.08.12.247924 · Cited by 2
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd12090343 · Cited by 1
Thermalization of rubidium atoms scattered from a low-temperature paraffin film
Tanaka, Y., Asakawa, K., Usui, H., & Hatakeyama, A. (2026) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ae43a4 · Cited by 1
Chip-scale packaged in-line polarization-resolved detector for optically pumped magnetometers
Cho, H. J., Na, Y., Park, S. S., Lee, M.-H., Kim, H., Ju, J., Kim, D., Kang, I., You, J.-B., Park, G., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01226-z · Cited by 1
A novel method for measuring the effective permeability of a μ-metal magnetic shield
Ding, Z., & Li, J. (2024) · Computational Materials Science · doi:10.1016/j.commatsci.2024.113416 · Cited by 1
Masia‐Roig, H. (2023) · Gutenberg Open Science · doi:10.25358/openscience-9600 · Cited by 2
Safi, B., Safi, F. R. M., & ATIF, A. (2023) · Nangarhar University international journal of biosciences. · doi:10.70436/nuijb.v2i03.65 · Cited by 1
Atomic Gradiometers for Accuracy Enhancement of Heart Magnetic Fields Measurement
Ranjbaran, M., sedeyan, R., Zamani, A., Tehranchi, M. M., Khalkhali, S. M. H., & Hamidi, S. M. (2023) · Dunyā. · doi:10.61186/ijop.17.2.155
Phase projection errors in rf-driven optically pumped magnetometers
Grujić, Z. D., Ćurčić, M. M., Kocić, A., Weis, A., & Scholtes, T. (2026) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-026-00517-8
Quantum-Enhanced Metrology and Sensing
Simon, D. S. (2025) · Undergraduate texts in physics · doi:10.1007/978-3-031-81315-3_19
Recent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Optical transformation based magnetic field guide for optically pumped magnetometers
Wang, S. (2023) · UPCommons institutional repository (Universitat Politècnica de Catalunya)
Optical Magnetometry with an Ensemble of Ultracold Atoms
Shibata, K., & Hirano, T. (2024) · The Review of Laser Engineering · doi:10.2184/lsj.52.3_137
Gal, G. L. (2022) · theses.fr (ABES) · doi:10.70675/087f6445zef80z4bbfz837ez1374c2977052
Optimal and efficient inference tools for field tracking with precessing spins
Anonymous, Bania, P., Méndez-Avalos, D., Sierant, A., Mitchell, M. W., & Kołodyński, J. (2026) · Physical Review Applied · doi:10.1103/jfhj-kr1j
“These features enable emerging technologies such as magnetic navigation in GPS-denied environments [10, 11], ultra-low-field NMR [12] and MRI [13], and materials characterisation [14], as well as medical applications for sensing brain (MEG [15]) or heart (MCG [16, 17]) signals.”
Exploiting random telegraph noise to reveal spin-environment coupling in atomic magnetometers
Geng, X., Xie, A.-D., Jin, K., Liu, S.-J., Guo-Qing, Y., Huang, G., Liu, H., & Li, G. (2026) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ae9c0f
Ding, N., Li, H., & Xiang, M. (2026) · International Conference on Bioinformatics and Intelligent Computing (BIC) · doi:10.1145/3809986.3810108
Ultrahigh‐Quality 780 nm Bragg Grating Fabry‐Pérot Cavity on an Etchless Lithium Niobate Platform
Fan, X., Bai, S., Li, H., Li, K., Zhai, K., Dong, W., Zhou, H., Zhang, X., Zhu, N., Wen, H., et al. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71821
Fiber-coupled Diamond Magnetometry with an Unshielded 30 pT/$\sqrt{\textrm{Hz}}$ Sensitivity
Graham, S. M., Rahman, A. T. M. A., Munn, L., Patel, R. L., Newman, A. J., Stephen, C. J., Colston, G., Nikitin, A., Edmonds, A. M., Twitchen, D. J., et al. (2022) · arXiv · doi:10.48550/arxiv.2211.09170
Metadata
- Authors
- Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S.
- Affiliations
- University of Copenhagen (DK)
- Corresponding author
- Jensen, Kasper
- ORCID
- Venue
- Scientific Reports
- Published
- 2018-11-01
- Volume
- 8
- Issue
- 1
- Pages
- 16218-16218
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6212485
- OpenAlex
- W2810392889
- Semantic Scholar
- d805c242291e0bda4c9adbc95732377b7d7e2dc3
- Cited by
- 79
- References
- 35
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 12 · 2023: 17 · 2022: 9 · 2021: 14 · 2020: 8 · 2019: 7
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Innovationsfonden
- Army Research Office (W911NF, W911NF-11-0235, W911NF-11)
- Army Research Laboratory (W911NF)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- magnetocardiography, optically pumped magnetometers, room-temperature magnetometry, isolated guinea pig heart, cardiac magnetic field, P wave, QRS complex, T wave, QT interval, RR interval, drug-induced QT prolongation, cardiac electrophysiology
- MeSH terms
- Algorithms, Animals, Electrocardiography, Guinea Pigs, Heart, Humans, Models, Biological, Temperature, Electrophysiologic Techniques, Cardiac, Magnetocardiography, Magnetometry, Optical Imaging, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.