The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Wide-field choroidal thickness profile in healthy eyes
Open accessAbstract
The introduction of wide field optical coherence tomography (WF-OCT) has provided newer insights in the imaging of peripheral choroid. We evaluated choroidal thickness (CT) and large choroidal vessel thickness (LCVT) of 20 eyes in horizontal and vertical meridians using WF-OCT. A high-definition line scan through the fovea in both horizontal and vertical meridian was captured in primary and extremes of gaze to obtain scans up to mid-equator. CT and LCVT measurements were done across predefined points in macular area and all quadrants. LCVT was calculated after identifying a large choroidal vessel near choroidoscleral interface. The main outcome measures were differences in CT and LCVT in macular and four quadrants. Mean CT (331.23 ± 76.34 µ) and LCVT (201.46 ± 54.31 µ) in vertical macular segment were significantly more than CT (245.79 ± 55.38 µ; p = 0.0002) and LCVT (150.48 ± 52.58 µ; p = 0.004) in horizontal macular segment. CT at peripheral points in all quadrants was significantly reduced as compared to subfoveal CT (all p values < 0.05) with maximum reduction in inferior quadrant (64.5%). Using linear regression, only quadrant had a significant effect on CT and LCVT (both p < 0.001). CT and LCVT are highest at the macular area with reduction towards the periphery. The contribution of LCVT to CT is less at the fovea compared to other peripheral points.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nickla, D. L., & Wallman, J. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.12.002 · Cited by 1,945
Central serous chorioretinopathy: Recent findings and new physiopathology hypothesis
Daruich, A., Matet, A., Dirani, A., Bousquet, E., Zhao, M., Farman, N., Jaisser, F., & Behar-Cohen, F. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.05.003 · Cited by 989
Choroidal Thickness in Normal Eyes Measured Using Cirrus HD Optical Coherence Tomography
Manjunath, V., Taha, M., Fujimoto, J. G., & Duker, J. S. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.04.018 · Cited by 490
Hirata, M., Tsujikawa, A., Matsumoto, A., Hangai, M., Ooto, S., Yamashiro, K., Akiba, M., & Yoshimura, N. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7729 · Cited by 365
In vivo choroidal circulation and its watershed zones
Hayreh, S. S. (1990) · Eye · doi:10.1038/eye.1990.39 · Cited by 319
Manjunath, V., Goren, J., Fujimoto, J. G., & Duker, J. S. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.03.008 · Cited by 277
Barteselli, G., Chhablani, J., El-Emam, S., Wang, H., Chuang, J., Kozak, I., Cheng, L., Bartsch, D.-U., & Freeman, W. R. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.06.065 · Cited by 220
Self-citationOuyang, Y., Heussen, F. M., Mokwa, N., Walsh, A. C., Durbin, M. K., Keane, P. A., Sanchez, P. J., Ruiz-Garcia, H., & Sadda, S. R. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8046 · Cited by 166
Sánchez-Cano, A. I., Orduna, E., Segura, F. J., FUENTE, C. L. D. L., Cuenca, N., Abecia, E., & Pinilla, I. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.05.035 · Cited by 114
Shin, J. W., Shin, Y. U., & Lee, B. R. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.10.029 · Cited by 105
Cited by
Autophagy and the hallmarks of aging
Kaushik, S., Tasset, I., Arias, E., Pampliega, O., Wong, E., Martinez-Vicente, M., & Cuervo, A. M. (2021) · Ageing Research Reviews · doi:10.1016/j.arr.2021.101468 · Cited by 285
Al Zoubi, W., Kamil, M. P., Fatimah, S., Nashrah, N., & Ko, Y. G. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100663 · Cited by 265
C5a anaphylatoxin and its role in critical illness-induced organ dysfunction
Wood, A. J. T., Vassallo, A., Summers, C., Chilvers, E. R., & Conway‐Morris, A. (2018) · European Journal of Clinical Investigation · doi:10.1111/eci.13028 · Cited by 45
Modrackova, N., Stovicek, A., Burtscher, J., Bolechova, P., Killer, J., Domig, K. J., & Neuzil-Bunesova, V. (2021) · Scientific Reports · doi:10.1038/s41598-021-94824-y · Cited by 32
Metadata
- Authors
- Rasheed, M. A., Singh, S. R., Invernizzi, A., Cagini, C., Goud, A., Sahoo, N. K., Cozzi, M., Lupidi, M., & Chhablani, J.
- Venue
- Scientific Reports
- Published
- 2018-11-21
- Volume
- 8
- Issue
- 1
- Pages
- 17166-17166
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2901325458
- Cited by
- 287
- References
- 13
- FWCI
- 60.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wide-field choroidal thickness profile in healthy eyes. https://app.cochat.ai/papers/10.1038/s41598-018-35640-9
- The paper
- Rasheed, M. A., Singh, S. R., Invernizzi, A., Cagini, C., Goud, A., Sahoo, N. K., Cozzi, M., Lupidi, M., & Chhablani, J. (2018). Wide-field choroidal thickness profile in healthy eyes. Scientific Reports. https://doi.org/10.1038/s41598-018-35640-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.