The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Wireless wide-range pressure sensor based on graphene/PDMS sponge for tactile monitoring
Open accessAbstract
We propose a flexible wireless pressure sensor, which uses a graphene/polydimethylsiloxane (GR/PDMS) sponge as the dielectric layer. The sponge is sandwiched between two surfaces of a folded flexible printed circuit with patterned Cu as the antenna and electrode. By adjusting graphene and NH 4 HCO 3 concentrations, a composite with 20% concentration of NH 4 HCO 3 and 2% concentration of graphene as the dielectric layer is obtained, which exhibits high sensitivity (2.2 MHz/kPa), wide operating range (0–500 kPa), rapid response time (~7 ms), low detection limit (5 Pa), and good stability, recoverability, and repeatability. In addition, the sensor is sensitive to finger bending and facial muscle movements for smile and frown, that are transmitted using wireless electromagnetic coupling; therefore, it has potential for a wide range of applications such as intelligent robots, bionic-electronic skin and wearable electronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
An, B. W., Heo, S., Ji, S., Bien, F., & Park, J.-U. (2018) · Nature Communications · doi:10.1038/s41467-018-04906-1 · Cited by 426
Shin, S.-H., Ji, S., Choi, S., Pyo, K.-H., Wan An, B., Park, J., Kim, J., Kim, J.-Y., Lee, K.-S., Kwon, S.-Y., et al. (2017) · Nature Communications · doi:10.1038/ncomms14950 · Cited by 203
Kim, M., Park, J., Ji, S., Shin, S.-H., Kim, S.-Y., Kim, Y.-C., Kim, J.-Y., & Park, J.-U. (2016) · Nanoscale · doi:10.1039/c6nr02041k · Cited by 73
Cited by
Chen, X., Liu, H., Zheng, Y., Zhai, Y., Liu, X., Liu, C., Mi, L., Guo, Z., & Shen, C. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14688 · Cited by 357
Shi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Recent advances in noninvasive flexible and wearable wireless biosensors
Salim, A., & Lim, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111422 · Cited by 153
Metadata
- Authors
- Kou, H., Zhang, L., Tan, Q., Liu, G., Dong, H., Zhang, W., & Xiong, J.
- Venue
- Scientific Reports
- Published
- 2019-03-08
- Volume
- 9
- Issue
- 1
- Pages
- 3916-3916
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2920038160
- Cited by
- 173
- References
- 6
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless wide-range pressure sensor based on graphene/PDMS sponge for tactile monitoring. https://app.cochat.ai/papers/10.1038/s41598-019-40828-8
- The paper
- Kou, H., Zhang, L., Tan, Q., Liu, G., Dong, H., Zhang, W., & Xiong, J. (2019). Wireless wide-range pressure sensor based on graphene/PDMS sponge for tactile monitoring. Scientific Reports. https://doi.org/10.1038/s41598-019-40828-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.