Chemically Functionalised Graphene FET Biosensor for the Label-free Sensing of Exosomes
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
A graphene field-effect transistor (gFET) was non-covalently functionalised with 1-pyrenebutyric acid N-hydroxysuccinimide ester and conjugated with anti-CD63 antibodies for the label-free detection of exosomes. Using a microfluidic channel, part of a graphene film was exposed to solution. The change in electrical properties of the exposed graphene created an additional minimum alongside the original Dirac point in the drain-source current (Ids) - back-gate voltage (Vg) curve. When phosphate buffered saline (PBS) was present in the channel, the additional minimum was present at a Vg lower than the original Dirac point and shifted with time when exosomes were introduced into the channel. This shift of the minimum from the PBS reference point reached saturation after 30 minutes and was observed for multiple exosome concentrations. Upon conjugation with an isotype control, sensor response to the highest concentration of exosomes was negligible in comparison to that with anti-CD63 antibody, indicating that the functionalised gFET can specifically detect exosomes at least down to 0.1 μg/mL and is sensitive to concentration. Such a gFET biosensor has not been used before for exosome sensing and could be an effective tool for the liquid-biopsy detection of exosomes as biomarkers for early-stage identification of diseases such as cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Large-Area Synthesis of High-Quality and Uniform Graphene Films on Copper Foils
Li, X., Cai, W., An, J., Kim, S., Nah, J., Yang, D., Piner, R., Velamakanni, A., Jung, I., Tutuc, E., et al. (2009) · Science · doi:10.1126/science.1171245 · Cited by 11,220
Isolation and Characterization of Exosomes from Cell Culture Supernatants and Biological Fluids
Théry, C., Amigorena, S., Raposo, G., & Clayton, A. (2006) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0322s30 · Cited by 5,766
Electronic transport in two-dimensional graphene
Das Sarma, S., Adam, S., Hwang, E. H., & Rossi, E. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.407 · Cited by 3,447
Glypican-1 identifies cancer exosomes and detects early pancreatic cancer
Melo, S. A., Luecke, L. B., Kahlert, C., Fernandez, A. F., Gammon, S. T., Kaye, J., LeBleu, V. S., Mittendorf, E. A., Weitz, J., Rahbari, N., et al. (2015) · Nature · doi:10.1038/nature14581 · Cited by 2,880
Vlassov, A. V., Magdaleno, S., Setterquist, R., & Conrad, R. (2012) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2012.03.017 · Cited by 1,930
The biology and function of exosomes in cancer
Kalluri, R. (2016) · Journal of Clinical Investigation · doi:10.1172/jci81135 · Cited by 1,849
A review of chemical vapour deposition of graphene on copper
Mattevi, C., Kim, H., & Chhowalla, M. (2011) · J. Mater. Chem. · doi:10.1039/c0jm02126a · Cited by 1,452
Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor
Im, H., Shao, H., Park, Y. I., Peterson, V. M., Castro, C. M., Weissleder, R., & Lee, H. (2014) · Nature Biotechnology · doi:10.1038/nbt.2886 · Cited by 1,321
Defect characterization in graphene and carbon nanotubes using Raman spectroscopy
Dresselhaus, M. S., Jorio, A., Souza Filho, A. G., & Saito, R. (2010) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2010.0213 · Cited by 779
Cited by
Applications of carbon-based conductive nanomaterials in biosensors
Eivazzadeh-Keihan, R., Bahojb Noruzi, E., Chidar, E., Jafari, M., Davoodi, F., Kashtiaray, A., Ghafori Gorab, M., Masoud Hashemi, S., Javanshir, S., Ahangari Cohan, R., et al. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.136183 · Cited by 365
Advances in Biosensors and Diagnostic Technologies Using Nanostructures and Nanomaterials
Welch, E. C., Powell, J. M., Clevinger, T. B., Fairman, A. E., & Shukla, A. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104126 · Cited by 240
Graphene field-effect transistors as bioanalytical sensors: design, operation and performance
Béraud, A., Sauvage, M., Bazán, C. M., Tie, M., Bencherif, A., & Bouilly, D. (2021) · The Analyst · doi:10.1039/d0an01661f · Cited by 210
Engineered two-dimensional nanomaterials: an emerging paradigm for water purification and monitoring
Zeng, M., Chen, M., Huang, D., Lei, S., Zhang, X., Wang, L., & Cheng, Z. (2021) · Materials Horizons · doi:10.1039/d0mh01358g · Cited by 178
MXene–Graphene Field-Effect Transistor Sensing of Influenza Virus and SARS-CoV-2
Li, Y., Peng, Z., Holl, N. J., Hassan, M. R., Pappas, J. M., Wei, C., Izadi, O. H., Wang, Y., Dong, X., Wang, C., et al. (2021) · ACS Omega · doi:10.1021/acsomega.0c05421 · Cited by 167
Metadata
- Authors
- Kwong Hong Tsang, D., Lieberthal, T. J., Watts, C., Dunlop, I. E., Ramadan, S., del Rio Hernandez, A. E., & Klein, N.
- Venue
- Scientific Reports
- Published
- 2019-09-26
- Volume
- 9
- Issue
- 1
- Pages
- 13946-13946
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2976079615
- Cited by
- 237
- References
- 40
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.