Antibacterial effects of low-temperature plasma generated by atmospheric-pressure plasma jet are mediated by reactive oxygen species
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Emergence and spread of antibiotic resistance calls for development of non-chemical treatment options for bacterial infections. Plasma medicine applies low-temperature plasma (LTP) physics to address biomedical problems such as wound healing and tumor suppression. LTP has also been used for surface disinfection. However, there is still much to be learned regarding the effectiveness of LTP on bacteria in suspension in liquids, and especially on porous surfaces. We investigated the efficacy of LTP treatments against bacteria using an atmospheric-pressure plasma jet and show that LTP treatments have the ability to inhibit both gram-positive (S. aureus) and gram-negative (E. coli) bacteria on solid and porous surfaces. Additionally, both direct LTP treatment and plasma-activated media were effective against the bacteria suspended in liquid culture. Our data indicate that reactive oxygen species are the key mediators of the bactericidal effects of LTP and hydrogen peroxide is necessary but not sufficient for antibacterial effects. In addition, our data suggests that bacteria exposed to LTP do not develop resistance to further treatment with LTP. These findings suggest that this novel atmospheric-pressure plasma jet could be used as a potential alternative to antibiotic treatments in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Antioxidant Properties of Probiotic Bacteria
Wang, Y., Wu, Y., Wang, Y., Xu, H., Mei, X., Yu, D., Wang, Y., & Li, W. (2017) · Nutrients · doi:10.3390/nu9050521 · Cited by 917 · cited 1×
“There have been multiple reports indicating variation in antioxidant machinery in different bacterial strains [42] [43] [44] [45] .”
BackgroundThe potential of nitric oxide releasing therapies as antimicrobial agents
Schairer, D. O., Chouake, J. S., Nosanchuk, J. D., & Friedman, A. J. (2012) · Virulence · doi:10.4161/viru.20328 · Cited by 573 · cited 2×
“Since our APPJ system incorporated gaseous oxygen into the carrier gas, and we observed the transient nature of the bactericidal mediators in PAM, we hypothesized that ROS/RNS may be generated in the media following LTP treatment and may be responsible for the killing of bacteria.”
BackgroundEstimating the burden of antimicrobial resistance: a systematic literature review
Naylor, N. R., Atun, R., Zhu, N., Kulasabanathan, K., Silva, S., Chatterjee, A., Knight, G. M., & Robotham, J. V. (2018) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-018-0336-y · Cited by 568 · cited 1×
“Finally, aside from the medical obstacles posed by treatment of patients with bacterial infections, the spread of antibiotic resistance also results in significant excess healthcare system costs and economic burdens with estimates of up to $1 billion per year and $3 trillion in worldwide gross domestic product losses…”
BackgroundAtmospheric-pressure plasma sources: Prospective tools for plasma medicine
Weltmann, K. D., Kindel, E., von Woedtke, T., Hähnel, M., Stieber, M., & Brandenburg, R. (2010) · Pure and Applied Chemistry · doi:10.1351/pac-con-09-10-35 · Cited by 449 · cited 1×
“The well-reported use of plasmas for sterilization of non-biomedical materials has presented an opportunity for plasma medicine to expand into the realm of antiseptics [8] [9] [10] [11] .”
BackgroundWhy do bacteria use so many enzymes to scavenge hydrogen peroxide?
Mishra, S., & Imlay, J. (2012) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2012.04.014 · Cited by 411 · cited 1×
“There have been multiple reports indicating variation in antioxidant machinery in different bacterial strains [42] [43] [44] [45] .”
BackgroundShen, J., Tian, Y., Li, Y., Ma, R., Zhang, Q., Zhang, J., & Fang, J. (2016) · Scientific Reports · doi:10.1038/srep28505 · Cited by 410 · cited 2×
“This hypothesis is supported by the previous observations that plasma -activated media (PAM), media exposed to a source of plasma and then introduced to a target sample, was effective as an aqueous disinfectant and may also have tumoricidal effects [13] [14] [15] [16] 26, 27 .”
BackgroundMethodMicrobiological interactions with cold plasma
Bourke, P., Ziuzina, D., Han, L., Cullen, P. J., & Gilmore, B. F. (2017) · Journal of Applied Microbiology · doi:10.1111/jam.13429 · Cited by 405 · cited 1×
“Additionally, there are no indications of the evolution of bacterial resistance to the plasma treatment [33] [34] [35] [36] .”
BackgroundNon‐Thermal Plasma in Contact with Water: The Origin of Species
Gorbanev, Y. Y., O’Connell, D., & Chechik, V. (2016) · Chemistry - A European Journal · doi:10.1002/chem.201503771 · Cited by 373
Shrestha, P., Cooper, B. S., Coast, J., Oppong, R., Do Thi Thuy, N., Phodha, T., Celhay, O., Guerin, P. J., Wertheim, H., & Lubell, Y. (2018) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-018-0384-3 · Cited by 288
Chauvin, J., Judée, F., Yousfi, M., Vicendo, P., & Merbahi, N. (2017) · Scientific Reports · doi:10.1038/s41598-017-04650-4 · Cited by 281 · cited 2×
“It has been shown that small amounts of UV radiation are emitted by LTP devices, but it is thought that the dose is not sufficient to cause damage to the targeted treatment sample and that the majority of the VUV photons (<180 nm) are absorbed into the air 29, 38 .”
BackgroundLee, K.-N., Paek, K.-H., Ju, W.-T., & Lee, Y. (2006) · PubMed · Cited by 252
Antibacterial Effects of Hydrogen Peroxide and Methods for Its Detection and Quantitation
Juven, B. J., & Pierson, M. D. (1996) · Journal of Food Protection · doi:10.4315/0362-028x-59.11.1233 · Cited by 245 · cited 1×
“However, H 2 O 2 can absorb large amounts of UV energy at short wavelengths, resulting in its dissociation into highly reactive, antibacterial hydroxyl radicals 28, 29, [39] [40] [41] .”
BackgroundMicrobial inactivation using plasma-activated water obtained by gliding electric discharges
Kamgang-Youbi, G., Herry, J.-M., Meylheuc, T., Brisset, J.-L., Bellon-Fontaine, M.-N., Doubla, A., & Naïtali, M. (2009) · Letters in Applied Microbiology · doi:10.1111/j.1472-765x.2008.02476.x · Cited by 226 · cited 2×
“This hypothesis is supported by the previous observations that plasma -activated media (PAM), media exposed to a source of plasma and then introduced to a target sample, was effective as an aqueous disinfectant and may also have tumoricidal effects [13] [14] [15] [16] 26, 27 .”
BackgroundMethodLu, H., Patil, S., Keener, K. M., Cullen, P. J., & Bourke, P. (2014) · Journal of Applied Microbiology · doi:10.1111/jam.12426 · Cited by 219
Cold Plasmas for Biofilm Control: Opportunities and Challenges
Gilmore, B. F., Flynn, P. B., O’Brien, S., Hickok, N., Freeman, T., & Bourke, P. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.03.007 · Cited by 194 · cited 1×
“Additionally, there are no indications of the evolution of bacterial resistance to the plasma treatment [33] [34] [35] [36] .”
BackgroundTwo sources of endogenous hydrogen peroxide in Escherichia coli
Korshunov, S., & Imlay, J. A. (2010) · Molecular Microbiology · doi:10.1111/j.1365-2958.2010.07059.x · Cited by 182
Hertzberger, R., Arents, J., Dekker, H. L., Pridmore, R. D., Gysler, C., Kleerebezem, M., & de Mattos, M. J. T. (2014) · Applied and Environmental Microbiology · doi:10.1128/aem.04272-13 · Cited by 182
Gas plasma sterilization of microorganisms and mechanisms of action
SHINTANI, H., SAKUDO, A., BURKE, P., & McDONNELL, G. (2010) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2010.136 · Cited by 170 · cited 2×
“The well-reported use of plasmas for sterilization of non-biomedical materials has presented an opportunity for plasma medicine to expand into the realm of antiseptics [8] [9] [10] [11] .”
BackgroundEvaluation of the effects of a plasma activated medium on cancer cells
Mohades, S., Laroussi, M., Sears, J., Barekzi, N. A., & Razavi, H. (2015) · Physics of Plasmas · doi:10.1063/1.4933367 · Cited by 149
Park, J. H., Kumar, N., Park, D. H., Yusupov, M., Neyts, E. C., Verlackt, C. C. W., Bogaerts, A., Kang, M. H., Uhm, H. S., Choi, E. H., et al. (2015) · Scientific Reports · doi:10.1038/srep13849 · Cited by 110
Test for bacterial resistance build-up against plasma treatment
Zimmermann, J. L., Shimizu, T., Schmidt, H.-U., Li, Y., Morfill, G. E., & Isbary, G. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/7/073037 · Cited by 107 · cited 1×
“Additionally, there are no indications of the evolution of bacterial resistance to the plasma treatment [33] [34] [35] [36] .”
BackgroundMechanisms of Plasma Medicine: Coupling Plasma Physics, Biochemistry, and Biology
Graves, D. B. (2017) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2017.2710880 · Cited by 105
Joh, H. M., Choi, J. Y., Kim, S. J., Chung, T. H., & Kang, T. (2014) · Scientific Reports · doi:10.1038/srep06638 · Cited by 101
Mai‐Prochnow, A., Bradbury, M. I., Ostrikov, K., & Murphy, A. B. (2015) · PLoS ONE · doi:10.1371/journal.pone.0130373 · Cited by 96 · cited 1×
“More importantly, there are only a few studies that have investigated the benefits of either APPJ or DBD configurations in treating drug-resistant bacteria, particularly for in vivo settings [9] [10] [11] [12] [15] [16] [17] [18] [19] .”
BackgroundDJ-1/PARK7 Impairs Bacterial Clearance in Sepsis
Amatullah, H., Shan, Y., Beauchamp, B. L., Gali, P. L., Gupta, S., Maron‐Gutierrez, T., Speck, E. R., Fox‐Robichaud, A., Tsang, J. L. Y., Mei, S. H. J., et al. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0730oc · Cited by 94
UV-Hydrogen Peroxide Processes
Mierzwa, J. C., Rodrigues, R., & Teixeira, A. C. S. C. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-810499-6.00002-4 · Cited by 83 · cited 1×
“However, H 2 O 2 can absorb large amounts of UV energy at short wavelengths, resulting in its dissociation into highly reactive, antibacterial hydroxyl radicals 28, 29, [39] [40] [41] .”
BackgroundInactivation of Microorganisms and Endotoxins by Low Temperature Nitrogen Gas Plasma Exposure
Shintani, H., Shimizu, N., Imanishi, Y., Sekiya, T., TAMAZAWA, K., TANIGUCHI, A., & Kido, N. (2007) · Biocontrol Science · doi:10.4265/bio.12.131 · Cited by 81 · cited 2×
“The well-reported use of plasmas for sterilization of non-biomedical materials has presented an opportunity for plasma medicine to expand into the realm of antiseptics [8] [9] [10] [11] .”
BackgroundEffect of Gas-Plasma Sterilization on the Osteoinductive Capacity of Demineralized Bone Matrix
Ferreira, S. D., Dernell, W. S., Powers, B. E., Schochet, R. A., Kuntz, C. A., Withrow, S. J., & Wilkins, R. M. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200107000-00032 · Cited by 43
Liquid dynamics in response to an impinging low-temperature plasma jet
Brubaker, T. R., Ishikawa, K., Kondo, H., Tsutsumi, T., Hashizume, H., Tanaka, H., Knecht, S. D., Bilén, S. G., & Hori, M. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aaf460 · Cited by 33
Self-citationSynergistic effects of plasma-activated medium and chemotherapeutic drugs in cancer treatment
Chen, C., Cheng, Y., & Cheng, Y.-J. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aaafc4 · Cited by 32 · cited 2×
“This hypothesis is supported by the previous observations that plasma -activated media (PAM), media exposed to a source of plasma and then introduced to a target sample, was effective as an aqueous disinfectant and may also have tumoricidal effects [13] [14] [15] [16] 26, 27 .”
BackgroundMethodSazykin, I. S., Sazykina, M. A., Khmelevtsova, L. E., Seliverstova, E. Y., Karchava, S., & Zhuravleva, M. V. (2018) · Archives of Microbiology · doi:10.1007/s00203-018-1516-0 · Cited by 23 · cited 1×
“There have been multiple reports indicating variation in antioxidant machinery in different bacterial strains [42] [43] [44] [45] .”
BackgroundPresence of antioxidant materials in bacteria
Smith, J. L., & Alford, J. A. (1970) · Lipids · doi:10.1007/bf02531970 · Cited by 18 · cited 1×
“There have been multiple reports indicating variation in antioxidant machinery in different bacterial strains [42] [43] [44] [45] .”
Background(2015) · PubMed Central
Cited by
Direct and Indirect Bactericidal Effects of Cold Atmospheric-Pressure Microplasma and Plasma Jet
Yahaya, A. G., Okuyama, T., Kristof, J., Blajan, M. G., & Shimizu, K. (2021) · Molecules · doi:10.3390/molecules26092523 · Cited by 51
Wang, Y., Liu, Y., Zhao, Y., Sun, Y., Duan, M., Wang, H., Dai, R., Liu, Y., Li, X., & Jia, F. (2023) · Food Research International · doi:10.1016/j.foodres.2023.113204 · Cited by 38
Metadata
- Authors
- Nicol, M. J., Brubaker, T. R., Honish, B. J., Simmons, A. N., Kazemi, A., Geissel, M. A., Whalen, C. T., Siedlecki, C. A., Bilén, S. G., Knecht, S. D., & Kirimanjeswara, G. S.
- Venue
- Scientific Reports
- Published
- 2020-02-20
- Volume
- 10
- Issue
- 1
- Pages
- 3066-3066
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3007432386
- Cited by
- 193
- References
- 34
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.