A deep learning methodology for improved breast cancer diagnosis using multiparametric MRI
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Multiparametric magnetic resonance imaging (mpMRI) has been shown to improve radiologists’ performance in the clinical diagnosis of breast cancer. This machine learning study develops a deep transfer learning computer-aided diagnosis (CADx) methodology to diagnose breast cancer using mpMRI. The retrospective study included clinical MR images of 927 unique lesions from 616 women. Each MR study included a dynamic contrast-enhanced (DCE)-MRI sequence and a T2-weighted (T2w) MRI sequence. A pretrained convolutional neural network (CNN) was used to extract features from the DCE and T2w sequences, and support vector machine classifiers were trained on the CNN features to distinguish between benign and malignant lesions. Three methods that integrate the sequences at different levels (image fusion, feature fusion, and classifier fusion) were investigated. Classification performance was evaluated using the receiver operating characteristic (ROC) curve and compared using the DeLong test. The single-sequence classifiers yielded areas under the ROC curves (AUCs) [95% confidence intervals] of AUC DCE = 0.85 [0.82, 0.88] and AUC T2w = 0.78 [0.75, 0.81]. The multiparametric schemes yielded AUC ImageFusion = 0.85 [0.82, 0.88], AUC FeatureFusion = 0.87 [0.84, 0.89], and AUC ClassifierFusion = 0.86 [0.83, 0.88]. The feature fusion method statistically significantly outperformed using DCE alone (P < 0.001). In conclusion, the proposed deep transfer learning CADx method for mpMRI may improve diagnostic performance by reducing the false positive rate and improving the positive predictive value in breast imaging interpretation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Very Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148 · cited 1×
“Through transfer learning, CNN features were extracted separately from the ROIs of the DCE subtraction MIPs and the ROIs of the T2w center slices using the publicly available VGG19 model 15 , pretrained on Table 1.”
MethodImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526
Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond
Schölkopf, B., & Smola, A. J. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/4175.001.0001 · Cited by 11,703
Shin, H.-C., Roth, H. R., Gao, M., Lu, L., Xu, Z., Nogues, I., Yao, J., Mollura, D., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528162 · Cited by 5,759
DeCAF: A Deep Convolutional Activation Feature for Generic Visual Recognition
Donahue, J., Jia, Y., Vinyals, O., Hoffman, J., Zhang, N., Tzeng, E., & Darrell, T. (2013) · arXiv · doi:10.48550/arxiv.1310.1531 · Cited by 4,019
Better Bootstrap Confidence Intervals
Efron, B. (1987) · Journal of the American Statistical Association · doi:10.1080/01621459.1987.10478410 · Cited by 3,364 · cited 1×
“Standard errors and 95% confidence intervals (CIs) of the AUCs were calculated by bootstrapping the posterior PMs (2000 bootstrap samples) 25 .”
MethodConvolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
Greenspan, H., van Ginneken, B., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553401 · Cited by 1,700
Jolliffe, I. (2014) · Wiley StatsRef: Statistics Reference Online · doi:10.1002/9781118445112.stat06472 · Cited by 1,221
Jolliffe, I. (2011) · International Encyclopedia of Statistical Science · doi:10.1007/978-3-642-04898-2_455 · Cited by 1,206
Kuhl, C. K., Schrading, S., Leutner, C. C., Morakkabati-Spitz, N., Wardelmann, E., Fimmers, R., Kuhn, W., & Schild, H. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2004.00.4960 · Cited by 1,147
Automated multi-modality image registration based on information theory
Collignon, A. M. F., Maes, F., Delaere, D., Vandermeulen, D., Suetens, P., & Marchal, G. (1995) · Computational imaging and vision · Cited by 1,013
Metz, C. E., Herman, B. A., & Shen, J.-H. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980515)17:9<1033::aid-sim784>3.0.co;2-z · Cited by 793
Sun, X., & Xu, W. (2014) · IEEE Signal Processing Letters · doi:10.1109/lsp.2014.2337313 · Cited by 630
Huynh, B. Q., Li, H., & Giger, M. L. (2016) · Journal of Medical Imaging · doi:10.1117/1.jmi.3.3.034501 · Cited by 539
Self-citationAntropova, N., Huynh, B. Q., & Giger, M. L. (2017) · Medical Physics · doi:10.1002/mp.12453 · Cited by 389
Chen, W., Giger, M. L., & Bick, U. (2006) · Academic Radiology · doi:10.1016/j.acra.2005.08.035 · Cited by 357
Self-citationTruhn, D., Schrading, S., Haarburger, C., Schneider, H., Merhof, D., & Kuhl, C. (2019) · Radiology · doi:10.1148/radiol.2018181352 · Cited by 273
“Proper” Binormal ROC Curves: Theory and Maximum-Likelihood Estimation
Metz, C. E., & Pan, X. (1999) · Journal of Mathematical Psychology · doi:10.1006/jmps.1998.1218 · Cited by 273
A review of optimization methodologies in support vector machines
Shawe-Taylor, J., & Sun, S. (2011) · Neurocomputing · doi:10.1016/j.neucom.2011.06.026 · Cited by 256
Breast Image Analysis for Risk Assessment, Detection, Diagnosis, and Treatment of Cancer
Giger, M. L., Karssemeijer, N., & Schnabel, J. A. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152416 · Cited by 206
Self-citationKuhl, C. K., Klaschik, S., Mielcarek, P., Gieseke, J., Wardelmann, E., & Schild, H. H. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199902)9:2<187::aid-jmri6>3.0.co;2-2 · Cited by 169
Ahn, S., Park, S. H., & Lee, K. H. (2013) · Radiology · doi:10.1148/radiol.12120725 · Cited by 159
Parekh, V. S., & Jacobs, M. A. (2017) · npj Breast Cancer · doi:10.1038/s41523-017-0045-3 · Cited by 158
Clinical role of breast MRI now and going forward
Leithner, D., Wengert, G., Helbich, T. H., Thakur, S. B., Ochoa‐Albiztegui, R. E., Morris, E. A., & Pinker, K. (2017) · Clinical Radiology · doi:10.1016/j.crad.2017.10.021 · Cited by 136
Dalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Santamaría, G., Velasco, M., Bargalló, X., Caparrós, X., Farrus, B., & Fernández, P. L. (2010) · Radiographics · doi:10.1148/rg.302095044 · Cited by 103
Antropova, N. O., Abé, H., & Giger, M. L. (2018) · Journal of medical imaging · doi:10.1117/1.jmi.5.1.014503 · Cited by 100
Self-citationUsing T2-Weighted Sequences to More Accurately Characterize Breast Masses Seen on MRI
Westra, C., Dialani, V. M., Mehta, T. S., & Eisenberg, R. L. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11266 · Cited by 87
Ashburner, J., & Friston, K. J. (2007) · Elsevier eBooks · doi:10.1016/b978-012372560-8/50004-8 · Cited by 71
Bhooshan, N., Giger, M. L., Li, L., Li, H., Marquez, A., Shimauchi, A., & Newstead, G. M. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22800 · Cited by 40
Self-citationHorsch, K., Giger, M. L., & Metz, C. E. (2008) · Academic Radiology · doi:10.1016/j.acra.2008.04.022 · Cited by 23
Self-citation
Cited by
A Review of Deep Learning on Medical Image Analysis
Wang, J., Zhu, H., Wang, S.-H., & Zhang, Y.-D. (2021) · Mobile Networks and Applications · doi:10.1007/s11036-020-01672-7 · Cited by 303
Machine learning in clinical decision making
Adlung, L., Cohen, Y., Mor, U., & Elinav, E. (2021) · Med · doi:10.1016/j.medj.2021.04.006 · Cited by 282
Li, Y., El Habib Daho, M., Conze, P.-H., Zeghlache, R., Le Boité, H., Tadayoni, R., Cochener, B., Lamard, M., & Quellec, G. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108635 · Cited by 274
“In addition to using a single multimodal fusion method, multiple fusion methods can be combined (Tang et al., 2022; Li et al., 2023; Hu et al., 2020; Wang et al., 2022).”
BackgroundMethodTransfer Learning in Breast Cancer Diagnoses via Ultrasound Imaging
Ayana, G., Dese, K., & Choe, S.-W. (2021) · Cancers · doi:10.3390/cancers13040738 · Cited by 174
“The area under the receiver operating characteristic (ROC) curve and AUC were calculated to evaluate breast cancer classification performance [96,97].”
MethodElyan, E., Vuttipittayamongkol, P., Johnston, P., Martin, K., McPherson, K., Moreno-García, C. F., Jayne, C., & Mostafa Kamal Sarker, M. (2022) · Artificial Intelligence Surgery · doi:10.20517/ais.2021.15 · Cited by 161
Metadata
- Authors
- Hu, Q., Whitney, H. M., & Giger, M. L.
- Venue
- Scientific Reports
- Published
- 2020-06-29
- Volume
- 10
- Issue
- 1
- Pages
- 10536-10536
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3037765194
- Cited by
- 183
- References
- 34
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.