The reliability of machine learning models can be compromised when trained on low quality data. Many large-scale medical imaging datasets contain low quality labels extracted from sources such as medical reports. Moreover, images within a dataset may have heterogeneous quality due to artifacts and biases arising from equipment or measurement errors. Therefore, algorithms that can automatically identify low quality data are highly desired. In this study, we used data Shapley, a data valuation metric, to quantify the value of training data to the performance of a pneumonia detection algorithm in a large chest X-ray dataset. We characterized the effectiveness of data Shapley in identifying low quality versus valuable data for pneumonia detection. We found that removing training data with high Shapley values decreased the pneumonia detection performance, whereas removing data with low Shapley values improved the model performance. Furthermore, there were more mislabeled examples in low Shapley value data and more true pneumonia cases in high Shapley value data. Our results suggest that low Shapley value indicates mislabeled or poor quality images, whereas high Shapley value indicates data that are valuable for pneumonia detection. Our method can serve as a framework for using data Shapley to denoise large-scale medical imaging datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
A guide to deep learning in healthcare
Esteva, A., Robicquet, A., Ramsundar, B., Kuleshov, V., DePristo, M., Chou, K., Cui, C., Corrado, G., Thrun, S., & Dean, J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0316-z · Cited by 5,312
Wang, X., Peng, Y., Lu, L., Lu, Z., Bagheri, M., & Summers, R. M. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.369 · Cited by 4,616
MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports
Johnson, A. E. W., Pollard, T. J., Berkowitz, S. J., Greenbaum, N. R., Lungren, M. P., Deng, C.-Y., Mark, R. G., & Horng, S. (2019) · Scientific Data · doi:10.1038/s41597-019-0322-0 · Cited by 1,816
Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002683 · Cited by 1,719
Rajpurkar, P., Irvin, J., Ball, R. L., Zhu, K., Yang, B., Mehta, H., Duan, T., Ding, D., Bagul, A., Langlotz, C. P., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002686 · Cited by 1,449
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153
Self-citationPreparing Medical Imaging Data for Machine Learning
Willemink, M. J., Koszek, W. A., Hardell, C., Wu, J., Fleischmann, D., Harvey, H., Folio, L. R., Summers, R. M., Rubin, D. L., & Lungren, M. P. (2020) · Radiology · doi:10.1148/radiol.2020192224 · Cited by 1,020
Self-citationMedical Image Denoising Using Convolutional Denoising Autoencoders
Gondara, L. (2016) · 2016 IEEE 16th International Conference on Data Mining Workshops (ICDMW) · doi:10.1109/icdmw.2016.0041 · Cited by 737 · cited 1×
“Furthermore, denoising medical images has been studied extensively, ranging from classical techniques such as filtering 28,29 and wavelet transformation 30,31 to more recent deep learning methods 32–34 .”
Method
Cited by
Generalization—a key challenge for responsible AI in patient-facing clinical applications
Goetz, L., Seedat, N., Vandersluis, R., & van der Schaar, M. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01127-3 · Cited by 124
When Does Contrastive Visual Representation Learning Work?
Cole, E., Yang, X., Wilber, K., Aodha, O. M., & Belongie, S. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.01434 · Cited by 105
Bloch, L., Friedrich, C. M., & Initiative, F. T. A. D. N. (2021) · Alzheimer's Research & Therapy · doi:10.1186/s13195-021-00879-4 · Cited by 68
“This article transferred the method described in Tang et al. [37] to early AD detection.”
MethodQuality gaps in public pancreas imaging datasets: Implications & challenges for AI applications
Suman, G., Patra, A., Korfiatis, P., Majumder, S., Chari, S. T., Truty, M. J., Fletcher, J. G., & Goenka, A. H. (2021) · Pancreatology · doi:10.1016/j.pan.2021.03.016 · Cited by 41
(2021) · doi:10.1145/3450439.3451862 · Cited by 28
“Prior work has found that report labels may not accurately reflect the visual content of medical images [18, 19, 29].”
Background
Metadata
- Authors
- Tang, S., Ghorbani, A., Yamashita, R., Rehman, S., Dunnmon, J. A., Zou, J., & Rubin, D. L.
- Venue
- Scientific Reports
- Published
- 2021-04-16
- Volume
- 11
- Issue
- 1
- Pages
- 8366-8366
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3092703718
- Cited by
- 76
- References
- 16
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Data valuation for medical imaging using Shapley value and application to a large-scale chest X-ray dataset. https://app.cochat.ai/papers/10.1038/s41598-021-87762-2
- The paper
- Tang, S., Ghorbani, A., Yamashita, R., Rehman, S., Dunnmon, J. A., Zou, J., & Rubin, D. L. (2021). Data valuation for medical imaging using Shapley value and application to a large-scale chest X-ray dataset. Scientific Reports. https://doi.org/10.1038/s41598-021-87762-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.