CoChat

Highly specific and ultrasensitive plasma test detects Abeta(1–42) and Abeta(1–40) in Alzheimer’s disease

Open access
Thijssen, Elisabeth H., Verberk, Inge M. W., Vanbrabant, Jeroen, Koelewijn, Anne, Heijst, Hans, Scheltens, Philip, van der Flier, Wiesje, Vanderstichele, Hugo, Stoops, Erik, Teunissen, Charlotte E. · 2021 · Scientific Reports
Cited by 86

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Plasma biomarkers that reflect specific amyloid beta (Abeta) proteoforms provide an insight in the treatment effects of Alzheimer’s disease (AD) therapies. Our aim was to develop and validate ready-to-use Simoa ‘Amyblood’ assays that measure full length Abeta 1-42 and Abeta 1-40 and compare their performance with two commercial assays. Linearity, intra- and inter-assay %CV were compared between Amyblood, Quanterix Simoa triplex, and Euroimmun ELISA. Sensitivity and selectivity were assessed for Amyblood and the Quanterix triplex. Clinical performance was assessed in CSF biomarker confirmed AD (n = 43, 68 ± 6 years) and controls (n = 42, 62 ± 5 years). Prototype and Amyblood showed similar calibrator curves and differentiation (20 AD vs 20 controls, p < 0.001). Amyblood, Quanterix triplex, and ELISA showed similar linearity (96%-122%) and intra-assay %CVs (≤ 3.1%). A minor non-specific signal was measured with Amyblood of + 2.4 pg/mL Abeta 1-42 when incubated with 60 pg/mL Abeta 1-40. A substantial non-specific signal of + 24.7 pg/mL Abeta x-42 was obtained when 40 pg/mL Abeta 3-42 was measured with the Quanterix triplex. Selectivity for Abeta 1-42 at physiological Abeta 1-42 and Abeta 1-40 concentrations was 125% for Amyblood and 163% for Quanterix. Amyblood and Quanterix ratios (p < 0.001) and ELISA Abeta 1-42 concentration (p = 0.025) could differentiate AD from controls. We successfully developed and upscaled a prototype to the Amyblood assays with similar technical and clinical performance as the Quanterix triplex and ELISA, but better specificity and selectivity than the Quanterix triplex assay. These results suggest leverage of this specific assay for monitoring treatment response in trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-021-89004-x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 86

Metadata

Authors
Thijssen, E. H., Verberk, I. M. W., Vanbrabant, J., Koelewijn, A., Heijst, H., Scheltens, P., van der Flier, W., Vanderstichele, H., Stoops, E., & Teunissen, C. E.
Venue
Scientific Reports
Published
2021-05-06
Volume
11
Issue
1
Pages
9736-9736
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3115865218
Cited by
86
References
18
FWCI
8.62
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly specific and ultrasensitive plasma test detects Abeta(1–42) and Abeta(1–40) in Alzheimer’s disease. https://app.cochat.ai/papers/10.1038/s41598-021-89004-x
The paper
Thijssen, E. H., Verberk, I. M. W., Vanbrabant, J., Koelewijn, A., Heijst, H., Scheltens, P., van der Flier, W., Vanderstichele, H., Stoops, E., & Teunissen, C. E. (2021). Highly specific and ultrasensitive plasma test detects Abeta(1–42) and Abeta(1–40) in Alzheimer’s disease. Scientific Reports. https://doi.org/10.1038/s41598-021-89004-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.