The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Effects of MRI scanner manufacturers in classification tasks with deep learning models
Open accessAbstract
Deep learning has become a leading subset of machine learning and has been successfully employed in diverse areas, ranging from natural language processing to medical image analysis. In medical imaging, researchers have progressively turned towards multi-center neuroimaging studies to address complex questions in neuroscience, leveraging larger sample sizes and aiming to enhance the accuracy of deep learning models. However, variations in image pixel/voxel characteristics can arise between centers due to factors including differences in magnetic resonance imaging scanners. Such variations create challenges, particularly inconsistent performance in machine learning-based approaches, often referred to as domain shift, where the trained models fail to achieve satisfactory or improved results when confronted with dissimilar test data. This study analyzes the performance of multiple disease classification tasks using multi-center MRI data obtained from three widely used scanner manufacturers (GE, Philips, and Siemens) across several deep learning-based networks. Furthermore, we investigate the efficacy of mitigating scanner vendor effects using ComBat-based harmonization techniques when applied to multi-center datasets of 3D structural MR images. Our experimental results reveal a substantial decline in classification performance when models trained on one type of scanner manufacturer are tested with data from different manufacturers. Moreover, despite applying ComBat-based harmonization, the harmonized images do not demonstrate any noticeable performance enhancement for disease classification tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“inconsistent feature distributions in multicenter imaging data resulting from technical heterogeneities—including differences in scanner manufacturers, magnetic field strengths (1.5T vs. 3T), and acquisition protocols—which compromise cross-site model generalizability (Kushol et al., 2023).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Kushol et al., 2023
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al. (2020) · arXiv · doi:10.48550/arxiv.2010.11929 · Cited by 47,472 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialPyTorch: An Imperative Style, High-Performance Deep Learning Library
Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., Antiga, L., et al. (2019) · arXiv · doi:10.48550/arxiv.1912.01703 · Cited by 31,473 · cited 1×
“The DL frameworks employed in our analysis are implemented using PyTorch 36”
MobileNetV2: Inverted Residuals and Linear Bottlenecks
Sandler, M., Howard, A., Zhu, M., Zhmoginov, A., & Chen, L.-C. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00474 · Cited by 28,755 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialProceedings of IEEE Conference on Computer Vision and Pattern Recognition
(1993) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1993.341010 · Cited by 14,265
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526 · cited 1×
“This task is achieved using the FreeSurfer program 27 (Command: mri_synthstrip -i input_image -o stripped_image ) 3 .”
ShuffleNet V2: Practical Guidelines for Efficient CNN Architecture Design
Ma, N., Zhang, X., Zheng, H.-T., & Sun, J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01264-9_8 · Cited by 7,356 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialN4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073 · cited 1×
“Subsequently, we perform N4 bias field correction using the SimpleITK library’s N4BiasFieldCorrec-tionImageFilter class to rectify low-frequency intensity non-uniformity in the MRI data 28 .”
Dimensionality reduction for visualizing single-cell data using UMAP
Becht, E., McInnes, L., Healy, J., Dutertre, C.-A., Kwok, I. W. H., Ng, L. G., Ginhoux, F., & Newell, E. W. (2019) · Nature Biotechnology · doi:10.1038/nbt.4314 · Cited by 5,358 · cited 1×
“Subsequently, we employ t-SNE (t-distributed Stochastic Neighbor Embedding) 37 and UMAP (Uniform Manifold Approximation and Projection) 38 techniques to visualize the data in a 2D space, using features generated by MRQy 39 .”
Research works printed but not linked: 1
- Van der Maaten, L. & Hinton, G. Visualizing data using t-sne. J. Mach. Learn. Res. 9, 896 (2008).
Cited by
The power of deep learning in simplifying feature selection for hepatocellular carcinoma: a review
Mostafa, G., Mahmoud, H. A., El‐Hafeez, T. A., & E.ElAraby, M. (2024) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-024-02682-1 · Cited by 103
“These CNN algorithms, trained on diverse imaging modalities such as ultrasound, computed tomography (CT) [39], and magnetic resonance imaging (MRI), have demonstrated exceptional performance in various tasks [40].”
MethodAhmed, N., Saha, A. K., Noman, M. A. A., Jim, J. R., Mridha, M. F., & Kabir, M. M. (2024) · Natural Language Processing Journal · doi:10.1016/j.nlp.2024.100112 · Cited by 69
A generalizable foundation model for analysis of human brain MRI
Tak, D., Garomsa, B. A., Zapaishchykova, A., Chaunzwa, T. L., Pardo, J. C., Ye, Z., Zielke, J., Ravipati, Y., Pai, S., Vajapeyam, S., et al. (2026) · Nature Neuroscience · doi:10.1038/s41593-026-02202-6 · Cited by 112
“Furthermore, magnetic resonance acquisition itself is subject to variability and noise, with a range of scanners (from 1.5 T to 7 T) and differing acquisition parameters (for example, echo time or relaxation time) 24 .”
Influentialde Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
Jia, W., Li, H., Ali, R. A., Shanbhogue, K., Masch, W. R., Aslam, A., Harris, D. T., Reeder, S. B., Dillman, J. R., & He, L. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01253-0 · Cited by 24
“For example, Kushol et al. found that harmonized images generated by the ComBat method fail to enhance the classification accuracy in most of their brain MR image classification applications [42].”
Metadata
- Authors
- Kushol, R., Parnianpour, P., Wilman, A. H., Kalra, S., & Yang, Y.-H.
- Affiliations
- University of Alberta (CA)
- Corresponding author
- Kushol, Rafsanjany
- Venue
- Scientific Reports
- Published
- 2023-10-05
- Volume
- 13
- Issue
- 1
- Pages
- 16791-16791
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC10556074
- OpenAlex
- W4387376141
- Cited by
- 54
- References
- 44
- Citations by year
- 2026: 21 · 2025: 22 · 2024: 11
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- ALS Society of Canada (100009017)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (501100002790)
- Fondation Brain Canada (100009408)
- Gouvernement du Canada | Canadian Institutes of Health Research (501100000024)
- Prime Minister Fellowship Bangladesh
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Keywords
- domain shift, multi-center MRI, structural MRI, combat, image harmonization, disease classification, neuroimaging, deep learning
- MeSH terms
- Machine Learning, Deep Learning, Magnetic Resonance Imaging, Natural Language Processing, Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of MRI scanner manufacturers in classification tasks with deep learning models. https://app.cochat.ai/papers/10.1038/s41598-023-43715-5
- The paper
- Kushol, R., Parnianpour, P., Wilman, A. H., Kalra, S., & Yang, Y.-H. (2023). Effects of MRI scanner manufacturers in classification tasks with deep learning models. Scientific Reports. https://doi.org/10.1038/s41598-023-43715-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.