Cited by 18Prosthetics and Rehabilitation RoboticsBalance, Gait, and Falls PreventionMuscle activation and electromyography studies

Ultra-lightweight robotic hip exoskeleton with anti-phase torque symmetry for enhanced walking efficiency

Open access
Lim, Bokman, Choi, Byungjune, Roh, Changhyun, Lee, Jewoo, Kim, Yong-Jae, Lee, Younbaek·2025·Scientific Reports

Abstract

This paper presents a novel robotic exoskeleton that is exceptionally lightweight and compact, while providing effective gait assistance. To maximize the system’s assistance-to-weight/size ratio, the design focuses on two key aspects of human gait mechanics: (1) the contribution of the hip joints to power generation, and (2) the symmetrical nature of hip flexion and extension torques during walking. Based on these principles, we developed a compact hip exoskeleton with a single actuator. This actuator simultaneously drives the hip joint in the sagittal plane, facilitating both flexion and extension during gait. An adaptive delayed output feedback controller was implemented, ensuring consistent performance across diverse walking conditions using a single rotational sensor and actuator. To evaluate the exoskeleton’s effectiveness, a 4-week outdoor walking exercise program was conducted with nine elderly participants. Their gait, balance, and muscle strength were measured before and after the program to assess improvements. Results showed significant improvements in walking speed (14.8% in the 10-m walk and 10.6% in the 6-min walk), as well as enhanced performance in the timed up-and-go test (24.5%) and the short physical performance battery test (18.7%). Ankle dorsiflexion and plantar flexion muscle strength increased by 75.45% and 45.8%, respectively. Additionally, metabolic measurements from three young adults indicated a 13.6 ± 3.2% reduction in the net metabolic cost of walking with the exoskeleton compared to walking without it. These results demonstrate that the single actuator-based hip exoskeleton offers effective gait assistance while maintaining a lightweight and compact design, highlighting its potential for widespread use in various applications.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-025-95599-2

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The torque-based flexion-extension symmetry of the hip joint provides key mechanical evidence for the design of gait assistance strategies, and when combined with exoskeleton systems, can achieve prediction and assistance of walking.

    “For example, the torque-based flexion-extension symmetry of the hip joint provides key mechanical evidence for the design of gait assistance strategies, and when combined with exoskeleton systems, can achieve prediction and assistance of walking (Fig. 4b) 84 .”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lim, B., Choi, B., Roh, C., Lee, J., Kim, Y.-J., & Lee, Y.
Affiliations
Korea University of Technology and Education (KR)
Corresponding author
Lim, Bokman
Venue
Scientific Reports
Published
2025-03-29
Volume
15
Issue
1
Pages
10850-10850
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4408960285
Cited by
18
References
42
Citations by year
2026: 15 · 2025: 3
FWCI
4.38
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Korea Institute for Robot Industry Advancement (2023-KIRIA-079)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
hip exoskeleton, gait assistance, walking efficiency, elderly gait, energy cost of walking, muscle strength, balance, walking speed
MeSH terms
Exoskeleton Device, Aged, Biomechanical Phenomena, Equipment Design, Female, Gait, Hip Joint, Humans, Male, Robotics, Walking, Torque, Muscle Strength

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review