Deep learning interpretation of echocardiograms
Open accessPublished version of a preprint
The DOI matches its Crossref record; 61 of the 67 references it cites were found in a registry or an index.
Abstract
Echocardiography uses ultrasound technology to capture high temporal and spatial resolution images of the heart and surrounding structures, and is the most common imaging modality in cardiovascular medicine. Using convolutional neural networks on a large new dataset, we show that deep learning applied to echocardiography can identify local cardiac structures, estimate cardiac function, and predict systemic phenotypes that modify cardiovascular risk but not readily identifiable to human interpretation. Our deep learning model, EchoNet, accurately identified the presence of pacemaker leads (AUC = 0.89), enlarged left atrium (AUC = 0.86), left ventricular hypertrophy (AUC = 0.75), left ventricular end systolic and diastolic volumes ( $${R}^{2}$$ R 2 = 0.74 and $${R}^{2}$$ R 2 = 0.70), and ejection fraction ( $${R}^{2}$$ R 2 = 0.50), as well as predicted systemic phenotypes of age ( $${R}^{2}$$ R 2 = 0.46), sex (AUC = 0.88), weight ( $${R}^{2}$$ R 2 = 0.56), and height ( $${R}^{2}$$ R 2 = 0.33). Interpretation analysis validates that EchoNet shows appropriate attention to key cardiac structures when performing human-explainable tasks and highlights hypothesis-generating regions of interest when predicting systemic phenotypes difficult for human interpretation. Machine learning on echocardiography images can streamline repetitive tasks in the clinical workflow, provide preliminary interpretation in areas with insufficient qualified cardiologists, and predict phenotypes challenging for human evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“EchoNet 69 -a deep learning model that can recognize cardiac structures, estimate function, and predict systemic phenotypes that are not readily identifiable to human interpretation-has recently furthered the field.”
From Deep learning-enabled medical computer vision (2021) · cites this paper as [69]
In the citing paper
“This method achieved an AUC-ROC of 0.75 and an F1 score of 0.57.”
From A Comprehensive Review on Synergy of Multi-Modal Data and AI Technologies in Medical Diagnosis (2024) · cites this paper as [142]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380 · cited 1×
“This architecture has strong performance on benchmark datasets like ILSVR2012 image recognition challenge (Imagenet) 40 and is computationally efficient compared to other networks 41 .”
BackgroundRethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
Focal Loss for Dense Object Detection
Lin, T.-Y., Goyal, P., Girshick, R., He, K., & Dollar, P. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.324 · Cited by 30,581 · cited 1×
“We investigated other variants of prediction loss (absolute loss, Huber loss 45 for regression and Focal loss 46 for classification), and they did not improve performance.”
MethodAdvances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362 · cited 3×
“Previous studies of deep learning on medical imaging focused on resource-intensive imaging modalities common in resourcerich settings(40,41) or sub-speciality imaging with focused indication.(12,13,16) These modalities often need retrospective annotation by experts as the clinical workflow often does not require Fig.”
BackgroundTensorFlow: A system for large-scale machine learning
Abadi, M., Barham, P., Chen, J., Chen, Z., Davis, A., Dean, J., Devin, M., Ghemawat, S., Irving, G., Isard, M., et al. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1605.08695 · Cited by 11,822
Self-citationRobust estimation of a location parameter
Huber, P. J. (1964) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177703732 · Cited by 7,228
Large-Scale Video Classification with Convolutional Neural Networks
Karpathy, A., Toderici, G., Shetty, S., Leung, T., Sukthankar, R., & Fei-Fei, L. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.223 · Cited by 6,354
Learning a Deep Convolutional Network for Image Super-Resolution
Dong, C., Loy, C. C., He, K., & Tang, X. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10593-2_13 · Cited by 5,494 · cited 1×
“8–11 Recent advances in machine learning suggest deep learning can identify human-identifiable characteristics as well as phenotypes unrecognized by human experts.”
BackgroundDeep Inside Convolutional Networks: Visualising Image Classification Models and Saliency Maps
Simonyan, K., Vedaldi, A., & Zisserman, A. (2013) · arXiv · doi:10.48550/arxiv.1312.6034 · Cited by 5,370
Inception-v4, Inception-ResNet and the Impact of Residual Connections on Learning
Szegedy, C., Ioffe, S., Vanhoucke, V., & Alemi, A. (2017) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v31i1.11231 · Cited by 4,636 · cited 1×
“We used the architecture based on Inception-Resnet-v1 10 to predict all of our phenotypes.”
MethodOn Pixel-Wise Explanations for Non-Linear Classifier Decisions by Layer-Wise Relevance Propagation
Bach, S., Binder, A., Montavon, G., Klauschen, F., Müller, K.-R., & Samek, W. (2015) · PLOS ONE · doi:10.1371/journal.pone.0130140 · Cited by 4,524
Axiomatic attribution for deep networks
Sundararajan, M., Taly, A., & Yan, Q. (2017) · arXiv · doi:10.48550/arxiv.1703.01365 · Cited by 4,087
Heidenreich, P. A., Trogdon, J. G., Khavjou, O. A., Butler, J., Dracup, K., Ezekowitz, M. D., Finkelstein, E. A., Hong, Y., Johnston, S. C., Khera, A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31820a55f5 · Cited by 3,208
Coudray, N., Ocampo, P. S., Sakellaropoulos, T., Narula, N., Snuderl, M., Fenyö, D., Moreira, A. L., Razavian, N., & Tsirigos, A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0177-5 · Cited by 2,930 · cited 2×
“Multiple recent medical examples outside of cardiology show convolutional neural network (CNN) algorithms can match or even exceed human experts in identifying and classifying diseases.(13,14) Echocardiography is a uniquely well-suited approach for the application of deep learning in cardiology.”
BackgroundLearning Important Features Through Propagating Activation Differences
Shrikumar, A., Greenside, P., & Kundaje, A. (2017) · arXiv · doi:10.48550/arxiv.1704.02685 · Cited by 2,761
The Effectiveness of Data Augmentation in Image Classification using Deep Learning
Perez, L., & Wang, J. (2017) · arXiv · doi:10.48550/arxiv.1712.04621 · Cited by 2,499
Body-mass index and mortality among 1.46 million white adults
Berrington de Gonzalez, A., Hartge, P., Cerhan, J. R., Flint, A. J., Hannan, L., MacInnis, R. J., Moore, S. C., Tobias, G. S., Anton-Culver, H., Freeman, L. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1000367 · Cited by 2,317
Ardila, D., Kiraly, A. P., Bharadwaj, S., Choi, B., Reicher, J. J., Peng, L., Tse, D., Etemadi, M., Ye, W., Corrado, G., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0447-x · Cited by 2,167
Prediction of cardiovascular risk factors from retinal fundus photographs via deep learning
Poplin, R., Varadarajan, A. V., Blumer, K., Liu, Y., McConnell, M. V., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0195-0 · Cited by 1,865
Havranek, E. P., Mujahid, M. S., Barr, D. A., Blair, I. V., Cohen, M. S., Cruz-Flores, S., Davey-Smith, G., Dennison-Himmelfarb, C. R., Lauer, M. S., Lockwood, D. W., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000228 · Cited by 1,472
SmoothGrad: removing noise by adding noise
Smilkov, D., Thorat, N., Kim, B., Viégas, F., & Wattenberg, M. (2017) · arXiv · doi:10.48550/arxiv.1706.03825 · Cited by 1,467
Robust Estimation of a Location Parameter
Huber, P. J. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_35 · Cited by 1,455 · cited 1×
“We investigated other variants of prediction loss (absolute loss, Huber loss 45 for regression and Focal loss 46 for classification), and they did not improve performance.”
Method(1992) · Cited by 1,405
Bhaskaran, K., dos-Santos-Silva, I., Leon, D. A., Douglas, I. J., & Smeeth, L. (2018) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(18)30288-2 · Cited by 1,228
Machine Learning and Prediction in Medicine — Beyond the Peak of Inflated Expectations
Chen, J. H., & Asch, S. M. (2017) · New England Journal of Medicine · doi:10.1056/nejmp1702071 · Cited by 1,171
Self-citationZhang, J., Gajjala, S., Agrawal, P., Tison, G. H., Hallock, L. A., Beussink-Nelson, L., Lassen, M. H., Fan, E., Aras, M. A., Jordan, C., et al. (2018) · Circulation · doi:10.1161/circulationaha.118.034338 · Cited by 1,006
Interpretation of Neural Networks Is Fragile
Ghorbani, A., Abid, A., & Zou, J. (2019) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v33i01.33013681 · Cited by 765
Self-citationFast and accurate view classification of echocardiograms using deep learning
Madani, A., Arnaout, R., Mofrad, M., & Arnaout, R. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0013-1 · Cited by 585
Ford, M. K., Beattie, W. S., & Wijeysundera, D. N. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-1-201001050-00007 · Cited by 549
ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography
(2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.12.008 · Cited by 515
Nagpal, K., Foote, D., Liu, Y., Chen, P.-H. C., Wulczyn, E., Tan, F., Olson, N., Smith, J. L., Mohtashamian, A., Wren, J. H., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0112-2 · Cited by 495
Label-free prediction of three-dimensional fluorescence images from transmitted-light microscopy
Ounkomol, C., Seshamani, S., Maleckar, M. M., Collman, F., & Johnson, G. R. (2018) · Nature Methods · doi:10.1038/s41592-018-0111-2 · Cited by 495
Age and Sex Estimation Using Artificial Intelligence From Standard 12-Lead ECGs
Attia, Z. I., Friedman, P. A., Noseworthy, P. A., Lopez-Jimenez, F., Ladewig, D. J., Satam, G., Pellikka, P. A., Munger, T. M., Asirvatham, S. J., Scott, C. G., et al. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007284 · Cited by 455
Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study
Kou, S., Caballero, L., Dulgheru, R., Voilliot, D., De Sousa, C., Kacharava, G., Athanassopoulos, G. D., Barone, D., Baroni, M., Cardim, N., et al. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet284 · Cited by 432 · cited 2×
“27,28 Age related changes in the heart, in particular changing chamber sizes and diastolic filling parameters, have been well characterized 29,30 , and our study builds upon this body of work to demonstrate that these signals are present to allow for prediction of these phenotypes to a degree of…”
BackgroundA Population-Based Study of Cardiovascular Mortality Following Early-Stage Breast Cancer
Abdel-Qadir, H., Austin, P. C., Lee, D. S., Amir, E., Tu, J. V., Thavendiranathan, P., Fung, K., & Anderson, G. M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3841 · Cited by 313
Madani, A., Ong, J. R., Tibrewal, A., & Mofrad, M. R. K. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0065-x · Cited by 250 · cited 1×
“5,6,24 Previous works have used convolutional neural networks (CNNs) trained on images and videos from echocardiography to perform segmentation to identify cardiac structures and derive cardiac function.”
MethodLeft Ventricular Ejection Fraction and Volumes: It Depends on the Imaging Method
Wood, P. W., Choy, J. B., Nanda, N. C., & Becher, H. (2014) · Echocardiography · doi:10.1111/echo.12331 · Cited by 244 · cited 2×
“18– 20 Formalized training guidelines for cardiologists recognize the value of experience in interpreting echocardiogram images and basic cardiology training might be insufficient to interpret echocardiograms at the highest level.”
BackgroundDeep-learning cardiac motion analysis for human survival prediction
Bello, G. A., Dawes, T. J. W., Duan, J., Biffi, C., de Marvao, A., Howard, L. S. G. E., Gibbs, J. S. R., Wilkins, M. R., Cook, S. A., Rueckert, D., et al. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0019-2 · Cited by 228
Xu, H., Cupples, L. A., Stokes, A., & Liu, C.-T. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.4587 · Cited by 182
Severe Mitral Annular Calcification
Eleid, M. F., Foley, T. A., Said, S. M., Pislaru, S. V., & Rihal, C. S. (2016) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.09.001 · Cited by 177
Munagala, V. K., Jacobsen, S. J., Mahoney, D. W., Rodeheffer, R. J., Bailey, K. R., & Redfield, M. M. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00516-9 · Cited by 174 · cited 1×
“27,28 Age related changes in the heart, in particular changing chamber sizes and diastolic filling parameters, have been well characterized 29,30 , and our study builds upon this body of work to demonstrate that these signals are present to allow for prediction of these phenotypes to a degree of…”
BackgroundU.S. Hospital Use of Echocardiography
Papolos, A., Narula, J., Bavishi, C., Chaudhry, F. A., & Sengupta, P. P. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.10.090 · Cited by 154
Cohen, M. G., Fonarow, G. C., Peterson, E. D., Moscucci, M., Dai, D., Hernandez, A. F., Bonow, R. O., & Smith, S. C. (2010) · Circulation · doi:10.1161/circulationaha.109.922286 · Cited by 149
Left Atrial Volume and Geometry in Healthy Aging: The Cardiovascular Health Study
Aurigemma, G. P., Gottdiener, J. S., Arnold, A. M., Chinali, M., Hill, J. C., & Kitzman, D. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.826602 · Cited by 119
Size Matters! Impact of Age, Sex, Height, and Weight on the Normal Heart Size
Pfaffenberger, S., Bartko, P. E., Graf, A. C., Pernicka, E., Babayev, J., Lolic, E., Bonderman, D., Baumgartner, H., Maurer, G., & Mascherbauer, J. (2013) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.113.000690 · Cited by 119
Gradio: Hassle-Free Sharing and Testing of ML Models in the Wild
Abid, A., Abdalla, A., Ali, A., Khan, D., Alfozan, A., & Zou, J. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1906.02569 · Cited by 115 · cited 1×
“26 For example, in the frames in Figure 2 with pacemaker lead, when we manually mask the lead in the frame, EchoNet changs its prediction to no pacemaker.”
MethodSelf-citationWiegers, S. E., Ryan, T., Arrighi, J. A., Brown, S. M., Canaday, B., Damp, J. B., Díaz‐Gómez, J. L., Figueredo, V. M., Garcia, M. J., Gillam, L. D., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.02.003 · Cited by 77
Certifiably Robust Interpretation in Deep LearningPreprint
Levine, A., Singla, S., & Feizi, S. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1905.12105 · Cited by 57
How to Explain Individual Classification Decisions
(2010) · Journal of Machine Learning Research · doi:10.5555/1756006.1859912 · Cited by 54
Variability in echocardiographic measurements of left ventricular function in septic shock patients
Geer, L. D., Oscarsson, A., & Engvall, J. E. (2015) · Cardiovascular Ultrasound · doi:10.1186/s12947-015-0015-6 · Cited by 53
Kälsch, H., Lehmann, N., Moebus, S., Hoffmann, B. H., Stang, A., Jöckel, K., Erbel, R. M., & Mahabadi, A. A. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.116.005093 · Cited by 53
Left Atrial Volume Index in Healthy Subjects: Clinical and Echocardiographic Correlates
D’Andrea, A., Riegler, L., Rucco, M. A., Cocchia, R., Scarafile, R., Salerno, G., Martone, F., Vriz, O., Caso, P., Calabrò, R., et al. (2013) · Echocardiography · doi:10.1111/echo.12217 · Cited by 48 · cited 2×
“Clinical review of images predicted to be of younger patients show preference for small atria and is consistent with prior studies showing age-related changes to the left atrium 30,36 .”
BackgroundResultMadu, E. C. (2000) · CHEST Journal · doi:10.1378/chest.117.3.657 · Cited by 38
Nagpal, K., Foote, D., Liu, Y., Chen, P.-H. C., Wulczyn, E., Tan, F., Olson, N., Smith, J. L., Mohtashamian, A., Wren, J. H., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0196-8 · Cited by 38
Wiegers, S. E., Ryan, T., Arrighi, J. A., Brown, S. M., Canaday, B., Damp, J. B., Díaz‐Gómez, J. L., Figueredo, V. M., Garcia, M. J., Gillam, L. D., et al. (2019) · Circulation Cardiovascular Imaging · doi:10.1161/hci.0000000000000026 · Cited by 30
Appropriate Use Criteria for Echocardiography
Almaraz, K., Yatskowitz, J. P., Huang, A., & Vold, A. (2019) · UNM’s Digital Repository (University of New Mexico) · Cited by 25
Abbott, J. A., & Gentile-Solomon, J. (2017) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.14846 · Cited by 18
(2010) · Europe PMC (PubMed Central) · Cited by 7
Gade, V. R., & Shaw, R. E. (2016) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(16)30503-4 · Cited by 1
Research works printed but not linked: 1
- Madani, A., Ong, J. R., Tiberwal, A. & Mofrad, M. R. US hospital use of echo- cardiography: Insights from the nationwide inpatient sample. J. Am. Coll. Cardiol. 67, 502-511 (2016).
Cited by
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212
Deep learning-enabled medical computer vision
Esteva, A., Chou, K., Yeung, S., Naik, N., Madani, A., Mottaghi, A., Liu, Y., Topol, E., Dean, J., & Socher, R. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00376-2 · Cited by 1,406
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153
Self-citationLoh, H. W., Ooi, C. P., Seoni, S., Barua, P. D., Molinari, F., & Acharya, U. R. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107161 · Cited by 734
Salahuddin, Z., Woodruff, H. C., Chatterjee, A., & Lambin, P. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105111 · Cited by 508
Metadata
- Authors
- Ghorbani, A., Ouyang, D., Abid, A., He, B., Chen, J. H., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y.
- Affiliations
- Stanford University (US)
- Stanford Medicine (US)
- Chan Zuckerberg Biohub San Francisco (US)
- Corresponding author
- Ouyang, David
- Zou, James Y.
- ORCID
- Venue
- npj Digital Medicine
- Published
- 2020-01-24
- Volume
- 3
- Issue
- 1
- Pages
- 10-10
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC6981156
- OpenAlex
- W3002705197
- Cited by
- 518
- References
- 67
- Citations by year
- 2026: 68 · 2025: 91 · 2024: 95 · 2023: 91 · 2022: 75 · 2021: 60 · 2020: 36
- FWCI
- 57.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nd)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- American College of Cardiology/ Merck Research Fellowship
- Topics
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Keywords
- echocardiography, convolutional neural networks, cardiac structure segmentation, left ventricular hypertrophy, left atrial enlargement, ejection fraction estimation, cardiovascular risk prediction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.