The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Comparing scientific abstracts generated by ChatGPT to real abstracts with detectors and blinded human reviewers

Open access

Published version of a preprint

Abstract

Large language models such as ChatGPT can produce increasingly realistic text, with unknown information on the accuracy and integrity of using these models in scientific writing. We gathered fifth research abstracts from five high-impact factor medical journals and asked ChatGPT to generate research abstracts based on their titles and journals. Most generated abstracts were detected using an AI output detector, ‘GPT-2 Output Detector’, with % ‘fake’ scores (higher meaning more likely to be generated) of median [interquartile range] of 99.98% ‘fake’ [12.73%, 99.98%] compared with median 0.02% [IQR 0.02%, 0.09%] for the original abstracts. The AUROC of the AI output detector was 0.94. Generated abstracts scored lower than original abstracts when run through a plagiarism detector website and iThenticate (higher scores meaning more matching text found). When given a mixture of original and general abstracts, blinded human reviewers correctly identified 68% of generated abstracts as being generated by ChatGPT, but incorrectly identified 14% of original abstracts as being generated. Reviewers indicated that it was surprisingly difficult to differentiate between the two, though abstracts they suspected were generated were vaguer and more formulaic. ChatGPT writes believable scientific abstracts, though with completely generated data. Depending on publisher-specific guidelines, AI output detectors may serve as an editorial tool to help maintain scientific standards. The boundaries of ethical and acceptable use of large language models to help scientific writing are still being discussed, and different journals and conferences are adopting varying policies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-023-00819-6

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Generated abstracts have a similar patient cohort size as original abstracts. Cohort sizes from original abstracts (x-axis) and generated abstracts (y-axis) plotted on a logarithmic 10 scale.
Fig. 1 Generated abstracts have a similar patient cohort size as original abstracts. Cohort sizes from original abstracts (x-axis) and generated abstracts (y-axis) plotted on a logarithmic 10 scale.CC BY · PubMed Central
Fig. 2 Many generated abstracts can be detected using an AI output detector. a AI detection scores as [% ‘fake’] per GPT-2 Output Detector for original abstracts and generated abstracts. Higher score indicates more likely to be generated by AI. b The AI output detector ROC curve for discriminating between original and generated abstracts, with AUROC of 0.94.
Fig. 2 Many generated abstracts can be detected using an AI output detector. a AI detection scores as [% ‘fake’] per GPT-2 Output Detector for original abstracts and generated abstracts. Higher score indicates more likely to be generated by AI. b The AI output detector ROC curve for discriminating between original and generated abstracts, with AUROC of 0.94.CC BY · PubMed Central
Fig. 3 Generated abstracts score lower than original abstracts on plagiarism detectors. a Plagiarism scores from plagiarism detector website, with higher % ‘plagiarized’ score indicating more matching text was found. b iThenticate Similarity Index for original abstracts and generated abstracts [%], with higher value meaning more similar text was found.
Fig. 3 Generated abstracts score lower than original abstracts on plagiarism detectors. a Plagiarism scores from plagiarism detector website, with higher % ‘plagiarized’ score indicating more matching text was found. b iThenticate Similarity Index for original abstracts and generated abstracts [%], with higher value meaning more similar text was found.CC BY · PubMed Central
Fig. 4 Reviewers use criteria different than the AI output detector for flagging abstracts as either generated or original. The AI detection scores for generated abstracts were not significantly different (p = 0.45) between abstracts that human reviewers identified as generated, and those that they failed to identify as generated.
Fig. 4 Reviewers use criteria different than the AI output detector for flagging abstracts as either generated or original. The AI detection scores for generated abstracts were not significantly different (p = 0.45) between abstracts that human reviewers identified as generated, and those that they failed to identify as generated.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

3 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 1,099

Metadata

Authors
Gao, C. A., Howard, F. M., Markov, N. S., Dyer, E. C., Ramesh, S., Luo, Y., & Pearson, A. T.
Affiliations
  • Northwestern University (US)
  • University of Chicago (US)
Corresponding author
Gao, Catherine A.
Venue
npj Digital Medicine
Published
2023-04-26
Volume
6
Issue
1
Pages
75-75
ISSN
2398-6352 (ISSN-L)
OpenAlex
W4367051110
Cited by
1,099
References
26
Citations by year
2026: 189 · 2025: 235 · 2024: 342 · 2023: 326
FWCI
273.24
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Knowledge@UChicago (University of Chicago) (submittedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • University of Chicago (cc-by)
Funders
  • U.S. Department of Health and Human Services (U01-CA243075, R01LM013337, R56-DE030958, U01TR003528)
  • Burroughs Wellcome Fund
  • Conquer Cancer Foundation (2022YIA-6675470300)
  • Breast Cancer Research Foundation (2022YIA-6675470300)
  • Cancer Research Foundation
  • Fanconi Anemia Research Fund
  • American Society of Clinical Oncology (2022YIA-6675470300)
  • Horizon Therapeutics
  • National Institutes of Health (U01TR003528)
  • Stand Up To Cancer
  • National Heart, Lung, and Blood Institute (F32HL162377)
  • National Cancer Institute (K12CA139160, U01CA243075)
  • National Institute of Dental and Craniofacial Research (R56DE030958)
  • U.S. National Library of Medicine (R01LM013337)
  • National Center for Advancing Translational Sciences
Topics
  • Social Sciences › Education › Academic integrity and plagiarism
  • Social Sciences › Library and Information Sciences › Academic Writing and Publishing
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
ChatGPT, large language models, AI-generated text detection, scientific abstracts, plagiarism detection, medical journal abstracts, scientific integrity, AI in scientific writing, editorial guidelines

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparing scientific abstracts generated by ChatGPT to real abstracts with detectors and blinded human reviewers. https://app.cochat.ai/papers/10.1038/s41746-023-00819-6
The paper
Gao, C. A., Howard, F. M., Markov, N. S., Dyer, E. C., Ramesh, S., Luo, Y., & Pearson, A. T. (2023). Comparing scientific abstracts generated by ChatGPT to real abstracts with detectors and blinded human reviewers. npj Digital Medicine. https://doi.org/10.1038/s41746-023-00819-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.