CoChat

Evaluation of Reference Tissue Models for the Analysis of [ 11 C]( R )-PK11195 Studies

Kropholler, Marc A, Boellaard, Ronald, Schuitemaker, Alie, Folkersma, Hedy, van Berckel, Bart NM, Lammertsma, Adriaan A · 2006 · Journal of Cerebral Blood Flow & Metabolism
Cited by 94

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

[ 11 C]( R )-PK11195 is a marker of activated microglia, which can be used to measure inflammation in neurologic disorders. The purpose of the present study was to define the optimal reference tissue model based on a comparison with a validated plasma input model and using clinical studies and Monte Carlo simulations. Accuracy and reproducibility of reference tissue models were evaluated using Monte Carlo simulations. The effects of noise and variation in specific binding, nonspecific binding and blood volume were evaluated. Dynamic positron emission tomography scans were performed on 13 subjects, and radioactivity in arterial blood was monitored online. In addition, blood samples were taken to generate a metabolite corrected plasma input function. Both a (validated) two-tissue reversible compartment model with K 1 /k 2 fixed to whole cortex and various reference tissue models were fitted to the data. Finally, a simplified reference tissue model (SRTM) corrected for nonspecific binding using plasma input data (SRTM pl_corr ) was investigated. Correlations between reference tissue models (including SRTM pl_corr ) and the plasma input model were calculated. Monte Carlo simulations indicated that low-specific binding results in decreased accuracy and reproducibility. In this respect, the SRTM and SRTM pl_corr performed relatively well. Varying blood volume had no effect on performance. In the clinical evaluation, SRTM pl_corr and SRTM had the highest correlations with the plasma input model ( R 2 = 0.82 and 0.78, respectively). SRTM pl_corr is optimal when an arterial plasma input curve is available. Simplified reference tissue model is the best alternative when no plasma input is available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/sj.jcbfm.9600289

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 94

Metadata

Authors
Kropholler, M. A., Boellaard, R., Schuitemaker, A., Folkersma, H., van Berckel, B. N., & Lammertsma, A. A.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2006-11
Volume
26
Issue
11
Pages
1431-1441
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1979473451
Cited by
94
References
8
FWCI
6.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Reference Tissue Models for the Analysis of [ 11 C]( R )-PK11195 Studies. https://app.cochat.ai/papers/10.1038/sj.jcbfm.9600289
The paper
Kropholler, M. A., Boellaard, R., Schuitemaker, A., Folkersma, H., van Berckel, B. N., & Lammertsma, A. A. (2006). Evaluation of Reference Tissue Models for the Analysis of [ 11 C]( R )-PK11195 Studies. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/sj.jcbfm.9600289

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.