Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A year-long investigation of air change rates in an occupied house was undertaken to establish the effects of temperature, wind velocity, use of exhaust fans, and window-opening behavior. Air change rates were calculated by periodically injecting a tracer gas (SF(6)) into the return air duct and measuring the concentration in 10 indoor locations sequentially every minute by a gas chromatograph equipped with an electron capture detector. Temperatures were also measured outdoors and in the 10 indoor locations. Relative humidity (RH) was measured outdoors and in five indoor locations every 5 min. Wind speed and direction in the horizontal plane were measured using a portable meteorological station mounted on the rooftop. Use of the thermostat-controlled attic fan was recorded automatically. Indoor temperatures increased from 21 degrees C in winter to 27 degrees C in summer. Indoor RH increased from 20% to 70% in the same time period. Windows were open only a few percent of the time in winter but more than half the time in summer. About 4600 hour-long average air change rates were calculated from the measured tracer gas decay rates. The mean (SD) rate was 0.65 (0.56) h(-1). Tracer gas decay rates in different rooms were very similar, ranging only from 0.62 to 0.67 h(-1), suggesting that conditions were well mixed throughout the year. The strongest influence on air change rates was opening windows, which could increase the rate to as much as 2 h(-1) for extended periods, and up to…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“which are irritants to the eyes, mucous membranes and upper respiratory tract [60, 80, 81].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [80]
Citations
Cites
Building ventilation: theory and measurement
(1997) · Choice Reviews Online · doi:10.5860/choice.35-2135 · Cited by 734 · cited 1×
“Instead, the observed slope will have a positive bias with respect to the air change rate, the magnitude of the bias being dependent on the amount of Journal of Exposure Analysis and Environmental Epidemiology (2002) 12(4) 301 interzonal flow (Etheridge and Sandberg, 1996).”
BackgroundMurray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 2×
“Air change rates have been measured in several thousand homes in the US (Murray and Burmaster, 1995), but most of these were one- time measurements made over short periods of 12 h to several weeks, making it impossible to determine the effects on air change rates of weather conditions and homeowner behavior such as wi…”
BackgroundThe Effect of Opening Windows on Air Change Rates in Two Homes
Howard-Reed, C., Wallace, L. A., & Ott, W. R. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470775 · Cited by 218 · cited 5×
“One recent study has provided quantitative information on the effect in two homes of opening windows to measured widths (Howard-Reed et al., 2002), but may have lacked sufficient measurements to derive a robust relationship with temperature and wind.”
BackgroundResultInfluentialSelf-citationRadon transport into a detached one-story house with a basement
Nazaroff, W. W., Feustel, H. E., Nero, A. V., Revzan, K. L., Grimsrud, D. T., Essling, M. A., & Toohey, R. E. (1985) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(85)90134-9 · Cited by 111 · cited 2×
“A positive intercept of similar magnitude (0.13–0.16 h 1) for a multiple regression including wind speed and either pressure or temperature difference was also noted in the study of Nazaroff et al. (1985) (our calculations based on their Table 2) .”
BackgroundResultInfluentialVentilation Research in Occupied Houses.
Dick, J. B., & Thomas, D. (1951) · Cited by 56
Measured Air Leakage of Buildings
Trechsel, H., & Lagus, P. L. (1986) · doi:10.1520/stp904-eb · Cited by 38 · cited 1×
“Two ASTM publications (Hunt et al., 1980; Trechsel and Lagus, 1986) provide convenient collections of papers on air leakage measurements.”
BackgroundThe Fundamentals of Natural Ventilation of Houses.
Dick, J. B. (1950) · Cited by 30
Field studies of dependence of air infiltration on outside temperature and wind
Malik, N. (1978) · Energy and Buildings · doi:10.1016/0378-7788(78)90008-7 · Cited by 27 · cited 2×
“Many find no effect of wind direction, but others (Malik, 1978) find that direction is important.”
BackgroundField measurements of air infiltration in ten elec-trically-heated houses.
Coblentz, C. W., & Achenbach, P. (1963) · Cited by 26
Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building
Emmerich, S. J., & Nabinger, S. J. (2000) · doi:10.6028/nist.ir.6461 · Cited by 24
Self-citation
Research works printed but not linked: 3
- Bahnfleth DR Moseley TT Harris WS Measurement of infiltration in two residences: Part I. Technique and measured infiltration, ASHRAE Trans (1957) 63: 453–476
- Lagus PL Air leakage measurements by the tracer dilution method In: Hunt C.M., King J.C., and Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980 pp 16–49
- Laschober RR Healy JH Statistical analyses of air leakage in split-level residences, ASHRAE Trans (1964) 70: 364–374
Cited by
Identifying airborne transmission as the dominant route for the spread of COVID-19
Zhang, R., Li, Y., Zhang, A. L., Wang, Y., & Molina, M. J. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2009637117 · Cited by 1,236
Fabi, V., Andersen, R. V., Corgnati, S., & Olesen, B. W. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.07.009 · Cited by 659
“[74] measured air change rates in a house in Virginia during a year, they found that the window opening behaviour had the largest effect on air change rates, causing increases ranging from a few tenths of an air change per hour to approximately two air changes per hour.”
BackgroundNguyen, J. L., Schwartz, J., & Dockery, D. W. (2014) · Indoor Air · doi:10.1111/ina.12052 · Cited by 410
“N IH -PA Author M anuscript N IH -PA Author M anuscript N IH -PA Author M anuscript example, windows are more likely to be opened for extended periods of time when the outside temperature is moderate (Wallace et al., 2002).”
BackgroundMethodInfluentialLaidlaw, M. A. S., & Filippelli, G. M. (2008) · Applied Geochemistry · doi:10.1016/j.apgeochem.2008.05.009 · Cited by 325
Window opening behaviour modelled from measurements in Danish dwellings
Andersen, R., Fabi, V., Toftum, J., Corgnati, S. P., & Olesen, B. W. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.07.005 · Cited by 300
Source Strengths of Ultrafine and Fine Particles Due to Cooking with a Gas Stove
Wallace, L. A., Emmerich, S. J., & Howard-Reed, C. (2004) · Environmental Science & Technology · doi:10.1021/es0306260 · Cited by 290
Self-citationStazi, F., Naspi, F., & D'Orazio, M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.03.021 · Cited by 223
The Effect of Opening Windows on Air Change Rates in Two Homes
Howard-Reed, C., Wallace, L. A., & Ott, W. R. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470775 · Cited by 218
Self-citationVentilation rates in the bedrooms of 500 Danish children
Bekö, G., Lund, T., Nors, F., Toftum, J., & Clausen, G. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.04.014 · Cited by 209
Wallace, L. (2006) · Aerosol Science and Technology · doi:10.1080/02786820600612250 · Cited by 187
Self-citationWichmann, J., Lind, T., Nilsson, M. A.-M., & Bellander, T. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.08.023 · Cited by 182
Meng, Q. Y., Spector, D., Colome, S., & Turpin, B. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.07.066 · Cited by 180
Indoor air quality and comfort in seven newly built, energy-efficient houses in France
Derbez, M., Berthineau, B., Cochet, V., Lethrosne, M., Pignon, C., Riberon, J., & Kirchner, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.10.017 · Cited by 168
“The seasonal variation in CO2 levels (lower in summer than in winter) is most likely related to the increased rate of air exchange in these houses in summer due to the opening of windows, as observed in another studies [38,39].”
ResultField measurement of ventilation rates
Persily, A. K. (2016) · Indoor Air · doi:10.1111/ina.12193 · Cited by 164
Residential air‐change rates: A critical review
Nazaroff, W. W. (2021) · Indoor Air · doi:10.1111/ina.12785 · Cited by 161
Allen, R. W., Adar, S. D., Avol, E., Cohen, M., Curl, C. L., Larson, T., Liu, L.-J. S., Sheppard, L., & Kaufman, J. D. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104447 · Cited by 161
Seasonal cycle of indoor-VOCs: comparison of apartments and cities
Schlink, U., Rehwagen, M., Damm, M., Richter, M., Borte, M., & Herbarth, O. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.11.003 · Cited by 155
Fabi, V., Andersen, R. V., Corgnati, S. P., & Olesen, B. W. (2013) · Building Simulation · doi:10.1007/s12273-013-0119-6 · Cited by 151
“However in the last years dedicated literature studies (Brundrett 1977; Kvistgaard and Collet 1990; Weihl and Gladhart 1990; Wallace et al. 2002; Keiding 2003; Price and Sherman 2006; Offerman et al. 2008; Xu et al. 2009; Andersen et al. 2009) have increased and different questionnaire surveys, monitoring and statisti…”
BackgroundHoward-Reed, C. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.012 · Cited by 157
“The determination of decay rates for indoor particle sources is part of a larger monitoring study that has been described elsewhere (Wallace et al., 2002; Wallace and Howard-Reed, 2002).”
BackgroundSelf-citationMelymuk, L. E., Robson, M., Helm, P. A., & Diamond, M. L. (2012) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2012.04.022 · Cited by 164
Migration of volatile organic compounds from attached garages to residences: A major exposure source
Batterman, S., Jia, C., & Hatzivasilis, G. (2007) · Environmental Research · doi:10.1016/j.envres.2007.01.008 · Cited by 149
“Earlier studies have shown larger effects of window openings (Wallace et al., 2002), lower AERs for houses built in the 1970s, and negative correlation between AER and house volume (Oie et al.”
BackgroundWallace, L., & Williams, R. (2005) · Environmental Science & Technology · doi:10.1021/es049547u · Cited by 141
Self-citationLu, C., Deng, Q., Li, Y., Sundell, J., & Norbäck, D. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.033 · Cited by 156
Zhang, J., An, J., Qu, Y., Liu, X., & Chen, Y. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.08.030 · Cited by 136
Jia, C., Batterman, S., & Godwin, C. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.11.047 · Cited by 147
Chen, C., Zhao, B., & Weschler, C. J. (2012) · Epidemiology · doi:10.1097/ede.0b013e31826b800e · Cited by 136
Wallace, L. A. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.10.003 · Cited by 127
“The town house has been described fully in previous publications (Wallace et al., 2002; Wallace and Howard-Reed, 2002).”
BackgroundSelf-citationXu, X., Yu, H., Sun, Q., & Tam, V. W. Y. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113396 · Cited by 151
Effects of types of ventilation system on indoor particle concentrations in residential buildings
Park, J. S., Jee, N. Y., & Jeong, J.-W. (2014) · Indoor Air · doi:10.1111/ina.12117 · Cited by 123
Remion, G., Moujalled, B., & Mankibi, M. E. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106180 · Cited by 133
Xu, Y., Hubal, E. A. C., & Little, J. C. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.0900559 · Cited by 125
“…intake rate of dust (DIR, mg/kg/day) 1.03 10.3 Wensing et al. 2005 Body weight (kg) 9.15 62.2 U.S. EPA 1997 Air exchange rate for three compartments (1/hr) 0.1 1.1 Wallace et al. 2002 VF area in kitchen (A1vinyl, m2) 11.9 47.6 Hodgson et al. 2005 VF area in bathroom (A2vinyl, m2) 5.1 20.4 Hodgson…”
BackgroundInfluentialOccupants’ interactions with windows in 8 residential apartments in Beijing and Nanjing, China
Shi, S., & Zhao, B. (2015) · Building Simulation · doi:10.1007/s12273-015-0266-z · Cited by 122
The effectiveness of indoor photocatalytic paints on NO and HONO levels
Gandolfo, A., Bartolomei, V., Alvarez, E. G., Tlili, S., Gligorovski, S., Kleffmann, J., & Wortham, H. (2014) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.11.011 · Cited by 113
Ogulei, D., Hopke, P. K., & Wallace, L. A. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00418.x · Cited by 115
Self-citationFabi, V., Andersen, R. K., & Corgnati, S. P. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.08.016 · Cited by 110
Factors influencing variability in the infiltration of PM2.5 mass and its components
MacNeill, M., Wallace, L. A., Kearney, J. P., Allen, R. W., Ryswyk, K. V., Judek, S., Xu, X., & Wheeler, A. J. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.07.005 · Cited by 115
Self-citationTian, Z., & Love, J. A. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.10.002 · Cited by 109
Indoor inhalation intake fractions of fine particulate matter: review of influencing factors
Hodas, N., Loh, M., Shin, H. ‐., Li, D., Bennett, D., McKone, T. E., Jolliet, O., Weschler, C. J., Jantunen, M., Lioy, P., et al. (2016) · Indoor Air · doi:10.1111/ina.12268 · Cited by 100
“…al., 2012; G oze nski et al., 2014; Iwashita and Akasaka, 1997; Johnson and Long, 2005; Levie et al., 2014; Marr et al., 2012; Persily, 2015; Stephens, 2015; Wallace et al., 2002; US EPA, 2011) provide needed information for accounting for temporal and spatial variability in ventilation conditions.”
Influence of environmental temperature on risk of gestational diabetes
Booth, G. L., Luo, J., Park, A. L., Feig, D. S., Moineddin, R., & Ray, J. G. (2017) · Canadian Medical Association Journal · doi:10.1503/cmaj.160839 · Cited by 110
Pacitto, A., Amato, F., Moreno, T., Pandolfi, M., Fonseca, A. S., Mazaheri, M., Stabile, L., Buonanno, G., & Querol, X. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135673 · Cited by 107
Stabile, L., Buonanno, G., Frattolillo, A., & Dell’Isola, M. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.001 · Cited by 99
Modeling ventilation rates in bedrooms based on building characteristics and occupant behavior
Bekö, G., Toftum, J., & Clausen, G. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.05.002 · Cited by 92
The effect of ventilation on indoor exposure to semivolatile organic compounds
Liu, C., Zhang, Y., Benning, J. L., & Little, J. C. (2014) · Indoor Air · doi:10.1111/ina.12139 · Cited by 92
Air change rates at night in northeast Chinese homes
Hou, J., Zhang, Y., Sun, Y., Wang, P., Zhang, Q., Kong, X., & Sundell, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.030 · Cited by 92
Brown, K. W., Sarnat, J. A., Suh, H. H., Coull, B. A., & Koutrakis, P. (2009) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2009.02.016 · Cited by 92
Effects of PM, TVOCs and comfort parameters on indoor air quality of residences with young children
Stamatelopoulou, A., Asimakopoulos, D. N., & Maggos, T. (2019) · Building and Environment · doi:10.1016/j.buildenv.2018.12.065 · Cited by 82
Orch, Z. E., Stephens, B., & Waring, M. S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.01.006 · Cited by 94
“(2002) [42] and Marr et al.”
MethodShi, S., Chen, C., & Zhao, B. (2016) · Environmental Pollution · doi:10.1016/j.envpol.2016.09.069 · Cited by 80
Bekö, G., Gustavsen, S., Frederiksen, M., Bergsøe, N. C., Kolarik, B. D., Gunnarsen, L., Toftum, J., & Clausen, G. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.016 · Cited by 80
Concentrations and emissions of gasoline and other vapors from residential vehicle garages
Batterman, S., Hatzivasilis, G., & Jia, C. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.11.017 · Cited by 76
Nguyen, A. T., & Reiter, S. (2013) · Journal of Building Performance Simulation · doi:10.1080/19401493.2013.770067 · Cited by 78
“25 (Wallace et al. 2002)”
Residential cooking and use of kitchen ventilation: The impact on exposure
Sun, L., & Wallace, L. A. (2020) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2020.1823525 · Cited by 79
“An early study by Wallace, Emmerich, and Howard-Reed (2002) investigated the effect of temperature, wind, attic fan, and windows on air change rates in an occupied house.”
BackgroundSelf-citationLight-induced nitrous acid (HONO) production from NO2 heterogeneous reactions on household chemicals
Alvarez, E. G., Sörgel, M., Gligorovski, S., Bassil, S., Bartolomei, V., Coulomb, B., Zetzsch, C., & Wortham, H. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.034 · Cited by 76
A review of air exchange rate models for air pollution exposure assessments
Breen, M. S., Schultz, B. D., Sohn, M. D., Long, T., Langstaff, J., Williams, R., Isaacs, K., Meng, Q. Y., Stallings, C., & Smith, L. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.30 · Cited by 69
“One study found no effect from wind speed.(38) Other studies showed a linear or quadratic relationship between the AER and wind speed(33-37,39) and wind direction.”
BackgroundLiang, W., & Yang, X. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.009 · Cited by 69
Okonski, K., Degrendele, C., Melymuk, L. E., Landlová, L., Kukučka, P., Vojta, Š., Kohoutek, J., Čupr, P., & Klánová, J. (2014) · Environmental Science & Technology · doi:10.1021/es5044547 · Cited by 71
Gandolfo, A., Rouyer-Denimal, L., Wortham, H., & Gligorovski, S. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.03.021 · Cited by 67
Indoor particulate matter in rural, wood stove heated homes
Semmens, E. O., Noonan, C. W., Allen, R. W., Weiler, E. C., & Ward, T. J. (2015) · Environmental Research · doi:10.1016/j.envres.2015.02.005 · Cited by 78
Synergies and trade-offs between energy efficiency and resiliency to extreme heat – A case study
Baniassadi, A., & Sailor, D. J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.037 · Cited by 66
A 3-year follow-up of indoor air quality and comfort in two energy-efficient houses
Derbez, M., Berthineau, B., Cochet, V., Pignon, C., Ribéron, J., Wyart, G., Mandin, C., & Kirchner, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.028 · Cited by 76
“[32] Wallace L, Emmerich SJ, Howard-Reed C.”
BackgroundDetailed investigation of ventilation rates and airflow patterns in a northern California residence
Liu, Y. J., Misztal, P. K., Xiong, J., Tian, Y., Arata, C. M., Nazaroff, W. W., & Goldstein, A. H. (2018) · Indoor Air · doi:10.1111/ina.12462 · Cited by 69
“13 h per 10 °C, comparable to values reported for other houses.(9,29,31,32) The relationship is more variable at higher wind speeds, suggesting that wind also influences air change rate, although to a smaller extent than temperature difference at this house.”
BackgroundResultBartolomei, V., Alvarez, E. G., Wittmer, J., Tlili, S., Strekowski, R., Temime‐Roussel, B., Quivet, É., Wortham, H., Zetzsch, C., Kleffmann, J., et al. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01905 · Cited by 65
Johnson, T., Myers, J. D., Kelly, T. J., Wisbith, A. S., & Ollison, W. M. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500294 · Cited by 63
Bartolomei, V., Sörgel, M., Gligorovski, S., Alvarez, E. G., Gandolfo, A., Strekowski, R., Quivet, É., Held, A., Zetzsch, C., & Wortham, H. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2836-5 · Cited by 63
“Assuming an average air exchange rate of 0.56 h−1 (Wallace et al. 2002), we can estimate the concentration of HONO produced by the paint in function of time by the procedure explained below.”
MethodInfluentialFlame retardants in urban air: A case study in Toronto targeting distinct source sectors
Saini, A., Clarke, J., Jariyasopit, N., Rauert, C., Schuster, J. K., Halappanavar, S. S., Evans, G. J., Su, Y., & Harner, T. (2019) · Environmental Pollution · doi:10.1016/j.envpol.2019.01.027 · Cited by 63
Liu, J., Deng, H., Lakey, P. S. J., Jiang, H., Mekić, M., Wang, X., Shiraiwa, M., & Gligorovski, S. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c05624 · Cited by 62
Du, L., Batterman, S., Godwin, C., Chin, J.-Y., Parker, E., Breen, M., Brakefield, W., Robins, T., & Lewis, T. (2012) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph9124639 · Cited by 60
“In summer and in warm climates, air conditioner use can lower ACRs, as seen in Houston, while in moderate climates or when temperatures are mild, natural (and sometimes mechanical) ventilation promoted by opened windows and doors increases ACRs [9,35,41].”
BackgroundInfluentialFactors controlling volatile organic compounds in dwellings in Melbourne, Australia
Cheng, M., Galbally, I. E., Molloy, S. B., Selleck, P. W., Keywood, M., Lawson, S. J., Powell, J. C., Gillett, R., & Dunne, E. (2015) · Indoor Air · doi:10.1111/ina.12201 · Cited by 64
Lin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
“In hotels and many other buildings, ACRs depend on the design and operation of the mechanical systems, infiltration rates (which depend on indoor-outdoor temperature differences and wind speed 80 ), building design, and other factors.”
Johnson, T., & Long, T. F. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500409 · Cited by 59
“A number of studies (Wallace and Ott, 1996; Johnson et al., 1998, 2004; Wallace et al., 2002; Howard-Reed et al., 2002) have shown that AER in residences is significantly affected by the number and location of open windows and doors.”
BackgroundThe transport of gaseous pollutants due to stack and wind effect in high-rise residential buildings
Mao, J., Yang, W., & Gao, N. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.10.012 · Cited by 62
Kumar, P., Hama, S. M. L., Abbass, R. A., Nogueira, T., Brand, V. S., Wu, H.-W., Abulude, F. O., Adelodun, A. A., Andrade, M. D. F., Asfaw, A., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105254 · Cited by 66
Hong, G., & Kim, B. S. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.11.027 · Cited by 58
A framework to estimate heat energy loss in building operation
Najjar, M. K., Figueiredo, K. V., Hammad, A. W. A., Tam, V. W. Y., Evangelista, A. C. J., & HADDAD, A. N. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.07.026 · Cited by 64
Sánchez-Soberón, F., Mari, M., Kumar, V., Rovira, J., Nadal, M., & Schuhmacher, M. (2015) · Environmental Research · doi:10.1016/j.envres.2015.09.008 · Cited by 61
Estimation of residential fine particulate matter infiltration in Shanghai, China
Zhou, X., Cai, J., Zhao, Y., Chen, R., Wang, C., Zhao, A., Yang, C., Li, H., Liu, S., Cao, J., et al. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.10.054 · Cited by 58
The Effect of Ventilation Strategies on Indoor Air Quality and Energy Consumptions in Classrooms
Stabile, L., Massimo, A., Canale, L., Russi, A., Andrade, A., & Dell’Isola, M. (2019) · Buildings · doi:10.3390/buildings9050110 · Cited by 59
“Such ndecay_close values are similar to the air exchange rate data measured with windows closed in Italian classrooms [29] as well as similar ndecay_open were measured by Wallace, Emmerich and Howard-Reed [57] in their tests performed with windows open.”
Exploring Variation and Predictors of Residential Fine Particulate Matter Infiltration
Clark, N., Allen, R. W., Hystad, P., Wallace, L. A., Dell, S., Foty, R. G., Dąbek-Złotorzyńska, E., Evans, G. J., & Wheeler, A. J. (2010) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph7083211 · Cited by 62
“Open windows significantly increase air exchange rates (by an estimated 1.1 air changes per hour as measured by Wallace et al. 2002 [42]) and thereby also increased Finf [11,42,48].”
BackgroundInfluentialSelf-citationLiu, J., Li, S., Zeng, J., Mekić, M., Yu, Z., Zhou, W., Loisel, G., Gandolfo, A., Song, W., Wang, X., et al. (2019) · Environmental Science Processes & Impacts · doi:10.1039/c9em00194h · Cited by 58
Long-term concentrations of volatile organic compounds in a new apartment in Beijing, China
Liang, W., Yang, C., & Yang, X. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.10.016 · Cited by 60
Breen, M. S., Breen, M., Williams, R. W., & Schultz, B. D. (2010) · Environmental Science & Technology · doi:10.1021/es101800k · Cited by 53
Air exchange rates and migration of VOCs in basements and residences
Du, L., Batterman, S., Godwin, C., Rowe, Z. E., & Chin, J.-Y. (2015) · Indoor Air · doi:10.1111/ina.12178 · Cited by 61
“Emission rates from these sources and the resulting concentrations will depend on the source itself, as well as temperature, season, local ventilation, sampling location, averaging time, and meteorology (Johnson et al., 2004; Wallace et al., 2002).”
BackgroundInfluentialField testing of natural ventilation in college student dormitories (Beijing, China)
Li, H., Xiao-feng, L., & Qi, M. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.04.009 · Cited by 51
Ali, A. S., Coté, C., Heidarinejad, M., & Stephens, B. (2019) · Sensors · doi:10.3390/s19184017 · Cited by 50
“The trend in ACRs over this time period indicates their correlation with varying indoor-outdoor temperature differences as the weather changes from winter to spring, which is consistent with indoor/outdoor temperature differences and varying wind conditions as key driving forces of air infiltration in buildings [55].”
BackgroundHow window ventilation behaviour affects the heat resilience in multi-residential buildings
Schünemann, C., Schiela, D., & Ortlepp, R. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107987 · Cited by 50
The Relationship Between Indoor and Outdoor Temperature in Two Types Of Residence
Lee, K., & Lee, D. (2015) · Energy Procedia · doi:10.1016/j.egypro.2015.11.647 · Cited by 51
“When indoor temperature and RH were measured for 1 year in a house in the United States, indoor temperature ranged from 21 to 27°C and RH ranged from 25 to 63% [13].”
BackgroundRelations between indoor and outdoor PM2.5 and constituent concentrations
Liu, C., & Zhang, Y. (2018) · Frontiers of Environmental Science & Engineering · doi:10.1007/s11783-019-1089-4 · Cited by 56
Sukiene, V., Gerecke, A. C., Park, Y.-M., Zennegg, M., Bakker, M. I., Delmaar, C. J. E., Hungerbühler, K., & von Goetz, N. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.5b05906 · Cited by 48
Shi, S., Li, H., Ding, X., & Gao, X. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106610 · Cited by 56
Validation of multizone IAQ model predictions for tracer gas in a townhouse
Emmerich, S. J., Howard-Reed, C., & Nabinger, S. J. (2004) · Building Services Engineering Research and Technology · doi:10.1191/0143624404bt100oa · Cited by 45
Self-citationFine and Ultrafine Particle Decay Rates in Multiple Homes
Wallace, L. A., Kindzierski, W. B., Kearney, J. P., MacNeill, M., Héroux, M.-È., & Wheeler, A. J. (2013) · Environmental Science & Technology · doi:10.1021/es402580t · Cited by 48
Self-citationParticles Removal by Negative ionic Air Purifier in Cleanroom
Shiue, A., Hu, S.-C., & Tu, M.-L. (2011) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2010.06.0048 · Cited by 43
Mora, D., Carpino, C., & Simone, M. D. (2017) · Energy Efficiency · doi:10.1007/s12053-017-9553-0 · Cited by 43
A novel approach for selecting typical hot-year (THY) weather data
Guo, S., Yan, D., Hong, T., Xiao, C., & Cui, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.03.065 · Cited by 46
“When the windows are open, the max ventilation rate was set to five air changes per hour (ACH) according to the existing measurements (Wallace et al., 2002).”
MethodApplication of a mineral binder to reduce VOC emissions from indoor photocatalytic paints
Morin, J., Gandolfo, A., Temime‐Roussel, B., Strekowski, R., Brochard, G., Bergé, V., Gligorovski, S., & Wortham, H. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.04.031 · Cited by 43
Understanding transmission and intervention for the COVID-19 pandemic in the United States
Li, Y., Zhang, R., Zhao, J., & Molina, M. J. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141560 · Cited by 45
“While the atmospheric conditions are significantly different during the period of March 1 to May 18 and among the fifteen states, indoor conditions are typically less variable (Wallace et al., 2002).”
Ethnicity, housing and personal factors as determinants of VOC exposures
D’Souza, J. C., Jia, C., Mukherjee, B., & Batterman, S. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.03.017 · Cited by 45
The Role of HVAC Design and Windows on the Indoor Airflow Pattern and ACH
Pirouz, B., Palermo, S. A., Naghib, S. N., Mazzeo, D., Turco, M., & Piro, P. (2021) · Sustainability · doi:10.3390/su13147931 · Cited by 42
“The impact of wind speed and direction on ACH was very little [12].”
BackgroundWu, Y., Lu, Y., & Chou, D.-C. (2018) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/cty007 · Cited by 39
“[41], the estimated infiltration rate of the library rooms in winter would be about two to three times that in transition season.”
BackgroundHossain, M. S., Che, W., Frey, H. C., & Lau, A. K. H. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108351 · Cited by 35
Metadata
- Authors
- WALLACE, L. A., EMMERICH, S. J., & HOWARD-REED, C.
- Affiliations
- Environmental Protection Agency (US)
- National Institute of Standards and Technology (US)
- Corresponding author
- WALLACE, L A
- Venue
- Journal of Exposure Science & Environmental Epidemiology
- Published
- 2002-06-28
- Volume
- 12
- Issue
- 4
- Pages
- 296-306
- ISSN
- 1559-0631 (ISSN-L)
- 1559-064X
- OpenAlex
- W2067182986
- Semantic Scholar
- babd7df8b55b7dc377cad9f36becf006b33b8122
- Cited by
- 260
- References
- 19
- Citations by year
- 2026: 4 · 2025: 12 · 2024: 8 · 2023: 9 · 2022: 19 · 2021: 18 · 2020: 18 · 2019: 23 · 2018: 20 · 2017: 14 · 2016: 8 · 2015: 18 · 2014: 19 · 2013: 14 · 2012: 10
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Journal of Exposure Science & Environmental Epidemiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
- Keywords
- occupied houses, window openings, exhaust fan, indoor-outdoor temperature difference, wind speed, indoor humidity, sulfur hexafluoride, indoor air mixing
- MeSH terms
- Air Movements, Environmental Exposure, Environmental Monitoring, Gases, Housing, Humans, Humidity, Reference Values, Temperature, Ventilation, Wind, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.