Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A year-long investigation of air change rates in an occupied house was undertaken to establish the effects of temperature, wind velocity, use of exhaust fans, and window-opening behavior. Air change rates were calculated by periodically injecting a tracer gas (SF(6)) into the return air duct and measuring the concentration in 10 indoor locations sequentially every minute by a gas chromatograph equipped with an electron capture detector. Temperatures were also measured outdoors and in the 10 indoor locations. Relative humidity (RH) was measured outdoors and in five indoor locations every 5 min. Wind speed and direction in the horizontal plane were measured using a portable meteorological station mounted on the rooftop. Use of the thermostat-controlled attic fan was recorded automatically. Indoor temperatures increased from 21 degrees C in winter to 27 degrees C in summer. Indoor RH increased from 20% to 70% in the same time period. Windows were open only a few percent of the time in winter but more than half the time in summer. About 4600 hour-long average air change rates were calculated from the measured tracer gas decay rates. The mean (SD) rate was 0.65 (0.56) h(-1). Tracer gas decay rates in different rooms were very similar, ranging only from 0.62 to 0.67 h(-1), suggesting that conditions were well mixed throughout the year. The strongest influence on air change rates was opening windows, which could increase the rate to as much as 2 h(-1) for extended periods, and up to…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“which are irritants to the eyes, mucous membranes and upper respiratory tract [60, 80, 81].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [80]
Citations
Cites
Building ventilation: theory and measurement
(1997) · Choice Reviews Online · doi:10.5860/choice.35-2135 · Cited by 734 · cited 1×
“Instead, the observed slope will have a positive bias with respect to the air change rate, the magnitude of the bias being dependent on the amount of Journal of Exposure Analysis and Environmental Epidemiology (2002) 12(4) 301 interzonal flow (Etheridge and Sandberg, 1996).”
BackgroundMurray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 2×
“Air change rates have been measured in several thousand homes in the US (Murray and Burmaster, 1995), but most of these were one- time measurements made over short periods of 12 h to several weeks, making it impossible to determine the effects on air change rates of weather conditions and homeowner behavior such as wi…”
BackgroundThe Effect of Opening Windows on Air Change Rates in Two Homes
Howard-Reed, C., Wallace, L. A., & Ott, W. R. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470775 · Cited by 218 · cited 5×
“One recent study has provided quantitative information on the effect in two homes of opening windows to measured widths (Howard-Reed et al., 2002), but may have lacked sufficient measurements to derive a robust relationship with temperature and wind.”
BackgroundResultInfluentialSelf-citationRadon transport into a detached one-story house with a basement
Nazaroff, W. W., Feustel, H. E., Nero, A. V., Revzan, K. L., Grimsrud, D. T., Essling, M. A., & Toohey, R. E. (1985) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(85)90134-9 · Cited by 111 · cited 2×
“A positive intercept of similar magnitude (0.13–0.16 h 1) for a multiple regression including wind speed and either pressure or temperature difference was also noted in the study of Nazaroff et al. (1985) (our calculations based on their Table 2) .”
BackgroundResultInfluentialVentilation Research in Occupied Houses.
Dick, J. B., & Thomas, D. (1951) · Cited by 56
Measured Air Leakage of Buildings
Trechsel, H., & Lagus, P. L. (1986) · doi:10.1520/stp904-eb · Cited by 38 · cited 1×
“Two ASTM publications (Hunt et al., 1980; Trechsel and Lagus, 1986) provide convenient collections of papers on air leakage measurements.”
BackgroundThe Fundamentals of Natural Ventilation of Houses.
Dick, J. B. (1950) · Cited by 30
Field studies of dependence of air infiltration on outside temperature and wind
Malik, N. (1978) · Energy and Buildings · doi:10.1016/0378-7788(78)90008-7 · Cited by 27 · cited 2×
“Many find no effect of wind direction, but others (Malik, 1978) find that direction is important.”
BackgroundField measurements of air infiltration in ten elec-trically-heated houses.
Coblentz, C. W., & Achenbach, P. (1963) · Cited by 26
Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building
Emmerich, S. J., & Nabinger, S. J. (2000) · doi:10.6028/nist.ir.6461 · Cited by 24
Self-citation
Research works printed but not linked: 3
- Bahnfleth DR Moseley TT Harris WS Measurement of infiltration in two residences: Part I. Technique and measured infiltration, ASHRAE Trans (1957) 63: 453–476
- Lagus PL Air leakage measurements by the tracer dilution method In: Hunt C.M., King J.C., and Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980 pp 16–49
- Laschober RR Healy JH Statistical analyses of air leakage in split-level residences, ASHRAE Trans (1964) 70: 364–374
Cited by
Items 101–200 of 200
Estimation of PM2.5 infiltration factors and personal exposure factors in two megacities, China
Li, N., Liu, Z., Li, Y., Li, N., Chartier, R., McWilliams, A., Chang, J., Wang, Q., Wu, Y., Xu, C., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.033 · Cited by 44
Mašková, L., Smolík, J., & Ďurovič, M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.009 · Cited by 37
Güneş, G., Yalçın, N., & Çolaklar, H. (2022) · Environmental Monitoring and Assessment · doi:10.1007/s10661-022-09818-8 · Cited by 41
“Since autumn is a transition season, the temperature difference between indoor and outdoor environments is lower in this season than in winter (Wallace et al., 2002; Wu et al., 2018).”
BackgroundDai, X., Liu, J., Zhang, X., & Chen, W. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.05.017 · Cited by 34
Zhou, P., Wang, H., Li, F., Dai, Y., & Huang, C. (2021) · Energy and Built Environment · doi:10.1016/j.enbenv.2021.03.003 · Cited by 34
The influence of opening windows and doors on the natural ventilation rate of a residential building
Marr, D., Mason, M., Mosley, R., & Liu, X. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.585423 · Cited by 34
“Indoor-to-outdoor temperature differences, opening size and duration, outdoor wind effects, and window geometry (Jong and Bot 1992) have been shown to directly affect the air exchange rate (AER) of a building (Wallace et al. 2002; Howard-Reed et al. 2002; Jordan et al. 1963).”
BackgroundWeichenthal, S., Dufresne, A., Infante‐Rivard, C., & Joseph, L. (2006) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500534 · Cited by 34
“In homes, simply opening windows can have a dramatic effect on air exchange rates (Wallace et al., 2002); however, this relationship was not addressed in the current study as windows are generally kept closed in Canada during the winter months.”
BackgroundStephens, B. (2015) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.961849 · Cited by 33
Detection of occupant actions in buildings through change point analysis of in-situ measurements
Pereira, P. F., & Ramos, N. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.05.050 · Cited by 34
Moeller, S., Weber, I., Schröder, F., Bauer, A., & Harter, H. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109887 · Cited by 41
Wallace, L. A. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500365363 · Cited by 33
Self-citationDeveloping a design framework to facilitate adaptive behaviours
Korsavi, S. S., Montazami, A., & Brusey, J. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.09.011 · Cited by 35
“Contextually, studies have shown that window operation is affected by temperature and seasonal changes [32], [107]–[119], CO2 level [3], [4], [114], [117], [120], wind speed [32], [110], [111], relative humidity [108], [111], [113], [114], solar radiation [32], [112], precipitation levels [32], and background noise le…”
BackgroundInfluentialLioy, P. J. (2006) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500456 · Cited by 37
“(Spengler et al., 2001; Wallace et al., 2002; Hood, 2004; Johnson et al., 2004).”
Maisey, S., Saunders, S. M., West, N., & Franklin, P. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.09.008 · Cited by 39
Tools to improve built environment data collection for indoor microbial ecology investigations
Ramos, T., & Stephens, B. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.07.004 · Cited by 34
“, CO2 or SF6) Costly, labor and equipment intensive, requires injection and well-mixed environment [111–115]”
BackgroundRoscales, J. L., Muñoz-Arnanz, J., Ros, M., Vicente, A., Barrios, L., & Jiménez, B. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.03.043 · Cited by 32
Rosofsky, A., Levy, J. I., Breen, M. S., Zanobetti, A., & Fabian, M. P. (2018) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-018-0068-3 · Cited by 37
Zhou, S., Young, C. J., VandenBoer, T. C., & Kahan, T. F. (2019) · Environmental Science Processes & Impacts · doi:10.1039/c9em00129h · Cited by 40
Psomas, T., Heiselberg, P., Lyme, T., & Duer, K. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.12.019 · Cited by 31
Zeng, J., Mekić, M., Xu, X., Loisel, G., Zhou, Z., Gligorovski, S., & Li, X. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c05100 · Cited by 32
Effect of an Ionic Air Cleaner on Indoor/Outdoor Particle Ratios in a Residential Environment
Berry, D., Mainelis, G., & Fennell, D. E. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701199702 · Cited by 34
“AER was not determined in this study, but a survey of 349 residences found that the AER had an average value of 1.06 hr−1 (Meng et al. 2005).”
BackgroundInfluentialLei, X., Chen, R., Wang, C., Shi, J., Zhao, Z., Li, W., Bachwenkizi, J., Ge, W., Sun, L., Li, S., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105786 · Cited by 32
The impact of photocatalytic paint porosity on indoor NOx and HONO levels
Gandolfo, A., Bartolomei, V., Truffier‐Boutry, D., Temime‐Roussel, B., Brochard, G., Bergé, V., Wortham, H., & Gligorovski, S. (2019) · Physical Chemistry Chemical Physics · doi:10.1039/c9cp05477d · Cited by 29
Guo, S., Yan, D., & Gui, C. (2020) · Building Simulation · doi:10.1007/s12273-020-0617-2 · Cited by 31
“The ventilation rate was set to five air changes per hour when windows were open (Wallace et al. 2002).”
BackgroundA Discussion Regarding the Measurement of Ventilation Rates Using Tracer Gas and Decay Technique
Almeida, R. M. S. F., Barreira, E., & Moreira, P. (2020) · Infrastructures · doi:10.3390/infrastructures5100085 · Cited by 32
Occupant influence on residential ventilation patterns in mild climate conditions
Pereira, P. F., Ramos, N., Almeida, R. M. S. F., Simões, M. L., & Barreira, E. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.09.669 · Cited by 29
Won, Y., Waring, M. S., & Rim, D. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b06315 · Cited by 30
Sun, L., Wallace, L. A., Dobbin, N. A., You, H., Kulka, R., Shin, T., St-Jean, M., Aubin, D., & Singer, B. C. (2018) · Aerosol Science and Technology · doi:10.1080/02786826.2018.1524572 · Cited by 31
“…if feasible, keeping range hood on during cooking and continuing use with some times after cooking, opening windows, and/or running an HVAC system (Wallace, Emmerich, and Howard-Reed 2002, 2004b; Howard-Reed, Wallace, and Emmerich 2003; Zhang et al. 2010; Delp and Singer 2012; Singer et al. 2012;…”
BackgroundSelf-citationRedistribution of PM2.5‐associated nitrate and ammonium during outdoor‐to‐indoor transport
Liu, C., Wang, H., & Guo, H. (2019) · Indoor Air · doi:10.1111/ina.12549 · Cited by 29
Kang, K., Doroudi, S., Delasay, M., & Wickeham, A. (2023) · Production and Operations Management · doi:10.1111/poms.13675 · Cited by 42
“…is likely to require analytic techniques that are beyond the scope of this paper (and would be likely to hinder tractability) (e.g., see the processes in Section 4 of Zhang et al., 2015) and necessitate factoring in idiosyncrasies of a particular system (see Wallace et al., 2002, for instance).”
BackgroundEffects of future temperature change on PM2.5 infiltration in the Greater Boston area
Lee, W.-C., Shen, L., Catalano, P. J., Mickley, L. J., & Koutrakis, P. (2016) · Atmospheric Environment · doi:10.1016/j.atmosenv.2016.11.027 · Cited by 27
“These occupant behaviors are highly correlated predictors and were found to significantlymediate air exchange rate, which in turn influences Sr as shown previously by the steady state mass balance equation (Howard-Reed et al., 2002; Wallace et al., 2002; Yamamoto et al., 2010).”
BackgroundSpatial distributions of ozonolysis products from human surfaces in ventilated rooms
Won, Y., Lakey, P. S. J., Morrison, G., Shiraiwa, M., & Rim, D. (2020) · Indoor Air · doi:10.1111/ina.12700 · Cited by 26
Niu, B., Li, D., Yu, H., Mahyuddin, N., Liu, Y., Wu, J., Wang, X., & Pan, S. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103441 · Cited by 30
Effectiveness of urban shelter-in-place—II: Residential districts
Chan, W. R., Nazaroff, W. W., Price, P. N., & Gadgil, A. J. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.04.059 · Cited by 26
“Operation of exhaust or heating and cooling system fans can also increase air-exchange rates, but likely to a lesser extent than open windows (Wallace et al., 2002).”
BackgroundLevie, D., de Kluizenaar, Y., Oeffelen, E. C. M. H.-V., Hofstetter, H., Janssen, S. A., Spiekman, M., & Koene, F. G. H. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.09.008 · Cited by 26
Air exchange rates from atmospheric CO2 daily cycle
Carrilho, J. D., Mateus, M., Batterman, S., & da Silva, M. G. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.01.062 · Cited by 25
“Since the 1980s, automated and continuous measurements of AERs have been obtained by maintaining a constant concentration of a tracer gas using a PID controller, and calculating AERs from the quantity of tracer gas injected that is needed maintain the concentration [16,17].”
MethodEstimating climate change-related impacts on outdoor air pollution infiltration
Liang, D., Lee, W.-C., Liao, J., Lawrence, J. E., Wolfson, J. M., Ebelt, S., Kang, C., Koutrakis, P., & Sarnat, J. A. (2021) · Environmental Research · doi:10.1016/j.envres.2021.110923 · Cited by 24
Thermal Comfort and Sleep Quality of Indonesian Students Living in Japan during Summer and Winter
Budiawan, W., & Tsuzuki, K. (2021) · Buildings · doi:10.3390/buildings11080326 · Cited by 28
“Previous studies reported that the temperature and humidity variation are influenced by proximity to heat or humidity sources (laundry, shower, and kitchen) [30].”
BackgroundLitti, G., & Audenaert, A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.12.014 · Cited by 25
“Wallace [32], after continuous measurement of the building infiltration rate, it was concluded that the latter increases with indoor-outdoor temperature difference increase.”
BackgroundResultInfluentialEstimation of the real-time infiltration rate using a low carbon dioxide concentration
Park, S., Choi, P., Song, D., & Koo, J.-M. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102835 · Cited by 25
Yang, Y., Wang, W., Chen, C., Lu, T., & Liao, C. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s171510 · Cited by 27
“This translates into air flow of 24 m(3) h−1 for a 48 m(3) room to meet the recommended standards.(15,28) It has been estimated that the average short-term air exchange rate in the US is 0.”
BackgroundEffectiveness of urban shelter-in-place—I: Idealized conditions
Chan, W. R., Nazaroff, W. W., Price, P. N., & Gadgil, A. J. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.041 · Cited by 23
Air infiltration in Catalan dwellings and sealed rooms: An experimental study
Montoya, M. I., Pastor, E., & Planas, E. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.04.009 · Cited by 22
Salehi, A., Torres, I. M., & Ramos, A. (2017) · Sustainable Cities and Society · doi:10.1016/j.scs.2017.04.018 · Cited by 22
Air Change Rates in Residential Buildings in Tianjin, China
Hou, J., Zhang, Y., Sun, Y., Wang, P., Zhang, Q., Kong, X., & Sundell, J. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.10.069 · Cited by 23
Dhamodharan, P., & Ayalur, B. K. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106321 · Cited by 23
Wang, Y., Tahmasebi, F., Cooper, E., Stamp, S., Chalabi, Z., Burman, E., & Mumovic, D. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108260 · Cited by 24
Impact of Low-Income Occupant Behavior on Energy Consumption in Hot-Humid Climates
Nahmens, I., Joukar, A., & Cantrell, R. A. (2014) · Journal of Architectural Engineering · doi:10.1061/(asce)ae.1943-5568.0000162 · Cited by 20
Shiue, A., & Hu, S.-C. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.01.006 · Cited by 21
Window Use in Mixed-Mode Buildings: A Literature Review
Ackerly, K., Baker, L., & Brager, G. S. (2011) · eScholarship (California Digital Library) · Cited by 21
MacNeill, M., Dobbin, N. A., St-Jean, M., Wallace, L. A., Marro, L., Shin, T., You, H., Kulka, R., Allen, R. W., & Wheeler, A. J. (2015) · Indoor Air · doi:10.1111/ina.12252 · Cited by 22
“Adjusted models included outdoor pollutant concentrations, absolute indoor–outdoor temperature differences (Emmerich et al., 2004; Wallace et al., 2002), and window opening (where sufficient window opening was reported) as covariates.”
BackgroundSelf-citationPark, H.-G., Park, S., & Seo, J. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17155561 · Cited by 22
Mohammadi, M., & Calautit, J. K. (2022) · Sustainability · doi:10.3390/su141710880 · Cited by 22
Experimental and kinetic model evaluation of HONO production from surface nitrate photolysis
Wang, Y., Wang, J., Wang, Y., Zhang, Y., Woodward-Massey, R., Zhang, C., Kuang, Y., Zhu, J., Shang, J., Li, X., et al. (2022) · Atmospheric Environment · doi:10.1016/j.atmosenv.2022.119568 · Cited by 19
Chan, W. R. (2006) · Cited by 24
Chemical composition of household malodours – an overview
Hammond, C. J. (2013) · Flavour and Fragrance Journal · doi:10.1002/ffj.3163 · Cited by 21
Representing Small Commercial Building Faults in EnergyPlus, Part II: Model Validation
Kim, J.-H., Frank, S., Im, P., Braun, J. E., Goldwasser, D., & Leach, M. (2019) · Buildings · doi:10.3390/buildings9120239 · Cited by 19
Estimation of Generic Subslab Attenuation Factors for Vapor Intrusion Investigations
Brewer, R., Nagashima, J., Rigby, M. C., Schmidt, M., & O'Neill, H. (2014) · Groundwater Monitoring & Remediation · doi:10.1111/gwmr.12086 · Cited by 18
“The use of open doors and windows for cooling during longer periods of the year can also increase the IAER by a factor of three or more (Wallace et al. 2002; Marr et al. 2012; Bennett et al. 2012).”
BackgroundExploration of a long-term measurement approach for air change rate
Alavy, M., Li, T., & Siegel, J. A. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.051 · Cited by 21
Fazli, T., Dong, X., Fu, J. S., & Stephens, B. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c06308 · Cited by 25
Mašková, L., Smolík, J., Ondráček, J., Ondráčková, L., Trávníčková, T., & Havlica, J. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107024 · Cited by 17
Physical environment research of the family ward for a healthy residential environment
Zhang, Y., Liu, X., Meng, Q., Li, B., & Caneparo, L. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.1015718 · Cited by 19
“Humans generally adapt to indoor physical environments through behavioral, physiological, and psychological adaptations (62); for example, by opening or closing windows and curtains, the thermal and light environments in the physical environment elements can be regulated (63), including increasing indoor airflow (64).”
BackgroundXu, J., Deng, H., Wang, Y., Li, P., Zeng, J., Pang, H., Xu, X., Li, X., Yang, Y., & Gligorovski, S. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.160867 · Cited by 17
Xia, T., Raneses, J. M., Schmiesing, B., Garcia, R., Walding, A., DeMajo, R., Schulz, A. J., & Batterman, S. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1427116 · Cited by 17
Actions, attitudes and beliefs of occupants in managing dampness in buildings
Blay, K. B., Agyekum, K., & Opoku, A. (2018) · International Journal of Building Pathology and Adaptation · doi:10.1108/ijbpa-06-2018-0044 · Cited by 16
“The 3 to 4 hours aeration findings in this research concurs with that found by Wallace et al. (2002) in Virginia United States on the number of hours to aerate a town house.”
ResultZhu, X., Lv, M., & Yang, X. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.03.018 · Cited by 17
Wallace, L. A., & Ott, W. R. (2023) · Sensors · doi:10.3390/s23031160 · Cited by 17
Self-citationLiang, W., & Qiu, X. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113363 · Cited by 22
VALIDATION OF CONTAMW PREDICTIONS FOR TRACER GAS IN A TOWNHOUSE
Emmerich, S. J., Nabinger, S. J., Gupte, A., & Howard-Reed, C. (2003) · Cited by 15
Self-citationParticulate matter exposure from different heating stoves and fuels in UK homes
Kuye, A., & Kumar, P. (2025) · Scientific Reports · doi:10.1038/s41598-025-05886-1 · Cited by 21
Impact of ventilation methods on indoor particle concentrations in a daycare center
Park, J. S., Yoo, J., & Jeong, J. (2022) · Indoor Air · doi:10.1111/ina.13150 · Cited by 14
Air change rates and radon accumulation in rooms with various levels of window and door closure
Becker, R., Haquin, G., & Kovler, K. (2013) · Journal of Building Physics · doi:10.1177/1744259113506071 · Cited by 14
“Similar findings were obtained in the United States in a three-story family house in Virginia (Wallace et al., 2002), in a two-story family house in California, and a three-story apartment in a townhouse in Virginia (Howard-Reed et al.”
ResultContributions of indoor and outdoor sources to airborne polycyclic aromatic hydrocarbons indoors
Shi, S. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.001 · Cited by 17
Associating occupants' interaction with windows with air change rate --One case study
Liu, S., Jian, Y., Liu, J., Guo, R., & Zhu, W. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109387 · Cited by 16
An approach to predicting indoor radon concentration based on depressurisation measurements
McGrath, J. A., & Byrne, M. A. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20924747 · Cited by 14
Particle Deposition and Decay in a Chamber and the Implications to Exposure Assessment
Lai, A. C. K. (2006) · Water Air & Soil Pollution · doi:10.1007/s11270-006-9141-y · Cited by 14
“2 and 2 hr−1 are chosen to represent low and high values encountered in natural ventilation for buildings (Wallace et al., 2002).”
BackgroundDeng, H., Qiu, J., Zhang, R., Xu, J., Qu, Y., Wang, J., Liu, Y. J., & Gligorovski, S. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c08196 · Cited by 13
Assessing the impact of filtration systems in indoor environments with effectiveness
Li, T., & Siegel, J. A. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107389 · Cited by 13
Cosar-Jorda, P., Buswell, R. A., & Mitchell, V. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.08.053 · Cited by 11
“The average ACRs vary from 0.5h−1 to 2.6h−1 which corroborates the work of others (EST, 2014; Bedford et al., 1943; Fabi et al., 2012), and are within the320 bounds of uncertainty of the estimates found by Wallace et al. (2002).”
BackgroundResultInfluentialA new PM2.5-based PM-up method to measure non-mechanical ventilation rate in buildings
Hu, H., Huang, X., Zhao, Y., Qian, H., & Liu, C. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104351 · Cited by 11
Altaf, M. S., Hashisho, Z., & Al‐Hussein, M. (2014) · Canadian Journal of Civil Engineering · doi:10.1139/cjce-2013-0230 · Cited by 11
Occupants’ windows opening behaviour in residences during heating season in Tianjin, China
Hou, J., Zhang, Y., Sun, Y., Song, Y., Cheng, R., & Luo, S. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.10.189 · Cited by 11
Park, C., Jang, J., & Jang, J. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.4c14065 · Cited by 10
Residential inter-zonal ventilation rates for exposure modeling
Jayjock, M. A., & Havics, A. A. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1438615 · Cited by 10
Weather-based operation strategy for a dynamically compartmentalized double-skin façade system
Yoon, N., & Heo, Y. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109755 · Cited by 9
Field Study of Air Exchange Rates in Northern Highlands of Peru
Williams, P. R. D., & Unice, K. M. (2013) · Environmental Forensics · doi:10.1080/15275922.2013.814182 · Cited by 8
“Second, a number of studies in the United States have reported relatively high AERs (up to 16 h−1) in residences when exterior doors and windows are open (Howard-Reed et al., 2002; Wallace et al., 2002; Johnson et al., 2004), and AERs were found to be higher during the summer in certain regions due to natural ventilat…”
BackgroundKIN SELECTION AND EVOLUTION OF INFECTIOUS DISEASE RESISTANCE
Schliekelman, P. (2007) · Evolution · doi:10.1111/j.1558-5646.2007.00122.x · Cited by 9
Rout, R. P., Mishra, R., Prajith, R., Jalaluddin, S., & Sapra, B. K. (2014) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-014-3610-3 · Cited by 9
THE IMPACT OF OCCUPANT BEHAVIOUR ON RESIDENTIAL GREENHOUSE GAS EMISSIONS REDUCTION
Hetherington, J., Roetzel, A., & Fuller, R. (2015) · Journal of Green Building · doi:10.3992/jgb.10.4.127 · Cited by 11
Grešner, P., Świercz, R., Król, M. B., Twardowska, E., Gromadzińska, J., & Wąsowicz, W. (2016) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-016-0125-6 · Cited by 9
“Available studies indicate that in occupied houses, the ventilation behavior varies throughout the year and that it may significantly influence the rate of air exchange in rooms [44].”
BackgroundCho, K., Cho, D.-W., & Kim, T. (2021) · Sustainability · doi:10.3390/su131810302 · Cited by 8
“Notably, the infiltration rate may vary depending on the season [23]; the infiltration rate calculation experiment in this study was conducted in March and April when the CO2”
MethodWang, Y., Cooper, E., Tahmasebi, F., Chalabi, Z., Stamp, S., Burman, E., & Mumovic, D. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112562 · Cited by 8
Rossner, A., Jordan, C. E., Wake, C. P., & Soto-Garcia, L. (2017) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2017.1321054 · Cited by 10
“Wallace et al. found that for most homes air change rates, assuming windows closed, ranged from 0.30 to 1.9 (Wallace et al., 2002; Howard-Reed et al., 2002) per hour.”
BackgroundInfluentialHahn, I., Brixey, L. A., Wiener, R. W., & Henkle, S. W. (2009) · Journal of Environmental Monitoring · doi:10.1039/b907140g · Cited by 8
Radiant Slab Cooling: A Case Study of Building Energy Performance
Tian, Z., & Love, J. A. (2006) · IBPSA-USA Building Simulation Conference (SimBuild) · doi:10.26868/30680611.2006.sb06_238_244 · Cited by 8
“…rates with open windows is not the purpose of this research, the infiltration flow rates were approximated at 1.2 (June and August) and 1.4 (July) air changes/hour (ACH) (Wallace et al. 2002), gradually reduced to 0.2 ACH during the coldest months when it was observed that few windows were opened.”
BackgroundMethodInfluentialRajapakse, M. Y., Pistochini, T., Borras, E., McCartney, M. M., & Davis, C. E. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4243275 · Cited by 12
Building energy saving potential from the occupant dimension: A critical review
Li, Z., & Xu, X. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.112355 · Cited by 17
Park, S.-K., Lee, H.-J., Song, E., Kim, Y., Kim, D. Y., Lee, J., Yoo, H. J., Oh, J.-E., & Kwon, J.-H. (2021) · Environment International · doi:10.1016/j.envint.2021.106581 · Cited by 7
Jian, Y., Shao, X., Gai, X., Liu, S., Chen, C., & Liu, S. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114038 · Cited by 6
Assessing the variability of the air change rate through tracer gas measurements
Almeida, R. M. S. F., Barreira, E., & Moreira, P. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.10.013 · Cited by 6
Metadata
- Authors
- WALLACE, L. A., EMMERICH, S. J., & HOWARD-REED, C.
- Affiliations
- Environmental Protection Agency (US)
- National Institute of Standards and Technology (US)
- Corresponding author
- WALLACE, L A
- Venue
- Journal of Exposure Science & Environmental Epidemiology
- Published
- 2002-06-28
- Volume
- 12
- Issue
- 4
- Pages
- 296-306
- ISSN
- 1559-0631 (ISSN-L)
- 1559-064X
- OpenAlex
- W2067182986
- Semantic Scholar
- babd7df8b55b7dc377cad9f36becf006b33b8122
- Cited by
- 260
- References
- 19
- Citations by year
- 2026: 4 · 2025: 12 · 2024: 8 · 2023: 9 · 2022: 19 · 2021: 18 · 2020: 18 · 2019: 23 · 2018: 20 · 2017: 14 · 2016: 8 · 2015: 18 · 2014: 19 · 2013: 14 · 2012: 10
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Journal of Exposure Science & Environmental Epidemiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
- Keywords
- occupied houses, window openings, exhaust fan, indoor-outdoor temperature difference, wind speed, indoor humidity, sulfur hexafluoride, indoor air mixing
- MeSH terms
- Air Movements, Environmental Exposure, Environmental Monitoring, Gases, Housing, Humans, Humidity, Reference Values, Temperature, Ventilation, Wind, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.