Cited by 64Central Venous Catheters and HemodialysisVascular Procedures and ComplicationsCardiovascular Conditions and Treatments

The Use of Topical Nitroglycerin Ointment to Treat Peripheral Tissue Ischemia Secondary to Arterial Line Complications in Neonates

Baserga, Mariana C, Puri, Asha, Sola, Augusto·2002·Journal of Perinatology

Abstract

Catheterization of the aorta through the umbilical artery and/or of peripheral arteries in neonates may be accompanied by a number of complications, of which thrombotic phenomena and peripheral vasospasm are the most common. Two neonates with peripheral ischemia caused by vasospasm from indwelling umbilical artery catheterization and one infant with left hand ischemia due to a left radial artery line were successfully treated with 2% nitroglycerin ointment. No adverse effects were noted.

Integrity signals

Registry

Crossref · 10.1038/sj.jp.7210713

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Continuous monitoring of certain vital signs such as blood pressure demands additional wired hardware such as peripheral and umbilical arterial catheters, which can induce complications including thrombus formation, occlusion, infection, rupture, pseudoaneurysm, bleeding, and death.

    “Furthermore, continuous monitoring of certain vital signs, such as blood pressure, demands additional wired hardware, such as peripheral and umbilical arterial catheters4, which can induce other types of complications, including thrombus formation and occlusion, infection (e.g. sepsis), rupture, pseudoaneurysm, bleeding, and death5–7.”
  • Arterial lines for continuous blood pressure measurement in neonates can cause thrombosis, hematomas, infection, and even death.

    “Although arterial lines offer a continuous measurement of blood pressure in neonates, these invasive interventions can cause thrombosis, hematomas, infection, and even death (34).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Baserga, M. C., Puri, A., & Sola, A.
Affiliations
Cedars-Sinai Medical Center (US)
Venue
Journal of Perinatology
Published
2002-06-27
Volume
22
Issue
5
Pages
416-419
ISSN
  • 0743-8346 (ISSN-L)
  • 1476-5543
OpenAlex
W2062978805
Cited by
64
References
14
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 11 · 2020: 5 · 2019: 2 · 2018: 1 · 2017: 2 · 2015: 1 · 2014: 4 · 2013: 3 · 2012: 5
FWCI
1.53
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Perinatology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Emergency Medical Services › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiovascular Conditions and Treatments
Keywords
peripheral vasospasm, thrombosis, radial artery catheterization
MeSH terms
Catheterization, Peripheral, Catheters, Indwelling, Female, Nitroglycerin, Humans, Infant, Newborn, Ischemia, Male, Ointments, Umbilical Arteries, Vasodilator Agents

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review