CoChat

The interaction of asbestos and iron in lung tissue revealed by synchrotron-based scanning X-ray microscopy

Open access
Pascolo, Lorella, Gianoncelli, Alessandra, Schneider, Giulia, Salomé, Murielle, Schneider, Manuela, Calligaro, Carla, Kiskinova, Maya, Melato, Mauro, Rizzardi, Clara · 2013 · Scientific Reports

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index; 20 of the 45 sources its claims cite were checked for support.

Abstract

Asbestos is a potent carcinogen associated with malignant mesothelioma and lung cancer but its carcinogenic mechanisms are still poorly understood. Asbestos toxicity is ascribed to its particular physico-chemical characteristics, and one of them is the presence of and ability to adsorb iron, which may cause an alteration of iron homeostasis in the tissue. This observational study reports a combination of advanced synchrotron-based X-ray imaging and micro-spectroscopic methods that provide correlative morphological and chemical information for shedding light on iron mobilization features during asbestos permanence in lung tissue. The results show that the processes responsible for the unusual distribution of iron at different stages of interaction with the fibres also involve calcium, phosphorus and magnesium. It has been confirmed that the dominant iron form present in asbestos bodies is ferritin, while the concurrent presence of haematite suggests alteration of iron chemistry during asbestos body permanence.

Overview

CoChat Summary

TL;DR

Synchrotron-based X-ray fluorescence and XANES microscopy of lung tissue from asbestos-exposed patients shows that asbestos bodies and surrounding macrophages mobilize iron, with calcium, phosphorus, and magnesium also involved in coating formation. Iron in asbestos bodies is predominantly ferritin/ferrihydrite, with a notable haematite fraction suggesting chemical alteration during long-term body permanence.

Key findings

  • XRF elemental maps showed extremely high iron in asbestos bodies and nearby structures: up to 400 times the iron content of a blood vessel reference area, and Fe signal in the body, vesicles, and nearby regions up to 1000 times higher than non-affected tissue.
  • Fe K-edge XANES from asbestos bodies gave an average composition of 71% ferritin (ferrihydrite), 16% haematite, 12% crocidolite, and 1% metallic iron, indicating predominantly Fe3+ and ferritin as the dominant iron form.
  • Calcium, phosphorus, and magnesium participated in asbestos body formation: P and Ca were enriched in coatings, Ca was high in formed bodies but not around thin “naked” fibres, and Mg was present in thin coated fibre segments and strongly coated segments.
  • Asbestos body counts in the selected patients ranged from 10 × 10³ to 400 × 10³ bodies per gram of dry tissue.

Methods

  • Observational study of ten patients selected from a cohort of more than 200 former shipyard workers exposed to asbestos and autopsied with asbestos-related diseases; all had pulmonary asbestosis, one also lung cancer, and four also pleural mesothelioma.
  • Lung tissue sections were analysed by histology, Perls’ staining, and synchrotron X-ray microscopy: hard X-ray XRF/XANES at ID21 (ESRF) and soft X-ray absorption/phase contrast and XRF at TwinMic (Elettra), covering about 20 tissue slices and about thirty asbestos bodies.
  • Elemental maps were deconvoluted with PyMCA; XANES spectra were baseline-subtracted, normalized, and fitted by linear combination using standards for ferritin, haematite, crocidolite, magnetite, metallic iron, and fayalite.

Limitations

  • The paper states that XANES could only be measured on sufficiently wide and flat asbestos bodies, and signal was insufficient for reliable microspot spectra from low-Fe regions surrounding the bodies.
  • The paper states that absolute quantification was difficult because suitable reference standards for inhomogeneous samples were lacking, so Fe, P, and Ca comparisons were semiquantitative.
  • Evident from the text: the study is observational and based on ten selected patients, with no unexposed control group described; the authors also report no characteristic chemical differences related to specific patient diagnosis.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/srep01123

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Histological examination of human lung tissue with asbestos bodies. Panel (a) and (b) are microphotographs from the histological sections used for the study, stained by hematoxilin and eosin. Diffuse fibrosis and asbestos bodies (black arrows) are evident. In panel (b) there are sparse macrophages (blue arrows) and an asbestos fibre is phagocytated by two macrophages (black arrow). Panel (c) and (d) show tissue sections colored with Perls' staining and positive staining of asbestos bodies (black arrows). Uncoated fibre parts are not stained (blue arrows). In (a), (b), (d) magnification is 40×, while in (c) is 60×.
Figure 1 Histological examination of human lung tissue with asbestos bodies. Panel (a) and (b) are microphotographs from the histological sections used for the study, stained by hematoxilin and eosin. Diffuse fibrosis and asbestos bodies (black arrows) are evident. In panel (b) there are sparse macrophages (blue arrows) and an asbestos fibre is phagocytated by two macrophages (black arrow). Panel (c) and (d) show tissue sections colored with Perls' staining and positive staining of asbestos bodies (black arrows). Uncoated fibre parts are not stained (blue arrows). In (a), (b), (d) magnification is 40×, while in (c) is 60×.CC BY-NC-ND · PubMed Central
Figure 2 μXRF and X-ray microscopy of tissue section containing asbestos. Visible light image of the unstained tissue section (a), 80 × 50 μm2 X-ray microscopy absorption image (b) and the corresponding Si, Ca, P, S, Fe and co-localisation (P-Si-S and P-Fe-Si) XRF maps (62 × 38 μm2) showing the distribution of different elements in a tissue section containing asbestos. The panels above the Fe map illustrate the Fe intensity profiles measured across lines indicated in the image. The absorption image was measured at the TwinMic beam line with photon energy 0.9 keV, whereas the XRF maps were acquired at ID21 beamline at 7.3 keV.
Figure 2 μXRF and X-ray microscopy of tissue section containing asbestos. Visible light image of the unstained tissue section (a), 80 × 50 μm2 X-ray microscopy absorption image (b) and the corresponding Si, Ca, P, S, Fe and co-localisation (P-Si-S and P-Fe-Si) XRF maps (62 × 38 μm2) showing the distribution of different elements in a tissue section containing asbestos. The panels above the Fe map illustrate the Fe intensity profiles measured across lines indicated in the image. The absorption image was measured at the TwinMic beam line with photon energy 0.9 keV, whereas the XRF maps were acquired at ID21 beamline at 7.3 keV.CC BY-NC-ND · PubMed Central
Figure 3 μXRF and X-ray microscopy of tissue section containing uncoated asbestos fibres. 65 × 80 μm2 X-ray microscopy absorption (a) and phase contrast (b) images and the corresponding XRF Ca, P, S, Si (45 × 60 μm2) and Fe (65 × 80 μm2) maps of a tissue section containing asbestos. These XRF maps were acquired at ID21 at 7.3 keV. The parallax mismatch between the images collected at the TwinMic beamline (absorption, phase contrast) and the ones acquired at the ID21 beamline (Fe, Ca and S) is due to the different geometrical set up of the two systems. In the TwinMic microscope the incoming beam hits the sample perpendicularly while at the ID21 beamline the sample is tilted of 30 degrees with respect to the incident X-ray beam. The 18 × 30 μm2 XRF maps Si_1 and Mg_1 and Fe_1 corresponding to area C (panel c), indicated in panel (a), and 30 × 30 μm2 Si_2 and Mg_2 corresponding to area D (panel d) were acquired with 1.9 keV at TwinMic.
Figure 3 μXRF and X-ray microscopy of tissue section containing uncoated asbestos fibres. 65 × 80 μm2 X-ray microscopy absorption (a) and phase contrast (b) images and the corresponding XRF Ca, P, S, Si (45 × 60 μm2) and Fe (65 × 80 μm2) maps of a tissue section containing asbestos. These XRF maps were acquired at ID21 at 7.3 keV. The parallax mismatch between the images collected at the TwinMic beamline (absorption, phase contrast) and the ones acquired at the ID21 beamline (Fe, Ca and S) is due to the different geometrical set up of the two systems. In the TwinMic microscope the incoming beam hits the sample perpendicularly while at the ID21 beamline the sample is tilted of 30 degrees with respect to the incident X-ray beam. The 18 × 30 μm2 XRF maps Si_1 and Mg_1 and Fe_1 corresponding to area C (panel c), indicated in panel (a), and 30 × 30 μm2 Si_2 and Mg_2 corresponding to area D (panel d) were acquired with 1.9 keV at TwinMic.CC BY-NC-ND · PubMed Central
Figure 4 Ferruginous body of an iron free asbestos fibre. 30 × 65 μm2 X-ray microscopy absorption (a) and phase contrast (b) images and the corresponding XRF Fe, Si, Ca (26 × 68 μm2) O and Mg (30 × 45 μm2) XRF maps of a ferruginous body developed on an iron-free asbestos fibre. The XRF spectra panel outlines the relative intensities of O, Fe and Mg in the spots indicated in panel A. The X-ray images, Mg and O maps and the XRF spectra were acquired with 1.5 keV photon energy, whereas the Fe, Si and Ca were taken at 7.3 keV. As in Figure 3, parallax mismatch must be considered between images collected at the TwinMic beamline (absorption, phase contrast, O and Mg maps) and those at the ID21.
Figure 4 Ferruginous body of an iron free asbestos fibre. 30 × 65 μm2 X-ray microscopy absorption (a) and phase contrast (b) images and the corresponding XRF Fe, Si, Ca (26 × 68 μm2) O and Mg (30 × 45 μm2) XRF maps of a ferruginous body developed on an iron-free asbestos fibre. The XRF spectra panel outlines the relative intensities of O, Fe and Mg in the spots indicated in panel A. The X-ray images, Mg and O maps and the XRF spectra were acquired with 1.5 keV photon energy, whereas the Fe, Si and Ca were taken at 7.3 keV. As in Figure 3, parallax mismatch must be considered between images collected at the TwinMic beamline (absorption, phase contrast, O and Mg maps) and those at the ID21.CC BY-NC-ND · PubMed Central
Figure 5 Tissue with phagocytated asbestos fibre. 80 × 20 μm2 X-ray microscopy absorption (a) and phase contrast (b) images and the corresponding XRF Fe, Si, P, S Ca (84 × 22 μm2) and Mg (62 × 20 μm2) XRF maps of a tissue with phagocytated asbestos fibre. Fe log is displayed using a logarithmic scale and Fe using a linear scale. The P-Ca-Si co-localization is illustrated below right. All images were acquired at 7.3 keV except the Mg map which was acquired at 1.5 keV. As in previous figures, parallax mismatch must be considered between images acquired at the TwinMic beamline (absorption, phase contrast and Mg map) and those at the ID21 beamline.
Figure 5 Tissue with phagocytated asbestos fibre. 80 × 20 μm2 X-ray microscopy absorption (a) and phase contrast (b) images and the corresponding XRF Fe, Si, P, S Ca (84 × 22 μm2) and Mg (62 × 20 μm2) XRF maps of a tissue with phagocytated asbestos fibre. Fe log is displayed using a logarithmic scale and Fe using a linear scale. The P-Ca-Si co-localization is illustrated below right. All images were acquired at 7.3 keV except the Mg map which was acquired at 1.5 keV. As in previous figures, parallax mismatch must be considered between images acquired at the TwinMic beamline (absorption, phase contrast and Mg map) and those at the ID21 beamline.CC BY-NC-ND · PubMed Central
Figure 6 XRF semi-quantitative analyses of Fe, P and Ca content in asbestos bodies and tissues. The table reports the comparative evaluation of Fe, P and Ca in the specific areas indicated in the Fe maps of Figure 2, 4 and 5 (right bottom panels). The values are indicated in terms of multiples of signal increase vs. the average content of four blood vessel areas (all normalized to 1 μm2) marked in figure S1, panel Fe. The bottom left graph shows the relative amount of Fe, Ca and P in the ten selected areas (as reported in the top table).
Figure 6 XRF semi-quantitative analyses of Fe, P and Ca content in asbestos bodies and tissues. The table reports the comparative evaluation of Fe, P and Ca in the specific areas indicated in the Fe maps of Figure 2, 4 and 5 (right bottom panels). The values are indicated in terms of multiples of signal increase vs. the average content of four blood vessel areas (all normalized to 1 μm2) marked in figure S1, panel Fe. The bottom left graph shows the relative amount of Fe, Ca and P in the ten selected areas (as reported in the top table).CC BY-NC-ND · PubMed Central
Figure 7 Micro-XANES analyses on asbestos bodies. An example of a deconvoluted micro-XANES spectrum of an asbestos body measured with a microprobe of 1 μm2.
Figure 7 Micro-XANES analyses on asbestos bodies. An example of a deconvoluted micro-XANES spectrum of an asbestos body measured with a microprobe of 1 μm2.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

13 Valid · 2 Not valid · 10 Not checked · 71 Own results and interpretations

52 more claims

Create a free account to see all 96 claims and to verify the 1 reference still open.

See all claims — free account
  • Probably not a substantial claim. 22
  • It may state two separate claims as one. 21

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 49 references

Research works printed but not linked: 1

  1. Morrison, G. R., Gianoncelli, A., Kaulich, B., Bacescu, D. & Kovac, J. A fast read-out CCD system for configured-detector imaging in STXM. Conf.Proc.Series IPAP 7, 277–379 (2006).

Cited by

Metadata

Authors
Pascolo, L., Gianoncelli, A., Schneider, G., Salomé, M., Schneider, M., Calligaro, C., Kiskinova, M., Melato, M., & Rizzardi, C.
Affiliations
  • IRCCS Materno Infantile Burlo Garofolo (IT)
  • Elettra-Sincrotrone Trieste S.C.p.A. (IT)
  • University of Trieste (IT)
  • Ospedale di Monfalcone (IT)
  • University of Udine (IT)
Corresponding author
Pascolo, Lorella
Venue
Scientific Reports
Published
2013-01-24
Volume
3
Issue
1
Pages
1123-1123
ISSN
2045-2322 (ISSN-L)
OpenAlex
W1994213943
Cited by
88
References
49
Citations by year
2025: 4 · 2024: 3 · 2023: 15 · 2022: 6 · 2021: 3 · 2020: 7 · 2019: 9 · 2018: 8 · 2017: 12 · 2016: 6 · 2015: 7 · 2014: 4 · 2013: 4
FWCI
4.99
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • HAL (submittedVersion, other-oa)
  • ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/) (submittedVersion)
Funders
Regione Autonoma Friuli Venezia Giulia
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
  • Physical Sciences › Earth and Planetary Sciences › Geochemistry and Petrology › Coal and Its By-products
Keywords
asbestos, iron, lung tissue, asbestos bodies, ferritin, hematite, iron homeostasis, asbestos fibers, calcium, phosphorus, magnesium, mesothelioma, lung cancer, synchrotron X-ray microscopy, microspectroscopy
MeSH terms
Aged, Aged, 80 and over, Asbestos, Asbestosis, Calcium, Carcinogens, Female, Ferritins, Humans, Iron, Lung, Magnesium, Male, Microscopy, Electron, Scanning, Phosphorus, X-Ray Absorption Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.