Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Cancer-driven dynamics of immune cells in a microfluidic environment

Open access
Agliari, Elena, Biselli, Elena, De Ninno, Adele, Schiavoni, Giovanna, Gabriele, Lucia, Gerardino, Anna, Mattei, Fabrizio, Barra, Adriano, Businaro, Luca · 2014 · Scientific Reports

Abstract

Scope of the present work is to infer the migratory ability of leukocytes by stochastic processes in order to distinguish the spontaneous organization of immune cells against an insult (namely cancer). For this purpose, spleen cells from immunodeficient mice, selectively lacking the transcription factor IRF-8 (IRF-8 knockout; IRF-8 KO), or from immunocompetent animals (wild-type; WT), were allowed to interact, alternatively, with murine B16.F10 melanoma cells in an ad hoc microfluidic environment developed on a LabOnChip technology. In this setting, only WT spleen cells were able to establish physical interactions with melanoma cells. Conversely, IRF-8 KO immune cells exhibited poor dynamical reactivity towards the neoplastic cells. In the present study, we collected data on the motility of these two types of spleen cells and built a complete set of observables that recapitulate the biological complexity of the system in these experiments. With remarkable accuracy, we concluded that the IRF-8 KO cells performed pure uncorrelated random walks, while WT splenocytes were able to make singular drifted random walks that collapsed on a straight ballistic motion for the system as a whole, hence giving rise to a highly coordinate response. These results may provide a useful system to quantitatively analyse the real time cell-cell interactions and to foresee the behavior of immune cells with tumor cells at the tissue level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep06639

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Micro-fluidic co-culture immune-cancer system: design and fabrication.
Figure 1 Micro-fluidic co-culture immune-cancer system: design and fabrication.CC BY-NC-ND · PubMed Central
Figure 2 Experimental design and methodologies: melanoma vs WT/KO immune cell interactions.
Figure 2 Experimental design and methodologies: melanoma vs WT/KO immune cell interactions.CC BY-NC-ND · PubMed Central
Figure 3 Differential migratory behavior of KO and WT cells toward melanoma cells. B16 melanoma cells (green-labeled) and spleen cells (red-labeled) from either WT or KO mice at 24 h (A) and 48 h (B) after loading onto the microfluidic device. (C) Detail of splenocytes interacting with B16 cells.
Figure 3 Differential migratory behavior of KO and WT cells toward melanoma cells. B16 melanoma cells (green-labeled) and spleen cells (red-labeled) from either WT or KO mice at 24 h (A) and 48 h (B) after loading onto the microfluidic device. (C) Detail of splenocytes interacting with B16 cells.CC BY-NC-ND · PubMed Central
Figure 4 Upper panel shows examples of real trajectories performed by WT cells, while lower panel depicts the same for KO cells. WT, but not KO, splenocytes migrate from top-right through bottom-left following a chemokine gradient.
Figure 4 Upper panel shows examples of real trajectories performed by WT cells, while lower panel depicts the same for KO cells. WT, but not KO, splenocytes migrate from top-right through bottom-left following a chemokine gradient.CC BY-NC-ND · PubMed Central
Figure 5 Prospect of the perturbation of B16 cells in microfluidic devices loaded with WT or IRF8 KO immune cells. (A) Perturbation factor has been calculated for three representative B16 cells (Mel1, Mel2, Mel3) taken in each device by depicting the area fraction of that cell in each timepoint respect to the preceding timepoint. This allowed to obtain the percentage area variation for each given timepoint for the 24–42 h time interval. The examined B16 cells were located in the melanoma compartment of the microfluidic devices. (B) Multiple comparison between B16 cells showed in panel A by Mann-Whitney U test. Each of three B16 cells from device loaded with WT immune cells (WT-Mel1, WT-Mel2, WT-Mel3) was combined with each of three B16 cells from device loaded with IRF8 KO immune cells (KO-Mel1, KO-Mel2, KO-Mel3).
Figure 5 Prospect of the perturbation of B16 cells in microfluidic devices loaded with WT or IRF8 KO immune cells. (A) Perturbation factor has been calculated for three representative B16 cells (Mel1, Mel2, Mel3) taken in each device by depicting the area fraction of that cell in each timepoint respect to the preceding timepoint. This allowed to obtain the percentage area variation for each given timepoint for the 24–42 h time interval. The examined B16 cells were located in the melanoma compartment of the microfluidic devices. (B) Multiple comparison between B16 cells showed in panel A by Mann-Whitney U test. Each of three B16 cells from device loaded with WT immune cells (WT-Mel1, WT-Mel2, WT-Mel3) was combined with each of three B16 cells from device loaded with IRF8 KO immune cells (KO-Mel1, KO-Mel2, KO-Mel3).CC BY-NC-ND · PubMed Central
Figure 6 Logarithm of the probability distribution for the step length along the x direction (upper panel) and along the y direction (lower panel). Experimental data (symbols) with standard errors are fitted by the exponential distribution (solid line) given by Eq. 8. All fits display R2 ≈ 0.99. The best fit coefficients are reported in Tab. I, where a comparison between average values from experiments and theoretical description is also provided.
Figure 6 Logarithm of the probability distribution for the step length along the x direction (upper panel) and along the y direction (lower panel). Experimental data (symbols) with standard errors are fitted by the exponential distribution (solid line) given by Eq. 8. All fits display R2 ≈ 0.99. The best fit coefficients are reported in Tab. I, where a comparison between average values from experiments and theoretical description is also provided.CC BY-NC-ND · PubMed Central
Figure 7 Inset: polar histogram of the turning angle. The distribution has zero mean, hence, no angular correlation is observed. Main plot: angular correlation function CKO(τ) of the turning angle θ. This correlation function shows more statistical noise at large τ.
Figure 7 Inset: polar histogram of the turning angle. The distribution has zero mean, hence, no angular correlation is observed. Main plot: angular correlation function CKO(τ) of the turning angle θ. This correlation function shows more statistical noise at large τ.CC BY-NC-ND · PubMed Central
Figure 8 Inset: binned data () with standard errors of mean instantaneous speed and related best fit (solid line). KO splenocytes do not slow down over the observation time of 350 frames. Thus, for practical purposes, we can consider them as being in a time-independent state. Main plot: mean step length for each KO cell (thin curve) and mean step length averaged over all splenocytes (thick curve) at each time, which is essentially constant.
Figure 8 Inset: binned data () with standard errors of mean instantaneous speed and related best fit (solid line). KO splenocytes do not slow down over the observation time of 350 frames. Thus, for practical purposes, we can consider them as being in a time-independent state. Main plot: mean step length for each KO cell (thin curve) and mean step length averaged over all splenocytes (thick curve) at each time, which is essentially constant.CC BY-NC-ND · PubMed Central
Figure 9 Mean displacement 〈r(t)〉 (upper panel) and mean squared displacement 〈r2(t)〉 (lower panel) for KO splenocytes. Experimental (binned) data () with standard errors are compared with best fits (solid line) whose coefficients are properly shown.
Figure 9 Mean displacement 〈r(t)〉 (upper panel) and mean squared displacement 〈r2(t)〉 (lower panel) for KO splenocytes. Experimental (binned) data () with standard errors are compared with best fits (solid line) whose coefficients are properly shown.CC BY-NC-ND · PubMed Central
Figure 10 Left panel: straightness index SKO for each KO splenocyte (thin curves) and straightness index averaged over all splenocytes (thick curve) at each time. Right panel: binned data for () with standard errors for KO splenocytes and best linear fit (solid line).
Figure 10 Left panel: straightness index SKO for each KO splenocyte (thin curves) and straightness index averaged over all splenocytes (thick curve) at each time. Right panel: binned data for () with standard errors for KO splenocytes and best linear fit (solid line).CC BY-NC-ND · PubMed Central
Figure 11 ψx(Δx) of WT-PRE splenocytes along the positive direction (upper panel, notice the semilogarithmic scale) and along the negative direction (lower panel, notice the logarithmic scale). Analogous plots are obtained for the y direction (not shown). Experimental data of the distributions () with standard errors are compared with best fits (solid line). Note that the distribution is broadened along the negative x direction (and, analogously, along the positive y direction).
Figure 11 ψx(Δx) of WT-PRE splenocytes along the positive direction (upper panel, notice the semilogarithmic scale) and along the negative direction (lower panel, notice the logarithmic scale). Analogous plots are obtained for the y direction (not shown). Experimental data of the distributions () with standard errors are compared with best fits (solid line). Note that the distribution is broadened along the negative x direction (and, analogously, along the positive y direction).CC BY-NC-ND · PubMed Central
Figure 12 ψx(Δx) of WT-POST splenocytes along the positive direction (upper panel, notice the semilogarithmic scale) and along the negative direction (lower panel, notice the logarithmic scale). Analogous plots are obtained for the y direction (not shown). Experimental data of the distributions () with standard errors are compared with best fits (solid line). Note that the distribution is broadened along the negative x direction (and, analogously, along the positive y direction).
Figure 12 ψx(Δx) of WT-POST splenocytes along the positive direction (upper panel, notice the semilogarithmic scale) and along the negative direction (lower panel, notice the logarithmic scale). Analogous plots are obtained for the y direction (not shown). Experimental data of the distributions () with standard errors are compared with best fits (solid line). Note that the distribution is broadened along the negative x direction (and, analogously, along the positive y direction).CC BY-NC-ND · PubMed Central
Figure 13 Left panels: angular correlation function CWT(τ) of the turning angle θ of WT-PRE splenocytes (upper panel) and of WT-POST splenocytes (lower panel). Each turn occours every 4 minutes. In both cases the correlation is mostly positive, meaning that the process has memory. In the inset we show the polar histogram of the angle measured with respect to the horizontal axis. Right panels: distribution of the turning angle for WT-PRE splenocytes (upper panel) and of WT-POST splenocytes (lower panel). The experimental distribution is fitted by a Gaussian peaked at 0 rad, since splenocytes tend to maintain the same direction. Note that the resulting Gaussian shape is in full agreement with the mathematical description of the motion in terms of a (biased and uncorrelated) stochastic process (further an analysis of its variance will be successfully exploited in the last section due to numerical simulations).
Figure 13 Left panels: angular correlation function CWT(τ) of the turning angle θ of WT-PRE splenocytes (upper panel) and of WT-POST splenocytes (lower panel). Each turn occours every 4 minutes. In both cases the correlation is mostly positive, meaning that the process has memory. In the inset we show the polar histogram of the angle measured with respect to the horizontal axis. Right panels: distribution of the turning angle for WT-PRE splenocytes (upper panel) and of WT-POST splenocytes (lower panel). The experimental distribution is fitted by a Gaussian peaked at 0 rad, since splenocytes tend to maintain the same direction. Note that the resulting Gaussian shape is in full agreement with the mathematical description of the motion in terms of a (biased and uncorrelated) stochastic process (further an analysis of its variance will be successfully exploited in the last section due to numerical simulations).CC BY-NC-ND · PubMed Central
Figure 14 Mean step length versus time for WT-PRE and WT-POST splenocytes (left and right panel, respectively). Results for each splenocyte (thin curves) are compared with the resulting average over all splenocytes (thick curve). In both cases, appears constant in time.
Figure 14 Mean step length versus time for WT-PRE and WT-POST splenocytes (left and right panel, respectively). Results for each splenocyte (thin curves) are compared with the resulting average over all splenocytes (thick curve). In both cases, appears constant in time.CC BY-NC-ND · PubMed Central
Figure 15 Mean instantaneous speed of WT-PRE splenocytes (upper panel) and of WT-POST splenocytes (lower panel). Binned data () with standard errors are best fitted by a constant line (solid curve). In both cases, no evident acceleration is observed, but, in the latter case, speed is lower.
Figure 15 Mean instantaneous speed of WT-PRE splenocytes (upper panel) and of WT-POST splenocytes (lower panel). Binned data () with standard errors are best fitted by a constant line (solid curve). In both cases, no evident acceleration is observed, but, in the latter case, speed is lower.CC BY-NC-ND · PubMed Central
Figure 16 〈r(t)〉 versus t for WT-PRE splenocytes (upper panel) and for WT-POST splenocytes (lower panel). As expected, the mean displacement grows linearly with time. Binned data () with standard errors are compared with best fit (solid line), whose coefficients are also reported.
Figure 16 〈r(t)〉 versus t for WT-PRE splenocytes (upper panel) and for WT-POST splenocytes (lower panel). As expected, the mean displacement grows linearly with time. Binned data () with standard errors are compared with best fit (solid line), whose coefficients are also reported.CC BY-NC-ND · PubMed Central
Figure 17 (◊) and 〈r2(t)〉 (○) vs t for WT-PRE splenocytes (upper panel) and for WT-POST splenocytes (lower panel). Symbols represent experimental data with standard errors, while the solid lines represent the best fits. Notice that, for both sets of splenocytes, and 〈r2(t)〉 are nicely overlapped, both growing with the square of time.
Figure 17 (◊) and 〈r2(t)〉 (○) vs t for WT-PRE splenocytes (upper panel) and for WT-POST splenocytes (lower panel). Symbols represent experimental data with standard errors, while the solid lines represent the best fits. Notice that, for both sets of splenocytes, and 〈r2(t)〉 are nicely overlapped, both growing with the square of time.CC BY-NC-ND · PubMed Central
Figure 18 Straightness index S for WT-PRE splenocytes (left panel) and for WT-POST splenocytes (right panel); the thick lines represent the related averages over all splenocytes at each time 〈S〉. As expected for a random walk with bias, it takes values close to 1.
Figure 18 Straightness index S for WT-PRE splenocytes (left panel) and for WT-POST splenocytes (right panel); the thick lines represent the related averages over all splenocytes at each time 〈S〉. As expected for a random walk with bias, it takes values close to 1.CC BY-NC-ND · PubMed Central
Figure 19 Comparison between experimental data (), their best fit (solid line) and data from numerical simulation (the area highlighted is centered on the average value, where the average is performed over N independent realizations, and spans over its standard deviation). The KO case (left panel), the WT-PRE case (central panel) and the WT-POST case (right panel) are all considered. Notice that experimental data and best fits are those previously reported in Figs. 9 and 16, respectively.
Figure 19 Comparison between experimental data (), their best fit (solid line) and data from numerical simulation (the area highlighted is centered on the average value, where the average is performed over N independent realizations, and spans over its standard deviation). The KO case (left panel), the WT-PRE case (central panel) and the WT-POST case (right panel) are all considered. Notice that experimental data and best fits are those previously reported in Figs. 9 and 16, respectively.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Research works printed but not linked: 2

  1. Galper, T., Marre, O., Amodei, D., Schneidman, E., Bialek, W., Berry, I. I. & Michael, J. Searching for collective behavior in a network of real neurons. preprint arXiv 1306–3061 (2013).
  2. Weiss, G. H. Aspects and applications of random walks, (North-Holl. Press, Amsterdam, 1994).

Cited by

See all 91

Metadata

Authors
Agliari, E., Biselli, E., De Ninno, A., Schiavoni, G., Gabriele, L., Gerardino, A., Mattei, F., Barra, A., & Businaro, L.
Affiliations
  • Sapienza University of Rome (IT)
  • Istituto Superiore di Sanità (IT)
  • Istituto di Fotonica e Nanotecnologie (IT)
Venue
Scientific Reports
Published
2014-10-16
Volume
4
Issue
1
Pages
6639-6639
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2007723697
Cited by
91
References
42
Citations by year
2026: 3 · 2025: 5 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 16 · 2020: 17 · 2019: 8 · 2018: 8 · 2017: 6 · 2016: 6 · 2015: 3
FWCI
4.81
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
  • AIRUS (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Istituto Nazionale di Alta Matematica "Francesco Severi"
  • Ministero della Salute (RF-2011-02347120)
  • Associazione Italiana per la Ricerca sul Cancro (#11610)
  • Gruppo Nazionale per la Fisica Matematica
Topics
  • Physical Sciences › Mathematics › Modeling and Simulation › Mathematical Biology Tumor Growth
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
Keywords
leukocyte migration, splenocytes, B16F10 melanoma, antitumor immunity, cell-cell interactions, random walks, ballistic motion
MeSH terms
Interferon Regulatory Factor-8, Animals, Cell Movement, Humans, Leukocytes, Melanoma, Experimental, Spleen, Splenic Neoplasms, Mice, Knockout, Coculture Techniques, Interferon Regulatory Factors, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cancer-driven dynamics of immune cells in a microfluidic environment. https://app.cochat.ai/papers/10.1038/srep06639
The paper
Agliari, E., Biselli, E., De Ninno, A., Schiavoni, G., Gabriele, L., Gerardino, A., Mattei, F., Barra, A., & Businaro, L. (2014). Cancer-driven dynamics of immune cells in a microfluidic environment. Scientific Reports. https://doi.org/10.1038/srep06639

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.