Cancer-driven dynamics of immune cells in a microfluidic environment
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Scope of the present work is to infer the migratory ability of leukocytes by stochastic processes in order to distinguish the spontaneous organization of immune cells against an insult (namely cancer). For this purpose, spleen cells from immunodeficient mice, selectively lacking the transcription factor IRF-8 (IRF-8 knockout; IRF-8 KO), or from immunocompetent animals (wild-type; WT), were allowed to interact, alternatively, with murine B16.F10 melanoma cells in an ad hoc microfluidic environment developed on a LabOnChip technology. In this setting, only WT spleen cells were able to establish physical interactions with melanoma cells. Conversely, IRF-8 KO immune cells exhibited poor dynamical reactivity towards the neoplastic cells. In the present study, we collected data on the motility of these two types of spleen cells and built a complete set of observables that recapitulate the biological complexity of the system in these experiments. With remarkable accuracy, we concluded that the IRF-8 KO cells performed pure uncorrelated random walks, while WT splenocytes were able to make singular drifted random walks that collapsed on a straight ballistic motion for the system as a whole, hence giving rise to a highly coordinate response. These results may provide a useful system to quantitatively analyse the real time cell-cell interactions and to foresee the behavior of immune cells with tumor cells at the tissue level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



















Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Specifically, they showed that immune spleen cells lacking IRF-8 do not migrate towards cancer cells, nor interact with them as efficiently as wild type immune cells[48–50], suggesting a mechanism to explain why IRF-8 knock-out cells fail to exert proper immune-surveillance leading to a heavier metastatic burden.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [48]
The cited source says what the claim attributes to it.
In the citing paper
“To the best of our knowledge, only a limited number of recent studies have employed microfluidics to investigate immune-cancer cell interactions[18, 48–52], possibly because microfluidic models are not yet widely available to cancer researchers.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [48]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“They also showed that macrophages in co-culture expressed more Arginine-1, in an analogous manner to macrophage activation in the tumor microenvironment.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [48]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanahan, D., & Weinberg, R. A. (2000) · Cell · doi:10.1016/s0092-8674(00)81683-9 · Cited by 29,219
Scanning Electron Microscopy and X-Ray Microanalysis
Goldstein, J. I., Newbury, D. E., Michael, J. R., Ritchie, N. W. M., Scott, J. H. J., & Joy, D. C. (2018) · Springer eBooks · doi:10.1007/978-1-4939-6676-9 · Cited by 5,361
Circular Statistics in Biology
Watson, G. S., & Batschelet, E. (1982) · Technometrics · doi:10.2307/1267831 · Cited by 4,587
Scanning Electron Microscopy and X-ray Microanalysis: Third Edition
Goldstein, J. I., Newbury, D. E., Echlin, P., Joy, D. C., Lyman, C. E., Lifshin, E., Sawyer, L., & Michael, J. R. (2003) · Springer eBooks · doi:10.1007/978-1-4615-0215-9 · Cited by 1,797
Strange kinetics of single molecules in living cells
Barkai, E., Garini, Y., & Metzler, R. (2012) · Physics Today · doi:10.1063/pt.3.1677 · Cited by 683
First Steps in Random Walks: From Tools to Applications
Klafter, J., & Sokolov, I. M. (2011) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780199234868.001.0001 · Cited by 597
Perelson, A. S., & Weisbuch, G. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.1219 · Cited by 574
Schiavoni, G., Mattei, F., Sestili, P., Borghi, P., Venditti, M., Morse, H. C., Belardelli, F., & Gabriele, L. (2002) · The Journal of Experimental Medicine · doi:10.1084/jem.20021263 · Cited by 426
Self-citationThe Transmission Electron Microscope
Williams, D. B., & Carter, C. B. (1996) · Transmission Electron Microscopy · doi:10.1007/978-1-4757-2519-3_1 · Cited by 375
Cellular Constituents of Immune Escape within the Tumor Microenvironment
Kerkar, S. P., & Restifo, N. P. (2012) · Cancer Research · doi:10.1158/0008-5472.can-11-4094 · Cited by 370
Research works printed but not linked: 2
- Galper, T., Marre, O., Amodei, D., Schneidman, E., Bialek, W., Berry, I. I. & Michael, J. Searching for collective behavior in a network of real neurons. preprint arXiv 1306–3061 (2013).
- Weiss, G. H. Aspects and applications of random walks, (North-Holl. Press, Amsterdam, 1994).
Cited by
Corrò, C., Novellasdemunt, L., & Li, V. S. W. (2020) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00120.2020 · Cited by 561
Mouse models in oncoimmunology
Zitvogel, L., Pitt, J. M., Daillère, R., Smyth, M. J., & Kroemer, G. (2016) · Nature Reviews Cancer · doi:10.1038/nrc.2016.91 · Cited by 343
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Personalized Cancer Medicine: An Organoid Approach
Aboulkheyr Es, H., Montazeri, L., Aref, A. R., Vosough, M., & Baharvand, H. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.12.005 · Cited by 275
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
“They observed the migration of macrophages towards cancer cells [48] and tested different chemotherapy treatments in the microfluidic device.”
BackgroundOrgan-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Organoid models of gastrointestinal cancers in basic and translational research
Lau, H. C. H., Kranenburg, O., Xiao, H., & Yu, J. (2020) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-019-0255-2 · Cited by 194
Parlato, S., De Ninno, A., Molfetta, R., Toschi, E., Salerno, D., Mencattini, A., Romagnoli, G., Fragale, A., Roccazzello, L., Buoncervello, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01013-x · Cited by 181
Self-citation3D Tumor Models and Their Use for the Testing of Immunotherapies
Boucherit, N., Gorvel, L., & Olive, D. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.603640 · Cited by 171
Mimicking tumor microenvironment by 3D bioprinting: 3D cancer modeling
Shukla, P., Yeleswarapu, S., Heinrich, M. A., Prakash, J., & Pati, F. (2022) · Biofabrication · doi:10.1088/1758-5090/ac6d11 · Cited by 148
Cancer Modeling‐on‐a‐Chip with Future Artificial Intelligence Integration
Fetah, K., DiPardo, B. J., Kongadzem, E.-M. L., Tomlinson, J. S., Elzagheid, A. I., Elmusrati, M. S., Khademhosseini, A., & Ashammakhi, N. A. (2019) · Small · doi:10.1002/smll.201901985 · Cited by 121
Zhang, J., Tavakoli, H., Ma, L., Li, X., Han, L., & Li, X. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114365 · Cited by 114
Towards the development of human immune-system-on-a-chip platforms
Polini, A., del Mercato, L. L., Barra, A., Zhang, Y. S., Calabi, F., & Gigli, G. (2018) · Drug Discovery Today · doi:10.1016/j.drudis.2018.10.003 · Cited by 104
Engineering approaches for studying immune-tumor cell interactions and immunotherapy
Shelton, S. E., Nguyen, H. T., Barbie, D. A., & Kamm, R. D. (2021) · iScience · doi:10.1016/j.isci.2020.101985 · Cited by 93
“Others used the B16F10 melanoma model due to its well-established role in cancer immunotherapy research (Businaro et al., 2013; Agliari et al., 2014; Mattei et al., 2014).”
MethodOrgans on chip approach: a tool to evaluate cancer -immune cells interactions
Biselli, E., Agliari, E., Barra, A., Bertani, F. R., Gerardino, A., De Ninno, A., Mencattini, A., Di Giuseppe, D., Mattei, F., Schiavoni, G., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-13070-3 · Cited by 91
Self-citationRodenhizer, D., Dean, T., D'Arcangelo, E., & McGuigan, A. P. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701174 · Cited by 80
Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications
Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S. (2020) · Micromachines · doi:10.3390/mi11090849 · Cited by 73
How single-cell immunology is benefiting from microfluidic technologies
Jammes, F., & Maerkl, S. J. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0140-8 · Cited by 79
Cell and tissue engineering in lymph nodes for cancer immunotherapy
Najibi, A. J., & Mooney, D. J. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.023 · Cited by 80
Pozzi, S., Scomparin, A., Dangoor, S. I., Ajamil, D. R., Ofek, P., Neufeld, L., Krivitsky, A., Vaskovich‐Koubi, D., Kleiner, R., Dey, P., et al. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.04.001 · Cited by 79
Kumar, V., & Varghese, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201801198 · Cited by 76
Mencattini, A., Giuseppe, D. D., Comes, M. C., Casti, P., Corsi, F., Bertani, F. R., Ghibelli, L., Businaro, L., Natale, C. D., Parrini, M. C., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-64246-3 · Cited by 75
Self-citationSpatially resolved microfluidic stimulation of lymphoid tissue ex vivo
Ross, A. E., Belanger, M. C., Woodroof, J. F., & Pompano, R. R. (2016) · The Analyst · doi:10.1039/c6an02042a · Cited by 68
Bridging the gap between tumor-on-chip and clinics: a systematic review of 15 years of studies
Bouquerel, C., Dubrova, A., Hofer, I., Phan, D. T. T., Bernheim, M., Ladaigue, S., Cavaniol, C., Maddalo, D., Cabel, L., Mechta-Grigoriou, F., et al. (2023) · Lab on a Chip · doi:10.1039/d3lc00531c · Cited by 58
Chiarello, F., & Castellano, M. G. (2016) · International Journal of Game-Based Learning · doi:10.4018/ijgbl.2016040101 · Cited by 63
Investigations into the cancer stem cell niche using in-vitro 3-D tumor models and microfluidics
Sreepadmanabh, M., & Toley, B. J. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.03.009 · Cited by 60
Organoid of ovarian cancer: genomic analysis and drug screening
Liu, H., Xia, B., Jin, M., & Lou, G. (2020) · Clinical & Translational Oncology · doi:10.1007/s12094-019-02276-8 · Cited by 61
Microfluidic technologies for immunotherapy studies on solid tumours
Paterson, K., Zanivan, S. R., Glasspool, R. M., Coffelt, S. B., & Zagnoni, M. (2021) · Lab on a Chip · doi:10.1039/d0lc01305f · Cited by 54
Oncoimmunology Meets Organs-on-Chip
Mattei, F., Andreone, S., Mencattini, A., Ninno, A. D., Businaro, L., Martinelli, E., & Schiavoni, G. (2021) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2021.627454 · Cited by 51
Self-citationComes, M. C., Casti, P., Mencattini, A., Giuseppe, D. D., Mermet‐Meillon, F., Ninno, A. D., Parrini, M. C., Businaro, L., Natale, C. D., & Martinelli, E. (2019) · Scientific Reports · doi:10.1038/s41598-019-42475-5 · Cited by 45
Self-citationCascarano, P., Comes, M. C., Mencattini, A., Parrini, M. C., Piccolomini, E. L., & Martinelli, E. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102124 · Cited by 45
Rahmanian, M., Seyfoori, A., Ghasemi, M., Shamsi, M., Kolahchi, A. R., Modarres, H. P., Sanati‐Nezhad, A., & Majidzadeh‐A, K. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.04.024 · Cited by 42
Ringquist, R., Ghoshal, D., Jain, R., & Roy, K. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.114003 · Cited by 40
Microfluidics for cell-cell interactions: A review
Li, R., Lv, X., Zhang, X., Saeed, O., & Deng, Y. (2015) · Frontiers of Chemical Science and Engineering · doi:10.1007/s11705-015-1550-2 · Cited by 44
Engineered in vitro tumor models for cell-based immunotherapy
Ando, Y., Mariano, C. F., & Shen, K. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.03.076 · Cited by 39
Tissues and Tumor Microenvironment (TME) in 3D: Models to Shed Light on Immunosuppression in Cancer
Ho, T., & Msallam, R. (2021) · Cells · doi:10.3390/cells10040831 · Cited by 39
Dzobo, K., Rowe, A., Senthebane, D. A., AlMazyadi, M., Patten, V. A., & Parker, M. I. (2018) · OMICS A Journal of Integrative Biology · doi:10.1089/omi.2018.0172 · Cited by 38
Organoids Provide an Important Window on Inflammation in Cancer
Baker, K. (2018) · Cancers · doi:10.3390/cancers10050151 · Cited by 41
Chen, S.-C., Wu, P.-C., Wang, C.-Y., & Kuo, P.-L. (2020) · Scientific Reports · doi:10.1038/s41598-020-70694-8 · Cited by 33
The next level of 3D tumour models: immunocompetence
Nyga, A., Neves, J. B., Stamati, K., Loizidou, M., Emberton, M., & Cheema, U. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.04.010 · Cited by 37
Engineered fluidic systems to understand lymphatic cancer metastasis
Greenlee, J. D., & King, M. R. (2020) · Biomicrofluidics · doi:10.1063/1.5133970 · Cited by 31
Engineered models of tumor metastasis with immune cell contributions
Graney, P. L., Tavakol, D. N., Chramiec, A. G., Ronaldson-Bouchard, K., & Vunjak‐Novakovic, G. (2021) · iScience · doi:10.1016/j.isci.2021.102179 · Cited by 32
The Patient-Derived Cancer Organoids: Promises and Challenges as Platforms for Cancer Discovery
Bae, J., Choi, Y. S., Cho, G., & Jang, S. J. (2022) · Cancers · doi:10.3390/cancers14092144 · Cited by 27
Comes, M. C., Filippi, J., Mencattini, A., Casti, P., Cerrato, G., Sauvat, A., Vacchelli, E., Ninno, A. D., Giuseppe, D. D., D’Orazio, M., et al. (2020) · Neural Computing and Applications · doi:10.1007/s00521-020-05226-6 · Cited by 28
Self-citationThe Applications and Challenges of the Development of In Vitro Tumor Microenvironment Chips
Johnson, A., Reimer, S., Childres, R., Cupp, G., Kohs, T. C. L., McCarty, O. J. T., & Kang, Y. B. (2022) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-022-00755-7 · Cited by 26
Nuts and Bolts: Microfluidics for the Production of Biomaterials
Fontana, F., Martins, J. P., Torrieri, G., & Santos, H. A. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800611 · Cited by 27
Exact results for the first-passage properties in a class of fractal networks
Peng, J., & Agliari, E. (2019) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.5080481 · Cited by 24
Self-citationBretti, G., Ninno, A. D., Natalini, R., Peri, D., & Roselli, N. (2021) · Axioms · doi:10.3390/axioms10040243 · Cited by 24
Model-Based Tumor Growth Dynamics and Therapy Response in a Mouse Model of De Novo Carcinogenesis
Loizides, C., Iacovides, D. C., Hadjiandreou, M. M., Rizki, G., Achilleos, A., Strati, K., & Mitsis, G. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143840 · Cited by 26
Microfluidic Technologies in Advancing Cancer Research
Ajikumar, A., & Lei, K. F. (2024) · Micromachines · doi:10.3390/mi15121444 · Cited by 23
Advancements in melanoma cancer metastasis models
Melo, L. M. N., Kumar, S., Riess, V., Szylo, K. J., Eisenburger, R. T., Schadendorf, D., Ubellacker, J. M., & Tasdogan, A. (2022) · Pigment Cell & Melanoma Research · doi:10.1111/pcmr.13078 · Cited by 24
Preclinical tumor organoid models in personalized cancer therapy: Not everyone fits the mold
Hu, L., Yang, X. F., Lan, H., Fang, X., Chen, X., & Jin, K. (2021) · Experimental Cell Research · doi:10.1016/j.yexcr.2021.112858 · Cited by 22
Ninno, A. D., Bertani, F. R., Gerardino, A., Schiavoni, G., Musella, M., Galassi, C., Mattei, F., Sistigu, A., & Businaro, L. (2021) · Journal of Visualized Experiments · doi:10.3791/61895 · Cited by 19
Self-citationFrom simplicity to complexity in current melanoma models
Michielon, E., de Gruijl, T. D., & Gibbs, S. (2022) · Experimental Dermatology · doi:10.1111/exd.14675 · Cited by 19
A roadmap for translational cancer glycoimmunology at single cell resolution
Peixoto, A., Miranda, A., Santos, L. L., & Ferreira, J. A. (2022) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-022-02335-z · Cited by 16
Mass-Preserving Approximation of a Chemotaxis Multi-Domain Transmission Model for Microfluidic Chips
Braun, E. C., Bretti, G., & Natalini, R. (2021) · Mathematics · doi:10.3390/math9060688 · Cited by 18
Preclinical models for development of immune–oncology therapies
Wang, Y., Shelton, S. E., Kastrunes, G. M., Barbie, D. A., Freeman, G. J., & Marasco, W. A. (2022) · Immuno Oncology Insights · doi:10.18609/ioi.2022.41 · Cited by 18
Biochips—New Platforms for Cell‐Based Immunological Assays
Shao, N., & Qin, L. (2017) · Small Methods · doi:10.1002/smtd.201700254 · Cited by 12
Mencattini, A., Ninno, A. D., Mancini, J., Businaro, L., Martinelli, E., Schiavoni, G., & Mattei, F. (2019) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2019.06.012 · Cited by 13
Self-citationAgliari, E., Sáez, P. J., Barra, A., Piel, M., Vargas, P., & Castellana, M. (2020) · Science Advances · doi:10.1126/sciadv.aay2103 · Cited by 14
Self-citationParameter estimation techniques for a chemotaxis model inspired by Cancer-on-Chip (COC) experiments
Braun, E. C., Bretti, G., & Natalini, R. (2021) · International Journal of Non-Linear Mechanics · doi:10.1016/j.ijnonlinmec.2021.103895 · Cited by 18
Models for Monocytic Cells in the Tumor Microenvironment
Lee, S. W. L., Adriani, G., Kamm, R. D., & Gillrie, M. R. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-35723-8_7 · Cited by 12
Biomicrofluidic Systems for Hematologic Cancer Research and Clinical Applications
Chowdury, M. A., Heileman, K., Moore, T. A., & Young, E. W. K. (2019) · SLAS TECHNOLOGY · doi:10.1177/2472630319846878 · Cited by 13
Moresi, F., Noto, F., Vasudevan, J., Bisteau, X., Adriani, G., & Pavesi, A. (2025) · Advanced Therapeutics · doi:10.1002/adtp.202500098 · Cited by 13
Quantifying heterogeneity to drug response in cancer–stroma kinetics
Alemanno, F., Cavo, M., Cave, D. D., Fachechi, A., Rizzo, R., D’Amone, E., Gigli, G., Lonardo, E., Adriano Barra, A., & del Mercato, L. L. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2122352120 · Cited by 10
Application of microfluidic technology in cancer research and therapy
Azadi, S., Es, H. A., Kulasinghe, A., Bordhan, P., & Warkiani, M. E. (2020) · Advances in clinical chemistry · doi:10.1016/bs.acc.2020.02.012 · Cited by 12
Melanoma-on-a-chip model for anticancer drug injecting delivery method
Herreros, P., López-Hernández, A., Holgado, M., & Heras, M. F. L. (2024) · SLAS TECHNOLOGY · doi:10.1016/j.slast.2024.100219 · Cited by 9
Studying TCR T cell anti-tumor activity in a microfluidic intrahepatic tumor model
Adriani, G., Pavesi, A., & Kamm, R. D. (2018) · Methods in cell biology · doi:10.1016/bs.mcb.2018.05.009 · Cited by 10
An Agent-Based Interpretation of Leukocyte Chemotaxis in Cancer-on-Chip Experiments
Bretti, G., & Gaetano, A. D. (2022) · Mathematics · doi:10.3390/math10081338 · Cited by 8
Advances in microfluidic biofabrication technology for bone metastasis modeling
Khanmohammadi, M., Ahmadkhani, N., Volpi, M., Khederlou, K., Uppal, A., Hosseini, M., Zhang, Y. S., & Święszkowski, W. (2025) · Biofabrication · doi:10.1088/1758-5090/add95f · Cited by 8
A non local model for cell migration in response to mechanical stimuli
Marchello, R., Colombi, A., Preziosi, L., & Giverso, C. (2023) · Mathematical Biosciences · doi:10.1016/j.mbs.2023.109124 · Cited by 7
Tumor Immune Engineering: Developing In Vitro Assays to Understand the Tumor–Immune Crosstalk
Iyer, R. N., Vartak, M., & Dey, T. (2025) · Advanced Biology · doi:10.1002/adbi.202400735 · Cited by 4
Microfluidics for Immuno‐oncology
Ma, C., Harris, J., Morales, R. T., & Chen, W. (2019) · Wiley eBooks · doi:10.1002/9783527818341.ch5 · Cited by 5
Große, M., Burchardt, M., & Caetano-Pinto, P. (2025) · Future Pharmacology · doi:10.3390/futurepharmacol5030036 · Cited by 2
Using Integrated Cancer-on-Chip Platforms to Emulate and Probe Various Cancer Models
Tong, Z., Tong, W. Y., Peng, B., Wei, Y., Oddo, A., & Voelcker, N. H. (2019) · Springer eBooks · doi:10.1007/978-3-662-59596-1_4 · Cited by 3
Son, M., Lee, G., Son, J., Choi, S., Kim, Y., Lee, S., Yoon, Y.-R., Yoon, D. S., & Lee, S. W. (2015) · Biomicrofluidics · doi:10.1063/1.4905577 · Cited by 2
Inverse modeling of time-delayed interactions via the dynamic-entropy formalism
Agliari, E., Alemanno, F., Adriano Barra, A., Castellana, M., Lotito, D., & Piel, M. (2024) · Physical review. E · doi:10.1103/physreve.110.024301 · Cited by 2
Self-citationFilippova, S. Y., Тимофеева, С. В., Межевова, И. В., Shalashnaya, E. V., Rozenko, L. Y., Av, S., & Novikova, I. A. (2023) · Russian Journal of Oncology · doi:10.17816/onco516562 · Cited by 1
Engineering Organ-on-a-Chip Systems for Cancer Immunotherapy: Strategies and Assay Integration
Wang, J., & Wang, Z. (2026) · Bioengineering · doi:10.3390/bioengineering13050492 · Cited by 1
Campanile, E., Colombi, A., & Bretti, G. (2024) · Mathematical Biosciences · doi:10.1016/j.mbs.2024.109330 · Cited by 2
Validation of an agent-based model for cell interactions in a microfluidic chip
Panunzi, S., Pompa, M., D’Angelo, P. M., Bretti, G., & Gaetano, A. D. (2026) · PLoS ONE · doi:10.1371/journal.pone.0341962 · Cited by 1
Sadeghi, S. (2017) · Sabanci University
Advanced cell culture techniques for cancer research
Balik, K., Matulewicz, K., Modrakowska, P., Kozłowska, J., Montané, X., Tylkowski, B., & Bajek, A. (2020) · Physical Sciences Reviews · doi:10.1515/psr-2019-0059
D’Orazio, M., Pastore, D., Mencattini, A., Filippi, J., Antonelli, G., Corsi, F., Casti, P., Curci, G., Salmeri, M., Pacifici, F., et al. (2024) · Neural Computing and Applications · doi:10.1007/s00521-024-10767-1
3D bioprinting technology in cancer management: Applications, challenges, and future perspectives
Nandy, B. C., Dutta, S., Banerjee, B., & Mondal, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26518-1.00010-0
Inferring cell-cell interactions from quantitative analysis of microscopy images
Ronteix, G. (2021) · theses.fr (ABES) · doi:10.70675/d7d8111dz8487z47bbz890bzbfaa65fd24e1
Hypoxia-on-chip : from technological developments to biological applications
Bouquerel, C. (2023) · theses.fr (ABES) · doi:10.70675/d7d58b5dzd927z4235z8c54z8dbb6fd4757e · Cited by 1
Leveraging Microphysiological Systems to Facilitate Neutrophil‐Based Cancer Immunotherapy
Shao, S., Diehl, M. I., & Jones, C. N. (2026) · Advanced Science · doi:10.1002/advs.77572
Metadata
- Authors
- Agliari, E., Biselli, E., De Ninno, A., Schiavoni, G., Gabriele, L., Gerardino, A., Mattei, F., Barra, A., & Businaro, L.
- Affiliations
- Sapienza University of Rome (IT)
- Istituto Superiore di Sanità (IT)
- Istituto di Fotonica e Nanotecnologie (IT)
- Venue
- Scientific Reports
- Published
- 2014-10-16
- Volume
- 4
- Issue
- 1
- Pages
- 6639-6639
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5377582
- OpenAlex
- W2007723697
- Cited by
- 91
- References
- 42
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 16 · 2020: 17 · 2019: 8 · 2018: 8 · 2017: 6 · 2016: 6 · 2015: 3
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- creativecommons.org/licenses/by-nc-nd/4.0 (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- AIRUS (submittedVersion)
- arXiv (Cornell University)
- Funders
- Istituto Nazionale di Alta Matematica "Francesco Severi"
- Ministero della Salute (RF-2011-02347120)
- Associazione Italiana per la Ricerca sul Cancro (#11610)
- Gruppo Nazionale per la Fisica Matematica
- Topics
- Physical Sciences › Mathematics › Modeling and Simulation › Mathematical Biology Tumor Growth
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- leukocyte migration, splenocytes, B16F10 melanoma, antitumor immunity, cell-cell interactions, random walks, ballistic motion
- MeSH terms
- Interferon Regulatory Factor-8, Animals, Cell Movement, Humans, Leukocytes, Melanoma, Experimental, Spleen, Splenic Neoplasms, Mice, Knockout, Coculture Techniques, Interferon Regulatory Factors, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.